ORIGINAL RESEARCH article

Front. Soil Sci., 20 April 2023

Sec. Pedometrics

Volume 3 - 2023 | https://doi.org/10.3389/fsoil.2023.1137731

Temporal and operation-induced instability of apparent soil electrical conductivity measurements

  • 1. Department of Agriculture Technology, Faculty of Agriculture, Universiti Putra Malaysia, Serdang, Selangor, Malaysia

  • 2. Bioresource Engineering Department, Macdonald Campus of McGill University, Montreal, QC, Canada

Article metrics

View details

11

Citations

2,1k

Views

1,2k

Downloads

Abstract

Measuring apparent soil electrical conductivity (ECa), using galvanic contact resistivity (GCR) and electromagnetic induction (EMI) techniques, is frequently conducted to reveal spatial soil heterogeneity. Various studies have demonstrated the possibilities for significant changes in the measured quantities over time with relatively stable spatial structure representations. The objective of this study was to quantify the effects of temporal drift and operational noise for three popular ECa mapping instruments. They were placed in stationary positions approximately 8 m apart in an area with relatively low ECa. Temporal drift was assessed using a series of 4.5-h data logs recorded under different weather conditions (from extremely hot to near freezing temperatures). The two EMI instruments were also used to quantify the effect of minor changes in the height, pitch and roll of the sensor with respect to the ground. These operational noise tests were replicated over several days. Our results reveal the GCR measurements of ECa, along with perpendicular coplanar EMI measurements, have shown relatively strong stability over time. Each operational effect introduced measurement uncertainties comparable to the impact of a change in temperature and soil water content.

1 Introduction

Site-specific crop management has been implemented to increase profitability and reduce the negative environmental impact of modern farming. The application of proximal soil sensing facilitates the understanding of spatial variability of crop growing conditions. Thus, maps of apparent soil electrical conductivity (ECa) reveal soil heterogeneity as it relates to various physical characteristics affecting the ability of the soil to conduct an electrical charge. Soil ECa has been related to salinity (1–4), texture (5–7), soil water content (8–13) and cation exchange capacity (14).

The most popular methods for measuring soil ECa on-the-go are based on galvanic contact resistivity (GCR) and electromagnetic induction (EMI) techniques. Both involve at least one element causing an electrical current in soil and at least one element sensing resistance/conductance of soil media (15). For GCR, a set of contact electrodes (typically rolling discs) is used both to introduce the electrical current and to sense a change in potential at a fixed distance. These electrodes were configured using array configurations such as those of Schlumberger, Wenner, Dipole-dipole, and others (16, 17). Alternatively, EMI offers a non-invasive method. An alternating current in the transmitter coil generates a primary electromagnetic field causing an eddy current within the soil matrix. The eddy current, in turn, generates a secondary electromagnetic field within the receiving coil. The relationship between currents created from both the primary and the secondary electromagnetic fields allows for the detection of the conducting characteristics of the soil.

Previous studies have reported on different levels of soil ECa observed using the same instrumentation (18–24). Although a few studies reported relatively stable spatial patterns, these research activities did not focus on the instruments’ sensitivity to temporal and operational noise. According to Robinson et al. (25), differences in ambient and soil conditions may cause the signal to change over time (drift). For example, heat builds up in an instrument that is directly exposed to sunlight and this reduces the measured soil ECa (18, 23, 25). In contrast, cold weather may significantly reduce measured soil ECa due to a reduction in electrolyte mobility in the soil (26). Taylor and Holladay (27) found 1 mS/m offset due to the temporal drift on the DUALEM–21S sensor due to environmental noise, suspected mainly due to the gradient of the ambient temperature. Likewise, soil ECa may vary annually due to the temporal dynamics of the top soil layer (28, 29). Thus, the relationship between soil ECaand other soil properties remains uncertain.

Operational drift marks the effect of the typical soil ECa mapping exercise. The drift of soil ECa measurements could be affected by the internal, thermal drift of the instrument (19). The inductive heat is caused by the nature of the eddy current produced by EMI devices. In addition, ECa measurements were shown to be altered due to small changes in instrument height above the ground (22, 30), distance between the transmitting and receiving elements (17, 31), or as a result of the roll and pitch of the measuring instrument (32). The vegetative cover on the ground could potentially increase soil ECa due to the moisture content in the plant cells (33), and minor effects from annual crop residues (34). In general, different operational factors govern the signal propagation and when it differs from the normal position during soil ECa surveys, ECa measurements almost certaintly be altered by something as simple as using different electrode spacing (35).

