- 1Department of Laboratory Medicine, Universitair Ziekenhuis Gent, Ghent, Belgium
- 2Department of Laboratory Medicine, Algemeen Ziekenhuis Sint-Jan Brugge AV, Bruges, Belgium
- 3Department of Microbiology, Immunology and Transplantation, Clinical and Diagnostic Immunology, Katholieke Universiteit Leuven, Leuven, Belgium
- 4Department of Neurology, Universitair Ziekenhuis Gent, Ghent, Belgium
- 5Department of Laboratory Medicine, Algemeen Ziekenhuis Maria Middelares, Ghent, Belgium
- 6Department of Neurology, Algemeen Ziekenhuis Sint-Jan Brugge AV, Bruges, Belgium
- 7Faculty of Medicine and Health Sciences, Universiteit Gent, Ghent, Belgium
- 8Basic Biomedical Sciences, Vrije Universiteit Brussel, Brussels, Belgium
Introduction
The kappa free light chain (κFLC) index, defined as the quotient of the κFLC ratio to albumin ratio in cerebrospinal fluid (CSF) and serum, was incorporated in the 2024 revisions of the McDonald criteria for multiple sclerosis (MS) diagnosis (1, 2). Recent evidence indicates that the κFLC index tested with validated assays quantifies intrathecal immunoglobulin synthesis with similar diagnostic accuracy for MS as CSF-specific oligoclonal bands (OCBs) (3–5). The 2017 revisions of the McDonald criteria facilitated diagnosis with the inclusion of CSF oligoclonal bands as a substitute for dissemination in time (DIT), with the 2024 revisions adding the κFLC index as interchangeable with oligoclonal bands. However, absolute κFLC values differ between methods, resulting in a method-specific cut-off for the κFLC index (3–8).
The optimal κFLC index cut-off is a matter of debate (1). A laboratory cut-off depends on many variables, such as the patient groups that need to be discriminated, the required sensitivity and specificity, the laboratory reagents, and, to a lesser extent, the analyzer. Clinicians prefer a clear-cut, binary classification of laboratory test results. However, the interpretation often cannot be considered black or white but demands expertise. It is the responsibility of laboratory specialists to support clinicians in making the final interpretation. In autoimmune serology, there is growing recognition of the value of reporting likelihood ratios (LRs) for specific diseases alongside the manufacturer’s cut-off values (9, 10). The LR is defined as the prevalence of patients with a particular test result divided by the prevalence of controls with the same test result. For instance, a test result with a LR of 10 indicates that the test result is 10 times more likely in patients than in controls. Using the LR, the probability of a specific disease can be calculated when the pre-test probability, based on clinical signs and other investigations, is defined. In light of the ongoing debate about the optimal cut-off value of the κFLC index for diagnosing MS, we propose the use of the κFLC index LR in addition to a fixed numerical threshold. This approach allows for a more clinically meaningful interpretation of test results. Moreover, the κFLC index LR enables the comparison of laboratory results obtained using different reagents or analyzers, allowing different numerical values to be assigned the same clinical significance. In clinical practice, the LR concept is the most effective when specific result intervals, rather than individual test values, are associated with a defined LR.
In this study, we demonstrate that using interval-specific LRs allows for the harmonization of method-dependent cut-offs and provides additional clinical value in the diagnosis of MS by enabling the calculation of post-test probabilities (10).
