- 1School of Sport Science, Beijing Sport University, Beijing, China
- 2AI Sports Engineering Lab, School of Sports Engineering, Beijing Sport University, Beijing, China
- 3Sports Data Center of China, Beijing Sport University, Beijing, China
- 4Key Laboratory for Performance Training and Recovery of General Administration of Sport, Beijing Sport University, Beijing, China
- 5Engineering Research Center of Strength and Conditioning Training Key Core Technology Integrated System and Equipment, Ministry of Education, Beijing Sport University, Beijing, China
Background: Inertial measurement units (IMUs) enable portable gait monitoring, yet their accuracy relies on precise event detection. Conventional algorithms using raw signal peaks often fail during running due to speed variations and diverse foot-strike patterns. Therefore, adaptive detection strategies are required for high precision running gait analysis.
Methods: This study proposes MFD-GED (multi-sensor fusion with dynamic gait event detection), a refined method for accurate running gait analysis via a single foot-mounted IMU. To enhance event detection, the framework fuses acceleration- and angular-velocity features and employs a parametric strategy to identify initial contact (IC), terminal contact (TC) and mid-stance (MS), respectively. The algorithm then computes a comprehensive set of gait parameters relevant to running biomechanics assessment. Data were collected from 15 healthy male runners (age: 24.1 ± 1.1 years) performing 10-m running trials. The proposed method was benchmarked against a conventional angular-velocity-based gait-segmentation algorithm (AVGS) and validated using a laboratory reference (LAB) comprising an optical motion-capture and force-plate system. Pearson correlation coefficients (Pearson’s r), intraclass correlation coefficients (ICCs), and Bland-Altman analysis were used to assess concurrent validity, while paired t-tests and Cohen’s d were employed to evaluate the performance improvement over the AVGS method.
Results: The MFD-GED method demonstrated high concurrent validity against the LAB system (r = 0.743–0.991; ICC = 0.741–0.990). Compared to the AVGS method, systematic bias was reduced for spatial parameters (
Conclusion: This study validates an IMU framework improving running gait detection. Through sensor fusion, MFD-GED enables high-fidelity parameter estimation. While lab-validated for healthy young males, findings affirm its potential running for future gait monitoring tasks, aiming to offer a reliable tool for professionals in the field.
1 Introduction
Quantitative gait analysis, a sophisticated method for evaluating human locomotion, serves dual purposes in clinical and sports settings: as a crucial clinical tool for injury prevention and as a performance optimization mechanism for athletes (Wang et al., 2003; Tao et al., 2012; Chen et al., 2012; Sethi et al., 2022). Key gait spatiotemporal and kinetic parameters, such as stride length, step frequency, contact time, flight time, and ground reaction force, are essential for evaluating running injury (Nijs et al., 2022; Watanabe et al., 2023; Mo and Chow, 2018) and performance (Napier et al., 2015; Di Michele and Merni, 2014). Traditionally, gait assessment relies on subjective clinical observations or rating scales, which are often insufficient for detecting subtle changes caused by training, fatigue, or injury (Ferber and Macdonald, 2014). Although gold-standard laboratory methods, such as optical motion capture systems, force plates, and instrumented walkways, offer precise measurements (Muro-De-La-Herran et al., 2014), they require expensive equipment, dedicated spaces, and complex postprocessing, often delaying access to results and decision-making. These limitations hinder their practicality in routine clinical use or real-world sports environments, where capturing biomechanics during actual running or walking is crucial (Norris et al., 2014).
Advances in wearable technology, particularly improvements in the accuracy, sensitivity, and algorithms of inertial measurement units (IMUs), now enable gait measurement in free-living conditions (Tao et al., 2012), enhancing the effectiveness of IMU-based gait analysis systems for evaluating walking and running biomechanics (Reenalda et al., 2019). These wearable IMUs, consisting of tri-axial accelerometers and gyroscopes, enable the computation of specific gait variables and offer a practical alternative because of their compactness and cost-effectiveness (Mason et al., 2023b; Stuart et al., 2021). The accelerations and angular velocities recorded by body-mounted IMUs enable estimation of running temporal, kinematic and kinetic parameters. As running is cyclic, precise identification of key gait events is essential for partitioning continuous data into discrete gait cycles and deriving reliable, widely reported biomechanical and performance descriptors. Evidence from controlled experiments has revealed strong correlations between distinct signal characteristics, such as extrema in angular-velocity signals, and specific gait events, including initial contact (IC), terminal contact (TC), mid-stance (MS), and mid-swing (MSW) (Mariani et al., 2013; Lee and Park, 2011). Several IMU-based methods identify IC and TC events using sensors affixed to the pelvis (Bergamini et al., 2012), shanks (Yang et al., 2022) or feet (Falbriard et al., 2018). In contrast, foot-mounted units consistently yield the most accurate spatiotemporal estimates (Zrenner et al., 2020). Since lower-trunk and shank placements often rely on semi-elastic belts that can slip or detach under running impact forces, compromising the accuracy of derived gait parameters (Chew et al., 2018).
Common approaches for gait event detection from foot-mounted IMUs include rule-based algorithms (Prasanth et al., 2021) like the angular-velocity-based gait-segmentation (AVGS) method (Luo et al., 2024; Fadillioglu et al., 2020), template-based techniques using dynamic time warping (DTW) (Wang et al., 2016), and machine learning methods (Zhang et al., 2019). The latter two approaches, while sophisticated, often lack generalizability, as their performance can be constrained by the subject-specific datasets used for template construction or model training. In contrast, rule-based methods such as AVGS are computationally efficient and widely deployed, but their accuracy is highly sensitive to variations in foot-strike pattern and running speed (Mitschke et al., 2017). For instance, defining IC based on the angular velocity minimum causes the detected event timing to shift progressively earlier as the strike pattern transitions from rearfoot to forefoot, compromising reliability (Mitschke et al., 2017). Similarly, TC detection exhibits a systematic, speed-dependent bias, as changes in running speed alter the underlying kinematic signatures and reduce accuracy (Yang et al., 2022; Falbriard et al., 2018).
Beyond the accurate detection of IC and TC, identifying the MS phase is also critical, particularly for estimating spatial parameters. The MS event is integral to the zero-velocity update (ZUPT) technique, a widely used method for correcting the integral drift that arises when calculating displacement from acceleration data. To identify this stationary phase, many studies employ detectors based on angular rate energy (ARE) (Li and Wang, 2014; Zhang et al., 2017), while others utilize methods such as acceleration moving variance (MV) to analyze signals from both the accelerometer and gyroscope for robust MS identification (Luo et al., 2024). Notably, these studies were based on fixed thresholds or windows, potentially limiting their robustness across different gait patterns and running speeds.