Since service providers have to consider a combination of factors causing temporal and operational noise when mapping agricultural fields, the objective of this study was to quantify the deviation of stationary ECa measurements produced using different instruments over time (both, short and long term), and due to different artificially imposed operational uncertainties (height, roll and pitch).

2 Materials and methods

2.1 Instruments

Three different instruments were used to simultaneously measure soil ECa (mS/m) within the same area. These included a GCR sensor Veris Quad EC 1000 (Veris Technologies, Inc., Salina, Kansas, USA; VERIS-EC) shown in Figure 1 and two EMI instruments: DUALEM-21S (Dualem, Inc., Milton, Ontario, Canada) and EM-38 (Geonics Limited, Mississauga, Ontario, Canada) shown in Figure 2. Table 1 summarizes the main parameters of these instruments.

Figure 1

Figure 2

Table 1

SpecificationVERIS-ECEM-38DUALEM-21S
MethodGCREMIEMI
Dimensions, m1.43 x 1.50 x 0.691.06 x 0.15 x 0.132.41 x 0.09 x 0.09
Mass, kg13635
Power supply12 V DC external9 V DC internal12 V DC external
Number of depths124
Operating frequency20 Hz14.6 kHz9 kHz
Data output rate1 Hz14 Hz5 Hz
Year of manufacture201220042012

Instrument specifications.

The VERIS-EC used in this study consisted of four rolling coulters and provided output related to shallow (0-30 cm) soil ECa. The DUALEM-21S consisted of a 2.41 m long tube and had one transmitter coil and four receiving coils. Two of these four coils form a horizontal coplanar (HCP) array at 1 m (DUALEMHCP-1) and 2 m (DUALEMHCP-2) distances whereas the other two form a perpendicular coplanar (PRP) array at 1.1 m (DUALEMPRP-1.1) and 2.1 m (DUALEMPRP-2.1) distances. The sensing depths for all configurations can be found in Table 2. Finally, the EM-38 had only one pair of coplanar coils 1 m apart. The unit can be positioned in a horizontal dipole or a vertical dipole mode producing ECa measurements related to 0.75 and 1.55 m deep soil profiles, respectively. This unit was calibrated before each use according to the manufacturer’s recommendations. Since the vertical dipole is the same as HCP, EM–38HCP-1 and DUALEMHCP-1 measurements are comparable (21), the EM-38 instrument was tested only in the vertical dipole configuration. All instruments went through the warming up period for about 5 minutes before each test event.

Table 2

Recorded measurementInstrumentArray configurationDistance, mEffective sensing depth (75% response), m
VERIS-ECVeris Quad EC 1000Wenner0.250.30
EM–38HCP-1EM–38Vertical dipole (Horizontal coplanar)1.001.55
DUALEMHCP-1DUALEM–21SHorizontal coplanar1.001.55
DUALEMPRP-1.1DUALEM–21SPerpendicular coplanar1.100.54
DUALEMHCP-2DUALEM–21SHorizontal coplanar2.003.18
DUALEMPRP-2.1DUALEM–21SPerpendicular coplanar2.101.03

List of recorded measurements.

A LabView (National Instruments, Corp., Austin, Texas, USA) application has been developed to automatically log data from the three sensors at individual data rates. A Watch Dog 2700 weather station (Spectrum Technologies, Inc., Aurora, Illinois, USA) was used to record ambient conditions that might affect instrument performances. Monitored ambient parameters were logged with a 5-min interval and included: air temperature and humidity, wind speed and direction, and rainfall. The same station was used to monitor soil temperature and water content 30 cm below the surface using an installed SMEC 300 (Spectrum Technologies, Inc., Aurora, Illinois, USA) stationary probe.