Methods and results
The LR concept was applied to a previously published patient cohort from two centers (4) using reagents from The Binding Site (Freelite®) and Siemens (N Latex®) in parallel on the same samples (Figures 1A, B). Paired serum and CSF samples from patients with neurological diseases were collected from the AZ Sint-Jan Bruges and UZ Ghent University hospital biobanks. Seventy-four patients were diagnosed with MS using the revised 2017 McDonald criteria, 49 patients suffered from other inflammatory/infectious neurological diseases of the central and peripheral neurological system, and 98 patients suffered from non-inflammatory neurological diseases. In addition, 30 symptomatic controls were included without evidence of organic central or peripheral nervous system disease. κFLC and albumin were measured on Optilite, using the Freelite® Mx κ (kappa) Free assay and Low-Level Albumin assay from The Binding Site (The Binding Site, Birmingham, UK) versus the N Latex® reagent and the N Albumin antiserum anti-human albumin kit on BN II (Siemens Healthineers GmbH, Marburg, Germany). Diagnostic performance characteristics (specificity and LR) were calculated to discriminate MS patients (n = 74) from disease controls (n = 177). Next, test result interval-specific LRs were calculated based on predefined specificity levels <90%, 90%–95%, 95%–99%, and >99%. All analyses were performed using MedCalc Statistical Software version 17.6 (MedCalc Software bvba, Ostend, Belgium) and RStudio version 2024.
Figure 1. (A, B) Boxplots of κFLC index results measured using Freelite® (A) and N Latex® (B) in MS and non-MS patients, including OCB test results. (C, D) Prevalence (likelihood) of MS and non-MS according to κFLC index test result intervals, which are based on <90%, 90%–95%, 95%–99%, and >99% specificity levels. The corresponding likelihood ratios with 95% confidence intervals to the test result intervals are shown in the second y-axis. (E, F) Post-test probability for MS as a function of pre-test probability for different test result intervals (depicted as corresponding likelihood ratios including 95% confidence intervals). OCB, oligoclonal bands; MS, multiple sclerosis; NIND, non-inflammatory neurological disorder; OIND, other inflammatory neurological disorder; SC, symptomatic controls; SP, specificity; κFLC, kappa free light chain.
Although the nominal values for the κFLC index corresponding to the predefined specificity levels differ between the Freelite® and N Latex® assays, an increased probability of MS was observed in both methods with increasing κFLC index. When the κFLC index was within the 95%–99% specificity cut-off of either assay (11.91–54.18 for Freelite® and 6.84–34.73 for N Latex®), the LR for both assays was 9.9 (95% confidence interval, 4.5–21.6), indicating that this test result was ± 10× more likely to be found in patients with MS at diagnosis compared to patients without MS (Figures 1C, D). In contrast, patients were ± 10 times less likely to have MS when the κFLC index was below the 90% specificity cut-off of either assay (<7.39 for Freelite® and <4.63 for N Latex®) (Figures 1C, D). Of the patients with MS, 39% and 49% had a κFLC index >54.18 (Freelite®) and >34.73 (N Latex®), respectively. Ninety percent of the controls had a κFLC index <7.39 (Freelite®) and <6.8 (N Latex®). Table 1 shows two case examples of how LRs can be integrated into the laboratory report. These LRs can be automatically generated using the laboratory information system (LIS) based on the κFLC index result.
Table 1. Two case examples of communicating likelihood ratio values in a clinical laboratory report.
By combining the pre-test probability for MS, based on the clinical presentation and MRI criteria for dissemination in space (3), one can calculate the post-test probability for MS. As visualized in Figures 1E, F, if the pre-test probability is, for example, 40%, the post-test probability for MS is 87% when a κFLC ratio between 11.9 and 54.2 is obtained using the Freelite® assay (Figure 1E) and 87% when a κFLC ratio between 6.8 and 34.7 is obtained using the N Latex® assay (Figure 1F). One could also calculate these probabilities based on pre-test and post-test odds (10).
