REVIEW article

Front. Mar. Sci., 21 February 2019

Sec. Marine Biogeochemistry

Volume 6 - 2019 | https://doi.org/10.3389/fmars.2019.00035

Developing Autonomous Observing Systems for Micronutrient Trace Metals

  • 1. Moss Landing Marine Laboratories, Moss Landing, CA, United States

  • 2. Laboratoire Détection Capteurs et Mesures, Unité de Recherches et Développements Technologiques, Ifremer, France

  • 3. Department of Earth Sciences, Stellenbosch University, Stellenbosch, South Africa

  • 4. Joint Institute for the Study of the Atmosphere and Ocean, University of Washington and NOAA-Pacific Marine Environmental Laboratory, Seattle, WA, United States

  • 5. Atmosphere and Ocean Research Institute, The University of Tokyo, Chiba, Japan

  • 6. School of Marine Science and Policy, University of Delaware, Lewes, DE, United States

  • 7. School of Environmental Sciences, University of Liverpool, Liverpool, United Kingdom

  • 8. GEOMAR Helmholtz Centre for Ocean Research Kiel, Kiel, Germany

  • 9. Department of Ocean Systems (OCS), NIOZ Royal Netherlands Institute for Sea Research, and Utrecht University, Texel, Netherlands

  • 10. ICMAN – Institute of Marine Science of Andalusia (CSIC), Campus Universitario Río San Pedro, Cádiz, Spain

  • 11. Institute for Marine and Antarctic Studies and Antarctic Climate and Ecosystems Cooperative Research Centre, University of Tasmania, Hobart, TAS, Australia

Abstract

Trace metal micronutrients are integral to the functioning of marine ecosystems and the export of particulate carbon to the deep ocean. Although much progress has been made in mapping the distributions of metal micronutrients throughout the ocean over the last 30 years, there remain information gaps, most notable during seasonal transitions and in remote regions. The next challenge is to develop in situ sensing technologies necessary to capture the spatial and temporal variabilities of micronutrients characterized with short residence times, highly variable source terms, and sub-nanomolar concentrations in open ocean settings. Such an effort will allow investigation of the biogeochemical processes at the necessary resolution to constrain fluxes, residence times, and the biological and chemical responses to varying metal inputs in a changing ocean. Here, we discuss the current state of the art and analytical challenges associated with metal micronutrient determinations and highlight existing and emerging technologies, namely in situ chemical analyzers, electrochemical sensors, passive preconcentration samplers, and autonomous trace metal clean samplers, which could form the basis of autonomous observing systems for trace metals within the next decade. We suggest that several existing assets can already be deployed in regions of enhanced metal concentrations and argue that, upon further development, a combination of wet chemical analyzers with electrochemical sensors may provide the best compromise between analytical precision, detection limits, metal speciation, and longevity for autonomous open ocean determinations. To meet this goal, resources must be invested to: (1) improve the sensitivity of existing sensors including the development of novel chemical assays; (2) reduce sensor size and power requirements; (3) develop an open-source “Do-It-Yourself” infrastructure to facilitate sensor development, uptake by end-users and foster a mechanism by which scientists can rapidly adapt commercially available technologies to in situ applications; and (4) develop a community-led standardized protocol to demonstrate the endurance and comparability of in situ sensor data with established techniques. Such a vision will be best served through ongoing collaborations between trace metal geochemists, analytical chemists, the engineering community, and commercial partners, which will accelerate the delivery of new technologies for in situ metal sensing in the decade following OceanObs’19.

Introduction

Bioactive micronutrient metals are essential for cell functions and mediate vital biochemical reactions by acting as cofactors in many enzymes and as centers to stabilize enzymes and protein structures (Sunda, 2012). These micronutrients – cobalt (Co), copper (Cu), iron (Fe), manganese (Mn), nickel (Ni), zinc (Zn), and to a lesser extent cadmium (Cd) – are thus required for marine life, but can hinder cell growth at higher concentrations (e.g., through anthropogenic inputs in coastal regions). Since phytoplankton species have different cellular metal requirements (e.g., Ho et al., 2003; Twining and Baines, 2013), the supply and concentration of metal micronutrients in the ocean affects the growth and turnover rate of phytoplankton, and modulates phytoplankton species composition. The distribution of metal micronutrients ultimately influences the productivity of entire food webs and the rate of particulate carbon export to the deep ocean.

Over the past 30 years, from the pioneering work of John Martin on Fe limitation (Martin and Fitzwater, 1988; Martin and Gordon, 1988) to the ongoing GEOTRACES program that is mapping the distributions and investigating the biogeochemistry of trace elements and their isotopes throughout the ocean (Schlitzer et al., 2018), the database of discrete observations for Fe and other bioactive trace metals has grown by three orders of magnitude and encompasses observations in all ocean basins (Tagliabue et al., 2017 and references therein). These sampling efforts have greatly improved our understanding of micronutrient cycling, but are not sufficient to constrain the key processes underpinning metal micronutrient cycling and associated biological responses. For instance, Fe currently has the highest spatial and temporal observational coverage relative to all other metal micronutrients; however, Figure 1 illustrates that even for Fe there remains large spatial gaps along with poor temporal resolution. Ship-based sampling campaigns only provide a one-time snapshot of distributions in logistically accessible regions. However, micronutrients are generally characterized by short residence times and highly variable inputs in space and time (Tagliabue et al., 2017 and references therein). As a result, the external fluxes, removal rates, internal cycling, and residence times of bioactive trace metals remain poorly constrained and their spatial and temporal variability incompletely characterized, particularly in remote regions of the oceans. This lack of understanding cascades into an incomplete representation of ocean Fe cycling in the global models used to project the impacts of change in Fe-limited regions (Tagliabue et al., 2016).

FIGURE 1

Metal micronutrients enter the ocean through a variety of highly episodic sources, including atmospheric deposition, sediment–water exchange at the land–ocean interface and intermittent venting from hydrothermal vents, which supply both metals and metal-binding ligands to the deep ocean. Metal concentrations have been observed to vary from days to months as a result of the passage of mesoscale eddies (Fitzsimmons et al., 2015), changes in mixed-layer depth via wind-driven mixing (Nishioka et al., 2007, 2011), coastal upwelling (Elrod et al., 2008), and seasonal fluctuations in dust and associated wet deposition (Boyle et al., 2005; Sedwick et al., 2005). The biological response to changing metal micronutrient distributions is also highly dynamic, ranging from fast changes in cellular stoichiometry (Twining et al., 2010) to impacts on growth rates. Experimental evidence shows that enhanced inputs of metal micronutrients can either enhance (e.g., Fe, Coale et al., 1996) or inhibit (e.g., excessive Cu, Mann et al., 2002; Jordi et al., 2012) phytoplankton productivity on time scales of hours to weeks. In some coastal settings, metal availability and intracellular concentrations of domoic acid, a neurotoxin, appear to be tightly coupled (Maldonado et al., 2002), indicating an important role for metals in influencing the toxicity and occurrence of harmful algal blooms and the management response needed to mitigate impacts on local communities.

The short time-scale dynamics of micronutrient cycling are incompatible with discrete sampling approaches and require rapid and adaptive in situ observations to characterize episodic events and assess the biological implications of changing metal distributions. Developing the ability to obtain continuous, long-term in situ time-series for micronutrient metals is thus a pressing need in the field of trace metal biogeochemistry and such a development will improve model parameterizations of the key processes governing the distributions of micronutrients. Such work would better constrain metal fluxes and residence times, and improve our understanding of marine ecosystem dynamics following episodic events, as well as providing a baseline for detecting and predicting climate-driven changes. However, there are, at present, no micronutrient analyzers/sensors with analytical sensitivities suitable for open-ocean determinations of any of the micronutrient trace elements.

There are several regions in the ocean and specific episodic processes that would greatly benefit from high-resolution in situ metal measurements. Some of the areas that would provide the greatest benefit are either logistically difficult to reach during key seasonal transitions or need high-frequency observations to properly characterize sources and sinks of trace metals. The Southern Ocean, for example, where Fe plays a critical role in modulating productivity, lacks observations during key seasonal transitions (Tagliabue et al., 2012), which would provide important insights into the replenishment and depletion dynamics of Fe during the autumn–winter and winter–spring periods. Additionally, the Southern Ocean experiences variations in frontal positions and mixed-layer depths, affecting the recycling of micronutrients, leading to changes in plankton community structures (Deppeler and Davidson, 2017). An understanding of bioactive micronutrient dynamics would similarly be important in the subarctic North Pacific and Atlantic Oceans, which feature seasonal Fe limitation (Nishioka et al., 2007; Nielsdóttir et al., 2009; Ryan-Keogh et al., 2013; Westberry et al., 2016). Even the Arctic and Antarctic coasts represent important focus areas, where climate scenarios project enhanced continental runoff, and glacial and sea ice melting, which are expected to affect the distribution of metal micronutrients and ligands and thereby impact primary productivity (Deppeler and Davidson, 2017; Rijkenberg et al., 2018). In situ ocean metal micronutrient observations at high latitudes during seasonal transitions would greatly improve our ability to monitor and predict the biological responses (across phytoplankton, bacteria, and archaea) to changes in micronutrient concentrations under a changing climate.

The overarching goal of this paper is to make the case for the development and implementation of new in situ technologies for marine micronutrient analyses in the decade following OceanObs’19. In addition to core biogeochemical variables (e.g., T, S, O2, nitrate, Chl-a), we suggest that an ideal autonomous observing system for trace metal micronutrients would include the capability to measure total dissolved concentrations of Fe, Co, Cu, Mn, and Zn with detection limits suitable for open-ocean determinations and field endurance spanning from a month to 1 year depending on the deployment environment (Table 1). Following rigorous intercalibration and laboratory testing, we envisage that such a system could be deployed within the decade following OceanObs’19 at fixed observatories and aboard autonomous surface sampling vehicles with a high payload. In the following, we seek to (1) describe the current state of the art and analytical challenges associated with micronutrient analysis; (2) highlight technologies amenable to in situ deployment within the next decade, with a particular focus on techniques with potential for sub-nanomolar determinations of metals, including speciation; (3) identify key oceanic regions and processes where in situ monitoring would benefit pressing questions in trace metal biogeochemistry; and (4) develop a tangible roadmap for micronutrient metals sensing in the decade following OceanObs’19.

Table 1

ElementOpen-ocean concentration range1 (nmol kg-1)Desirable detection limit2 (nmol kg-1)Accuracy/precision (%)EnduranceFrequency
Fe0.03–30.1<10Month–yearHourly–biweekly
Cu0.4–50.5<10Month–yearHourly–biweekly
Co0.003–0.30.05<10Month–yearHourly–biweekly
Mn0.08–50.1<10Month–yearHourly–biweekly
Zn0.05–100.1<10Month–yearHourly–biweekly
Ni2–122<10Month–yearHourly–biweekly
Cd0.001–1.050.05<10Month–yearHourly–biweekly

Ideal specifications of an autonomous observing system for metal micronutrients in the decade following OceanObs’19.

