ORIGINAL RESEARCH article

Front. Microbiol., 05 October 2021

Sec. Infectious Agents and Disease

Volume 12 - 2021 | https://doi.org/10.3389/fmicb.2021.714242

Factors that Influence the Reported Sensitivity of Rapid Antigen Testing for SARS-CoV-2

  • 1. Becton, Dickinson and Company, BD Life Sciences–Integrated Diagnostic Solutions, Sparks, MD, United States

  • 2. W. Harry Feinstone Department of Molecular Microbiology and Immunology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD, United States

  • 3. Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, United States

  • 4. Department of Emergency Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, United States

Abstract

Tests that detect the presence of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) antigen in clinical specimens from the upper respiratory tract can provide a rapid means of coronavirus disease 2019 (COVID-19) diagnosis and help identify individuals who may be infectious and should isolate to prevent SARS-CoV-2 transmission. This systematic review assesses the diagnostic accuracy of SARS-CoV-2 antigen detection in COVID-19 symptomatic and asymptomatic individuals compared to quantitative reverse transcription polymerase chain reaction (RT-qPCR) and summarizes antigen test sensitivity using meta-regression. In total, 83 studies were included that compared SARS-CoV-2 rapid antigen-based lateral flow testing (RALFT) to RT-qPCR for SARS-CoV-2. Generally, the quality of the evaluated studies was inconsistent; nevertheless, the overall sensitivity for RALFT was determined to be 75.0% (95% confidence interval: 71.0–78.0). Additionally, RALFT sensitivity was found to be higher for symptomatic vs. asymptomatic individuals and was higher for a symptomatic population within 7 days from symptom onset compared to a population with extended days of symptoms. Viral load was found to be the most important factor for determining SARS-CoV-2 antigen test sensitivity. Other design factors, such as specimen storage and anatomical collection type, also affect the performance of RALFT. RALFT and RT-qPCR testing both achieve high sensitivity when compared to SARS-CoV-2 viral culture.

Introduction

Severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) is the highly transmissible viral agent responsible for the development of coronavirus disease 2019 (COVID-19; ; ; Li et al., 2020; Wang et al., 2020). Based on measurements from specimen swabs, the viral load in infected individuals peaks around the time of symptom onset (approximately 2–3 days following infection; Walsh et al., 2020). This time point coincides with the highest rate of SARS-CoV-2 transmissibility. Transmissibility usually tapers off within 8 days following symptom onset (He et al., 2020). Asymptomatic individuals account for 40–45% of all infections and can transmit the virus for up to 14 days following infection (Oran and Topol, 2020). Therefore, rapid accurate diagnostic testing has been a key component of the response to COVID-19, as identification of SARS-CoV-2-positive individuals facilitates both appropriate treatment and reduced communal spread of the virus (La Marca et al., 2020).

Molecular testing using quantitative reverse transcription polymerase chain reaction (RT-qPCR) platforms has become the primary diagnostic method for COVID-19 diagnosis (Wang and Taubenberger, 2010; Food and Drug Administration, 2011; ; Tahamtan and Ardebili, 2020). The major advantage of RT-qPCR testing is its high analytical sensitivity (translating to few false-negative results; Giri et al., 2021). However, large-scale clinical laboratory testing requires a dedicated infrastructure and specialized technician training. In addition, due to the specimen transport and processing time, results for standard RT-qPCR can take days to obtain, depending on the catchment area and the demand for testing ().

Antigen-based testing involves the application of specific SARS-CoV-2 antibodies (Figure 1) in several formats, including lateral flow immunofluorescent sandwich assays, chromatogenic digital immunoassay, lateral flow immunoassay with visual read, and microfluidic immunofluorescence assays (Rezaei et al., 2020). Antigen testing for SARS-CoV-2 can be utilized either in conjunction with RT-qPCR as a first-line screening test or in decentralized health care settings in which RT-qPCR testing may not be conducive for rapid result turnaround (Rezaei et al., 2020). Rapid antigen-based lateral flow testing for SARS-CoV-2, as with influenza, has been implemented globally to achieve rapid accurate results for COVID-19 diagnosis (Peeling et al., 2021). Although the majority of antigen-based tests share a common mechanism for detection of SARS-CoV-2 protein, the reported sensitivities of both Food and Drug Administration (FDA) Emergency Use Authorization (EUA)-approved and non-EUA-approved antigen-based tests have varied greatly in the literature (). Multiple meta-analyses and systematic reviews have reported large inter-study heterogeneity related to SARS-CoV-2 antigen-based testing (Dinnes et al., 2020; COVID-19 Scientific Advisory Group Rapid Evidence Report, 2020; ). Although reliable antigen test performance coincides with a high specimen viral load (), study heterogeneity could impact our conclusions about antigen test performance. Factors that could affect overall antigen test performance include analytical sensitivity (i.e., antibody/antigen binding affinity) of the assay, which likely varies for tests across manufacturers (Mina et al., 2020), biases occurring from the study design (e.g., blinding, test order, etc.), the study population [e.g., symptomatic vs. asymptomatic, days from symptom onset (DSO), etc.], the anatomical collection site (e.g., nasopharyngeal vs. anterior nares), and specimen storage conditions (Lijmer et al., 1999; Griffith et al., 2020; ).