2.2 Experimental procedure

The instruments were placed in stationary positions approximately 8 m apart and about 6 m away from the data logging station, as shown in Figure 3. The setup distance was used to prevent signal distortion and interference with sensor readings. The test area at Macdonald Farm of McGill University, Quebec, Canada, was a regularly cut lawn approximately 2 m from the edge of a corn field. The soil type at the test location was identified as Chicot series, sandy loam with moderate water holding capacity, and moderate to poor drainage (37) and had relatively low soil ECa.

Figure 3

A series of five 4.5-h data recordings were conducted from August to October. Each time, the instruments were placed in the same marked locations. The GCR coulter disks were pushed down gently (about 5 – 10 cm deep) to ensure good contact with the soil. At the same time, the EMI instruments were placed on the flat ground with the roll and pitch of the instruments as close to 0° (normal position) as possible. Another set of 5-min data recordings was conducted over several days from September to November with artificially introduced operational noise. Evaluated factors included: a) 10 cm height above the ground simulating an inconsistent distance between the instrument and soil surface, b) +10° and -10° pitch simulating potential raising of one end of the instrument, and c) +10° and -10° roll simulating deviation of the instrument from its vertical orientation (Figure 4) during a typical mapping exercise. The 0 cm height with 0° roll or pitch represents the typical normal position of the EMI sensors when placed on the ground during the mapping operation. The Table 3 summarizes all data acquisition events that allowed five replicates of temporal and three replicates of operational tests for every instrument.

Figure 4

Table 3

Instrument and operationReplicates on different test events
12345
Temporal test (normal operation)
VERIS-EC12-Aug13-Aug18-Sep09-Oct24-Oct
EM-3813-Aug18-Sep09-Oct24-Oct29-Oct
DUALEM-21S13-Aug18-Sep09-Oct24-Oct29-Oct
Operational test
EM-380 cm height16-Sep17-Sep23-Oct
10 cm height16-Sep17-Sep23-Oct
+ 10° roll16-Sep17-Sep23-Oct
0° roll16-Sep10-Oct23-Oct
– 10° roll16-Sep17-Sep23-Oct
+ 10° pitch16-Sep10-Oct23-Oct
0° pitch10-Oct23-Oct23-Oct
– 10° pitch16-Sep17-Sep23-Oct
DUALEM-21S0 cm height17-Sep22-Oct23-Oct
10 cm height17-Sep10-Oct23-Oct
+ 10° roll17-Sep22-Oct10-Oct
0° roll17-Sep22-Oct23-Oct
– 10° roll17-Sep22-Oct10-Oct
+ 10° pitch17-Sep10-Oct23-Oct
0° pitch23-Oct23-Oct23-Oct
– 10° pitch17-Sep10-Oct23-Oct

Experimental timeline of CGR and EMI sensors for temporal and operational induced tests.

2.3 Data analysis

Data analysis was based on a comparison of 1-s data obtained at the highest possible rate without any filtering. While the temporal tests quantify the potential data drift from the beginning to the end of a single mapping exercise, the operational tests reveal the influence of typical uncertainties of the position of the instrument with respect to the ground. In addition, the test replicates show the influence of ambient conditions along with the possible uncertainties of sensor repositioning and other feasible inconstancies between test replicates.

For both temporal and operational tests, descriptive statistics, such as mean and standard deviation (STD) of each test replicate, were calculated. Root mean square errors (RMSE) for the temporal tests were estimated using the following equation:

where n is the number of 1-s measurement averaged within any specific data log e.g. for 4.5 h; m is the number of different logging events of the test replicates e.g. 5 replications.

The Levene’s test of equal variances (e.g. 38) was conducted to compare mean square error (MSE) values corresponding to different instruments using the raw dataset. Due to a very large number of data records, high degrees of freedom made relatively similar variance estimates significantly different from each other. Therefore, a subjective grouping of similar RSME estimates was performed to facilitate the discussion. Thus, RMSE values less than 0.01 mS/m will be considered temporarily the most stable measurements, 0.01-0.50 mS/m as temporarily relatively stable measurements, and 0.5 mS/m or more as temporarily relatively unstable measurements. A simple linear regression was applied to the relationships between ECa measurements and ambient conditions, including soil and air temperature, soil water content, air humidity, and internal temperature of the DUALEM-21S instrument. In terms of the operational test, a t–test using α = 0.05 was used to compare the means of three operational test replicates to the mean of nine replicates representing normal operation of the instrument (i.e., zero height, roll and pitch).