This limitation highlights the need for more adaptive and refined event-detection algorithms to achieve high-accuracy parameter estimation in running gait analysis. To address this, this study introduces a multi-sensor fusion with dynamic gait event detection (MFD-GED) framework. This refined approach is specifically designed to improve the precision of gait event identification and, consequently, deliver more accurate and reliable gait metrics. Leveraging the cyclical nature of running and the periodic structure of inertial signals, the MFD-GED framework integrates multi-sensor fusion of acceleration and angular-velocity features with a parametric event-detection strategy to improve estimation precision. The method extracts eight gait spatiotemporal and kinetic parameters, including stride velocity (SV), stride length (SL), step frequency (SF), stride time (ST), contact time (CT), swing time (SWT), flight time (FT), and peak vertical ground reaction force (vGRF). Then, the concurrent validity of the proposed MFD-GED method was evaluated during a 10-m run test (10MRT). Performance was assessed against two benchmarks: a laboratory reference system (LAB), composed of optical motion capture and three force plates, and the conventional AVGS method, which served as a point of comparison for accuracy. Ultimately, this study aims to demonstrate that the proposed MFD-GED framework enables single foot-mounted IMU to provide gait parameters with an accuracy comparable to laboratory systems, while offering improved robustness over conventional algorithms in real-world running scenarios.
2 Materials and methods
2.1 Algorithm description
2.1.1 Preprocessing
Mounting the IMU at the instep resulted in only a rough alignment with the foot coordinate system. To clarify the sensor orientation, the sensor coordinate system was defined as follows: the x-axis was aligned with the medial-lateral direction, the y-axis with the anterior-posterior direction, and the z-axis with the vertical direction. To establish an initial orientation reference for aligning the body frame with the sensor frame, the gravity vector expressed in the sensor frame was estimated by averaging tri-axial acceleration data recorded during periods of minimal movement, identified as intervals where the angular velocity remained below 0.0436 rad/s. To estimate the gravity direction in the sensor (body) frame, the global gravity vector was rotated using the current orientation quaternion
At each subsequent time step, a parametric correction based on the Mahony complementary filter was employed to compensate for gyroscope drift (Kim et al., 2015). The estimated gravity direction
where
This transformed gravity estimate was then compared with the measured acceleration vector to obtain an error vector
where
A proportional-integral correction framework was applied to update the gyroscope signals using this error. The corrected angular velocity is computed as Equation 4.
where
The orientation quaternion is updated using a second-order approximation as Equation 5.
where
The corrected angular velocity was subsequently used to incrementally update the quaternion representation of orientation via a second-order approximation. Finally, the raw acceleration data in the sensor frame were first rotated into the global frame via quaternion-based transformation
where
Figure 1. Foot-mounted IMU placement (left) and comparison of triaxial acceleration signals (right) before and after coordinate transformation. The top panel shows the raw acceleration in the sensor frame, whereas the bottom panel displays the transformed acceleration in the navigation (global) frame. During stationary phases, the transformed acceleration signals stabilize near 0 g along each axis, confirming proper alignment with the navigation (global) frame.
2.1.2 Gait event detection
Gait is characterized as a stable, quasi-periodic cyclic phenomenon that defines the pattern of bipedal locomotion (Lu et al., 2023). This inherent periodicity manifests in inertial sensor data as quasi-periodic waveforms, which exhibit approximate regularity but possess cycle durations that vary within a specific range. To mitigate noise, both angular velocity and acceleration signals were processed using a fourth-order Butterworth low-pass filter with a 6 Hz cutoff frequency (Hutabarat et al., 2020). Subsequently, gait cycle segmentation was performed using the sagittal-plane angular velocity (
Following gait segmentation, the traditional AVGS algorithm identifies the IC as the negative peak corresponding to the rapid deceleration just before foot strike (Ruiz-Ruiz et al., 2024). A common refinement of this technique employs a zero-crossing rule, which designates IC as the first instant that angular velocity transitions from positive to non-positive (Luo et al., 2024). To build upon these methods and enhance event detection robustness, we introduced the MFD-GED framework. This proposed methodology refines the temporal localization of IC and TC by strategically fusing kinematic and kinetic definitions derived from gyroscope and accelerometer data.
For IC detection, a coarse estimation is initially established using the AVGS method. To enhance precision, a stride-adaptive search window, calculated as 30% of the total stride duration, is centered on this preliminary timestamp. Within this localized temporal domain, the algorithm seeks to reconcile two distinct biomechanical markers: the kinematic marker, defined as the zero-crossing in sagittal angular velocity (
Subsequent to IC identification, the TC event is determined using a similar sensor fusion strategy within a dynamic forward-projected window. The algorithm isolates the kinematic signature of the toe-off mechanism (inflection point in angular velocity) and the corresponding kinetic marker (propulsive peak in acceleration). Recognizing that toe-off involves both rotational kinematics and propulsive kinetics, the final TC timestamp is computed as a weighted average of these two sensor-derived candidates. This differential weighting strategy leverages specific physical characteristics, including the temporal sharpness of the kinetic signal and the phase stability of the kinematic signal, to determine the gait event timestamps (as illustrated in Figure 2).
Figure 2. The proposed gait event detection pipeline using data from foot-mounted IMU. (a) Mid-swing (MSW) detection based on identifying angular velocity peaks that exceed a dynamic threshold. (b) Initial Contact (IC) detection, comparing the outputs of the conventional AVGS, the zero-crossing, and the proposed MFD-GED method. (c) Terminal Contact (TC) detection, comparing the AVGS method with the MFD-GED method. Shaded regions indicate the dynamic search windows for each event.
2.1.3 Zero-velocity detection for segmentation
Building on (Luo et al., 2024), which utilized angular velocity energy and horizontal acceleration variance detectors for MS detection, we introduced a parametric windowing method to improve the detection accuracy. Specifically, for each interval between two consecutive IC and TC events, the first and last 10% of the stance phase were excluded, considering the low probability of mid-stance occurrence in these regions. Within the remaining portion, a sliding window with a size equal to 30% of the stance phase was applied to compute two key metrics: 1) the mean angular velocity energy across the tri-axial gyroscope signals and 2) the variance of horizontal-plane acceleration. The timestamp subsequently corresponds to the minimum angular velocity energy
where
This method combines angular velocity energy and acceleration variance in an adaptive framework to improve the robustness of MS detection. Figure 3 shows the IC, MS, TC, and MSW events within a single gait cycle.
Figure 3. Identification of key gait events within a single running stride using characteristic signals from foot-mounted IMU. The angular velocity (black line) and acceleration (gray line) profiles are used to detect Initial Contact (IC), Mid-Stance (MS), Terminal Contact (TC), and Mid-Swing (MSW). The timing of each event is indicated by a vertical dashed line, with the corresponding foot posture illustrated by the icons below.