Discussion
Clinical laboratories should consider reporting interval-specific LRs alongside numerical cut-offs. This is especially important for immunological tests like the κFLC index, where results differ across platforms due to a lack of standardization. As demonstrated in this study, a high positive LR (ideally >10) is the most effective for confirming a diagnosis of MS, while a low negative LR (ideally <0.1) is the most useful for ruling it out. A LR > 10 does not mean 100% specificity for MS. Very high κFLC index ratios can also occur in non-MS patients, such as other inflammatory disorders of the nervous system, central nervous system infections, or monoclonal protein infiltration. The addition of test result interval-specific LRs next to a single cut-off on the laboratory report adds value since it is more informative than just a dichotomous interpretation based on sensitivity and specificity (i.e., a positive test result suggests the presence of disease, while a negative test result indicates the absence of disease (10)). As shown in Table 1, LRs can be automatically calculated using the LIS based on the κFLC result and included in the laboratory report next to the single cut-off. The examples in Table 1, which are actual samples used in this study, highlight that the quantitative values between Freelite® and N Latex® can differ, causing a different interpretation when a single cut-off is used. However, when LRs are added to the laboratory report, the interpretation of the two assays is harmonized, providing additional clinical information. It can be useful to add a non-technical explanation regarding the interpretation of the LRs (e.g., for a test result with a LR of 9.9, “the test result is 9.9 times more likely to be found in individuals with multiple sclerosis at diagnosis than in individuals without multiple sclerosis”).
Knowledge of pre-test probability is not required to calculate test result interval-specific LRs, but if available, it can be useful to compute the post-test probability of disease. If a clinician adds the pre-test probability information when requesting a κFLC index analysis, the LIS can automatically calculate and report the post-test probability for MS. The report could display the quantitative κFLC index, the single cut-off, the LR, and the post-test probability for MS, accompanied by a comprehensive conclusion. For example, if the pre-test probability of the second case in Table 1 is 50%, the automatically generated conclusion could state, “Estimated probability of multiple sclerosis is 91% given a pre-test probability of 50%”. The graphs provided in Figures 1E, F could accompany the report to visualize the interpretation of the LR. However, follow-up studies are needed for this to convert clinical data into pre-test probability percentages.
The calculation of test result interval-specific LRs requires a multicenter approach to ensure the inclusion of a sufficient number of patient and control samples. The composition of these groups can be tailored to the specific clinical question and the populations that need to be distinguished.
To conclude, interval-specific LRs informs clinicians about the likelihood of disease, independent of the laboratory platform or assay used, and offers a practical way to standardize test outcomes. This allows a more unambiguous interpretation of test results (10). An important role of the laboratory specialists is to educate clinicians about the added value of interval-specific LRs delivered by the laboratory.
Author contributions
MO: Conceptualization, Formal analysis, Investigation, Methodology, Visualization, Writing – original draft. LN: Conceptualization, Investigation, Methodology, Formal analysis, Visualization, Writing – original draft. CD: Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Project administration, Resources, Visualization, Writing – review & editing. PD: Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Project administration, Resources, Supervision, Visualization, Writing – review & editing. MC: Conceptualization, Data curation, Methodology, Writing – review & editing. LV: Data curation, Writing – review & editing. LVH: Data curation, Writing – review & editing. GL: Conceptualization, Data curation, Investigation, Methodology, Project administration, Resources, Supervision, Writing – review & editing. MV: Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Project administration, Resources, Supervision, Writing – review & editing.
Funding
The author(s) declare that no financial support was received for the research and/or publication of this article.
Acknowledgments
The authors would like to thank the patients who participated in this study and the clinicians who referred patients to AZ Sint-Jan Brugge and Universitair Ziekenhuis Gent. The Binding Site, part of Thermo Fisher Scientific, partially supported this study by donating Freelite® and albumin kits to AZ Sint-Jan Brugge. The authors maintained full editorial control of all content.
Conflict of interest
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Correction note
This article has been corrected with minor changes. These changes do not impact the scientific content of the article.
Generative AI statement
The author(s) declare that no Generative AI was used in the creation of this manuscript.
Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.
Publisher’s note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
Abbreviations
κFLC, kappa free light chain; CSF, cerebrospinal fluid; LR, likelihood ratio; MS, multiple sclerosis; LIS, laboratory information system.