The listed concentration and detection limits refer to total dissolved concentrations. 1From Bruland et al. (2014). 2Target detection limits refer to the minimum sensitivity that would be required to detect seasonal concentration changes in the euphotic zone.

Current Analytical State of the Art: Shipboard and In Situ

Metal micronutrient analysis on discrete seawater samples is typically carried out using inductively coupled mass spectrometry (ICP-MS), Flow Injection Analysis (FIA), and anodic or adsorptive cathodic stripping voltammetry (ASV and AdCSV, respectively). These techniques feature detection limits suitable for open-ocean determinations at sub-nanomolar levels, but are not amenable to in situ deployment in their current state (Table 2).

Table 2

MethodMetal micronutrientLOD (nM)SpeciesPros and cons
HR ICP-MS1Fe0.02Total dissolvedHigh precision, low detection limits, multi-elemental
Cu0.007Total dissolved (UV irradiation)determinations. Not deployable.
Co0.002Total dissolved (UV irradiation)
Mn0.007Total dissolved
Zn0.005Total dissolved
Ni0.026Total dissolved
Cd0.0006Total dissolved
Shipboard FIA2Fe0.03Total dissolved, Fe(II), Fe(III)Portable, low detection limits, easily assembled using
Cu0.03Total dissolved, labile Cu(II)commercially available components. High reagent
Co0.005Total dissolved (UV irradiation)consumption and maintenance requirements.
Mn0.03Total dissolved
Zn0.06Total dissolved
NiNo shipboard FIA method available
CdNo shipboard FIA method available
AdCSV/ASV (Mn and Cd)3Fe0.1Total dissolved (UV irradiation)Portable, low cost, low detection limits. Low reagent
Cu0.1Total dissolved (UV irradiation)consumption, power and maintenance requirements.
Co0.003Total dissolved (UV irradiation)
Mn0.2Total dissolved (UV irradiation)
Zn0.07Total dissolved (UV irradiation)
Ni0.1Total dissolved (UV irradiation)
Cd0.005Total dissolved (UV irradiation)

State of the art figures of merit for lab and shipboard measurements on discrete samples.

1From Milne et al. (2010). 2LODs refer to typical detection limits that can be achieved using FIA, not individual analyst reports for each element. 3From Achterberg and Braungardt (1999).

ICP-MS

Inductively coupled mass spectrometry is generally regarded as the gold standard for metal micronutrient analysis in shore-based laboratories by virtue of the high precision and low detection limits (picomolar range) afforded by the technique, as well as convenience, since multi-elemental determinations can be performed on a single sample following preconcentration and matrix elimination (Milne et al., 2010; Biller and Bruland, 2012; Lagerström et al., 2013; Minami et al., 2015; Rapp et al., 2017). However, current MS instrumentation requires complex sample pre-treatment, and is too resource demanding (gases, high-vacuum) or not sensitive enough (current miniature platforms) for in situ deployment in the foreseeable future.

FIA

Flow Injection Analysis manifolds couple preconcentration/ matrix elimination with absorbance, fluorescence, or chemiluminescence detection of individual elements (Fe, Cu, Co, Mn, and Zn, Table 2), and have been very popular methods for metal micronutrient analysis onboard ships since the early 1990s (Elrod et al., 1991; Resing and Mottl, 1992; Obata et al., 1993; Nowicki et al., 1994; Measures et al., 1995; Bowie et al., 1998; Laës et al., 2007; Shelley et al., 2010; Klunder et al., 2011; Nishioka et al., 2011; Grand et al., 2015b; Rijkenberg et al., 2018). FIA systems are compact, portable, assembled using commercially available low-cost components, offer low detection limits (<0.1 nM), a rapid analytical throughput and can be connected to continuous underway sampling systems for near-real time surface mapping applications (e.g., Vink et al., 2000; Bowie et al., 2002). However, shipboard FIA systems are prone to drift (Floor et al., 2015), are characterized with high maintenance requirements, and consume large amounts of reagents and power, making them unsuitable for long and/or autonomous deployments (e.g., Johnson et al., 1986). In situ chemical analyzers based on flow techniques have been developed for Fe and Mn (e.g., Massoth, 1991; Chin et al., 1992; Okamura et al., 2001; Sarradin et al., 2005; Vuillemin et al., 2009) and Cu (Holm et al., 2008), but the reported limits of detection of these submersible analyzers (Table 3), which were originally designed for monitoring metal dynamics in the vicinity of hydrothermal vent systems or in coastal regions, are inadequate for open-ocean determinations.

Table 3

SpeciesMethodLOD (nM)EnduranceMeasurement frequencyReference
Fe(II)LOC27CTD casts<1 hMilani et al., 2015
Fe(II) + Fe(III)LOC1.9At least 9 days45 minGeißler et al., 2017
Fe(II) + Fe(III)Miniaturized flow analyzer SCANNER25CTD castsNot listedChin et al., 1994
Fe(II) + Fe(III)Miniaturized flow analyzer ALCHIMIST70Not listed22 h-1Sarradin et al., 2005
Fe(II) + Fe(III)Miniaturized flow analyzer CHEMINI300Six monthsDailyVuillemin et al., 2009Laës-Huon et al., 2016
Total dissolved Cu(II)Miniaturized flow analyzer0.825 daysHourlyHolm et al., 2008
MnLOC28Not reported<1 hMilani et al., 2015
MnMiniaturized flow analyzer SCANNER22CTD castsNot listedChin et al., 1994
MnMiniaturized flow analyzer GAMOS0.23CTD castsNot listedOkamura et al., 2001
MnFiber optics spectrometer ZAPS0.1CTD castsNot listedKlinkhammer, 1994
Dynamic Cu, Cd, Pb, ZnASV15–30 pM for Pb, 30–50 pM for Cd, 0.5–1.4 nM for CuAt least 5 days3 h-1Braungardt et al., 2009
Fe(II), Mn(II)Voltammetry5000 nM Mn(II); 10,000 nM Fe(II)At least 3 weeksFour electrodes every 15 minLuther et al., 2008
Fe, Cu, Co, Mn, Ni, Cd1MITESS (automated trace metal sampler)HR-ICPMS26 monthsBell et al., 2002
Fe, Cu, Co, Mn, Ni, Cd1PRISM (automated trace metal sampler)HR-ICPMS26 monthsMueller et al., 2018

Figures of merit of currently available in situ sensors, analyzers, and autonomous samplers for dissolved metal micronutrients.

1Automated trace metal clean samplers collect samples that are analyzed upon retrieval of the sampler in shore-based laboratories. Hence, all bioactive elements can be analyzed back in the lab. 2LODs refer to the actual analytical method being used (here assumed to be HR-ICPMS).

Voltammetry

Among electrochemical methods, AdCSV with Hanging Mercury Drop Electrode has been widely applied for metal micronutrient analyses onboard ships (Fe, Cu, Zn, and Co, e.g., Achterberg and Braungardt, 1999). AdCSV systems are compact, portable, and commercially available, offering detection limits low enough to determine subnanomolar metal micronutrients (Table 2). Flow systems have also been combined to AdCSV for onboard trace metal analysis (Cu, Ni, Zn, Achterberg and van den Berg, 1994, 1996; Co, Daniel et al., 1997). Moreover, AdCSV systems are applicable for speciation measurements by using competitive ligand equilibrium method (Achterberg and Braungardt, 1999). However, AdCSV systems are less accurate than ICP-MS, less stable than FIA systems, need UV digestion for total metal measurements, consume Hg, and often require a stable mercury drop, all of which limit their application for autonomous deployments.

In situ trace level methods (Braungardt et al., 2009; Chapman et al., 2012) have used voltammetry systems that work in surface waters (∼upper 100 m) with anodic stripping voltammetry techniques, with and without gels, on the Hg film electrode surface (Table 3). New developments using gel integrated electrodes in in situ voltammetric sensors will allow discrimination between labile trace element concentrations from the total dissolved fraction, and thereby provide an indication of metal bioavailability. Initial work was conducted more than a decade ago (Tercier-Waeber et al., 2008), but further work is required. ASV can detect pM levels of trace metals (Zn2+, Cu2+, Cd2+, and Pb2+) by applying a deposition potential for up to 30 min, at a more negative than the reduction potential of the free metal (M) ion, [M(H2O)6]n+ to form M(Hg). To determine total metal concentrations, metal–ligand (M–L) complexes need to be dissociated so that the metal can be detected. There are two ways to do this and only the second has been used for in situ work: (1) acidification of the sample to pH ∼2 followed by UV oxidation prior to sample analysis and (2) application of a sufficiently negative potential to break down the complex at the electrode by reduction to M(Hg) plus L. Two reports (Braungardt et al., 2009; Chapman et al., 2012) have used an applied potential of -1.2 V vs. a Ag/AgCl reference electrode to determine the potentially bioavailable metal, which is operationally defined as the free ion plus labile M–L complexes. Conditioning or electrochemical cleaning of the electrode is accomplished between measurements to give excellent precision and an electrode lifetime of up to 2 weeks. Unfortunately, some unknown M–L complexes (e.g., Croot et al., 1999; Rozan et al., 2003) cannot be completely destroyed at -1.2 V, as the thermodynamic stability complexes are so strong that a more negative deposition potential (∼-1.6 V) must be applied to break up the M–L complex.

For Fe(III), competitive ligand exchange cathodic stripping voltammetry techniques (CLE-CSV) are required to detect pM levels of Fe. No in situ method has been developed and tested (Lin et al., 2018), and unknown Fe–L complexes will need to be broken up by acidification and UV oxidation, then buffered to circumneutral pH, so the competitive ligand can complex the Fe(III) for analysis.

In Situ Micronutrient Observations: Challenges

Choice of Infrastructure

Independent of the target parameters, in situ monitoring in remote oceanic settings typically requires instrumentation that is robust, compact, fully automated, and capable of operating without servicing for extended periods of time with minimal reagent needs, low power consumption, and high data storage capacity (Delory and Pearlman, 2018). In several areas and seasons, such as the wintertime Southern Ocean, infrastructure and attached devices must be able to withstand extreme weather conditions. The power requirements of prototype sensor systems, which will depend on the analytical measurement frequency and environmental conditions (temperature, pressure), will need to be carefully evaluated in order to determine on which platform or vehicle the sensor package can be deployed. Platform-based observatories can support large and power-hungry instruments, while mobile gliders and profilers will require miniaturized, light-weight sensors with low power consumption and high measurement frequencies. The following sections provide more details on some of the challenges that in situ sampling and observation methods for trace micronutrients will face.