2.2 Gait parameter estimation
A complete gait cycle comprises two primary phases: stance and swing (Dugan and Bhat, 2005). Following the identification of IC and TC events, temporal parameters for each cycle are calculated directly from these event timing. These event timestamps were subsequently used to calculate the following temporal parameters, including stride time (ST), contact time (CT), and swing time (SWT). ST, CT, and SWT were calculated as the time from foot strike to foot strike of the same foot, from foot strike to terminal contact of the same foot, from terminal contact to foot strike of the same foot, and from terminal contact of one foot to foot strike of the contralateral foot (Patoz et al., 2022), respectively (see Equation 9).
As the analysis was based on a single foot-mounted IMU, only unilateral gait parameters could be determined. The flight time for the instrumented foot was therefore calculated as Equation 10.
Stride frequency was calculated from the stride time as Equation 11.
The stride length (SL) for each gait cycle was estimated via double integration of acceleration data. Prior to this process, the acceleration signal was transformed from the sensor’s local coordinate system to a global reference frame to nullify the effects of the foot’s changing orientation. The integration was then performed over the interval between consecutive MSW events, yielding velocity after the first integration and the displacement corresponding to SL after the second. However, direct integration may introduce drift, necessitating a correction method. A zero-velocity updating (ZUPT) method was used to mitigate integral drift (Foxlin, 2005), which assumes zero initial acceleration and velocity at each MS point. Preliminary integration was performed to obtain raw velocities, followed by linear drift correction on the basis of the method in (Luo et al., 2024). The endpoint velocity error was linearly distributed across each stride via a weighting function
Figure 4. Effect of the drift-correction algorithm on the three-dimensional velocity profile of the foot over a single gait cycle. The panels display the velocity components in the (a) X, (b) Y, and (c) Z directions. Dashed lines represent the raw velocity obtained from direct integration of acceleration data, which exhibits significant drift error. Solid lines show the corrected velocity.
Then, the SL (
During running, the musculoskeletal system alternately stores and releases elastic energy, enabling the legs to behave like mass-loaded springs. This principle underlies the spring-loaded inverted pendulum (SLIP) model (McMahon and Cheng, 1990), which serves as a biomechanical template for running. The SLIP framework, commonly referred to as the spring-mass model, represents the runner as a point mass atop a single linear spring leg, as illustrated in Figure 5. A sinusoidal function was used to approximate the vertical ground reaction force (vGRF) waveform (Morin et al., 2005), enabling the estimation of the peak vGRF from CT (
where
Figure 5. (a) The spring-loaded inverted pendulum (SLIP) is used as the spring-mass model of running. (b) Measured (solid black line) and estimated (solid red line) vertical ground reaction force‒time waveforms for a single stance phase in one participant. The blue line represents the error, calculated as the discrepancy between the measured and estimated vGRF values. All forces were normalized to body weight (BW).
2.3 Experimental setup and protocol
Fifteen healthy male participants from Beijing Sport University (aged 24.07 ± 1.14 years; body height: 177 ± 6.25 cm; body mass: 75.21 ± 8.02 kg; four forefoot strikes and eleven non-forefoot strike runners) voluntarily participated in this study. We recruited only male participants to control for gender variability in gait (Sardroodian and Hosseinzadeh, 2020). The study was conducted in accordance with the Declaration of Helsinki and approved by the Ethics Committee of Beijing Sport University (protocol code: 2024466H).
During this study, participants wore shoes fitted with a single 9-axis IMU (STAG, Huawei®, Guangdong, China) securely attached to the right instep. To ensure rigid attachment and minimize motion artifacts, the device was secured via a specialized locking foot mount. This mounting mechanism features a hinged clamping base that was inserted beneath two rows of crossed shoelaces and mechanically locked to create a stable anchor point. The sensor unit was then rigidly fastened to the base via a twist-lock interface. The IMU recorded at a sampling rate of 200Hz, and was configured with an accelerometer and a gyroscope range of ±16 g and ±32 rad/s, respectively. During the running test, acceleration and angular velocity data were recorded and transmitted via Bluetooth 5.0 to a mobile phone via the data collection app. A ten-camera high-speed optical motion capture laboratory system (OptiTrack, Natural Point, Corvallis, OR, United States) and three force plates (Kistler, Kistler Instrument Corp.) were used to collect marker data and ground reaction forces (GRFs) simultaneously at 200 Hz and 1,000 Hz, respectively. A total of 19 reflective markers (14 mm diameter) were affixed to specific anatomical landmarks following the OptiTrack Helen Hayes lower-limb marker set protocol. The sites included the sacrum, bilateral anterior superior iliac spines, lateral aspects of the thighs, both lateral and medial knee epicondyles, lateral calves, both lateral and medial malleoli, and the heel and second metatarsal, as shown in Figure 6.
Figure 6. Standardized reference calibration pose setup, placement of reflective markers, IMU on a participant, and layout of the experimental site.
To verify the accuracy of the estimated gait parameters, the study employed a 10-m run test (10MRT) experimental approach (Scivoletto et al., 2011; Castro-Piñero et al., 2023). The 10MRT was selected as it allows participants to achieve a consistent, self-selected running speed, thereby facilitating the capture of representative steady-state gait cycles for biomechanical analysis. Specifically, the concurrent validity of the wearable sensor was evaluated via the LAB system. The participants performed three trials of the 10MRT on a 14-m laboratory track at a self-selected comfortable speed. For each trial, one complete gait cycle with a valid foot strike was captured. Collecting three valid trials aligns with established protocols for gait analysis, ensuring sufficient test-retest reliability for the estimated parameters (Cheng et al., 2020; Santos et al., 2025). Data were simultaneously acquired from both the LAB system and the IMU during these trials.
The marker positions and GRF data collected by the LAB system were filtered via Butterworth fourth-order low-pass filters with cutoff frequencies of 7 Hz (Maiwald et al., 2009) and 25 Hz (Tan et al., 2019), respectively. IC and TC events were identified via a 25 N threshold of vGRF (Hoogkamer et al., 2018). We segment the data collected from the LAB system into individual strides and extract the corresponding gait parameters for comparison with the estimated results obtained from the IMU. Each trial required the participant to target the force plate with the right foot, resulting in three complete gait cycles for comparison. Average measurements were generated as a unified reference for comparison.
2.4 Statistical analysis
Means and SDs were calculated for each gait parameter for each of the two systems over the three running trials. Gait parameter normality was tested via the Shapiro–Wilk test, with
Pearson’s r and ICC values below 0.50 were classified as poor, values between 0.51 and 0.75 as moderate, values between 0.76 and 0.90 as good, and values between 0.91 and 1.00 as excellent (Koo and Li, 2016). Furthermore, the magnitude of the significant changes was analyzed using Cohen’s effect sizes: small effect (d ≥ 0.2), medium effect (d ≥ 0.5), and large effect (d ≥ 0.8) (Cohen, 2013). Statistical significance was set at p < 0.05. Statistical procedures were conducted via SPSS software (v26.0, IBM, Armonk, NY, United States).