FIGURE 1

As others have noted previously, a wide range of reported sensitivities has been documented for rapid antigen testing (Dinnes et al., 2020; ). The main objective of this meta-analysis was to explore possible causes of the high degree of heterogeneity of assay sensitivity estimates across different studies. Data were summarized and analyzed from over 80 articles and manufacturer instructions for use (IFU) to provide results on sensitivity for SARS-CoV-2 antigen testing from more than 25 individual assays.

Materials and Methods

The methods for conducting research and reporting results for systematic reviews and meta-analyses, which are outlined by the Cochrane Collaboration Diagnostic Test Accuracy Working Group and by Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines, were employed for this study (Gatsonis and Paliwal, 2006; Leeflang, 2014; Page et al., 2020). This study protocol was registered with the PROSPERO International Prospective Register of Systematic Reviews in 2021 (PROSPERO CRD42021240421; ).

The PICO (Participants, Intervention, Comparator, and Outcomes) of this meta-analysis was as follows: Participants were individuals undergoing SARS-CoV-2 testing in a healthcare setting (at least eight cases); Intervention (primary) was the index test consisting of a SARS-CoV-2 antigen detection platform utilizing immunobiological mechanisms, such as a sandwich ELISA, combined with spatial resolution (e.g., immunochromatographic assay); Intervention (secondary) was testing for SARS-CoV-2 using antigen and RT-qPCR testing (indices 1 and 2); Comparator (primary) was RT-qPCR as the reference test for detecting SARS-CoV-2 genomic RNA (any target gene); Comparator (secondary) was SARS-CoV-2 viral culture as the reference method for identifying specimens with infectious viral particles; and Outcome was the determination of antigen test sensitivity across independent variables.

Search and Selection Criteria

Eligible studies/sources included diagnostic studies of any design type (i.e., retrospective, prospective, randomized, blinded, and non-blinded) that specifically involved the detection of SARS-CoV-2. The primary outcome was sensitivity for the detection of SARS-CoV-2 in a healthcare setting by rapid antigen testing as compared with RT-qPCR. Both MEDLINE and MedRxiv electronic databases were searched across dates ranging from January 1, 2020, to February 1, 2021, with the following search terms: (1) [(Antigen test and (sars-cov-2 OR COVID-19)] OR ((antigen[title/abstract] AND test) OR (Antigen[title/abstract] and assay)) AND (SARS-CoV-2[title/abstract] OR COVID-19[title/abstract])) and (2) ‘‘SARS-CoV-2 and antigen test or COVID-19 and antigen test.’’ In addition, a search was performed on the FDA database1 for all EUA SARS-CoV-2 antigen tests. All retrieved sources were assessed for relevance using predetermined inclusion/exclusion criteria. The inclusion criteria consisted of the following: (1) SARS-CoV-2 diagnostic target; (2) Sensitivity as a performance outcome; (3) Compares antigen testing performance with RT-qPCR as reference; (4) Population includes symptomatic and/or asymptomatic participants; (5) Human study; (6) English language; and (7) Any region, country, or state. Secondary inclusion subcriteria for analyses included the following: (S1) Index performance results that were stratified by viral load or by RT-qPCR (reference) cycle threshold (Ct); (S2) Delineated specimens for reference and index testing between symptomatic and asymptomatic participants; (S3) Delineated the anatomical site for specimen collection prior to reference and index testing; (S4) Delineated whether the specimen was frozen prior to reference testing; (S5) Specified whether the specimen was frozen prior to index testing; (S6) Analytical limit of detection (LOD) information was available for the reference assay; and (S7) The index test manufacturer information was available. The exclusion criteria included the following: (1) Article/source from a non-credible source; (2) Article/source contains an unclear or indistinct research question; (3) Does not contain performance data specific to SARS-CoV-2; (4) Does not identify or does not involve standard upper respiratory SARS-CoV-2 specimens (e.g., contains other specimen types such as serum or saliva); (5) Contains no RT-qPCR reference results for comparison; (6) Data were collected in an unethical manner; (7) The index test involves a mechanism other than SARS-CoV-2 antigen detection involving a lateral flow (or similar) design; (8) Data not conducive for extraction required for analysis; and (9) No data regarding true-positive and false-negative rates for the index test relative to the reference test. Additional secondary exclusion criteria included (S1) Article/source not in the English language; and (S2) Study did not involve humans.