Analytical Sensitivity and Field Endurance

In the open ocean, most micronutrient metals are present at sub-nanomolar concentrations in surface waters that increase to a few nanomolar in deeper waters (Bruland et al., 2014). Monitoring subtle variations in bioactive micronutrients in the open ocean thus requires the development of highly sensitive analyzers characterized with detection limits <0.1 nM and a precision on the order of ±0.05 nM (Table 1). In addition, micronutrient analyzer prototypes should have an endurance of at least 1 month, irrespective of the measurement frequency, to enable preliminary deployments at ocean observatories serviced at monthly intervals. However, in remote settings such as in the Southern Ocean where servicing can only be performed once yearly, a 12-month endurance would be necessary with a measurement frequency suitable to constrain seasonal changes (i.e., twice daily). While some automated in situ chemical analyzers provided month-long records of Fe (Chapin et al., 2002; Laës-Huon et al., 2016), Mn (Klinkhammer, 1994; Okamura et al., 2001), and Cu (Holm et al., 2008) in coastal settings and in the vicinity of hydrothermal vents (Figure 2), there are currently no autonomous analytical techniques that can measure micronutrient metal species at the necessary detection limits for open ocean work.

FIGURE 2

Among the various analytical techniques for metal micronutrients amenable to in situ deployment (electrochemistry, wet chemistry), miniaturized flow-based techniques coupling analyte preconcentration with optical detection (spectrophotometric, fluorometric, or chemiluminescent) have the greatest potential to achieve the analytical sensitivity and accuracy necessary for autonomous open-ocean micronutrient determinations within the next decade. However, the use of reagents may ultimately limit the endurance of wet chemical analyzers for long-term monitoring applications (>1 month) owing to reagent storage and shelf life. In addition, sub-nanomolar detection of micronutrients using wet chemical analysis is often based on spectrophotometric catalytic reaction methods, which require precise thermoregulation of the instrument (reaction chamber, reagents, and in situ standards) (Laës et al., 2005). Temperature regulation is a technical challenge (mechanical composition of the housing, power consumption, electronic enslavement, temperature inertia, and the use of multivariate standard curves) that depends on the range of temperature variation encountered in the environmental setting: surface buoys, profilers, or deep seabed observatories. These limitations suggest that the development of novel analytical chemistries that are not responsive to temperature variations would be highly desirable.

Avoiding Contamination

Contamination is one of the major hurdles associated with trace metal analysis, and will require careful consideration in the design of autonomous analyzers housings (e.g., using metal free components such as Teflon or LDPE that are in contact with the sample), as well as the selection of non-contaminating platforms from which to deploy them. The extremely low natural concentrations of metals and their ubiquity in traditional sampling equipment (ships, frames, bottles) have led trace metal geochemists to develop extreme methodologies to avoid contamination during all phases of sampling and analysis. Specialized sampling systems for vertical profiling have been developed using polymer-based hydrowires and plastic-coated or titanium rosette frames fitted with sampling bottles that are lined with Teflon or constructed using high-purity plastics (de Baar et al., 2007; Measures et al., 2008; Cutter and Bruland, 2012). To avoid introduction of contaminants following recovery of the sampling package, subsampling is carried out in class 100 filtered air spaces and rigorously cleaned plastic containers are used for sample storage. In situ monitoring will obviously eliminate some of these issues, most notably during sample acquisition and processing (filtration, acidification) and by removing the need to transfer and store the sample into a clean container prior to analysis. However, not all available deployment platforms will be suitable for in situ metal sensors. For example, deploying a sensor on a moored profiler will require the use of non-metallic components or the addition of vanes to orient the sensor intake upstream of the mooring line. Therefore, some existing ocean observing infrastructure (OOI) will need to be customized in order to accommodate new micronutrient sensors while other ocean observing assets may not be suitable at all.

Biofouling in oceanic environments can take place very quickly, particularly in surface waters during periods of high biological productivity, and can lead to data quality deterioration in less than a few weeks’ time (Delory and Pearlman, 2018). Processes to minimize biofouling effects are therefore necessary to ensure the long-term reliability of in situ monitoring devices. Considering that the most effective biofouling prevention relies on the use of metals (e.g., Cu coatings), the development of metal-free biofouling coatings may be necessary to prevent contamination of metal sensors/analyzers, particularly in regions where sub-nanomolar metal concentrations are prevalent. The intricacies of trace metal analysis will thus potentially restrict the integration of newly developed metal sensors into existing ocean observing assets.

Metal Speciation

Metal micronutrients can exist in a variety of redox states, chemical species, and in a range of operationally defined physical forms. The majority of historical metal micronutrient observations consists of total dissolved concentrations, which are obtained following separation from the particulate phase using 0.2–0.45 μm pore size filters and acidification to pH < 2 using a strong acid. The total dissolved metal fraction includes colloids, organic and inorganic complexes, as well as free hydrated ions (<0.02 μm), which may be the most bioavailable species to biota. The operationally defined total dissolved metal fraction has been adopted based on historic sample filter sizes. Acidification allows sample integrity to be preserved prior to analysis and for the comparison of data from one location to the other and among various analytical labs. It also allows organically complexed metals to be dissociated and thus make them accessible to the analytical methodology.

To provide continuity with historical data, it is desirable to develop in situ metal micronutrient sensors with the capacity to measure total dissolved metal concentrations. However, this will also pose a technical challenge for long-term unattended observations, as it implies samples which need to be filtered and acidified for longer than a few minutes prior to analysis. The filters would need to be either automatically changed or cleaned at regular intervals to provide a representative sample of the total dissolved metal concentrations and to avoid clogging of the overall system. Additionally, while obtaining bulk total dissolved concentrations is geochemically meaningful in order to quantify external fluxes and budgets of micronutrient metals (e.g., for Al and Fe for dust deposition), its interpretation is challenging when attempting to determine which metal species are most available to resident biota. In this regard, the development of in situ metal analyzers that do not require pre-treatment (filtration and acidification) may provide additional insights into the reactivity of metal micronutrients in their natural state, thereby providing measurements that are more representative of bioavailability than total dissolved concentrations. It would also simplify in situ chemical analyzer manifolds and increase their measurement frequency, by removing one analytical step characterized with slow kinetics (i.e., the liberation of metals from ligand complexes). However, if filtration is avoided, particulates and biofouling could limit long-term deployment by blocking channels of microfluidics systems. Further assessment is required to fully resolve this issue.

Long-Term Accuracy: In Situ Calibration

To maintain analytical accuracy over long (months) periods, micronutrient metal sensors will need to be calibrated autonomously and accuracy assessed through the use of external standards. In the case of sensors measuring total dissolved metal concentrations (i.e., filtered and acidified), in situ calibration can be performed using acidified onboard standard(s) run at regular intervals throughout the deployment period. The shelf life of acidified onboard standards for total metal determinations is not expected to be an issue, as illustrated by the long-term stability of the SAFe and GEOTRACES community standards, which have exhibited stable concentrations for a variety of metals over several years. Quality control will prove more challenging for in situ speciation determinations, since it will be more difficult to preserve the standard solution (e.g., Fe (II)) over extended deployment times.

Measurement Frequency, Data Acquisition

End-users desire sensors that can be deployed for a minimum of 1 month and up to 12 months with confidence, have high measurement frequencies (hours to days; Table 1) and minimal servicing requirements. Ideally, these sensors would employ real-time satellite reporting of the metal micronutrient concentrations along with other ancillary biogeochemical parameters (e.g., T, S, Chl-a) to enable adaptive sampling. Increasing the measurement frequency, which depends on the environment, sampling mode and research questions, implies an increase in data storage capacities. For current metal micronutrient analysis onboard ships, post-cruise data processing (reagent blank, optical blank, electrochemical background subtraction) is carefully employed. Such high-quality corrections will need to be implemented for the next generation of in situ sensors and one of the next challenges would be to consider when and how to apply corrections from in situ calibration or from in situ quality control. Globally accepted definitions of the speciation (physical, redox, chemical speciation) for metal micronutrients concentrations produced by sensors will also need to be considered before integrating them into databases and global models.

Fostering Widespread Use

The commercialization of plug-and-play micronutrient metal sensors with sub-nanomolar sensitivity is unlikely within the next decade due to the relatively small market for such devices and the high costs associated with prototype development, validation, and manufacturing of the final product. For this reason, most micronutrient metal sensor development work will continue to be carried out at research institutions, where prototypes are engineered in house using specialized instrumentation with a high level of expertise for fabrication, operation, deployment, and data processing (e.g., Klinkhammer, 1994; Okamura et al., 2001; Holm et al., 2008; Laës-Huon et al., 2016). In addition, the development work required to convert early prototypes into robust, reliable, and validated instruments for month-long deployments in the open ocean spans across more than one typical 3–5 year funding cycle. It is also difficult to sustain using research funding schemes that often prioritize innovation over continued development and validation. Thus, emerging sensors rarely go beyond the prototype stage, which hinders extensive use by the wider community.

To foster widespread deployments, one possibility would be to promote the development of autonomous micronutrient analyzers assembled using commercially available or 3D printed components and operated using open-source electronics, microcontrollers, software, and instrument housings. This strategy, which proved popular with the Do It Yourself (DIY) environmental-sensor makers community, may facilitate the fabrication and operation of low cost wet-chemical micronutrient metal sensors and maximize replication and operation by a greater number of end users worldwide. Indeed, the current popularity of custom-made FIA manifolds for the analysis of trace micronutrients onboard ships may be attributed to the fact that these manifolds can be built using commercially available components that do not require a high degree of expertise for assembly and software control. Applying a DIY open-source strategy and readily available technology would greatly simplify the developmental pathway from laboratory to the ocean and would lower the overall costs of the development and production of wet chemical analyzers. This approach will likely attract more analytically inclined trace metal geochemists to participate in the development. Consequently, the community would greatly increase the number and capability of prototype analyzers for bioactive micronutrient metals that could be readily deployed and tested on short-term missions aboard autonomous surface vehicles or at coastal monitoring nodes. Such an increase in the number of sensors will ultimately lead to robust concentration reports of defined sets of intercalibrated metal species, determined with well-accepted sampling and analytical protocols.

Technologies with Potential Within a Decade

Several analytical technologies have the potential to be deployed in situ for micronutrient metal analysis in the decade following OceanObs’19 (Table 4). These include (1) miniaturized wet chemical analyzers, which will likely achieve the analytical sensitivity required for open-ocean determinations but will have a limited endurance due to power requirements, as well as reagent stability and consumption, and (2) voltammetric sensors which are proven in high metal concentration environments (e.g., coastal systems, continental margins, and hydrothermal vent fields), and (3) passive preconcentration samplers, which have the potential to be mass deployed at low cost but will need to be recovered periodically for analysis, and thus will be most amenable to deployment in easily accessible coastal regions, where they could be incorporated in citizen monitoring programs.

