Comparative Evaluation of Point-of-Care Blood Gas Analysis in Rabbit Disease Models
Provisionally accepted- 1Institute of Animal Medicine, College of Veterinary Medicine, Gyeongsang National University, Jinju, Republic of Korea
- 2Hanaro Veterinary Clinic, Daejeon, Republic of Korea
- 3Department of Information and Statistics, Gyeongsang National University, Jinju, Republic of Korea
Select one of your emails
You have multiple emails registered with Frontiers:
Notify me on publication
Please enter your email address:
If you already have an account, please login
You don't have a Frontiers account ? You can register here
Objective: This study aims to evaluate the blood gas results in various rabbit disease models and to establish the reference interval of venous and arterial blood gas parameters for clinically healthy and diseased rabbits. The primary purpose of this study is to evaluate various disease effects on acid-base and electrolyte disturbance and to examine the clinical value of blood gas analysis in rabbits. Methods: Two hundred rabbits with various breeds were included in the study. Rabbits were divided into dental, gastrointestinal, musculoskeletal, and urologic disease model groups and one clinically healthy group. Venous and arterial blood gas analyses were performed with a point-of-care blood gas analyzer, i-Smart 300 VET Blood Gas Analyzer (i-SENSE, Korea). The reference intervals for the blood gas results were established. Reference intervals for each diseased group were compared with a clinically healthy control group to analyze the disease's effect on blood gas values. Results: Several acid-base and electrolyte derangements were confirmed. The dental disease model had lower pH, PCO2, and HCO3 than the control group (p-values < 0.001 by t-tests for pH and HCO3, and p-value < 0.01 for PCO2). The gastrointestinal disease model demonstrated hyponatremia and hypocalcemia compared to the control group, with the p-values < 0.01 by t-tests. The musculoskeletal disease model had lower Hct and HGB than the control (p-values < 0.01 by t-tests). The urologic disease group did not have a statistically significant difference in the reference interval of blood gas results. The results indicated that various disease models in rabbits alter blood gas values. Diseases in body systems correlated with acid-base and electrolyte regulation are more likely to induce blood gas derangements. However, blood gas evaluation in various rabbit diseases is limited. Further studies with more cases in equivalent distribution and other disease models are needed. Clinical Relevance: This study is the first to present the reference interval for venous and arterial blood gas results in various disease models of rabbits. Also, this study presented the clinical value of point-of-care blood gas analysis in rabbit diseases. Blood gas analysis has potential diagnostic and prognostic value on various rabbit diseases.
Keywords: Blood Gas Analysis, Reference interval, rabbit, disease models, acid-base, electrolyte
Received: 02 May 2025; Accepted: 09 Jun 2025.
Copyright: © 2025 Park, Cho, Huy, Kim, Kim and Park. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
* Correspondence: Beomjin Park, Department of Information and Statistics, Gyeongsang National University, Jinju, Republic of Korea
Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.