Full-text reviews of the articles that passed initial screening were performed to identify sources that met inclusion/exclusion criteria involving study methodologies, specimen collection, SARS-CoV-2 test details, data type (sensitivity, specificity values, etc.) and format [raw data, only point estimates and 95% confidence intervals (95% CI) included, etc.]. The information was then entered into data extraction tables to document study characteristics and to record raw data with calculated point estimates and 95% CIs. A modified Newcastle–Ottawa Scale was used to evaluate the risk of bias (individual study quality; Wells et al., 2011), which included the following bias domains: detection (measurement of test result), reporting (failure to adequately control confounding, failure to measure all known prognostic factors), and spectrum (eligibility criteria, forming the cohort, and selection of participants). Risk of bias summary assessments for individual studies were categorized as “high,” “moderate,” or “low.” The overall quality of evidence for the risk estimate outcomes (all included studies) was obtained using a modified Grading of Recommendations, Assessment, Development and Evaluation (Schunemann et al., 2013) methodology for observational diagnostic studies.

The seven domains used to ascertain the overall study quality and strength across the six independent variables were (1) Confounder effect; (2) Consistency; (3) Directness; (4) Magnitude of effect; (5) Precision; (6) Publication bias; and (7) Risk of bias (ascertained from individual studies). Study subgroups were considered high quality when ≥4 of seven domains received a green rating, with no red ratings, and <3 unclear ratings; otherwise, it was considered moderate quality. Study subgroups were considered moderate quality when three domains were green with <3 red domains; or when two domains were green and <3 domains were red with <4 domains unclear; or when one domain was green with <2 red domains and <3 domains were unclear; or when no domains were green, no domains were red, and <2 domains were unclear. Any other combination of ratings resulted in a classification of quality as low.

Subgroup meta-analysis was performed for the following factors: (1) viral load with fixed cutoff values; (2) symptomatic vs. asymptomatic; (3) ≤7 DSO vs. any DSO; (4) anatomical collection type for specimens used for both index and reference testing (anterior nares/mid-turbinate vs. nasopharyngeal/oropharyngeal); (5) specimen storage conditions (fresh vs. frozen); (6) analytical sensitivity of the reference RT-qPCR test [detection cutoff < 500 genomic copies/ml (cpm) vs. ≥500 cpm]; and (7) assay manufacturer.

Data Analysis

Data extraction was accomplished by two reviewers/authors with any discrepancies adjudicated by a third reviewer/author. An independent author performed all statistical methods. All analyses were performed using R software (version 4.0.2) (R Core Team, 2020) along with the meta () and metaphor (Viechtbauer, 2010) packages. For each study, the sensitivity of the index test along with 95% Clopper–Pearson CI was calculated. Logit-transformed sensitivity values were combined to obtain random effect estimates of overall sensitivity. The same method was applied to subgroup meta-analyses; subgroups were defined by disease status, reference and test collection type, reference and test storage (fresh/frozen), study spectrum bias, reference analytical sensitivity (high and low), and manufacturer. Q-tests for heterogeneity based on random-effects models with common within-group variability were used to evaluate statistical differences between subgroups (univariate analysis). Moderators with significant heterogeneity in the subgroup analysis were included in a meta-regression mixed-effects model. Forest plots were generated for all subgroup analyses; a funnel plot of all logit-transformed sensitivities was generated without taking into account study characteristics, and another funnel plot of residual values was generated after fitting the meta-regression model. Separately, for articles where viral load information was available, subgroup meta-analysis by viral load (either measured by RT-PCR Ct of 25 or 30 or a viral cpm of 1 × 105) and symptomatic status was performed. The minimum number of studies required for synthesis is n = 3.

Results

At the outset, 1,695 sources were identified during the database search (Figure 2). From that group of candidate sources, screening was performed by title and abstract, and the potential pool of articles was reduced, and 148 underwent full-text review for data extraction. 83 articles/sources of the 148 were chosen for meta-analysis (Table 1) based upon further exclusion criteria (see section “Materials and Methods”). Note that a list of excluded sources with their specific exclusion criteria is available upon request from the authors. Of the 83 source studies, 76 (91.6%) involved a cross-sectional study design. Data from 12 of the sources were from validation studies as part of EUA from the FDA and can be found in each, respective, manufacturer IFU. 22 of the studies were conducted in the United States, nine in Spain, seven each from Germany and Japan, six from Italy, four from China, three each from France, Switzerland, and the United Kingdom, and two each from Belgium and Chile; the rest of the countries represented in this study had only one. 135 individual data sets were utilized in total from the 83 articles/sources; 30 articles provided more than one data set. The overall combined number of specimens from participants, across all 83 studies, was 53,689; the overall total number of RT-qPCR reference positive results for estimating sensitivity from all 135 data sets was 13,260.