Table 4

TechniqueAdvantagesDisadvantages
Wet Chemical
Analyzers
High resolution, accuracy, and precision
Relatively fast response time
Can be calibrated in situ
Expensive
Many analyzers have high power requirements
Relatively bulky
Biofouling
High maintenance costs
Longevity limited by reagent use and stability
Waste generation
Electrochemical
methods
Inexpensive
Easy to use
Large measurement range
Speciation measurements
Not influenced by turbidity
Lower resolution, accuracy, precision
Subject to ionic interferences, organic matter
High instrument drift
Biofouling
Difficult to calibrate in situ
Autonomous trace
metal clean samplers
Good starting point for remote locations with challenging environmental conditions (i.e., high latitudes)
Multi-elemental determinations
Limited measurement frequency More prone to storage and contamination artifacts
Require expert shore-based analysis Biofouling
Passive
preconcentration
samplers
Inexpensive
Easy to use
No power source
Preconcentration included
Multi-elemental determinations
Lower resolution, accuracy, precision
Require lab testing and intercalibration
Integrative concentration measurement which is hard to calibrate
Require expert shore-based analysis

Summary of attributes of potential techniques for in situ metal micronutrient determinations within the next decade.

Miniaturized Wet Chemical Analyzers

Lab-on-Chip

The miniaturization of existing reagent-based assays holds great promise for micronutrient sensing on moorings, cabled-arrays, and autonomous underwater vehicles (Statham et al., 2003, 2005; Gamo et al., 2007; Doi et al., 2008). Recent advances in microfabrication have led to the development of automated Lab-on-Chip microfluidic analyzers, which are compact, self-calibrating, fully automated, low cost, and operate standard absorbance methods with low power and reagent consumption (Figure 3). These instruments have been deployed for up to 2 months in estuarine and coastal settings, providing hourly macronutrient data (N, P) with an accuracy comparable to that of laboratory-based auto-analyzers (Beaton et al., 2012; Clinton-Bailey et al., 2017; Grand et al., 2017; Vincent et al., 2018). While fully automated Lab-on-Chip analyzers were recently developed for Fe (II) and Mn, their detection limits [2 nM, Fe(II), Geißler et al., 2017; 28 nM Mn, Milani et al., 2015] restrict their use to areas characterized by high concentrations, such as estuarine and coastal settings, oxygen minimum zones, and hydrothermal plumes. To achieve the sensitivity (∼0.1 nM) necessary for metal micronutrient determinations in open ocean settings (Table 1), analyte preconcentration protocols compatible with the Lab-on-Chip technology will need to be developed and on-chip detection capabilities extended to fluorescence, chemiluminescence, and/or Cavity Ringdown Spectroscopy. These ongoing developments will enable Lab-on-Chip sensors to operate existing wet chemical assays for Mn, Fe, Zn, Cu, and Co within the next decade.

FIGURE 3

Micro-Sequential Injection Lab-on-Valve

Micro-Sequential Injection analyzers are another class of automated, miniaturized wet chemical analyzers with potential for in situ deployment (Figure 4). Presently best suited to laboratory and shipboard determinations (Oliveira et al., 2015; Grand et al., 2016), these compact instruments share many of the features that have made FIA systems popular for shipboard metal micronutrient determinations. Indeed, Micro-Sequential Injection analyzers are made using commercially available components, are easily customizable, fully automated, and can operate absorbance, fluorescence, and chemiluminescence determinations coupled with analyte preconcentration to reach detection limits in the sub-nanomolar range. However, unlike FIA systems, they are characterized with low reagent consumption (100s of microliters per sample), are less prone to drift, and do not require much maintenance, which make micro-Sequential Injection analyzers better suited to long-term unattended operation relative to their FIA counterparts.

FIGURE 4

At present, the application of micro-Sequential Injection to micronutrient metal determinations at open ocean levels is limited to the shipboard analysis of total dissolved Zn and Fe, with reported detection limits of 50 pM for Zn (Grand et al., 2016) and 1 nM for Fe (II) (Oliveira et al., 2015). Micro-Sequential Injection is thus a proven analytical technology for sub-nanomolar metal micronutrient detection, but unlike Lab-on-Chip platforms, micro-Sequential analyzers have not yet been engineered for in situ deployment. Further work is required to integrate all micro-Sequential Injection components (Lab-on-Valve, pump, detectors, electronics, and microcontroller) into compact, submersible housings, which will enable the deployment of micro-Sequential Injection analyzers at fixed locations (cabled observatories) and possibly for surface mapping applications onboard unmanned surface vehicles (e.g., wave gliders, Sail Drones, Autonomous Underwater Vehicles) in the decade following OceanObs’19.

Electrochemical Methods

One possibility for in situ applications of ASV is to use a solid working electrode instead of a mercury drop (Sundby et al., 2005; Luther et al., 2008). A new in situ copper microsensor using a vibrating gold microwire working electrode (Gibbon-Walsh et al., 2012), an iridium wire counter electrode, and a solid state reference electrode made of AgCl coated with an immobilized electrolyte and protected with Nafion has recently been developed. This sensor is able to detect Cu at nanomolar concentrations in coastal waters (2.0 ± 0.5 nM) and performs speciation measurements. The current version of the system has been deployed in situ for hydraulic, electronic, and pressure tests (2750 m) aboard the Nautile submarine (Cathalot et al., 2017). Although the detection limit is currently too high for open-ocean applications, it may be lowered by increasing the deposition step time, thereby offering another prospect for in situ ASV determination of Cu at sub-nanomolar levels. Conditioning and electrochemical cleaning of the electrode remains, however, as for the classical in situ voltammetric systems, a considerable challenge.

For environmental systems such as hydrothermal vents, diffuse flow ridge flanks, seeps, and sediments that are metal sources with higher concentrations (micromolar) of Fe and Mn, in situ solid Au/Hg working electrodes, have been tested and calibrated to 5000 m and from 2 to 60°C (Luther et al., 2008; Cowen et al., 2012). These voltammetry systems have been operated using the Alvin submersible and the Jason II ROV in dynamic flowing vent and diffuse flow waters. In such environments, autonomous systems have been deployed for up to 3 weeks. These systems are amenable to integration into Ocean Observing Initiative assets where power is not limited. Fast scan voltammetry techniques (∼2 s for complete data acquisition) were used without a stripping or preconcentration step due to the elevated metal concentrations in these environments. The method uses a 5 s conditioning or cleaning step so that multiple analytes can be detected simultaneously every 7–10 s to study the dynamics of the source waters in these environmental systems.

In Situ Collection, Preservation, and Preconcentration

Serial Automated Trace Metal Clean Samplers

During the development and testing phase of the chemical analyzers and sensors described above, it would be desirable to foster the development and use of trace metal clean devices that can collect and preserve samples for later laboratory analysis. The benefits of this approach are twofold. First, developing the capability to collect and preserve trace metal clean seawater samples in situ would allow obtaining time-series in environments that are only accessible once a year and are characterized with challenging conditions for any newly developed sensor, such as in the Southern Ocean. Second, the application of proven, autonomous trace metal clean samplers would be extremely valuable for testing and intercalibration of future in situ analyzers and sensors. The technology for autonomous trace metal samplers is already available and mature enough to be deployed within the next decade. Examples include the MITESS sampler (Bell et al., 2002), the newly developed PRISM sampler (Mueller et al., 2018), ANEMONE-11 (Okamura et al., 2013), the commercially available McLane Labs Remote Access Sampler (RAS), and the Biogeochemical AUV sampler CLIO, which is currently under development at WHOI. Each of these different autonomous sampler types has different advantages and disadvantages for remote sampling of low level, trace metal clean open ocean seawater, and the type of application will determine which one(s) are suitable. Some further refinements may be necessary to optimize the sampler type for the project needs (e.g., endurance, type of deployment, ocean conditions).

Passive Preconcentration Samplers

A complementary approach to automated samplers and in situ analysis of micronutrient metals is the development of passive sampling techniques. Passive sampling is based on the diffusion of the analyte across a porous membrane (hydrophobic or hydrophilic) into a receiver phase (solid or liquid), where the analyte is accumulated at a rate that is proportional to the external concentration. After a set deployment period (days, weeks, months), the sampler is retrieved, and back in the laboratory the analyte is extracted from the receiver phase and analyzed. Passive samplers thus provide a time-averaged weighted concentration of the species of interest, which, in contrast to discrete sampling, increases the likelihood of capturing intermittent sources and sinks. In addition, passive samplers have no moving parts, do not require a power source, are inexpensive, and could thus be mass deployed, particularly in coastal regions where they can be easily retrieved. Another notable feature of passive samplers is that they collect and pre-concentrate the analyte in one step, which is particularly beneficial for metal species present at sub-nanomolar levels in seawater.

There are several types of passive sampling devices that have been developed over the past 30 years. Among these, Diffusive Gradient Thin (DGT) Gels and, more recently, Polymeric Inclusion Membranes (PIMs) have been deployed in coastal and inland waters (Twiss and Moffett, 2002; Shiva et al., 2016; Almeida et al., 2017), and appear to have the most potential for micronutrient metal determinations. DGTs were also used successfully (analyzing a suite of trace metals at sub-nanomolar level) on discrete samples from the Southern Ocean (Baeyens et al., 2011) and more recently aboard a SeaExplorer glider in the Mediterranean Sea (Baeyens et al., 2018). It should be noted that passive samplers collect samples over the time interval of the deployment. Thus, while they are more likely to collect transient signals over the time interval of the deployment, they will also average all transient signals over the time interval of the deployment. Prior to widespread use, these techniques will require further laboratory testing and validation to determine which metals species are being measured (free ions and small and possibly weaker metal–ligand complexes), and to quantify metal concentrations, given poorly constrained diffusion rates.

A Roadmap Toward Autonomous Micronutrient Observing Systems

There are several regions (e.g., high latitudes) and specific episodic processes (e.g., seasonal transitions) that would greatly benefit from high-resolution in situ metal measurements in order to characterize and quantify sources and sinks of trace metals in the global ocean. Sensor development would also address an urgent need to improve predictions, in a rapidly changing ocean, of the plankton response (phytoplankton, bacteria, and archaea) to variations in micronutrient concentrations, following episodic events and/or at seasonal transitions.

Of the bioactive metal micronutrients (Fe, Zn, Co, Mn, Co, Ni, and Cd), Fe has received the most attention considering that it limits primary productivity in large parts of the world’s ocean, and imparts a significant influence on phytoplankton species composition. As such, Fe should probably be the prime target for sensor development and field implementation in the next decade, not only to improve the quantification of fluxes but also to better constrain the parameterizations of regional and global numerical models (Tagliabue et al., 2016). In addition, the technology and lessons learned from the development of an open ocean Fe sensor could facilitate the development of sensors for other important metal micronutrients, particularly for reagent-based analyzers which will operate using similar fluidic architectures and detection schemes. However, subsequently, high-frequency observations would be desirable for the full suite of essential trace elements, such as zinc (Southern Ocean: Vance et al., 2017; subarctic North Pacific: Kim et al., 2017).