3 Results
The gait data of fifteen participants performing running tasks resulted in 360 gait measurements for analysis (15 participants × 8 outcomes × 3 repeats). Normality tests (Shapiro–Wilk) confirmed that gait data from both the single foot-mounted IMU (MFD-GED) and the laboratory system (LAB) followed a normal distribution (
The MFD-GED method demonstrated high concurrent validity with the LAB standards across all measured parameters. As detailed in Table 1, the estimation errors were minimal; specifically, the mean difference for CT was 0.001 ± 0.028 s, and for SL was 0.009 ± 0.072 m. High consistency was further evidenced by the correlation analysis (Table 2), where basic spatiotemporal parameters (SV, SL, SF, ST, CT) achieved correlation coefficients greater than 0.94 and ICCs above 0.90. While the kinetic parameter (peak vGRF) showed a moderate correlation (r = 0.569), the distributional analysis confirms that the MFD-GED method effectively captures the data range and density of the LAB reference (see Figure 7). The Bland-Altman analysis indicated robust agreement, with the majority of data points falling within the 95% LoA (see Figure 8).
Table 2. Descriptive statistics of gait parameters obtained from different methods (i.e., the LAB system and MFD-GED method) in the running protocols and the validity of the IMU method compared with the LAB method (i.e., Pearson’s r and ICCs).
Figure 7. Violin plots comparing eight spatiotemporal and kinetic gait parameters from the LAB system and the proposed MFD-GED method. Gray lines connect paired measurements from individual trials, and the Pearson’s r values for each parameter is displayed above the corresponding panel.
Figure 8. Bland-Altman analysis of agreement between the proposed MFD-GED method and the LAB system for eight spatiotemporal and kinetic gait parameters. In each plot, the solid line indicates the mean difference (bias), and the dashed lines represent the 95% limits of agreement.
Comparing the proposed MFD-GED algorithm with the conventional AVGS method revealed significant improvements in estimation accuracy. As summarized in Table 3, the MFD-GED method yielded consistently lower systematic bias and random error. For spatial parameters, the reduction in bias was not statistically significant (
Figure 9. Validation of (a) SV and (b) SL estimation, comparing the MFD-GED method (red) with AVGS method (gray) against the LAB system. The Pearson correlation and Bland–Altman plots collectively demonstrate that the MFD-GED method yields superior agreement with the standard, as indicated by stronger correlation, reduced measurement bias, and narrower limits of agreement.
Figure 10. Violin plots comparing gait parameter distributions from the LAB, AVGS, and MFD-GED method. Panels display (a) contact time, (b) swing time, (c) flight time, and (d) peak vertical ground reaction force (vGRF). Gray lines connect paired measurements from the same trial, and the corresponding Pearson’s r values.
Figure 11. Linear regression analysis of gait parameters estimated by the proposed MFD-GED method (red) and AVGS method (gray), plotted against the LAB. The four panels compare results for (a) contact time, (b) swing time, (c) flight time, and (d) peak vertical ground reaction force (vGRF). Shaded areas represent the 95% confidence intervals, and the corresponding Pearson’s r values.
4 Discussion
This study presents a refined method for accurate running gait analysis using a single foot-mounted IMU. To improve event detection, we introduce a fusion-based and parametric method for events identification. The method computes comprehensive spatiotemporal and kinetic gait parameters relevant to running performance assessment. We then evaluated the validity of the proposed method by comparing it with the LAB systems consisting of optical motion capture and force plates during the 10MRT. The results confirm that the MFD-GED method achieves high consistency with the laboratory standards, providing a robust tool for running gait analysis.
The comparative analysis demonstrates that the MFD-GED framework significantly outperforms the conventional AVGS algorithm, particularly in minimizing estimation errors for SV and SL. Specifically, the mean error in SV was reduced from −0.023 ± 0.079 m/s (AVGS) to −0.012 ± 0.076 m/s (MFD-GED), and SL error was reduced from 0.018 ± 0.086 m to 0.009 ± 0.072 m (see Table 3). This performance improvement is fundamentally attributed to the robust detection of the MS phase, which is critical for the effective application of the ZUPT algorithm. Direct integration of acceleration data inevitably leads to signal drift. While the previous method uses a fixed 150 ms window (Luo et al., 2024), whereas the MFD-GED parametric method excludes the initial and terminal 10% and applies a 30% sliding window to allow better adaptation to individual gait patterns and supports more robust MS estimation. These improvements are attributed to more accurate MS detection, which improves ZUPT and subsequent parameter estimation. Precise temporal localization of the MS phase ensures that the ZUPT correction is applied exclusively when the foot is mechanically stationary. By mitigating the integration drift that typically accumulates during velocity and position estimation, the proposed method achieves the superior spatial accuracy. This aligns with prior research has highlighted that accurate stance detection is critical for SV and SL estimation because of the application of ZUPT at these points (Zhao et al., 2016).
Furthermore, the MFD-GED method achieved superior accuracy for temporal parameters, including CT, SWT, and FT demonstrating statistically significant improvements across all metrics (
Regarding kinetic parameters, although the consistency of peak vGRF was moderate compared to the other gait parameters (Pearson’s r = 0.569, ICC = 0.502,
Bland–Altman analysis revealed a trend where the LAB system recorded slightly larger values for gait parameters (SV, SL, SF, CT) than the MFD-GED method (Figure 8). This observation aligns with the results from other wearable gait analysis systems (Adams et al., 2016; García-Pinillos et al., 2019; Mason et al., 2023a). Furthermore, a proportional bias was observed in certain parameters (e.g., SF, ST, and CT), where the measurement difference varied systematically with the magnitude of the parameter. Two primary factors likely contribute to both the underestimation and this non-uniform error distribution. First, signal processing methodology plays a critical role. As running speed varies (changing the signal frequency content), a fixed filter may attenuate signal peaks and smooth transitions differently across the range of motion (Miller et al., 2022). Consequently, this may result in temporal drift or slight underestimations of event durations. Second, physical coupling artifacts significantly influence measurement fidelity. Even with secure sensor attachment, residual vibrations relative to the anatomical segment, commonly termed soft tissue artifacts, can inherently introduce minor kinematic deviations (Chapman et al., 2019). Crucially, in high-impact activities, faster running speeds generate larger impact forces, intensifying these micro-movements and further contributing to the trends observed in the error distribution. Despite this, Bland–Altman analysis revealed that almost all the data points fell within the 95% LoA, indicating that the MFD-GED method was generally consistent with the LAB reference.
