STUDY PROTOCOL article
Front. Dent. Med.
Sec. Dental Materials
Volume 6 - 2025 | doi: 10.3389/fdmed.2025.1694614
This article is part of the Research TopicClinical Durability of Resin Composite RestorationsView all articles
Wear Resistance of Three Direct Resin Composites in Artificial Saliva at Varying pH Levels
Provisionally accepted- The Affiliated Changzhou Second People's Hospital of Nanjing Medical University. Changzhou Medical Center, Nanjing Medical University, 29 Xinglong Alley, Changzhou 213003, China., Changzhou, China
Select one of your emails
You have multiple emails registered with Frontiers:
Notify me on publication
Please enter your email address:
If you already have an account, please login
You don't have a Frontiers account ? You can register here
Objective To investigate the wear resistance of three resin composites in artificial saliva at varying pH levels. Methods Three resin materials—Coltene BRILLIANT™NG, 3M ESPE™Filtek™P60, and Kerr Sonicfill™2—were selected and subjected to reciprocating friction tests in artificial saliva with pH values of 2, 6.8, and 8. Wear volume was measured using a three-dimensional profilometer, and statistical analysis was performed using two-way ANOVA to compare differences in material loss among the resin groups and natural tooth enamel, considering both material type and pH as factors. Surface morphology of worn samples was analyzed via SEM. Results Wear scar analysis revealed no statistically significant differences in wear volume among groups under pH 6.8 artificial saliva. In pH 2 artificial saliva, Group A (P60 resin) exhibited the highest wear volume, while Group B (Kerr SonicFill resin) showed the lowest wear volume, closely resembling that of natural enamel. Under pH 8 conditions, Group A again demonstrated the highest wear volume, whereas Group C (Coltene resin) exhibited the lowest. Group B (Kerr SonicFill) displayed wear volumes comparable to natural enamel (Group D). P60 resin showed significantly greater wear volume in pH 2 and pH 8 compared to pH 6.8. Kerr SonicFill resin exhibited lower wear volume in pH 2 than in pH 6.8 and pH 8, with no significant difference between pH 6.8 and pH 8. Coltene resin displayed higher wear volume in pH 2 and pH 6.8 compared to pH 8, but no significant difference was observed between pH 2 and pH 6.8. Natural enamel showed significantly greater volume loss at pH 8 compared to pH 6.8. Conclusion Under the tested *in vitro* conditions, Kerr SonicFill resin demonstrated wear behavior most comparable to natural enamel across varying pH environments, showing stable performance. This suggests it could be a suitable choice for dental restorations requiring durability under varying pH conditions, though direct extrapolation to clinical performance requires caution. The increased wear of natural enamel at alkaline pH was an interesting finding warranting further study.
Keywords: composite resin, wear, pH, artificial saliva, SEM
Received: 28 Aug 2025; Accepted: 20 Oct 2025.
Copyright: © 2025 Yang, Xu, He and Tian. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
* Correspondence: Juzhong Tian, tjz1028@126.com
Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.