ORIGINAL RESEARCH article
Front. Bioeng. Biotechnol.
Sec. Nanobiotechnology
This article is part of the Research TopicOptical Imaging and Manipulation in the Biological WorldView all articles
Tapered fiber probe-based optical cardiac pacemaker
Provisionally accepted- 1Guangzhou University, Guangzhou, China
- 2Jiangsu Medical College, Yancheng, China
Select one of your emails
You have multiple emails registered with Frontiers:
Notify me on publication
Please enter your email address:
If you already have an account, please login
You don't have a Frontiers account ? You can register here
The disorders of cardiac rhythm usually induce severe cardiovascular pathologies which might pose significant threats to human health. Although multiple cardiac pacing modalities have been developed, most of them face potential limitations including structural complexity, spatiotemporal imprecision and invasive implantation requirements, thereby constraining their widespread biomedical applications. By leveraging the unique long-range focusing capability, we establish a tapered-fiber-probe (TFP) strategy enabling non-contact and high-precision near-infrared (NIR) optical pacing in zebrafish embryos, where sustained micron-scale spatial precision (3 m FWHM) was achieved at physiologically relevant working distances. Systematic characterizations revealed developmental-stage-dependent pacing sensitivity, with pacing efficacy progressively decreasing during early cardiogenesis (36 dpf) and stabilizing upon cardiac maturation (6 dpf). Meanwhile, anatomical mapping demonstrated 1.7-fold greater photosensitivity in sinoatrial regions compared to ventricular myocardium. Calcium imaging confirmed a photothermal mechanism wherein optical absorption of irradiated myocardial tissue activates thermosensitive protein channels, triggering calcium ion influx and subsequent depolarization. The proposed strategy enables spatiotemporally precise cardiac conduction and establishes a proof-of-concept platform for non-contact optical pacing in zebrafish embryos, which might provide potential bio-optical tool development for basic arrhythmia research in vivo.
Keywords: biophotonics, tapered fiber probe, Cardiac pacemaker, arrhythmia disease, opticalmanipulation
Received: 29 Jul 2025; Accepted: 30 Oct 2025.
Copyright: © 2025 Liu and Xie. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
* Correspondence: Xiaoshuai  Liu, lxshuai@gzhu.edu.cn
Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.