The quantitative superiority of the MFD-GED framework extends to its methodological robustness and translational utility. Regarding algorithmic robustness, the proposed fusion-based strategy demonstrated superior stability compared to the threshold-based AVGS method, as evidenced by the attenuated error dispersion across key temporal metrics (e.g., CT error SD reduced from 0.041 s to 0.028 s). This reduction in variability indicates that the parametric event detection logic maintains speed-invariant stability, effectively mitigating the signal noise and kinematic artifacts that typically degrade the performance of fixed-threshold algorithms at higher running velocities. From a translational perspective, the elimination of systematic bias is critical for clinical and performance applications. The substantial bias observed in the AVGS method (e.g., 0.057 s for CT) poses a risk of masking clinically relevant gait asymmetries or longitudinal adaptations. In contrast, the MFD-GED method achieved near-zero systematic bias (0.001 s), providing the discriminative sensitivity required to detect subtle temporal deviations. This level of precision is a prerequisite for high-fidelity monitoring in sports medicine, enabling the reliable identification of early-stage fatigue markers or injury risks that would otherwise remain undetectable within the error margins of conventional methods (Kim et al., 2025; Zhang et al., 2025).
Effective IMU-based gait analysis depends on signal processing algorithms to convert raw inertial measurements into interpretable gait parameters (Young et al., 2022). Precise detection of IC and TC points is essential for obtaining reliable spatiotemporal metrics (Benson et al., 2019). Our study supports these principles and reinforces the utility of the foot as an optimal location for such high-precision analysis (Uno et al., 2022). While IMUs are often placed on the trunk (Morris et al., 2019) or shanks (Mancini and Horak, 2016), the instep attachment used in this study offers a distinct advantage for directly capturing foot-ground interaction mechanics. Specifically, the MFD-GED method effectively measures running gait parameters with high accuracy, consistent with validation studies of other wearable devices (He et al., 2024; Yoon et al., 2024). This aligns with the current commercial landscape, where systems such as RunScribe™ (Garcia-Pinillos et al., 2020) and Stryd (García-Pinillos et al., 2021), are mounted on the instep, a convenient and secure location ideal for rapid gait assessment and monitoring during running training. These results confirm that with refined event detection algorithms, a single foot-mounted IMU provides a convenient, secure, and robust solution for rapid gait assessment and monitoring in real-world training environments (Yamamoto et al., 2022; Wang et al., 2020).
The current study has several limitations, which necessitate highlighting areas for future research. First, our study was conducted on a 14 m indoor runway and did not examine changes in gait parameters during prolonged running. While this protocol is clinically validated, its short duration inherently minimizes the accumulation of integral drift, a known limitation of IMU-based spatial analysis. Consequently, the high accuracy observed in this study must be interpreted within the context of short laboratory distances where drift accumulation is minimal. Future studies should incorporate long-distance running experiments to more convincingly validate the accuracy of gait parameters to ensure their applicability in real-life running gait analysis (Straczkiewicz et al., 2023). Second, the current validation focused on a specific cohort of healthy young males. It should be noted that the validity of the algorithmic parameters within the MFD-GED framework is currently established strictly within the context of the gait characteristics of this specific cohort. Since biomechanical variables (e.g., impact loading and limb swing velocity) vary significantly with gender and age, the direct application of the current framework to other populations might affect detection performance. Therefore, future deployment in broader cohorts (including females and older adults) necessitates verifying the suitability of these parameters, potentially requiring population-specific tuning to ensure optimal accuracy. Additionally, future studies should assess the algorithm’s robustness in individuals with gait pathologies (e.g., asymmetry or deformity) to verify the generalizability of the parametric event detection strategy. The next applications involve adapting this algorithm for real-time running gait analysis in sports settings. Furthermore, a significant methodological limitation was the absence of hardware synchronization (e.g., TTL triggering) between the IMU sensors and the laboratory reference system. Consequently, a direct, point-by-point validation of the absolute timestamps for individual IC and TC events could not be performed. However, it is important to note that this limitation does not compromise the validity of the derived gait parameters, as these metrics rely on relative time intervals rather than absolute time registration. Future improvements to this approach could include better balancing between angular velocity and acceleration data for more precise event detection and gait parameter estimation. Ultimately, we aim to develop a real-time foot-mounted IMU gait monitoring and analysis system applicable to real-world scenarios, contributing to advancements in running gait analysis technology.
5 Conclusion
The present study introduces a novel method for accurately estimating gait spatiotemporal and kinetic parameters in running gait analysis via a single foot-mounted IMU. A fusion-based and parametric approach, MFD-GED, was used to increase event detection accuracy. The method underwent comprehensive validation, including Pearson’s r, ICCs, and Bland–Altman analysis, providing a more systematic evaluation than commonly seen in previous IMU-based method development. The findings from the 10-m run test confirm the high validity of the MFD-GED method, demonstrating its effectiveness for detailed running gait characterization within controlled environments. Compared with those of previous methods, the accuracy of the estimation is improved by selecting the optimal gait segmentation and event detection algorithms. Although the estimation accuracy for FT and peak vGRF was slightly lower than for other metrics, the overall performance indicates that the MFD-GED method is sufficiently robust for biomechanical analysis in research applications. Notably, while currently validated in an offline mode for healthy young males, our next steps involve extending this framework to more diverse populations and running conditions. Ultimately, our aim is to develop a portable gait monitoring and analysis system applicable in real-world scenarios, contributing to advancements in running gait analysis technology.
Data availability statement
The original contributions presented in the study are included in the article/supplementary material, further inquiries can be directed to the corresponding author.
Ethics statement
The studies involving humans were approved by the Sports Science Experimental Ethics Committee of Beijing Sport University. The studies were conducted in accordance with the local legislation and institutional requirements. The participants provided their written informed consent to participate in this study.
Author contributions
YW: Data curation, Formal Analysis, Methodology, Conceptualization, Writing – review and editing, Writing – original draft. HZ: Data curation, Writing – original draft. SW: Writing – original draft, Data curation. CL: Data curation, Writing – original draft. QX: Data curation, Writing – original draft. LS: Formal Analysis, Writing – original draft, Funding acquisition, Supervision, Writing – review and editing, Conceptualization, Methodology. YS: Writing – review and editing, Supervision, Conceptualization, Funding acquisition, Methodology, Formal Analysis, Writing – original draft.
Funding
The author(s) declared that financial support was received for this work and/or its publication. This research was funded by the National Natural Science Foundation of China, grant number 72071018, the Key Laboratory for Performance Training and Recovery of General Administration of Sport, grant number 2024TNJNO11, and the Engineering Research Center of Strength and Conditioning Training Key Core Technology Integrated System and Equipment, Ministry of Education, grant number 2024GCZX001.
Acknowledgements
We express our gratitude to the participants from Beijing Sport University for their valuable contributions and willingness to participate in the data collection process.
Conflict of interest
The author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Generative AI statement
The author(s) declared that generative AI was not used in the creation of this manuscript.
Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.