3 Results and discussions

3.1 Temporal test

Figure 5 indicates the range of air and soil temperatures, relative humidity, soil water content, and recorded internal instrument temperature of the DUALEM–21S during each 4.5-h temporal test. These tests generally cover all reasonable operational conditions when soil ECa data are normally collected. The weather data captured from the weather station showed ambient and soil temperatures varying from 23.3 °C to freezing (-0.1 °C) and 29.5 to 7.6 °C, respectively. The latter measurements slightly vary within the same measurement date; however, they change greatly from one test event to another. The internal temperature of the DUALEM-21S ranged from 6 to 40 °C across the test dates. Assuming the ambient temperature effect is similar on all instruments, this temperature data then was used as a basis for the comparison between all these three instruments. The increase in soil moisture on 9-Oct was due to rainfall events during the two days prior to the test (6 mm of total precipitation).

Figure 5

Figure 6 illustrates data logs for four different measurements obtained during the 9-Oct test. The ranges (minimum and maximum) for unprocessed soil ECa measurements for the entire temporal test are presented in Figure 7. Table 4 summarizes the average, STD, and RMSE (Equation 1) values. The most stable soil ECa measurements were from the GCR instrument. Earlier, Serrano et al. (33) observed a similar level of consistency of CGR measurements. Both DUALEM PRP measurements produced RMSE values 5-10 times smaller than those from the EM-38 or DUALEM HCP measurements. In addition to the 4.5-h drift of ECa measurements, there were noticeable changes from day to day. For an unknown reason, the most apparent reduction in ECa measurements was on 18-Sep for both DUALEM HCP measurements, but not for PRP. That day, the initial internal and ambient temperatures were similar (10.4 and 11.6°C), but a steady increase of the ambient temperature with relatively low wind speed (around 2 km/h) may have resulted in rapid solar warming of the instrument. This typically reduces soil ECa measurements. However, it is not certain what caused this sensor behaviour.

Figure 6

Figure 7

Table 4

MeasurementReplicateAverage ECa and STD between replicates, mS/mRMSE, mS/m
12345
VERIS-EC3.00 (0.01)*4.00 (<0.01)4.00 (<0.01)3.70 (<0.01)2.70 (<0.01)3.56
(0.70)
< 0.01a
EM–38HCP-14.28 (0.58)9.12 (1.79)4.28 (0.58)8.64 (0.89)8.53 (0.88)6.97
(2.46)
1.08c
DUALEMHCP-18.34 (1.01)-2.98 (1.60)10.79 (0.78)8.64 (0.27)8.79 (0.83)6.72
(5.51)
1.03c
DUALEMHCP-22.79 (0.74)1.50 (1.57)2.95 (0.87)6.41 (0.38)5.96 (0.41)3.92
(2.15)
0.99c
DUALEMPRP-1.17.49 (0.11)0.68 (0.10)6.48 (0.09)6.56 (0.07)5.47 (0.07)5.34
(2.70)
0.10b
DUALEMPRP-2.18.51 (0.22)6.78 (0.17)7.43 (0.15)7.81 (0.13)7.40 (0.13)7.59
(0.64)
0.17b

ECa (mS/m) measurements for temporal tests.

*Average and standard deviation (in parenthesis) of replicated tests.

a

Temporarily the most stable measurements.

b

Temporarily relatively stable measurements.

c

Temporarily relatively unstable measurements.

Table 5 summarizes the correlation coefficients for a linear regression between ambient conditions and recorded measurements. Figure 8 demonstrates the relationships between air, soil and internal DUALEM instrument temperatures with several ECa measurements. It is obvious that an anomaly, such as the 18-Sep drop in DUALEM HCP measurements, affected the observed relationships. This anomaly cannot be explained by ambient conditions and may be affiliated with a number of unaccounted for factors, such as instrument positioning and the conditions of surrounding vegetation. When disregarded, it appears that the EM-38 measurements are negatively correlated with ambient and internal temperatures. According to Allred et al. (19), low soil water content and high temperature normally reduces soil ECa. Sudduth et al. (18) reported that the drift over 10% of ECa observed during field mapping using the EM-38 might be due to a change in internal temperature rather than ambient temperature variations. Corwin and Lesch (11) recommend converting ECa measurements at a specific temperature to measurements at a reference temperature (e.g., 25°C). Naturally, this would mean that temperature-compensated VERIS-EC and DUALEM-21S measurements would not be affected by ambient conditions to the extent of non-compensated EM-38 measurements. However, the presented data have not revealed temperature-induced changes in EM-38 measurements greater than other effects, such as instrument repositioning. The effects of soil temperature and water content are less quantifiable since they did not change significantly during individual tests.