Some of the areas that would provide the greatest benefit (e.g., high latitudes) are logistically difficult to reach. The ability to meet the challenge of producing metal sensors capable of operating in these remote open ocean regions is unlikely in the decade following OceanObs’19 due to the immaturity of metal-sensor development at this time. However, within this timeframe, it is reasonable to expect the development of sensors for less extreme environments at sites that currently host time series activities (HOT, BATS, CALCoffi, etc.), at cabled ocean observatories, which are regularly serviced, or in areas where metal concentrations are above open ocean levels. At remote high latitudes, the development and implementation of autonomous trace metal clean sample collectors and/or passive samplers retrieved at yearly intervals with ensuing shore-based analysis is an achievable outcome within the next decade. In the following, we describe a series of tangible outcomes, that should be the focus of research and development efforts in the decade following OceanObs’19.

Testing and Intercalibration

Development of metal sensors for remote deployment requires analyzers/sensors that are well tested in terms of electronic performance, endurance, and analytical performance under all operating conditions (i.e., freezing conditions and remoteness). Thus, before implementing in situ chemical analyzers, electrochemical sensors, and passive samplers on various types of platforms, the systems must be rigorously tested and validated under controlled laboratory conditions. Such long-term unattended laboratory tests should be standardized and include (1) temperature and pressure effects on analytical sensitivity, drift, and reagent shelf life (for methods sensitive to such changes, e.g., Okamura et al., 2001; Weeks and Bruland, 2002); (2) aging of the sensor (sunlight, seawater spray, vibrations); (3) the potential for biofouling and ways to mitigate it without metal-based biocides; and (4) a thorough intercalibration of the analyzer/sensor data quality (including speciation) with that of established techniques with input and guidance from the GEOTRACES community of analysts. These tests, which should at least be performed over a month-long period, will provide a first estimate of required operational settings in terms of robustness, reliability over time (figure of merits, drift), and lifetime without maintenance and power consumption, each of which will depend on the environmental conditions of the deployment and the analytical measurement frequency required for a given application. Such tests are theoretically feasible using existing monitoring platforms, pressure chambers, and test pools. However, as mentioned above, these tests are difficult to sustain beyond the typical 3–5 year time scale of a typical method development research grant and require resources that are not available to all developers (i.e., pressure chambers and test pools). Yet, they are critical to ensure end-users’ acceptance and foster widespread usage by the community.

Surface Mapping Along Dry and Wet Atmospheric Deposition Gradients

Areas where dust deposition is important would be well served by the addition of high-frequency measurements. Dust deposition is an important source of trace metals to the open ocean, especially for Fe, whose availability influences productivity at high latitudes and nitrogen fixation rates in oligotrophic subtropical gyres (Tagliabue et al., 2017 and references therein). Regions of known elevated dust deposition (e.g., the subtropical North Atlantic; Sedwick et al., 2005; Buck et al., 2010) would be expected to exhibit large dissolved metal gradients at concentrations significantly above other open ocean locations, thereby facilitating the establishment of new sensor systems. High-resolution autonomous surface mapping in these regions could improve understanding of the variables affecting metal dissolution including rainfall, dry deposition, and the sea surface microlayer, all of which are currently not well understood given the paucity of data at appropriate spatial and temporal resolution (Baker et al., 2016). Such measurements could also allow examination of the residence time of Fe in the surface ocean and the impact of deposition events on biological activity.

Although not a bioactive trace metal micronutrient, aluminium (Al) is considered a good proxy for dust deposition and thus the input of Fe to the surface ocean (Measures and Vink, 2000; Grand et al., 2015a; Anderson et al., 2016). The residence time of Al is considerably longer than that of Fe, but much shorter than that of Mn, suggesting that it reflects Fe inputs on a daily-to-annual time scale. Current benchtop analytical techniques (e.g., Resing and Measures, 1994) are sensitive enough to analyze Al in areas of intense dust deposition without a preconcentration step, making the development of an Al sensor for these areas an interesting proposition. Such a sensor would certainly complement any new Fe sensor and would provide a data set to evaluate changes in Fe inputs. This vision could be achieved within a decade, for example, by deploying Fe and Al analyzers on autonomous surface sampling vehicles, such as Wave Gliders and Sail Drones, for month-long missions. Sail Drones are perhaps most amenable to hosting prototype in situ wet chemical analyzers due to their power availability, size, and availability of dry instrument space above the water line (Voosen, 2018).

Time Series

Metal micronutrient time series are rare. They are mainly focused on Fe, of limited temporal resolution and difficult to maintain over the time period needed to decipher seasonal variations, episodic events, and their impact on marine ecosystem dynamics (Boyle et al., 2005; Sedwick et al., 2005; Nishioka et al., 2011; Fitzsimmons et al., 2015; Barrett et al., 2015). Developing the capacity to instrument coastal and open ocean time-series sites, which are well characterized and visited on a regular basis for sampling and servicing (e.g., BATS, HOT, CalCOFI), would be a very desirable outcome in the decade following OceanObs’19. Ocean observing sites that are already instrumented with a mooring would be a good place to start (e.g., Ocean Station Papa, OOI Endurance Array) considering that power-hungry analyzers with relatively large payloads could be deployed and serviced at regular intervals during their development stages.

While the ultimate goal is to develop the capacity to monitor bioactive trace elements in situ at sub-nanomolar concentrations in open ocean settings, obtaining long-term datasets in areas that are not as challenging analytically (in terms of detection limits) and logistically (in terms of remoteness) constitutes an obvious first step. In this regard, acquiring time-series records in coastal regions experiencing seasonal upwelling (e.g., Monterey Bay; Elrod et al., 2008) and typically showing enhanced metal concentrations would be logistically ideal locations. Newly developed sensors/analyzers/samplers can be tested and validated (e.g., Geißler et al., 2017), integrated with other biogeochemical sensors (e.g., macronutrients, Imaging FlowCytobot), and be potentially used to investigate how bioactive metal micronutrient availability influences domoic acid production and the onset of harmful algal blooms in coastal regions (Maldonado et al., 2002). In addition, the GEOTRACES community could capitalize on existing micronutrient analyzer prototypes to improve quantification of metal fluxes at interfaces (e.g., Figure 2; Laës-Huon et al., 2016). For example, the temporal variability of hydrothermal emissions, plume chemical speciation, and distal transport of Fe could be explored further using a series of analyzers deployed in the wake of a vent system (Waeles et al., 2017). Metal fluxes from reducing sediments and the metal dynamics in oxygen minimum zones characterized by elevated metal concentrations could also be explored. For example, trace metal sensors could be integrated with existing ocean observing assets, such as the long-term time sampling program in Saanich Inlet (BC, Canada), a low-oxygen fjord, with monthly monitoring measurements, and a VENUS cabled observatory (Ocean Networks Canada). The implementation of such systems should be easily accomplished as it has already been performed on one of the deepest parts of the Ocean Networks Canada (Grotto Hydrothermal Vent, Endeavour Field, 2186 m) from 2011 and 2013 to collect iron concentrations (CHEMINI in situ analyzer) and to link them to the chemosynthetic environment and its related fauna (Cuvelier et al., 2014, 2017).

Conclusion and Recommendations

Trace metal biogeochemistry is integral to our understanding of marine biogeochemical cycling and ocean productivity. The next decade offers the opportunity to capitalize on the findings of the GEOTRACES program, and the growing Ocean Observatories Initiative (assets, autonomous vehicles) to investigate processes and regions at the spatial and temporal resolution necessary to constrain fluxes, residence times, and biological and chemical responses to varying metal inputs and distributions in a changing ocean. Capitalizing on this opportunity, however, requires the development of sensors capable of measuring trace metal micronutrients at levels found in the open ocean. In the next decade, we can make progress with the development of techniques with increased sensitivity and sensor support infrastructure. In addition, we can deploy existing flow techniques, electrochemical methods, and passive samplers on dry platforms including moorings, Sail Drones, autonomous underwater vehicles, ocean observing assets, and ships of opportunity.

To meet this opportunity, however, significant resources must be invested to accomplish goals on several fronts. The first is the improvement in the analytical sensitivity of existing sensors, chemical analyzers, and their underlying chemistries. Novel chemical assays must be developed for those underlying chemistries that employ stable reagents and that are insensitive to temperature variations. Secondly, we must reduce sensor size and power requirements. In addition to deploying existing techniques, it is essential to develop an open-source “DIY” infrastructure to allow ease of sensor development and a mechanism by which scientists can rapidly adapt commercially available technology to in situ applications. Finally, to meet this opportunity, sensor technologies will need to demonstrate the endurance and comparability of in situ sensor data with established techniques in controlled lab conditions. Each of these areas will best be served through interdisciplinary collaborations/joint proposals with government, industry, or academic partners. The creation of an international working group of trace metal sensor developers facilitating regular meetings and workshops and involving the engineering, oceanographic, and analytical chemistry communities could accelerate the delivery of new technology that can be applied to in situ metal determinations in the decade following OceanObs’19.

It should be noted that no sensor is likely to be appropriate for every application. Thus, at this stage, no particular technology should be preferred over another. For example, while wet chemical techniques may ultimately provide the best sensitivity for open-ocean applications, such sensors will be limited by their longevity in the field and may not be applicable to autonomous profilers that are not recovered, due to power usage and analytical throughputs incompatible with profiling rates (i.e., Argo floats). In this regard, recent developments in analytical chemistry (novel ligands, fluorophores, ionophores, biosensors, miniaturized methods) should be regularly evaluated for their oceanographic potential.

The development of the discussed technologies are of great benefit to society as they will allow an ever greater understanding of ocean and climate feedbacks associated with the input and cycling of trace elements in the ocean. Ocean sampling programs such as GEOTRACES are vastly improving the understanding of dynamics of trace elements and in many instances allow understanding and identification of processes for the first time, in addition to prompting reconsideration of historical paradigms (e.g., Resing et al., 2015). This is largely due to the collaborative nature of these projects that make concurrent observations of multiple trace elements and relevant biogeochemical data over large sections of the world’s ocean. These large-scale discrete measurements also provide much desired information on trace metal sources and sinks. However, these ocean sections do not provide a full measure of spatial variability and no measure of temporal variability that we expect in situ sensors to provide.

Understanding trace metal dynamics has a wide range of applications, including improving our understanding of oceanic water mass circulation, surveying, and understanding toxic metal plumes and algae. Spatial and temporal observations by micronutrient metal sensors will facilitate significant improvements of numerical models that predict carbon uptake and export to the deep ocean, and thus will provide a better understanding of the role of the ocean in regulating climate. Trace metals are also of societal concern, as they may reflect pollution and in some cases their presence may be detrimental to the base of the food web. Such pollution can occur in coastal regions, as well as the open ocean through dust deposition. By understanding the variability of trace metals we can better understand their impacts on phytoplankton species composition, including the presence of harmful algae blooms. Ultimately, ecosystem management will be better informed by the addition of high-quality data that is rapidly produced and readily available on meaningful time scales.

Statements

Author contributions

MG coordinated with all co-authors with regard to the structure and contents of this review manuscript and led the writing effort. All co-authors contributed to a preliminary outline supplied by MG, to the writing and editing of previous versions of this manuscript, and gave final approval for publication. AT compiled the global database of dissolved measurements in the ocean that are used to create Figure 1.