Publisher’s note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
References
Adams, D., Pozzi, F., Carroll, A., Rombach, A., and Zeni, J. R. J. (2016). Validity and reliability of a commercial fitness watch for measuring running dynamics. Journal Orthopaedic and Sports Physical Therapy 46, 471–476. doi:10.2519/jospt.2016.6391
Allseits, E., Lučarević, J., Gailey, R., Agrawal, V., Gaunaurd, I., and Bennett, C. (2017). The development and concurrent validity of a real-time algorithm for temporal gait analysis using inertial measurement units. J. Biomechanics 55, 27–33. doi:10.1016/j.jbiomech.2017.02.016
Benson, L. C., Clermont, C. A., Watari, R., Exley, T., and Ferber, R. (2019). Automated accelerometer-based gait event detection during multiple running conditions. Sensors 19, 1483. doi:10.3390/s19071483
Bergamini, E., Picerno, P., Pillet, H., Natta, F., Thoreux, P., and Camomilla, V. (2012). Estimation of temporal parameters during sprint running using a trunk-mounted inertial measurement unit. J. Biomechanics 45, 1123–1126. doi:10.1016/j.jbiomech.2011.12.020
Bland, J. M., and Altman, D. (1986). Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 327, 307–310. doi:10.1016/s0140-6736(86)90837-8
Blickhan, R. (1989). The spring-mass model for running and hopping. J. Biomechanics 22, 1217–1227. doi:10.1016/0021-9290(89)90224-8
Castro-Piñero, J., Aragón-Aragón, P., Cruz-León, C., Jiménez-Iglesias, J., Camiletti-Moirón, D., Izquierdo-Gómez, R., et al. (2023). Time measurement validity and reliability of the 4× 10-m shuttle run test in adult population: the ADULT-FIT project. J. Sci. Med. Sport 26, 553–560. doi:10.1016/j.jsams.2023.08.176
Chapman, R. M., Moschetti, W. E., and VAN Citters, D. W. (2019). Stance and swing phase knee flexion recover at different rates following total knee arthroplasty: an inertial measurement unit study. J. Biomechanics 84, 129–137. doi:10.1016/j.jbiomech.2018.12.027
Chen, K. Y., Janz, K. F., Zhu, W., and Brychta, R. J. (2012). Re-defining the roles of sensors in objective physical activity monitoring. Med. Science Sports Exercise 44, S13–S23. doi:10.1249/MSS.0b013e3182399bc8
Cheng, D. K., Nelson, M., Brooks, D., and Salbach, N. M. (2020). Validation of stroke-specific protocols for the 10-meter walk test and 6-minute walk test conducted using 15-meter and 30-meter walkways. Top. Stroke Rehabilitation 27, 251–261. doi:10.1080/10749357.2019.1691815
Chew, D.-K., Ngoh, K. J.-H., Gouwanda, D., and Gopalai, A. A. (2018). Estimating running spatial and temporal parameters using an inertial sensor. Sports Eng. 21, 115–122. doi:10.1007/s12283-017-0255-9
Di Michele, R., and Merni, F. (2014). The concurrent effects of strike pattern and ground-contact time on running economy. J. Science Medicine Sport 17, 414–418. doi:10.1016/j.jsams.2013.05.012
Dugan, S. A., and Bhat, K. P. (2005). Biomechanics and analysis of running gait. Phys. Med. Rehabilitation Clin. 16, 603–621. doi:10.1016/j.pmr.2005.02.007
Fadillioglu, C., Stetter, B. J., Ringhof, S., Krafft, F. C., Sell, S., and Stein, T. (2020). Automated gait event detection for a variety of locomotion tasks using a novel gyroscope-based algorithm. Gait and Posture 81, 102–108. doi:10.1016/j.gaitpost.2020.06.019
Falbriard, M., Meyer, F., Mariani, B., Millet, G. P., and Aminian, K. (2018). Accurate estimation of running temporal parameters using foot-worn inertial sensors. Front. Physiology 9, 610. doi:10.3389/fphys.2018.00610
Foxlin, E. (2005). Pedestrian tracking with shoe-mounted inertial sensors. IEEE Comput. Graphics Applications 25, 38–46. doi:10.1109/mcg.2005.140
García-Pinillos, F., Latorre-Román, P. Á., Soto-Hermoso, V. M., Párraga-Montilla, J. A., Pantoja-Vallejo, A., Ramírez-Campillo, R., et al. (2019). Agreement between the spatiotemporal gait parameters from two different wearable devices and high-speed video analysis. PLoS One 14, e0222872. doi:10.1371/journal.pone.0222872
Garcia-Pinillos, F., Chicano-Gutierrez, J. M., Ruiz-Malagon, E. J., and Roche-Seruendo, L. E. (2020). Influence of RunScribe™ placement on the accuracy of spatiotemporal gait characteristics during running. Proc. Institution Mech. Eng. Part P J. Sports Eng. Technol. 234, 11–18. doi:10.1177/1754337119876513
García-Pinillos, F., Roche-Seruendo, L. E., Marcén-Cinca, N., Marco-Contreras, L. A., and Latorre-Román, P. A. (2021). Absolute reliability and concurrent validity of the stryd system for the assessment of running stride kinematics at different velocities. J. Strength and Cond. Res. 35, 78–84. doi:10.1519/jsc.0000000000002595
Hanley, B., Bissas, A., Merlino, S., and Burns, G. T. (2023). Changes in running biomechanics during the 2017 IAAF world championships men's 1500 m final. Scand. J. Med. and Sci. Sports 33, 931–942. doi:10.1111/sms.14331
He, Y., Chen, Y., Tang, L., Chen, J., Tang, J., Yang, X., et al. (2024). Accuracy validation of a wearable IMU-based gait analysis in healthy female. BMC Sports Sci. Med. Rehabilitation 16, 2. doi:10.1186/s13102-023-00792-3
Hoogkamer, W., Kipp, S., Frank, J. H., Farina, E. M., Luo, G., and Kram, R. (2018). A comparison of the energetic cost of running in marathon racing shoes. Sports Med. 48, 1009–1019. doi:10.1007/s40279-017-0811-2
Hutabarat, Y., Owaki, D., and Hayashibe, M. (2020). Quantitative gait assessment with feature-rich diversity using two IMU sensors. IEEE Trans. Med. Robotics Bionics 2, 639–648. doi:10.1109/tmrb.2020.3021132
Kim, K., Kim, J. S., and Kim, Y. J. (2015). “Application of nonlinear complementary filters to human motion analysis,” in 2015 17th International Conference on E-health Networking, Application and services (HealthCom). IEEE, 594–595.