References
1. Levraut M, Landes-Chateau C, Mondot L, Cohen M, and Lebrun-Frenay C. The kappa free light chains index and central vein sign: two new biomarkers for multiple sclerosis diagnosis. Neurol Ther. (2025) 14:711–31. doi: 10.1007/s40120-025-00737-7
2. Montalban X, Lebrun-Frénay C, Oh J, Arrambide G, Moccia M, Amato MP, et al. Diagnosis of multiple sclerosis: 2024 revisions of the McDonald criteria. Lancet Neurol. (2025) 24:850–65. doi: 10.1016/S1474-4422(25)00355-
3. Levraut M, Laurent-Chabalier S, Ayrignac X, Bigaut K, Rival M, Squalli S, et al. Kappa free light chain biomarkers are efficient for the diagnosis of multiple sclerosis: A large multicenter cohort study. Neurol Neuroimmunol Neuroinflamm. (2023) 10:e200049. doi: 10.1212/NXI.0000000000200049
4. Dekeyser C, De Kesel P, Cambron M, Vanopdenbosch L, Van Hijfte L, Vercammen M, et al. Inter-assay diagnostic accuracy of cerebrospinal fluid kappa free light chains for the diagnosis of multiple sclerosis. Front Immunol. (2024) 15:1385231. doi: 10.3389/fimmu.2024.1385231
5. Hegen H, Berek K, Cavalla P, Christiansen M, Emeršič A, Di Filippo M, et al. Diagnostic value of kappa free light chain index in patients with primary progressive multiple sclerosis – a multicentre study. Front Immunol. (2023) 14:1327947. doi: 10.3389/fimmu.2023.1327947
6. Hoedemakers RM, Pruijt JF, Hol S, Teunissen E, Martens H, Stam P, et al. Clinical comparison of new monoclonal antibody-based nephelometric assays for free light chain kappa and lambda to polyclonal antibody-based assays and immunofixation electrophoresis. Clin Chem Lab Med. (2011) 50:489–95. doi: 10.1515/cclm.2011.793
7. Graziani MS. Measurement of free light chains – pros and cons of current methods. Clin Chem Lab Med. (2016) 54:1015–20. doi: 10.1515/cclm-2015-1062
8. Kim H-S, Kim HS, Shin K-S, Song W, Kim HJ, Kim HS, et al. Clinical comparisons of two free light chain assays to immunofixation electrophoresis for detecting monoclonal gammopathy. BioMed Res Int. (2014) 2014:1–7. doi: 10.1155/2014/647238
9. Fierz W and Bossuyt X. Likelihood ratio approach and clinical interpretation of laboratory tests. Front Immunol. (2021) 12:655262. doi: 10.3389/fimmu.2021.655262
Keywords: Kappa free light chain index, likelihood ratios, multiple sclerosis, Kappa free light chains, Freelite-Optilite versus N Latex-BNII, harmonization
Citation: Oyaert M, Nevejan L, Dekeyser C, De Kesel P, Cambron M, Vanopdenbosch L, Van Hijfte L, Laureys G and Vercammen M (2025) Beyond the cut-off: harmonizing kappa free light chain index using likelihood ratios improves the clinical interpretation in the diagnosis of multiple sclerosis. Front. Immunol. 16:1672662. doi: 10.3389/fimmu.2025.1672662
Received: 24 July 2025; Accepted: 17 November 2025; Revised: 06 November 2025;
Published: 03 December 2025; Corrected: 10 December 2025.
Edited by:
Elisabeth Gulowsen Celius, Oslo University Hospital, NorwayReviewed by:
Alexander Dressel, Dept of Neurology Medical University Lausitz - Carl Thiem, GermanyMassimo Pieri, University of Rome Tor Vergata, Italy
Copyright © 2025 Oyaert, Nevejan, Dekeyser, De Kesel, Cambron, Vanopdenbosch, Van Hijfte, Laureys and Vercammen. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Martine Vercammen, TWFydGluZS5WZXJjYW1tZW5AYXpzaW50amFuLmJl; Matthijs Oyaert, bWF0dGhpanMub3lhZXJ0QHV6Z2VudC5iZQ==; Louis Nevejan, bG91aXMubmV2ZWphbkBhenNpbnRqYW4uYmU=
†These authors have contributed equally to this work
Pieter De Kesel5