Your new experience awaits. Try the new design now and help us make it even better

ORIGINAL RESEARCH article

Front. Surg.

Sec. Visceral Surgery

Volume 12 - 2025 | doi: 10.3389/fsurg.2025.1650828

Surgical outcomes of the closure of mesenteric defects in Side-to-side jejunoileal anastomosis plus proximal loop ligation (SSJIBL) using Absorbable and Nonabsorbable surgical sutures

Provisionally accepted
Yonglin  LiYonglin Li1Jing  WangJing Wang1Chengyu  WuChengyu Wu2Xiaojing  LuXiaojing Lu2Qi  ZhengQi Zheng1Rongwei  WeiRongwei Wei1Ziliang  ZongZiliang Zong1Yigang  ChenYigang Chen1*
  • 1Department of General Surgery, Wuxi No. 2 Hospital, Jiangnan University Medical Center, Wuxi, China
  • 2Department of General Surgery, The Affiliated Wuxi No. 2 Hospital of Nanjing Medical University, Wuxi, China

The final, formatted version of the article will be published soon.

Background: Mesenteric hiatal hernia represents a significant complication following gastrointestinal surgery, and the closure of mesenteric defects has been shown to mitigate the risk of such hernias. SSJIBL, a surgical technique that has gained prominence in recent years, is widely acknowledged for its efficacy in glucose reduction and its association with fewer complications. Nevertheless, there remains a gap in the literature regarding the optimal suture choice for closing mesenteric defects, as no definitive studies or reports have addressed this specific issue to date. So we wanted to know what sutures we could use to more safely close the mesenteric defect. Materials and Methods: 36 New Zealand rabbits were divided into three groups, NC, Absorbable suture and Non-absorbable suture. Group NC was not operated, group Absorbable suture close the mesenteric defect with absorbable suture, and group Non-absorbable suture close the mesenteric defect with non-absorbable suture; the rabbits were weighed and measured monthly, and after three months, the rabbits were observed to see if there was any internal hernia and to detect the tethered lacunae tension. Results: According to the results of the experiment, both absorbable suture and non-absorbable suture can induce infiltration of inflammatory cells and enhance adhesion strength relative to the NC group. Conclusion: Both absorbable and non-absorbable sutures are safe and reliable.

Keywords: SSJIBL, Mesenteric defect, Mesenteric hiatal hernia, Absorbable suture, Non-absorbable suture

Received: 20 Jun 2025; Accepted: 02 Sep 2025.

Copyright: © 2025 Li, Wang, Wu, Lu, Zheng, Wei, Zong and Chen. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

* Correspondence: Yigang Chen, Department of General Surgery, Wuxi No. 2 Hospital, Jiangnan University Medical Center, Wuxi, China

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.