Kim, S., Son, M., Shin, S., Kim, T., and Choi, S. (2025). Analysis of gait characteristics to evaluate injury risk after high-intensity exercise, focusing on canoe athletes: a preliminary study. Front. Sports Active Living 7, 1652610. doi:10.3389/fspor.2025.1652610
Koo, T. K., and Li, M. Y. (2016). A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J. Chiropr. Med. 15, 155–163. doi:10.1016/j.jcm.2016.02.012
Lee, J. K., and Park, E. J. (2011). Quasi real-time gait event detection using shank-attached gyroscopes. Med. and Biological Engineering and Computing 49, 707–712. doi:10.1007/s11517-011-0736-0
Li, Y., and Wang, J. J. (2014). A pedestrian navigation system based on low cost IMU. J. Navigation 67, 929–949. doi:10.1017/S0373463314000344
Lin, S., Evans, K., Hartley, D., Morrison, S., Mcdonald, S., Veidt, M., et al. (2025). A review of gait analysis using gyroscopes and inertial measurement units. Sensors 25, 3481. doi:10.3390/s25113481
Lu, Y., Zhu, J., Chen, W., and Ma, X. (2023). An imu-based real-time gait detection method for intelligent control of knee assistive devices. IEEE Trans. Instrum. Meas. 72, 1–9. doi:10.1109/tim.2023.3329222
Luo, B., Wang, Z., Wang, D., Chen, L., and Ma, X. (2024). Algorithm for gait parameters estimation based on heel-mounted inertial sensors. IEEE Sensors J. 24, 24723–24736. doi:10.1109/jsen.2024.3410402
Maiwald, C., Sterzing, T., Mayer, T., and Milani, T. (2009). Detecting foot-to-ground contact from kinematic data in running. Footwear Sci. 1, 111–118. doi:10.1080/19424280903133938
Mancini, M., and Horak, F. B. (2016). Potential of APDM mobility lab for the monitoring of the progression of Parkinson’s disease. Expert Review Medical Devices 13, 455–462. doi:10.1586/17434440.2016.1153421
Mariani, B., Rouhani, H., Crevoisier, X., and Aminian, K. (2013). Quantitative estimation of foot-flat and stance phase of gait using foot-worn inertial sensors. Gait and Posture 37, 229–234. doi:10.1016/j.gaitpost.2012.07.012
Mason, R., Barry, G., Robinson, H., O’Callaghan, B., Lennon, O., Godfrey, A., et al. (2023a). Validity and reliability of the DANU sports system for walking and running gait assessment. Physiol. Meas. 44, 115001. doi:10.1088/1361-6579/ad04b4
Mason, R., Pearson, L. T., Barry, G., Young, F., Lennon, O., Godfrey, A., et al. (2023b). Wearables for running gait analysis: a systematic review. Sports Med. 53, 241–268. doi:10.1007/s40279-022-01760-6
Mcmahon, T. A., and Cheng, G. C. (1990). The mechanics of running: how does stiffness couple with speed? J. Biomechanics 23, 65–78. doi:10.1016/0021-9290(90)90042-2
Miller, E. J., Sheehan, R. C., and Kaufman, K. R. (2022). IMU filter settings for high intensity activities. Gait and Posture 91, 26–29. doi:10.1016/j.gaitpost.2021.10.006
Mitschke, C., Hes, T., and Milani, T. L. (2017). Which method detects foot strike in rearfoot and forefoot runners accurately when using an inertial measurement unit? Appl. Sci. 7, 959. doi:10.3390/app7090959
Mo, S., and Chow, D. H. (2018). Stride-to-stride variability and complexity between novice and experienced runners during a prolonged run at anaerobic threshold speed. Gait and Posture 64, 7–11. doi:10.1016/j.gaitpost.2018.05.021
Morin, J.-B., Dalleau, G., Kyröläinen, H., Jeannin, T., and Belli, A. (2005). A simple method for measuring stiffness during running. J. Applied Biomechanics 21, 167–180. doi:10.1123/jab.21.2.167
Morris, R., Stuart, S., Mcbarron, G., Fino, P. C., Mancini, M., and Curtze, C. (2019). Validity of Mobility Lab (version 2) for gait assessment in young adults, older adults and Parkinson’s disease. Physiol. Measurement 40, 095003. doi:10.1088/1361-6579/ab4023
Muro-De-La-Herran, A., Garcia-Zapirain, B., and Mendez-Zorrilla, A. (2014). Gait analysis methods: an overview of wearable and non-wearable systems, highlighting clinical applications. Sensors 14, 3362–3394. doi:10.3390/s140203362
Napier, C., Cochrane, C. K., Taunton, J. E., and Hunt, M. A. (2015). Gait modifications to change lower extremity gait biomechanics in runners: a systematic review. Br. J. Sports Med. 49, 1382–1388. doi:10.1136/bjsports-2014-094393
Nijs, A., Roerdink, M., and Beek, P. J. (2022). Running-style modulation: effects of stance-time and flight-time instructions on duty factor and cadence. Gait and Posture 98, 283–288. doi:10.1016/j.gaitpost.2022.10.002
Norris, M., Anderson, R., and Kenny, I. C. (2014). Method analysis of accelerometers and gyroscopes in running gait: a systematic review. Proc. Institution Mech. Eng. Part P J. Sports Eng. Technol. 228, 3–15. doi:10.1177/1754337113502472
Patoz, A., Lussiana, T., Breine, B., Piguet, E., Gyuriga, J., Gindre, C., et al. (2022). Using statistical parametric mapping to assess the association of duty factor and step frequency on running kinetic. Front. Physiology 13, 1044363. doi:10.3389/fphys.2022.1044363
Prasanth, H., Caban, M., Keller, U., Courtine, G., Ijspeert, A., Vallery, H., et al. (2021). Wearable sensor-based real-time gait detection: a systematic review. Sensors 21, 2727. doi:10.3390/s21082727
Prigent, G., Aminian, K., Cereatti, A., Salis, F., Bonci, T., Scott, K., et al. (2023). A robust walking detection algorithm using a single foot-worn inertial sensor: validation in real-life settings. Med. and Biol. Eng. and Comput. 61, 2341–2352. doi:10.1007/s11517-023-02826-x
Reenalda, J., Maartens, E., Buurke, J. H., and Gruber, A. H. (2019). Kinematics and shock attenuation during a prolonged run on the athletic track as measured with inertial magnetic measurement units. Gait and Posture 68, 155–160. doi:10.1016/j.gaitpost.2018.11.020
Ridge, S. T., Trotter, T., Sponbeck, J. K., Johnson, A. W., Hunter, I., and Bruening, D. A. (2025). Variability among individual Male runners influences cumulative loading more than foot strike type. Sports Health, 19417381251333415. doi:10.1177/19417381251333415
Ruiz-Ruiz, L., García-Domínguez, J. J., and Jiménez, A. R. (2024). A novel foot-forward segmentation Algorithm for improving IMU-based gait analysis. IEEE Trans. Instrum. Meas. 73, 1–13. doi:10.1109/tim.2024.3449951
Santos, M., Zdravevski, E., Albuquerque, C., Coelho, P. J., and Pires, I. M. (2025). Ten Meter Walk Test for motor function assessment with technological devices based on lower members’ movements: a systematic review. Comput. Biol. Med. 187, 109734. doi:10.1016/j.compbiomed.2025.109734
Sardroodian, M., and Hosseinzadeh, M. (2020). Gender differences in the spatial–temporal variability between walking and running. Sport Sci. Health 16, 123–127. doi:10.1007/s11332-019-00582-w
Scivoletto, G., Tamburella, F., Laurenza, L., Foti, C., Ditunno, J., and Molinari, M. (2011). Validity and reliability of the 10-m walk test and the 6-min walk test in spinal cord injury patients. Spinal Cord 49, 736–740. doi:10.1038/sc.2010.180
Sethi, D., Bharti, S., and Prakash, C. (2022). A comprehensive survey on gait analysis: history, parameters, approaches, pose estimation, and future work. Artif. Intell. Med. 129, 102314. doi:10.1016/j.artmed.2022.102314
Straczkiewicz, M., Huang, E. J., and Onnela, J.-P. (2023). A “one-size-fits-most” walking recognition method for smartphones, smartwatches, and wearable accelerometers. NPJ Digit. Med. 6, 29. doi:10.1038/s41746-022-00745-z
Stuart, S., Powell, D., Marshall, S. J., Clark, C. C., Martini, D. N., Johnston, W., et al. (2021). “Sports medicine: bespoke player management,” in Digital health. Elsevier.
