Your new experience awaits. Try the new design now and help us make it even better

CASE REPORT article

Front. Surg.

Sec. Vascular Surgery

Volume 12 - 2025 | doi: 10.3389/fsurg.2025.1598842

False Vertebral Artery Stenosis: An Rare Phenomenon

Provisionally accepted
  • 1Zhongnan Hospital, Wuhan University, Wuhan, China
  • 2Hanyang Hospital Affiliated to Wuhan University of Science and Technology, Wuhan, Hubei Province, China

The final, formatted version of the article will be published soon.

Trans-radial access (TRA) has gained widespread adoption in neurointerventional procedures, particularly for cerebral angiography. The success of trans-radial cerebral angiography crucially relies on the proper formation of the simmons-2 catheter loop to navigate the aortic arch and selectively catheterize the cerebral vessels. However, the potential of simmons-2 catheter loop configuration to induce angle change of the vasculature was not previously recognized in our institutional practice. We present a rare cerebrovascular imaging phenomenon identified during diagnostic and therapeutic neurointerventional procedures in a 60-year-old male patient. Selective cerebral angiography performed via right radial access demonstrated severe ostial stenosis of the right vertebral artery. Thus, endovascular stent placement was scheduled to address the right vertebral artery stenosis via trans-radial approach. Surprisingly, intraoperative vertebral artery angiography via 6F guiding catheter demonstrated complete resolution of the preoperative stenosis. We conducted a comparative analysis of subclavian artery and brachiocephalic trunk morphology using pre-and post-loop formation angiographic imaging. Angiographic analysis revealed that the simmons-2 catheter loop configuration resulted in a significant alteration of the angle between the horizontal subclavian artery and the descending brachiocephalic trunk, producing vertebral artery traction and apparent stenosis. The discrepancy arose from a previously unrecognized phenomenon: simmons-2 catheter loop configuration altered the angulation between the vessels, resulting in artefactual vertebral artery ostium stenosis during initial angiography. This case reveals previously unrecognized anatomic-vascular interactions influencing for trans-radial neurointerventional procedures. This report carries significant implications for procedural techniques and image interpretation in neurointerventional practice.

Keywords: Trans-radial cerebral angiography, Vertebral artery stenosis, Simmon-2, catheter, loop, case report

Received: 24 Mar 2025; Accepted: 22 Sep 2025.

Copyright: © 2025 Yan, Niao, Dong and Mei. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

* Correspondence:
Sun Dong, dongsun128@sina.com
Bin Mei, neuromei20@163.com

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.