Real-World Efficacy of MiniMedTM780G Recommended Settings (Glycemic Target 100 mg/dL, Active Insulin Time 2 hours) in Youth and Young Adults with Type 1 Diabetes
Provisionally accepted- 1Universita degli Studi di Genova, Genoa, Italy
- 2IRCCS Istituto Giannina Gaslini, Genova, Italy
Select one of your emails
You have multiple emails registered with Frontiers:
Notify me on publication
Please enter your email address:
If you already have an account, please login
You don't have a Frontiers account ? You can register here
Background and aims: Despite growing evidence supporting the efficacy and safety of the MiniMed™ 780G recommended settings (Glucose Target 100 mg/dL and Active Insulin Time 2 hours), their adoption in routine practice remains limited, mainly due to concerns about hypoglycemia. This study aimed to evaluate the impact of switching to these settings in pediatric and young patients with type 1 diabetes (T1D). Methods: We conducted a retrospective longitudinal analysis in children and young adults using MiniMed™780G system at our center. Patients who switched from their initial settings to a glucose target of 100 mg/dL and an active insulin time of 2 hours for clinical indications were included. Data were retrospectively collected 3 months after switch. Glycemic metrics were compared over the 14 days before the switch (T0) and at 1 month (T1), and 3 months (T3). Results: Ninety-one patients with a mean age of 17.89y were included, 81.3% of whom already had a glucose target of 100 mg/dL at baseline. Therefore, in most cases the primary change was reducing AIT from 3 to 2 hours. After switching to the recommended settings, Time in Range (TIR) significantly increased (p<0.001) at T1 (71.9% vs 74.8%) and T3 (71.9% vs 75.0%; p<0.001). Time in target range (TITR) similarly improved from 47.2% at T0 to 51.4% at T1 and 50.9% at T3 (p<0.001) without any significant increase in time below range (TBR). The proportion of patients meeting all ADA-recommended glycemic targets rose from 29.5% at baseline to 40% at T3. Following the switch, the contribution of automatic correction boluses to the total insulin dose increased, while overall daily insulin requirements remained stable. Conclusions: Switching to the recommended MiniMed™780G settings, driven primarily by AIT reduction in most patients, was safe and effective, improving glycemic control without increasing hypoglycemia.Switching to the recommended MiniMed™780G settings, particularly shortening the AIT to 2 hours was safe and effective, improving glycemic control without increasing hypoglycemia. These findings support broader use of these settings in pediatric and young adult patient with type 1 diabetes.
Keywords: AHCL (Advanced Hybrid Closed Loop), AID (Automated Insulin Delivery), Minimed 780G®, Type 1 diabetes (T1D), CGM (continuous glucose monitoring), TIR (time in range), Active Insulin Time (AIT), Glucose Target (GT)
Received: 21 Jul 2025; Accepted: 26 Aug 2025.
Copyright: © 2025 Bassi, Spacco, Pezzotta, Jorgi, Siri, Pintabona, Calevo, Minuto and Maghnie. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
* Correspondence: Nicola Minuto, IRCCS Istituto Giannina Gaslini, Genova, Italy
Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.