Table 5

MeasurementTemperature, °CAir humidity, %Soil water content, %
AmbientSoilInternal DUALEM-21S
VERIS-EC0.3690.1450.867*0.0640.029
EM–38HCP-1– 0.663– 0.525– 0.724*– 0.449– 0.896*
DUALEMHCP-1– 0.173– 0.132– 0.0520.1020.552
DUALEMHCP-2– 0.823*– 0.555– 0.816*– 0.152– 0.309
DUALEMPRP-1.1– 0.0090.1570.0820.3680.638
DUALEMPRP-2.10.5270.5610.3320.6160.588

Pearson coefficients of correlation between ECa measurements and measurement conditions.

*Significant relationship (α = 0.05).

Figure 8

3.2 Operational test

Figure 9 provides the results of the operational tests (minimum and maximum values) for both EMI sensors for height (0 and 10 cm), roll (−10°, 0°, +10°) and pitch (−10°, 0°, +10°) tests. Each 5-min data log represented a particular test configuration that was repeated in random order on three different occasions during at least two different days. Since normal operation (zero height, pitch and roll) was part of each operational test, this configuration has been replicated nine times. Table 6 shows the individual soil ECa test average, STD and t-test p-values. In this case, the average of three operational test replicate means were compared with the average of nine normal operation means.

Figure 9

Table 6

MeasurementHeight effect test
0 cm10 cmp-value
EM–38HCP-16.59 (1.93)4.67 (2.31)0.13
DUALEMHCP-14.81 (8.2)7.28 (4.02)0.26
DUALEMHCP-24.16 (3.26)2.36 (2.96)0.21
DUALEMPRP-1.15.19 (3.25)4.16 (1.24)0.24
DUALEMPRP-2.17.51 (0.92)6.40 (0.84)0.06
Roll effect test
0°-10°p-value+10°p-value
EM–38HCP-16.59 (1.93)4.55 (2.63)0.144.95 (2.8)0.20
DUALEMHCP-14.81 (8.2)5.33 (8.51)0.473.50 (10.64)0.43
DUALEMHCP-24.16 (3.26)3.40 (3.27)0.373.51 (4.11)0.41
DUALEMPRP-1.15.19 (3.25)4.56 (3.03)0.394.22 (3.68)0.35
DUALEMPRP-2.17.51 (0.92)7.35 (0.92)0.407.25 (1.1)0.36
Pitch effect test
0°-10°p-value+10°p-value
EM–38HCP-16.59 (1.93)4.51 (3.01)0.163.52 (1.5)0.02**
DUALEMHCP-14.81 (8.2)7.87 (4.39)0.239.49 (2)0.10
DUALEMHCP-24.16 (3.26)2.33 (3.24)0.222.9 (1.99)0.23
DUALEMPRP-1.15.19 (3.25)6.24 (0.37)0.203.19 (0.32)0.07
DUALEMPRP-2.17.51 (0.92)7.32 (0.02)0.285.61 (0.15)< 0.01**

(The soil ECa (mS/m) measurements for operational tests.

*Average and standard deviation (in parenthesis) of replicated tests.

**Significantly different at α = 0.05.

The average of three operational test replicate means were compared with the average of nine normal operation means.

It appears that raising the instrument did not contribute to greater ECa measurement changes than the differences between replicates. In most cases, HCP measurements decrease when the instrument is raised in the air, but this may not be the case for some sensor configuraions if high ECa soil overlays less conductive subsoil. A marginal significance of the drop in average ECa caused by the raised instrument was found for DUALEMPRP-2.1 which may have been due to the relatively low ECa difference between replicates rather than the magnitude of this change. In terms of the pitch and roll tests, it appears that the 10° deviations from the normal operation did not have a significant effect on the recorded measurements. The exceptions were EM-38HCP-1 and DUALEMPRP-2.1 when the end of the instrument containing the transmitting coil was raised above the ground.

