Commentary: Evaluation of ultrasound accuracy in thyroid mass measurement and its impact on 131I treatment for Graves' disease
Provisionally accepted- 1Zhejiang Chinese Medical University, Hangzhou, China
- 2Hangzhou Red Cross Hospital, Hangzhou, China
- 3Zhejiang Provincial Integrated Chinese and Western Medicine Hospital, Hangzhou, China
Select one of your emails
You have multiple emails registered with Frontiers:
Notify me on publication
Please enter your email address:
If you already have an account, please login
You don't have a Frontiers account ? You can register here
I read with great interest the recent article by Li et al. evaluating ultrasound accuracy in thyroid mass measurement and its impact on radioiodine therapy for Graves' disease1. This study used CT as the gold standard for the first time, and systematically revealed the problem of significant and systematic underestimation of ultrasound in the evaluation of large thyroid masses >20g. Through the comparison of US and CT image data of 192 patients, it was quantitatively confirmed that the average deviation of US measurement was 16.65g and the consistency was extremely poor. Based on the treatment data of 1584 Graves' disease patients, it was determined that thyroid mass was an independent key factor affecting the success rate of the first ¹³¹I treatment, and 35.6g was determined as an important critical value. This study directly challenges the routine clinical practice of relying on US to calculate ¹³¹I dose, and proposes that for thyroid gland >20g, CT calibration is recommended before treatment to improve the dose accuracy, which provides an important evidence-based basis for optimizing the individualized treatment of Graves' disease. While these findings provide substantial clinical value, a few aspects could be further strengthened to enhance the study's impact. The main deficiency of this paper is that the clinical practical value of the prediction model established is still limited. Although several important factors such as disease duration, FT4, RAIU, ¹³¹I dose, and thyroid mass were included, the predictive power (AUC=0.663) of the model was only moderate, and the sensitivity was also low, which limited the direct application of the model in individualized accurate prediction. In addition, higher ¹³¹I doses were observed to be associated with an increased risk of treatment failure, which was contrary to conventional wisdom and some studies. The authors attributed this finding only to the lower upper limit of ¹³¹I dose used in their center, without providing further explanation, leaving this key result underinterpreted2. Finally, the follow-up of only 6 months is relatively short to assess the effect of the CT-calibration strategy on long-term outcomes and to capture possible late efficacy responses. Despite these opportunities for refinement, this work meaningfully advances our approach to Graves' disease. It convincingly argues that precision in thyroid volumetry is not merely technical—it is therapeutic. I look forward to seeing these insights integrated into future guidelines.
Keywords: Thyroid mass, Graves' disease, 131I treatment efficacy, Clinical predictive model, CT calibration
Received: 29 Jul 2025; Accepted: 15 Sep 2025.
Copyright: © 2025 Qi and Mou. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
* Correspondence: Xin Mou, 17357159995@163.com
Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.