Funding

GL acknowledges support from the Chemical Oceanography Program of NSF (OCE-1558738). JR was supported by the Joint Institute for the Study of the Atmosphere and Ocean (JISAO) under NOAA Cooperative Agreement NA15OAR432 0063.

Acknowledgments

We thank Ed Urban and Maite Maldonado for launching this contribution to OceanObs’19 and for editing an earlier version of this manuscript. This is JISAO publication #2018-0177 and PMEL #4887.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

References

  • 1

    AchterbergE. P.BraungardtC. (1999). Stripping voltammetry for the determination of trace metal speciation and in-situ measurements of trace metal distributions in marine waters.Anal. Chim. Acta400381397. 10.1016/S0003-2670(99)00619-4

  • 2

    AchterbergE. P.van den BergC. M. G. (1994). In-line ultraviolet-digestion of natural water samples for trace metal determination using an automated voltammetric system.Anal. Chim. Acta291213232. 10.1016/0003-2670(94)80017-0

  • 3

    AchterbergE. P.van den BergC. M. G. (1996). Automated monitoring of Ni, Cu and Zn in the Irish Sea.Mar. Pollut. Bull.32471479. 10.1016/0025-326X(96)84963-0

  • 4

    AlmeidaM. I. G. S.CattrallR. W.KolevS. D. (2017). Polymer inclusion membranes (PIMs) in chemical analysis – A review.Anal. Chim. Acta987114. 10.1016/J.ACA.2017.07.032

  • 5

    AndersonR. F.ChengH.EdwardsR. L.FleisherM. Q.HayesC. T.HuangK.-F.et al (2016). How well can we quantify dust deposition to the ocean?Philos. Trans. A Math. Phys. Eng. Sci.374:20150285. 10.1098/rsta.2015.0285

  • 6

    BaeyensW.BowieA. R.BuesselerK.ElskensM.GaoY.LamborgC.et al (2011). Size-fractionated labile trace elements in the Northwest Pacific and Southern Oceans.Mar. Chem.126108113. 10.1016/j.marchem.2011.04.004

  • 7

    BaeyensW.GaoY.DavisonW.GalceranJ.LeermakersM.PuyJ.et al (2018). In situ measurements of micronutrient dynamics in open seawater show that complex dissociation rates may limit diatom growth.Sci. Rep.8:16125. 10.1038/s41598-018-34465-w

  • 8

    BarrettP. M.ResingJ. A.BuckN. J.LandingW. M.MortonP. L.ShelleyR. U. (2015). Changes in the distribution of Al and Fe in the eastern North Atlantic Ocean 2003-2013: implications for trends in dust deposition.Mar. Chem.1775768. 10.1016/j.marchem.2015.02.009

  • 9

    BeatonA. D.CardwellC. L.ThomasR. S.SiebenV. J.LegiretF.-E.WaughE. M.et al (2012). Lab-on-chip measurement of nitrate and nitrite for in situ analysis of natural waters.Environ. Sci. Technol.4695489556. 10.1021/es300419u

  • 10

    BellJ.BettsJ.BoyleE. A. (2002). MITESS: a moored in situ trace element serial sampler for deep-sea moorings.Deep Sea Res. I4921032118. 10.1016/S0967-0637(02)00126-7

  • 11

    BillerD. V.BrulandK. W. (2012). Analysis of Mn, Fe, Co, Ni, Cu, Zn, Cd, and Pb in seawater using the Nobias-chelate PA1 resin and magnetic sector inductively coupled plasma mass spectrometry (ICP-MS).Mar. Chem.131220. 10.1016/j.marchem.2011.12.001

  • 12

    BowieA. R.AchterbergE. P.MantouraR. F. C.WorsfoldP. J. (1998). Determination of sub-nanomolar levels of iron in seawater using flow injection with chemiluminescence detection.Anal. Chim. Acta361189200. 10.1016/S0003-2670(98)00015-4

  • 13

    BowieA. R.AchterbergE. P.SedwickP. N.and. WorsfoldP. J. (2002). Real-time monitoring of picomolar concentrations of Iron(II) in marine waters using automated flow injection-chemiluminescence instrumentation.Environ. Sci. Tech.3646004607. 10.1021/ES020045V

  • 14

    BoyleE. A.BergquistB. A.KayserR. A. R.MahowaldN. (2005). Iron, manganese, and lead at Hawaii Ocean time-series station ALOHA: temporal variability and an intermediate water hydrothermal plume.Geochim. Cosmochim. Acta69933952. 10.1016/j.gca.2004.07.034

  • 15

    BraungardtC. B.AchterbergE. P.AxelssonB.BuffleJ.GraziottinF.HowellK. A.et al (2009). Analysis of dissolved metal fractions in coastal waters: an inter-comparison of five voltammetric in situ profiling (VIP) systems.Mar. Chem.1144755. 10.1016/j.marchem.2009.03.006

  • 16

    BrulandK. W.MiddagR.LohanM. C. (2014). Controls of trace metals in seawater.Treatise Geochem.62347. 10.1016/B978-0-08-095975-7.00602-1

  • 17

    BuckC. S.LandingW. M.ResingJ. A.MeasuresC. I. (2010). The solubility and deposition of aerosol Fe and other trace elements in the North Atlantic Ocean: observations from the A16N CLIVAR/CO2 repeat hydrography section.Mar. Chem.1205770. 10.1016/j.marchem.2008.08.003

  • 18

    CathalotC.HellerM. I.DulaquaisG.WaelesM.CoailJ. -Y.KerboulA.et al (2017). ELVIDOR- vibrating gold micro-wire electrode: In situ high resolution measurements of Copper in marine environments, Goldschmidt Abstracts,584.

  • 19

    ChapinT. P.JannaschH. W.JohnsonK. S. (2002). In situ osmotic analyzer for the year-long continuous determination of Fe in hydrothermal systems.Anal. Chim. Acta463265274. 10.1016/S0003-2670(02)00423-3

  • 20

    ChapmanC. S.CookeR. D.SalaünP.van den BergC. M. G. (2012). Apparatus for in situ monitoring of copper in coastal waters.J. Environ. Monit.1427932802. 10.1039/c2em30460k

  • 21

    ChinC. S.CoaleK. H.ElrodV. A.JohnsonK. S.MassothG. J.BakerE. T. (1994). In situ observations of dissolved iron and manganese in hydrothermal vent plumes, Juan de Fuca Ridge.J. Geophys. Res. Solid Earth9949694984. 10.1029/93JB02036

  • 22

    ChinC. S.JohnsonK. S.CoaleK. H. (1992). Spectrophotometric determination of dissolved manganese in natural waters with 1-(2-pyridylazo)-2-naphthol: application to analysis in situ in hydrothermal plumes.Mar. Chem.376582. 10.1016/0304-4203(92)90057-H

  • 23

    Clinton-BaileyG.BeatonA.NightingaleA.OwsiankaD.SlavikG.et al (2017). A lab-on-chip analyzer for in situ measurement of soluble reactive phosphate: improved phosphate blue assay and application to fluvial monitoring.Environ. Sci. Technol.5199899995. 10.1021/acs.est.7b01581

  • 24

    CoaleK. H.JohnsonK. S.FitzwaterS. E.GordonR. M.TannerS.ChavezF. P.et al (1996). A massive phytoplankton bloom induced by an ecosystem-scale iron fertilization experiment in the equatorial Pacific Ocean.Nature383495501. 10.1038/383495a0

  • 25

    CowenJ. P.CopsonD. A.JollyJ.HsiehC.-C.LinH.-T.GlazerB. T.WheatC. G. (2012). Advanced instrument system for real-time and time-series microbial geochemical sampling of the deep (basaltic) crustal biosphere.Deep-Sea Res. I614356. 10.1016/j.dsr.2011.11.004

  • 26

    CrootP. L.MoffettJ. W.LutherG. W.III (1999). Polarographic determination of half-wave potentials for copper-organic complexes in seawater.Mar. Chem.67219232. 10.1016/S0304-4203(99)00054-7

  • 27

    CutterG. A.BrulandK. W. (2012). Rapid and non contaminating sampling system for trace elements in global ocean surveys.Limnol. Oceanogr. Methods10425436. 10.4319/lom.2012.10.425

  • 28

    CuvelierD.LegendreP.LaësA.SarradinP. M.SarrazinJ. (2014). Rhythms and community dynamics of a hydrothermal tubeworm assemblage at main endeavour field – A multidisciplinary deep-sea observatory approach.PLoS One9:e96924. 10.1371/journal.pone.0096924

  • 29

    CuvelierD.LegendreP.Laës-HuonA.SarradinP. M.SarrazinJ. (2017). Biological and environmental rhythms in (dark) deep-sea hydrothermal ecosystems.Biogeosciences1429552977. 10.5194/bg-14-2955-2017

  • 30

    DanielA.BakerA. R.van den BergC. M. G. (1997). Sequential flow analysis coupled with ACSV for on-line monitoring of cobalt in the marine environment.Fresenius J. Anal. Chem.358703710. 10.1007/s002160050495

  • 31

    de BaarH. J. W. H.TimmermansK. K. R.LaanP.de PortoH. H. H.OberS.BlomJ. J. J.et al (2007). Titan: a new facility for ultraclean sampling of trace elements and isotopes in the deep oceans in the international Geotraces program.Mar. Chem.111421. 10.1016/j.marchem.2007.07.009

  • 32

    DeloryE.PearlmanJ. (2018). Challenges and Innovations in Ocean In Situ Sensors.Amsterdam: Elsevier Science.