From a practical standpoint, the results of this study indicate that GCR sensing of ECa may be less sensitive to temporal effects than EMI measurements in many situations and may have be appealing for many environments test. However, the non-contact nature of EMI measurements provides versatility with respect to the measurement environment and, when designing the deployment platform, such as sled (32, 39), these instruments should stay close to the ground with zero pitch and roll. It was determined to be very important to keep the transmitting coil close to the ground. Minor deviations from these conditions do not affect measurements to a greater degree than temporal test replications.

4 Conclusion

A set of stationary tests of one GCR and two EMI instruments revealed the degree of temporal and operation-induced variations on observed measurements of ECa. While the GCR instrument was relatively immune to long-term data drifts, repositioning the EMI instruments on the soil surface at different times of the year (different soil conditions and ambient temperatures) provided more noticeable differences. Furthermore, EMI measurements were less stable during 4.5-h log periods than the CGR instrument. Also, it was noted that the PRP configuration was more stable over time than the HCP operation. The same applies to the operational tests. The effects of instrument height, roll and pitch were smaller than the differences from test event to test event, which could be attributed to a number of uncontrolled factors, including exact position of the instrument and different environmental parameters. However, practitioners should avoid, or minimize, raising the transmitting coil end of the instrument due to the reported sensitivity of ECa measurements to this experimental treatment.

Statements

Data availability statement

The original contributions presented in the study are included in the article/supplementary materials, further inquiries can be directed to the corresponding author/s.

Author contributions

AMS and VA conceptualized and designed the study, AMS collected the data, analyzed the data and drafted the manuscript, VA reviewed, and edited the manuscript. All authors contributed to the article and approved the submitted version.

Funding

This project was funded in part by Canada Foundation for Innovation (CFI) Leader Opportunity Fund (LOF), Ministry of Higher Education Malaysia (MOHE) and Universiti Putra Malaysia (UPM).

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

  • 1

    De JongEBallantyneACameronDReadD. Measurement of apparent electrical conductivity of soils by an electromagnetic induction probe to aid salinity surveys. Soil Sci Soc America J (1979) 43:810–2. doi: 10.2136/sssaj1979.03615995004300040040x

  • 2

    WilliamsBGHoeyD. The use of electromagnetic induction to detect the spatial variability of the salt and clay contents of soils. Soil Res (1987) 25:21–7. doi: 10.1071/SR9870021

  • 3

    LeschSMStraussDJRhoadesJD. Spatial prediction of soil salinity using electromagnetic induction techniques: 1. statistical prediction models: a comparison of multiple linear regression and cokriging. Water Resour Res (1995) 31:373–86. doi: 10.1029/94WR02179

  • 4

    AmiduSADunbarJA. An evaluation of the electrical-resistivity method for water-reservoir salinity studies. Geophysics (2008) 73:G39–49. doi: 10.1190/1.2938994

  • 5

    SlavichPPettersonG. Estimating the electrical conductivity of saturated paste extracts from 1: 5 soil, water suspensions and texture. Soil Res (1993) 31:73–81. doi: 10.1071/SR9930073

  • 6

    CorwinDLLeschSM. Application of soil electrical conductivity to precision agriculture: theory, principles, and guidelines. Agron J (2003) 95:455–71. doi: 10.2134/agronj2003.4550

  • 7

    TeteganMPasquierCBessonANicoullaudBBouthierABourennaneHet al. Field-scale estimation of the volume percentage of rock fragments in stony soils by electrical resistivity. Catena (2012) 92:67–74. doi: 10.1016/j.catena.2011.09.005

  • 8

    KachanoskiRWesenbeeckIVGregorickE. Estimating spatial variations of soil water content using noncontacting electromagnetic inductive methods. Can J Soil Sci (1988) 68:715–22. doi: 10.4141/cjss88-069

  • 9

    SheetsKRHendrickxJMH. Noninvasive soil water content measurement using electromagnetic induction. Water Resour Res (1995) 31:2401–9. doi: 10.1029/95WR01949

