Validity and Reliability of Single Camera Markerless Motion Capture Systems with RGB-D Sensors for Measuring Shoulder Range-of-Motion: A Systematic Review
Provisionally accepted- Kyung Hee University, Seoul, Republic of Korea
Select one of your emails
You have multiple emails registered with Frontiers:
Notify me on publication
Please enter your email address:
If you already have an account, please login
You don't have a Frontiers account ? You can register here
Introduction: Assessing shoulder joint range-of-motion (ROM) is crucial for evaluating shoulder mobility but remains challenging due to its complexity. This review examined the potential of singlecamera markerless motion capture systems with an RGB-depth (RGB-D) sensor for shoulder ROM measurements, focusing on their reliability and validity. Methods: We systematically searched 9 databases through December 2022 for studies that evaluated the reliability and validity of single-camera markerless motion-capture systems in measuring simple (one-directional) and complex (multi-directional) shoulder movements. We extracted data on participant characteristics, device details, and measurement outcomes, and then assessed the methodological quality using the Consensus-Based Standards for the Selection of Health Results: Of the 2,976 articles identified, 14 were included in this review. The findings indicate that intra-rater reliability findings across 6 studies were inconsistent, with simple movements like abduction and flexion demonstrating better reliability and less heterogeneity compared to complex movements. Validity assessments across 12 studies also showed inconsistency, with abduction and flexion measurements exhibiting higher validity than rotational movements. Studies focusing on simple movements reported good to excellent validity, particularly for abduction and flexion. Quality assessments using the COSMIN checklist revealed that the methodological quality varied across studies, ranging from inadequate to very good.Discussion: This systematic review suggests that RGB-D sensors show promise for measuring shoulder joint ROM, especially in simple movements like flexion and abduction. However, complex movements and inconsistencies limit their immediate clinical applicability, necessitating further high-quality research with advanced devices to ensure accurate and reliable assessments.
Keywords: shoulder motion, range of motion, RGB-D sensor, single camera markerless motion capture, Systematic review
Received: 04 Feb 2025; Accepted: 09 May 2025.
Copyright: © 2025 Lee, Lee, Kim, Kim and Lee. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
* Correspondence: Seunghoon Lee, Kyung Hee University, Seoul, Republic of Korea
Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.