Tan, T., Chiasson, D. P., Hu, H., and Shull, P. B. (2019). Influence of IMU position and orientation placement errors on ground reaction force estimation. J. Biomechanics 97, 109416. doi:10.1016/j.jbiomech.2019.109416
Tao, W., Liu, T., Zheng, R., and Feng, H. (2012). Gait analysis using wearable sensors. Sensors 12, 2255–2283. doi:10.3390/s120202255
Trojaniello, D., Cereatti, A., and Della Croce, U. (2014). Accuracy, sensitivity and robustness of five different methods for the estimation of gait temporal parameters using a single inertial sensor mounted on the lower trunk. Gait and Posture 40, 487–492. doi:10.1016/j.gaitpost.2014.07.007
Uno, Y., Ogasawara, I., Konda, S., Yoshida, N., Otsuka, N., Kikukawa, Y., et al. (2022). Validity of spatio-temporal gait parameters in healthy young adults using a motion-sensor-based gait analysis system (ORPHE ANALYTICS) during walking and running. Sensors 23, 331. doi:10.3390/s23010331
Wang, L., Hu, W., and Tan, T. (2003). Recent developments in human motion analysis. Pattern Recognition 36, 585–601. doi:10.1016/s0031-3203(02)00100-0
Wang, X., Kyrarini, M., Ristić-Durrant, D., Spranger, M., and Gräser, A. (2016). “Monitoring of gait performance using dynamic time warping on IMU-sensor data,” in 2016 IEEE international symposium on medical measurements and applications (MeMeA), 2016. IEEE, 1–6.
Wang, L., Sun, Y., Li, Q., Liu, T., and Yi, J. (2020). IMU-based gait normalcy index calculation for clinical evaluation of impaired gait. IEEE J. Biomed. Health Inf. 25, 3–12. doi:10.1109/JBHI.2020.2982978
Watanabe, T., Kondo, S., Kakinoki, K., Fukusaki, C., and Hatta, H. (2023). Stride-to-stride variability and fluctuations at intensities around lactate threshold in distance runners. Heliyon 9, e17437. doi:10.1016/j.heliyon.2023.e17437
Yamamoto, M., Shimatani, K., Ishige, Y., and Takemura, H. (2022). Verification of gait analysis method fusing camera-based pose estimation and an IMU sensor in various gait conditions. Sci. Reports 12, 17719. doi:10.1038/s41598-022-22246-5
Yang, Y., Wang, L., Su, S., Watsford, M., Wood, L. M., and Duffield, R. (2022). Inertial sensor estimation of initial and terminal contact during In-field running. Sensors 22, 4812. doi:10.3390/s22134812
Yoon, D. H., Kim, J.-H., Lee, K., Cho, J.-S., Jang, S.-H., and Lee, S.-U. (2024). Inertial measurement unit sensor-based gait analysis in adults and older adults: a cross-sectional study. Gait and Posture 107, 212–217. doi:10.1016/j.gaitpost.2023.10.006
Young, F., Mason, R., Wall, C., Morris, R., Stuart, S., and Godfrey, A. (2022). Examination of a foot mounted IMU-based methodology for a running gait assessment. Front. Sports Act. Living 4, 956889. doi:10.3389/fspor.2022.956889
Zhang, R., Yang, H., Höflinger, F., and Reindl, L. M. (2017). Adaptive zero velocity update based on velocity classification for pedestrian tracking. IEEE Sensors Journal 17, 2137–2145. doi:10.1109/jsen.2017.2665678
Zhang, H., Guo, Y., and Zanotto, D. (2019). Accurate ambulatory gait analysis in walking and running using machine learning models. IEEE Trans. Neural Syst. Rehabilitation Eng. 28, 191–202. doi:10.1109/TNSRE.2019.2958679
Zhang, G., Chen, T. L.-W., Liu, Y., Wei, L., Chen, S. F., Wang, Y., et al. (2025). Identifying fatigue-related gait patterns using multiple inertial measurement units and statistical parametric mapping: a continuous analysis of an outdoor full marathon in Male recreational runners. Sports Medicine-Open 11, 119. doi:10.1186/s40798-025-00915-9
Zhao, Y., Brahms, M., Gerhard, D., and Barden, J. (2016). “Stance phase detection for walking and running using an IMU periodicity-based approach,” in Proceedings of the 10th international symposium on computer science in sports (ISCSS). Springer, 225–232.
Keywords: gait event detection, inertial measurement units, running gait analysis, validation, zero-velocity update
Citation: Wu Y, Zhang H, Wang S, Lu C, Xing Q, Sun L and Shen Y (2026) Improved running gait parameter estimation from single foot-mounted IMU data based on refined event detection. Front. Bioeng. Biotechnol. 13:1714473. doi: 10.3389/fbioe.2025.1714473
Received: 27 September 2025; Accepted: 31 December 2025;
Published: 13 January 2026.
Edited by:
Sean S. Kohles, Kohles Bioengineering Corp, United StatesReviewed by:
Navrag B. Singh, ETH Zürich, SwitzerlandJae Hyeon Park, Hanyang University, Republic of Korea
Anna Ghidotti, University of Bergamo, Italy
Copyright © 2026 Wu, Zhang, Wang, Lu, Xing, Sun and Shen. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Lixin Sun, c3VubGl4aW5AYnN1LmVkdS5jbg==; Yanfei Shen, c3lmQGJzdS5lZHUuY24=
Haoran Zhang2