  • 10

    MichotDBenderitterYDorignyANicoullaudBKingDTabbaghA. Spatial and temporal monitoring of soil water content with an irrigated corn crop cover using surface electrical resistivity tomography. Water Resour Res (2003) 39:1138. doi: 10.1029/2002WR001581

  • 11

    CorwinDLLeschSM. Apparent soil electrical conductivity measurements in agriculture. Comput Electron Agric (2005) 46:11–43. doi: 10.1016/j.compag.2004.10.005

  • 12

    BrevikECFentonTELazariA. Soil electrical conductivity as a function of soil water content and implications for soil mapping. Precis Agric (2006) 7:393–404. doi: 10.1007/s11119-006-9021-x

  • 13

    BrillanteLBoisBMathieuOBichetVMichotDLévêqueJ. Monitoring soil volume wetness in heterogeneous soils by electrical resistivity. A field-based pedotransfer function. J Hydrology (2014) 516:56–66. doi: 10.1016/j.jhydrol.2014.01.052

  • 14

    PailletYCassagneNBrunJ-J. Monitoring forest soil properties with electrical resistivity. Biol Fertil Soils (2010) 46:451–60. doi: 10.1007/s00374-010-0453-0

  • 15

    AllredBDanielsJJEhsaniMR. Handbook of agricultural geophysics. CRC Press (2008).

  • 16

    ParasnisDS. Principles of applied geophysics. 5th ed. London, UK: Chapman & Hall (1997). p. 456.

  • 17

    PanLAdamchukVPrasherSGebbersRTaylorRDabasM. Vertical soil profiling using a galvanic contact resistivity scanning approach. Sensors (2014) 14:13243–55. doi: 10.3390/s140713243

  • 18

    SudduthKADrummondSTKitchenNR. Accuracy issues in electromagnetic induction sensing of soil electrical conductivity for precision agriculture. Comput Electron Agric (2001) 31:239–64. doi: 10.1016/S0168-1699(00)00185-X

  • 19

    AllredBEhsaniMRSaraswatD. Comparison of electromagnetic induction, capacitively-coupled resistivity, and galvanic contact resistivity methods for soil electrical conductivity measurement. Appl Eng Agric (2006) 22:215–30. doi: 10.13031/2013.20283

  • 20

    AbduHRobinsonDJonesSB. Comparing bulk soil electrical conductivity determination using the DUALEM-1S and EM38-DD electromagnetic induction instruments. Soil Sci Soc America J (2007) 71:189–96. doi: 10.2136/sssaj2005.0394

  • 21

    SaeyTSimpsonDVermeerschHCockxLVan MeirvenneM. Comparing the EM38DD and DUALEM-21S sensors for depth-to-clay mapping. Soil Sci Soc America J (2009) 73:7–12. doi: 10.2136/sssaj2008.0079

  • 22

    SimpsonDVan MeirvenneMSaeyTVermeerschHBourgeoisJLehouckAet al. Evaluating the multiple coil configurations of the EM38DD and DUALEM-21S sensors to detect archaeological anomalies. Archaeological Prospection (2009) 16:91–102. doi: 10.1002/arp.349

  • 23

    SudduthKAKitchenNRMyersDBDrummondST. Mapping depth to argillic soil horizons using apparent electrical conductivity. J Environ Eng Geophysics (2010) 15:135–46. doi: 10.2113/JEEG15.3.135

  • 24

    UrdanozVAragüésR. Comparison of geonics EM38 and dualem 1S electromagnetic induction sensors for the measurement of salinity and other soil properties. Soil Use Manage (2012) 28:108–12. doi: 10.1111/j.1475-2743.2011.00386.x

  • 25

    RobinsonDALebronILeschSMShouseP. Minimizing drift in electrical conductivity measurements in high temperature environments using the EM-38. Soil Sci Soc America J (2004) 68:339–45. doi: 10.2136/sssaj2004.3390

  • 26

    AllredBEhsaniMSaraswatD. The impact of temperature and shallow hydrologic conditions on the magnitude and spatial pattern consistency of electromagnetic induction measured soil electrical conductivity. Trans ASAE (2005) 48:2123–35. doi: 10.13031/2013.20098

  • 27

    TaylorRHolladayJ. Accurate electromagnetic measurement of apparent conductivity: issues and applications. In 3rd Global Workshop on Proximal Soil Sensing (2013) 2013:62.

