Corrigendum: The optimal axial anatomical site for a single-slice area to quantify the total volume of visceral adipose tissue in quantitative CT

  • Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China

Article metrics

View details

3

Citations

816

Views

477

Downloads

In the published article, there were some errors in Table 1 as published. The Table 1 for the Pitch of Brilliance iCT Elite was displayed as “11” and of Somatom Force was “1”, the Reconstruction kernel of Somatom Force was displayed as “Standard”, and the DFOV was displayed as “250”. The correct statement is that the Pitch of Brilliance iCT Elite is “0.914” and of Somatom Force is “0.8”, the Reconstruction kernel of Somatom Force is “Br40”, and the DFOV for 2 CTs are “350”, etc. The corrected Table 1 and its caption appear below.

Table 1

CT parameters Brilliance iCT Elite Somatom Force
Tube voltage (kV) 120 120
Tube current-time product (mAs) automatic current selection (DoseRight Index-23) anatomic tube current modulation (CARE Dose 4D)
Pitch (approximate number) 0.914 0.8
Detector configuration (mm) 128×0.625 192×0.6
Matrix size 512×512 512×512
Slice thickness/increment (mm) 1.0/1.0 1.0/1.0
Reconstruction kernel Standard Br40
DFOV (mm) 350 350
Acquisition mode Helical Helical
Gantry rotation times (s) 0.5 0.5

Summary of acquisition parameters of 2 CT scanners.

CT, computed tomography; DFOV, display field of view.

The authors apologize for this error and state that this does not change the scientific conclusions of the article in any way. The original article has been updated.

Statements

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Summary

Keywords

optimal anatomical axial site, volume prediction equation, visceral adipose tissue, QCT, total VAT

Citation

Chen S, Ma D, Su D, Li Y, Yu X, Jiang Y, Gao J and Wu Y (2022) Corrigendum: The optimal axial anatomical site for a single-slice area to quantify the total volume of visceral adipose tissue in quantitative CT. Front. Endocrinol. 13:1039351. doi: 10.3389/fendo.2022.1039351

Received

08 September 2022

Accepted

29 November 2022

Published

13 December 2022

Approved by

Frontiers Editorial Office, Frontiers Media SA, Switzerland

Volume

13 - 2022

Updates

Copyright

*Correspondence: Yan Wu,

This article was submitted to Obesity, a section of the journal Frontiers in Endocrinology

Disclaimer

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Outline

Cite article

Copy to clipboard


Export citation file


Share article

Article metrics