  • 33

    DeppelerS. L.DavidsonA. T. (2017), Southern Ocean phytoplankton in a changing climate.Front. Mar. Sci.4:40. 10.3389/fmars.2017.00040

  • 34

    DoiT.TakanoM.OkamuraK.UraT.GamoT. (2008). In-situ survey of nanomolar manganese in seawater using an autonomous underwater vehicle around a volcanic crater at Teishi Knoll, Sagami Bay, Japan.J. Oceanogr.64471477. 10.1007/s10872-008-0040-2

  • 35

    ElrodV. A.JohnsonK. S.CoaleK. H. (1991). Determination of subnanomolar levels of iron(II) and toal dissolved iron in seawater by flow-injection analysis with chemiluminescence detection.Anal. Chem.63893898. 10.1021/ac00009a011

  • 36

    ElrodV. A.JohnsonK. S.FitzwaterS. E.PlantJ. N. (2008). A long-term, high-resolution record of surface water iron concentrations in the upwelling-driven central California region.J. Geophys. Res.113:C11021. 10.1029/2007JC004610

  • 37

    FitzsimmonsJ. N.HayesC. T.Al-SubiaiS. N.ZhangR.MortonP. L.WeisendR. E.et al (2015). Daily to decadal variability of size-fractionated iron and iron-binding ligands at the Hawaii Ocean Time-series Station ALOHA.Geochim. Cosmochim. Acta171303324. 10.1016/J.GCA.2015.08.012

  • 38

    FloorG. H.CloughR.LohanM. C.UssherS. J.WorsfoldP. J.QuételC. R. (2015). Combined uncertainty estimation for the determination of the dissolved iron amount content in seawater using flow injection with chemiluminescence detection.Limnol. Oceanogr. Methods13673686. 10.1002/lom3.10057

  • 39

    GamoT.OkamuraK.MitsuzawaK.AsakawaK. (2007). Tectonic pumping: earthquake-induced chemical flux detected in situ by a submarine cable experiment in Sagami Bay, Japan.Proc. Jpn. Acad. B-Phys.83199204. 10.2183/pjab/83.199

  • 40

    GeißlerF.AchterbergE. P.BeatonA. D.HopwoodM. J.ClarkeJ. S.MutzbergA.et al (2017). Evaluation of a ferrozine based autonomous in situ lab-on-chip analyzer for dissolved iron species in coastal waters.Front. Mar. Sci.4:322. 10.3389/fmars.2017.00322

  • 41

    Gibbon-WalshK.SalaunP.van den BergC. M. G. (2012). Pseudopolarography of copper complexes in seawater using a vibrating gold microwire electrode.J. Phys. Chem. A11666096620. 10.1021/jp3019155

  • 42

    GrandM. M.ChocholoušP.RùžièkaJ.SolichP.MeasuresC. I. (2016). Determination of trace zinc in seawater by coupling solid phase extraction and fluorescence detection in the Lab-On-Valve format.Anal. Chim. Acta9234554. 10.1016/j.aca.2016.03.056

  • 43

    GrandM. M.Clinton-BaileyG. S.BeatonA. D.SchaapA. M.JohengenT. H.TamburriM. N.et al (2017). A lab-on-chip phosphate analyzer for long-term In Situ monitoring at fixed observatories: optimization and performance evaluation in estuarine and oligotrophic coastal waters.Front. Mar. Sci.4:255. 10.3389/fmars.2017.00255

  • 44

    GrandM. M.MeasuresC. I.HattaM.HiscockW. T.BuckC. S.LandingW. M. (2015a). Dust deposition in the eastern Indian Ocean: the ocean perspective from Antarctica to the Bay of Bengal.Global Biogeochem. Cycles29357374. 10.1002/2014GB004898

  • 45

    GrandM. M.MeasuresC. I.HattaM.MortonP. L.BarrettP.MilneA.et al (2015b). The impact of circulation and dust deposition in controlling the distributions of dissolved Fe and Al in the south Indian subtropical gyre.Mar. Chem.176110125. 10.1016/j.marchem.2015.08.002

  • 46

    HoT. Y.QuiggA.FinkelZ. V.MilliganA. J.WymanK.FalkowskiP.et al (2003). The elemental composition of some marine phytoplankton. J.Phycol.3911451159. 10.1111/j.0022-3646.2003.03-090.x

  • 47

    HolmC. E.ChaseZ.JannaschH. W.JohnsonK. S. (2008). Development and initial deployments of an autonomous in situ instrument for long-term monitoring of copper (II) in the marine environment.Limnol. Oceanogr. Methods6336346. 10.4319/lom.2008.6.336

  • 48

    JohnsonK. S.BeehlerC. L.Sakamoto-ArnoldC. M. (1986). A submersible flow analysis system.Anal. Chim. Acta179245257. 10.1016/S0003-2670(00)84469-4

  • 49

    JordiA.BasterretxeaG.Tovar-SánchezA.AlastueyA.QuerolX. (2012). Copper aerosols inhibit phytoplankton growth in the Mediterranean Sea.Proc. Natl. Acad. Sci. U.S.A.1092124621249. 10.1073/pnas.1207567110

  • 50

    KimT.ObataH.NishiokaJ.GamoT. (2017). Distribution of dissolved zinc in the western and central subarctic North Pacific.Global Biogeochem. Cycles3114541468. 10.1002/2017GB005711

  • 51

    KlinkhammerG. P. (1994). Fiber optic spectrometers for in-situ measurements in the oceans: the ZAPS Probe.Mar. Chem.471320. 10.1016/0304-4203(94)90010-8

  • 52

    KlunderM. B.LaanP.MiddagR.De BaarH. J. W.van OoijenJ. C.OoijenJ. V. (2011). Dissolved iron in the Southern Ocean (Atlantic sector).Deep Sea Res. Part II Top. Stud. Oceanogr.5826782694. 10.1016/j.dsr2.2010.10.042

  • 53

    LaësA.BlainS.LaanP.UssherS. J.AchterbergE. P.TréguerP.et al (2007). Sources and transport of dissolved iron and manganese along the continental margin of the Bay of Biscay.Biogeosciences4181194. 10.5194/bg-4-181-2007

  • 54

    LaësA.LeildeB.SarthouG.Bournot-MarecC.BlainS. (2005). Impact of environmental factors on in situ determination of iron in seawater by flow injection analysis.Mar. Chem.97347356. 10.1016/j.marchem.2005.06.002

  • 55

    Laës-HuonA.CathalotC.LegrandJ.TanguyV.SarradinP. M. (2016). Long-Term in situ survey of reactive iron concentrations at the Emso-Azores observatory.IEEE J. Ocean. Eng.41744752. 10.1109/JOE.2016.2552779

  • 56

    LagerströmM. E.FieldM. P.SéguretM.FischerL.HannS.SherrellR. M. (2013). Automated on-line flow-injection ICP-MS determination of trace metals (Mn, Fe, Co, Ni, Cu and Zn) in open ocean seawater: application to the GEOTRACES program.Mar. Chem.1557180. 10.1016/j.marchem.2013.06.001

  • 57

    LinM.HuaX.PanaD.HanH. (2018). Determination of iron in seawater: from the laboratory to in situ measurements.Talanta188135144. 10.1016/j.talanta.2018.05.071

  • 58

    LutherG. W.IIIGlazerB. T.MaS.TrouwborstR. E.MooreT. S.MetzgerE.et al (2008). Use of voltammetric solid-state (micro)electrodes for studying biogeochemical processes: laboratory measurements to real time measurements with an in situ electrochemical analyzer (ISEA).Mar. Chem.108221235. 10.1016/j.marchem.2007.03.002

  • 59

    MaldonadoM. T.HughesM. P.RueE. L.WellsM. L. (2002). The effect of Fe and Cu on growth and domoic acid production by Pseudo-nitzschia multiseries and Pseudo-nitzschia australis.Limnol. Oceanogr.47515526. 10.4319/lo.2002.47.2.0515

  • 60

    MannE. L.AhlgrenN.MoffettJ. W.ChisholmS. W. (2002). Copper toxicity and cyanobacteria ecology in the Sargasso Sea.Limnol. Oceanogr.47976988. 10.4319/lo.2002.47.4.0976

  • 61

    MartinJ. H.FitzwaterS. (1988). Iron deficiency limits phytoplankton growth in the north-east Pacific subarctic.Nature331341343. 10.1038/331341a0

  • 62

    MartinJ. H.GordonM. R. (1988). Northeast Pacific iron distributions in relation to phytoplankton productivity. Deep Sea Res. Part A.Oceanogr. Res. Pap.35177196. 10.1016/0198-0149(88)90035-0

  • 63

    MassothG. A. (1991). SUAVE (submersible system used to assess vented emissions) approach to plume sensing: the buoyant plume experiment at cleft segment.Eos Trans. Am. Geophys. Union72:234.

  • 64

    MeasuresC. I.LandingW. M.BrownM. T.BuckC. S. (2008). A commercially available rosette system for trace metal clean sampling.Limnol. Oceanogr. Methods6384394. 10.4319/lom.2008.6.384

  • 65

    MeasuresC. I.VinkS. (2000). On the use of dissolved aluminium in surface waters to estimate dust deposition to the ocean.Global Biogeochem. Cycles14317327. 10.1029/1999GB001188

  • 66

    MeasuresC. I.YuanJ.ResingJ. A. (1995). Determination of iron in seawater by flow injection-analysis using in-line preconcentration and spectrophotometric detection.Mar. Chem.50312. 10.1016/0304-4203(95)00022-J

  • 67

    MilaniA.StathamP. J.MowlemM. C.ConnellyD. P. (2015). Development and application of a microfluidic in-situ analyzer for dissolved Fe and Mn in natural waters.Talanta1361522. 10.1016/j.talanta.2014.12.045

  • 68

    MilneA.LandingW.BizimisM.MortonP. (2010). Determination of Mn, Fe, Co, Ni, Cu, Zn, Cd and Pb in seawater using high resolution magnetic sector inductively coupled mass spectrometry (HR-ICP-MS).Anal. Chim. Acta665200207. 10.1016/j.aca.2010.03.027

  • 69

    MinamiT.KonagayaW.ZhengL.TakanoS.SasakiM.MurataR.et al (2015). An off-line automated preconcentration system with ethylenediaminetriacetate chelating resin for the determination of trace metals in seawater by high-resolution inductively coupled plasma mass spectrometry.Anal. Chim. Acta854183190. 10.1016/j.aca.2014.11.016

  • 70

    MuellerA.CrusiusJ.AgudeloA.ShaikhF. (2018). “A novel high-resolution trace metal clean sampler for stationary, profiling, and mobile deployment,” inProceedings of the IEEE Sensors: Special Issue IEEE/MTS Oceans Conference 2018 (Piscataway, NJ: IEEE). 10.1109/OCEANSKOBE.2018.8559270

  • 71

    NielsdóttirM. C.MooreC. M.SandersR.HinzD. J.AchterbergE. P. (2009). Iron limitation of the postbloom phytoplankton communities in the Iceland Basin.Global Biogeochem. Cycles23:GB3001. 10.1029/2008gb003410

  • 72

    NishiokaJ.OnoT.SaitoH.NakatsukaT.TakedaS.YoshimuraT.et al (2007). Iron supply to the western subarctic Pacific: importance of iron export from the Sea of Okhotsk.J. Geophys. Res. Oceans112:C10012. 10.1029/2006JC004055

  • 73

    NishiokaJ.OnoT.SaitoH.SakaokaK.YoshimuraT. (2011). Oceanic iron supply mechanisms which support the spring diatom bloom in the Oyashio region, western subarctic Pacific.J. Geophys. Res. Oceans116:C02021. 10.1029/2010JC006321

  • 74

    NowickiJ. L.JohnsonK. S.CoaleK. H.ElrodV. A.LiebermanS. H. (1994). Determination of zinc in seawater using flow-injection analysis with fluorometric detection.Anal. Chem.6627322738. 10.1021/ac00089a021

  • 75

    ObataH.KarataniH.NakayamaE. (1993). Automated-determination of iron in seawater by chelating resin concentration and chemiluminescence detection.Anal. Chem.6515241528. 10.1021/ac00059a007