  • 28

    BrevikEFentonTHortonR. Effect of daily soil temperature fluctuations on soil electrical conductivity as measured with the geonics® EM-38. Precis Agric (2004) 5:145–52. doi: 10.1023/B:PRAG.0000022359.79184.92

  • 29

    FarahaniHBuchleiterG. Temporal stability of soil electrical conductivity in irrigated sandy fields in Colorado. Trans ASAE (2004) 47:79–90. doi: 10.13031/2013.15873

  • 30

    DoolittleJSudduthKKitchenNIndoranteS. Estimating depths to claypans using electromagnetic induction methods. J Soil Water Conserv (1994) 49:572–5.

  • 31

    RoyA. Depth of investigation in wenner, three-electrode and dipole-dipole DC resistivity methods. Geophysical Prospecting (1972) 20:329–40. doi: 10.1111/j.1365-2478.1972.tb00637.x

  • 32

    AdamchukVSuAMEigenbergRAFergusonRB. Development of an angular scanning system for sensing vertical profiles of soil electrical conductivity. Trans ASABE (2011) 54(3):757–67. doi: 10.13031/2013.37091

  • 33

    SerranoJShahidianSSilvaJ. Spatial and temporal patterns of apparent electrical conductivity: DUALEM vs. veris sensors for monitoring soil properties. Sensors (2014) 14:10024–41. doi: 10.3390/s140610024

  • 34

    BrevikEFentonTLazariA. Differences in EM-38 readings taken above crop residues versus readings taken with instrument-ground contact. Precis Agric (2003) 4:351–8. doi: 10.1023/A:1026319307801

  • 35

    de Assis SilvaSdos SantosROde QueirozDMde Souza LimaJSPajehúLFMedauarCC. Apparent soil electrical conductivity in the delineation of management zones for cocoa cultivation. Inf Process Agric (2022) 9(3):443–55. doi: 10.1016/j.inpa.2021.04.004

  • 36

    Veris Technologies, Inc. (2014). Available at: http://www.veristech.com/the-soil/soil-ec (Accessed 17 November 2014).

  • 37

    LajoiePG. Soil survey of argenteuil, two mountains and terrebonne counties, Quebec (1960). Research Blanch, Canada Department of Agriculture in co-operation with Quebec Department of Agriculture and Macdonald College, McGill University. Available at: http://sis.agr.gc.ca/cansis/publications/surveys/pq/pq2/index.html (Accessed 8 November 2014).

  • 38

    National Institute of Standards and Technology (NIST). U.S. department of commerce (2022). Available at: https://www.itl.nist.gov/div898/handbook/eda/section3/eda35a.htm (Accessed 31st December 2022).

  • 39

    PeraltaNRAlessoCACostaJLMartinNF. Mapping soil depth in southern pampas Argentina using ancillary data and statistical learning. Soil Sci Soc America J (2022) 86(1):65–78. doi: 10.1002/saj2.20350

Summary

Keywords

electromagnetic inductance, galvanic contact resistivity, proximal soil sensing, stability, spatial soil heterogeneity

Citation

Mat Su AS and Adamchuk VI (2023) Temporal and operation-induced instability of apparent soil electrical conductivity measurements. Front. Soil Sci. 3:1137731. doi: 10.3389/fsoil.2023.1137731

Received

04 January 2023

Accepted

03 April 2023

Published

20 April 2023

Volume

3 - 2023

Edited by

Pierre Roudier, Manaaki Whenua Landcare Research, New Zealand

Reviewed by

Brendan Malone, Commonwealth Scientific and Industrial Research Organisation (CSIRO), Australia; Yakun Zhang, University of Wisconsin-Madison, United States

Updates

Copyright

*Correspondence: Ahmad Suhaizi Mat Su, ; Viacheslav I. Adamchuk,

This article was submitted to Pedometrics, a section of the journal Frontiers in Soil Science

Disclaimer

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Outline

Figures

Cite article

Copy to clipboard


Export citation file


Share article

Article metrics