CORRECTION article

Front. Neurorobot., 03 April 2018

Volume 12 - 2018 | https://doi.org/10.3389/fnbot.2018.00015

Corrigendum: The Reality of Myoelectric Prostheses: Understanding What Makes These Devices Difficult for Some Users to Control

  • Centre for Health Sciences Research, University of Salford, Salford, United Kingdom

In the original article, there was an error. The equation for the Magnitude Ratio presented in the Methods and Analysis was incorrect and should be written ln(VMNonDom/VMDom).

A correction has been made to Methods and Analysis, Everyday usage (Section 2.4), paragraph 1:

Current methods of quantifying everyday prosthesis use involve self-report (Roeschlein and Domholdt, 1989; Sherman, 1999; Gallagher and MacLachlan, 2000; Raichle et al., 2008), which is known to be prone to recall and bias errors (Metcalf et al., 2007; Brown and Werner, 2008). Accelerometer-based activity monitoring (Noorkõiv et al., 2014) provides an opportunity to observe actual prosthesis use outside of the clinical environment; however, to date no studies have been published on a cohort of upper limb prosthesis users. We have adapted a protocol developed for stroke patients (Bailey et al., 2015). This research involved participants wearing an activity monitor (Actigraph GT3X+) on each of their wrists while they went about their normal daily activities. The Actigraph monitors provide continuous logging of raw accelerometer data (sampled at 30 Hz). The data are downloaded using proprietary software, filtered, and down sampled to 1 Hz. The processed data are expressed as activity counts (0.001664 g/count) (Actigraph Corp., 2015), which are converted into vector magnitudes (sum of the counts along each axis ). For each second of data, Bailey et al. (2015) combined the vector magnitudes from each of the two wrist worn monitors (dominant and non-dominant arm) to inform on the magnitude of activity across both arms, expressed as the “bilateral magnitude” (VMDom + VMNonDom), and the contribution of each arm to the activity, expressed as the “magnitude ratio” [ln(VMNonDom/VMDom)].

The authors apologize for this error and state that this does not change the scientific conclusions of the article in any way.

Statements

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

References

  • 1

    Actigraph Corp. (2015). ActiGraph White Paper: What Is a Count?Pensacola, FL.

  • 2

    BaileyR. R.KlaesnerJ. W.LangC. E. (2015). Quantifying real-world upper-limb activity in nondisabled adults and adults with chronic stroke. Neurorehabil. Neural Repair29, 969978. 10.1177/1545968315583720

  • 3

    BrownB. B.WernerC. M. (2008). Using accelerometer feedback to identify walking destinations, activity overestimates, and stealth exercise in obese and nonobese individuals. J. Phys. Act. Health5, 882893.

  • 4

    GallagherP.MacLachlanM. (2000). Development and psychometric evaluation of the trinity amputation and prosthesis experience scales (TAPES). Rehabil. Psychol.45, 130154. 10.1037/0090-5550.45.2.130

  • 5

    MetcalfC.AdamsJ.BurridgeJ.YuleV.ChappellP. (2007). A review of clinical upper limb assessments within the framework of the WHO ICF. Musculoskeletal. Care5, 160173. 10.1002/msc.108

  • 6

    NoorkõivM.RodgersH.PriceC. I. (2014). Accelerometer measurement of upper extremity movement after stroke: a systematic review of clinical studies. J. Neuroeng. Rehabil.11, 111. 10.1186/1743-0003-11-144

  • 7

    RaichleK. A.HanleyM. A.MoltonI.KadelN. J.CampbellK.PhelpsE.et al. (2008). Prosthesis use in persons with lower- and upper-limb amputation. J. Rehabil. Res. Dev.45, 961972. 10.1682/JRRD.2007.09.0151

  • 8

    RoeschleinR. A.DomholdtE. (1989). Factors related to successful upper extremity prosthetic use. Prosthet. Orthot. Int.13, 1418.

  • 9

    ShermanR. A. (1999). Utilization of prostheses among US veterans with traumatic amputation: a pilot survey. J. Rehabil. Res. Dev.36, 100108.

Summary

Keywords

prosthesis, myoelectric, activity monitoring, control, upper limb, functionality assessment

Citation

Chadwell A, Kenney L, Thies S, Galpin A and Head J (2018) Corrigendum: The Reality of Myoelectric Prostheses: Understanding What Makes These Devices Difficult for Some Users to Control. Front. Neurorobot. 12:15. doi: 10.3389/fnbot.2018.00015

Received

18 February 2018

Accepted

19 March 2018

Published

03 April 2018

Volume

12 - 2018

Edited and reviewed by

Claudio Castellini, Robotik und Mechatronik Zentrum, Deutsches Zentrum für Luft- und Raumfahrt (DLR), Germany

Updates

Copyright

*Correspondence: Laurence Kenney

Disclaimer

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Outline

Cite article

Copy to clipboard


Export citation file


Share article

Article metrics