  • 76

    OkamuraK.KimotoH.SaekiK.IshibashiJ.ObataH.MaruoM.et al (2001). Development of a deep-sea in situ Mn analyzer and its application for hydrothermal plume observation.Mar. Chem.20011726. 10.1016/S0304-4203(01)00043-3

  • 77

    OkamuraK.NoguchiT.HattaM.SunamuraM.SuzueT.KimotoH.et al (2013). Development of a 128-channel multi-water-sampling system for underwater platforms and its application to chemical and biological monitoring.Methods Oceanogr.87590. 10.1016/J.MIO.2014.02.001

  • 78

    OliveiraH. M.GrandM. M.RuzickaJ.MeasuresC. I. (2015). Towards chemiluminescence detection in micro-sequential injection lab-on-valve format: a proof of concept based on the reaction between Fe(II) and luminol in seawater.Talanta133107111. 10.1016/j.talanta.2014.06.076

  • 79

    RappI.SchlosserC.RusieckaD.GledhillM.AchterbergE. P. (2017). Automated preconcentration of Fe, Zn, Cu, Ni, Cd, Pb, Co, and Mn in seawater with analysis using high-resolution sector field inductively-coupled plasma mass spectrometry.Anal. Chim. Acta976113. 10.1016/j.aca.2017.05.008

  • 80

    ResingJ. A.MeasuresC. I. (1994). Fluorometric determination of Al in seawater by flow injection analysis with in-line preconcentration.Anal. Chem.6641054111. 10.1021/ac00094a039

  • 81

    ResingJ. A.MottlM. J. (1992). Determination of manganese in seawater by flow injection analysis using online preconcentration and spectrophotometric detection.Anal. Chem.6426822687. 10.1021/ac00046a006

  • 82

    ResingJ. A.SedwickP. N.GermanC. R.JenkinsW. J.MoffettJ. W.SohstB. M.et al (2015). Basin-scale transport of hydrothermal dissolved metals across the South Pacific Ocean.Nature523200203. 10.1038/nature14577

  • 83

    RijkenbergM. J. A.SlagterH. A.Rutgers van der LoeffM.van OoijenJ.GerringaL. J. A. (2018). Dissolved fe in the deep and upper arctic ocean with a focus on fe limitation in the nansen basin.Front. Mar. Sci.5:88. 10.3389/fmars.2018.00088

  • 84

    RozanT. F.LutherG. W.RidgeD.IIIRobinsonS. (2003). Determination of Pb complexation in oxic and sulfidic waters using Pseudovoltammetry.Environ. Sci. Technol.3738453852. 10.1021/es034014r

  • 85

    Ryan-KeoghT. J.MaceyA. I.NielsdóttirM. C.LucasM. I.SteigenbergerS. S.StinchcombeM. C.et al (2013). Spatial and temporal development of phytoplankton iron stress in relation to bloom dynamics in the high-latitude North Atlantic Ocean.Limnol. Oceanogr.58533545. 10.4319/lo.2013.58.2.0533

  • 86

    SarradinP. M.Le BrisN.Le GallC.RodierP. (2005). Fe analysis by the ferrozine method: adaptation to FIA towards in situ analysis in hydrothermal environment.Talanta6611311138. 10.1016/j.talanta.2005.01.012

  • 87

    SchlitzerR.AndersonR. F.DodasE. M.LohanM.GeibertW.TagliabueA.et al (2018). The GEOTRACES intermediate data product 2017.Chem. Geol.493210223. 10.1016/J.CHEMGEO.2018.05.040

  • 88

    SedwickP. N.ChurchT. M.BowieA. R.MarsayC. M.UssherS. J.AchillesK. M.et al (2005). Iron in the Sargasso Sea (Bermuda Atlantic Time-series Study region) during summer: eolian imprint, spatiotemporal variability, and ecological implications.Global Biogeochem. Cycles19:GB4006. 10.1029/2004GB002445

  • 89

    ShelleyR. U.ZachhuberB.SedwickP. N.WorsfoldP. J.LohanM. C. (2010). Determination of total dissolved cobalt in UV-irradiated seawater using flow injection with chemiluminescence detection.Limnol. Oceanogr. Methods8352362. 10.4319/lom.2010.8.352

  • 90

    ShivaA. H.BennettW. W.WelshD. T.TeasdaleP. R. (2016). In situ evaluation of DGT techniques for measurement of trace metals in estuarine waters: a comparison of four binding layers with open and restricted diffusive layers. Environ. Sci. Process.Impacts, 185163. 10.1039/C5EM00550G

  • 91

    StathamP. J.ConnellyD. P.GermanC. R.BrandT.OvernellJ. O.BulukinE.et al (2005). Spatially complex distribution of dissolved manganese in a fjord as revealed by high-resolution in situ sensing using the autonomous underwater vehicle autosub.Environ. Sci. Technol.3994409445. 10.1021/es050980t

  • 92

    StathamP. J.ConnellyD. P.GermanC. R.BulukinE.MillardN.McPhailS.et al (2003). Mapping the 3D spatial distribution of dissolved manganese in coastal waters using an in situ analyser and the autonomous underwater vehicle Autosub.Underw. Technol.25129134. 10.3723/175605403783379679

  • 93

    SundaW. G. (2012). Feedback interactions between trace metal nutrients and phytoplankton in the ocean.Front. Microbiol.3:204. 10.3389/fmicb.2012.00204

  • 94

    SundbyB.CaetanoM.ValeCGobeilC.LutherG. W.IIINuzzioD. B. (2005). Root induced cycling of lead in salt marsh sediments.Environ. Sci. Technol.3920802086. 10.1021/es048749n

  • 95

    TagliabueA.AumontO.DeAthR.DunneJ. P.DutkiewiczS.GalbraithE.et al (2016). How well do global ocean biogeochemistry models simulate dissolved iron distributions?Global Biogeochem. Cycles30149174. 10.1002/2015GB005289

  • 96

    TagliabueA.BowieA. R.BoydP. W.BuckK. N.JohnsonK. S.SaitoM. A. (2017). The integral role of iron in ocean biogeochemistry.Nature5435159. 10.1038/nature21058

  • 97

    TagliabueA.MtshaliT.AumontO.BowieA. R.KlunderM. B.RoychoudhuryA. N.et al (2012). A global compilation of dissolved iron measurements: focus on distributions and processes in the Southern Ocean.Biogeosciences923332349. 10.5194/bg-9-2333-2012

  • 98

    Tercier-WaeberM.-L.ConfalonieriF.Koudelka-HepM.Dessureault-RompréJ.GraziottinF.BuffleJ. (2008). Gel-integrated voltammetric microsensors and submersible probes as reliable tools for environmental trace metal analysis and speciation.Electroanalysis20240258. 10.1002/elan.200704067

  • 99

    TwiningB. S.BainesS. B. (2013). The trace metal composition of marine phytoplankton.Annu. Rev. Mar. Sci.5191215. 10.1146/annurev-marine-121211-172322

  • 100

    TwissM. R.MoffettJ. W. (2002). Comparison of copper speciation in coastal marine waters measured using analytical voltammetry and diffusion gradient in thin-film techniques.Environ. Sci. Technol.3610611068. 10.1021/es0016553

  • 101

    TwiningB. S.Nuñez-MillandD.VogtS.JohnsonR. S.SedwickP. N. (2010). Variations in Synechococcus cell quotas of phosphorus, sulfur, manganese, iron, nickel, and zinc within mesoscale eddies in the Sargasso Sea.Limnol. Oceanogr.55492506. 10.4319/lo.2010.55.2.0492

  • 102

    VanceD.LittleS. H.de SouzaG. F.KhatiwalaS.LohanM. C.MiddagR. (2017). Silicon and zinc biogeochemical cycles coupled through the Southern Ocean.Nat. Geosci.10202206. 10.1038/ngeo2890

  • 103

    VincentA. G.PascalR. W.BeatonA. D.WalkJ.HopkinsJ. E.WoodwardE. M. S.et al (2018). Nitrate drawdown during a shelf sea spring bloom revealed using a novel microfluidic in situ chemical sensor deployed within an autonomous underwater glider.Mar. Chem.2052936. 10.1016/J.MARCHEM.2018.07.005

  • 104

    VinkS.BoyleE. A.MeasuresC. I.YuanJ. (2000). Automated high resolution determination of the trace elements iron and aluminium in the surface ocean using a towed Fish coupled to flow injection analysis.Deep Sea Res. I4711411156. 10.1016/S0967-0637(99)00074-6

  • 105

    VoosenP. (2018). Saildrone fleet could help replace aging buoys.Science35910821083. 10.1126/science.359.6380.1082

  • 106

    VuilleminR.Le RouxD.DorvalP.BucasK.SudreauJ. P.HamonM.et al (2009). CHEMINI: a new in situ CHEmical MINIaturized analyzer.Deep Sea Res. Part I: Oceanogr. Res. Pap.5613911399. 10.1016/J.DSR.2009.02.002

  • 107

    WaelesM.CotteL.Pernet-CoudrierB.ChavagnacV.CathalotC.LeleuT.et al (2017). On the early fate of hydrothermal iron at deep-sea vents: a reassessment after in situ filtration.Geophys. Res. Lett.4442334240. 10.1002/2017GL073315

  • 108

    WeeksD. A.BrulandK. W. (2002). Improved method for shipboard determination of iron in seawater by flow injection analysis.Anal. Chim. Acta4532132. 10.1016/S0003-2670(01)01480-5

  • 109

    WestberryT. K.BehrenfeldM. J.SchultzP.DunneJ. P.HiscockM. R.MaritorenaS.et al (2016). Annual cycles of phytoplankton biomass in the subarctic Atlantic and Pacific Ocean.Global Biogeochem. Cycles30175190. 10.1002/2015GB005276

Summary

Keywords

trace metals, micronutrients, in situ chemical analyzers, in situ sensors, GEOTRACES, OceanObs’19, ocean observing time series

Citation

Grand MM, Laes-Huon A, Fietz S, Resing JA, Obata H, Luther III GW, Tagliabue A, Achterberg EP, Middag R, Tovar-Sánchez A and Bowie AR (2019) Developing Autonomous Observing Systems for Micronutrient Trace Metals. Front. Mar. Sci. 6:35. doi: 10.3389/fmars.2019.00035

Received

14 November 2018

Accepted

22 January 2019

Published

21 February 2019

Volume

6 - 2019

Edited by

Amos Tiereyangn Kabo-Bah, University of Energy and Natural Resources, Ghana

Reviewed by

Antonio Cobelo-Garcia, Spanish National Research Council (CSIC), Spain; Miguel Angel Huerta-Diaz, Universidad Autónoma de Baja California, Mexico

Updates

Copyright

*Correspondence: Maxime M. Grand,

This article was submitted to Marine Biogeochemistry, a section of the journal Frontiers in Marine Science

Disclaimer

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Outline

Figures

Cite article

Copy to clipboard


Export citation file


Share article

Article metrics