FIGURE 2

TABLE 1

RFIDSource RFIDCountryTotal NReference (+)Index (Antigen) testIndex manufacturerRef. (RT-PCR) testRef. manufacturer
1Egypt310190BIOCREDIT COVID-19 Antigen TestRapiGen Inc., South KoreaNot availableNot available
2Bahrain4,183734Abbott Diagnostic GmbH, Jena, GermanyAbbott Diagnostic GmbH, GermanyTaqPathTM COVID-19 Multiplex KitThermo Fisher, United States
3Spain41256PanbioTM COVID-19 Ag Rapid Test DeviceAbbott Diagnostic GmbH, Jena, GermanyTaqPathTM COVID-19 Multiplex KitThermo Fisher, United States
4 (sx/asx)Spain1,406954PanbioTM COVID-19 Ag Rapid Test DeviceAbbott Diagnostic GmbH, Jena, GermanyNot availableNot available
5Japan51026Lumipulse® SARSCoV-2 Ag kitFujirebio Inc., Tokyo, JapanTaqMan® Fast Virus 1-StepThermo Fisher Scientific, United States
6Japan12966Espline® SARS-CoV-2Fujirebio Inc., JapanTaqMan® Fast Virus 1-StepThermo Fisher Scientific, United States
7United States34663Quidel Sofia® SARS FIAQuidel, San Diego, CA, United StatesCepheid Xpert® XpressCepheid, United States
8aSwitzerland535126PanbioTM COVID-19 Ag Rapid Test DeviceAbbott Diagnostic GmbH, GermanyRoche cobas® SARS-CoV-2 AssayRoche Diagnostics, Switzerland
8b529193STANDARD QTM COVID-19 Ag TestSD Biosensor, South KoreaRoche cobas® SARS-CoV-2 AssayRoche Diagnostics, Switzerland
9 (sx/asx)Spain1,369155PanbioTM COVID-19 Ag Rapid Test DeviceAbbott Diagnostic GmbH, GermanyTaqPath COVID-19 Multiplex KitThermo Fisher Scientific, United States
10Italy330107STANDARD QTM COVID-19 Ag TestSD Biosensor, South KoreaSeegene Allplex® 2019 n-CoV AssaySeegene Inc., South Korea
11Thailand45463STANDARD QTM COVID-19 Ag TestSD Biosensor, South KoreaSeegene Allplex® 2019 n-CoV AssaySeegene Inc., South Korea
12Italy5043COVID-19 Ag Respi-StripCoris BioConcept, BelgiumSeegene Allplex® 2019 n-CoV AssaySeegene Inc., South Korea
13Colavita et al., 2020Italy941208STANDARD FTM COVID-19 Ag FIASD Biosensor, South KoreaRoche cobas® SARS-CoV-2 AssayRoche Diagnostics, Switzerland
14Courtellemont et al., 2021France248125COVID-VIRO®AAZ, FranceTaqPath COVID-19 Multiplex KitThermo Fisher Scientific, United States
15Diao et al., 2020China251205SARS-CoV-2 AntigenFIC Assay (in house)In-houseTaqMan One-Step RT-PCR KitDa An Gene, China
16Drain et al., 2020United States; United Kingdom512186LumiraDxTM SARS-CoV-2 Ag TestLumiraDx, United KingdomRoche cobas® SARS-CoV-2 AssayRoche Diagnostics, Switzerland
17a (sx/asx)Drevinek et al., 2020Czech R.591596PanbioTM COVID-19 Ag Rapid Test DeviceAbbott Diagnostic GmbH, Jena, GermanySeegene Allplex® 2019 n-CoV AssaySeegene Inc., South Korea
17b (sx/asx)STANDARD FTM COVID-19 Ag FIASD Biosensor, South KoreaSeegene Allplex® 2019 n-CoV AssaySeegene Inc., South Korea
18a (sx/asx)Favresse et al., 2021Belgium188101Biotical SARS-CoV-2 Ag cardBiotical Health, SLU, SpainLightMix®Roche Diagnostics, Switzerland
18b (sx/asx)101PanbioTM COVID-19 Ag Rapid Test DeviceAbbott Diagnostic GmbH, GermanyLightMix®Roche Diagnostics, Switzerland
18c (sx/asx)100Coronavirus Ag Rapid Test CassetteHealgen Scientific, LLC, United StatesLightMix®Roche Diagnostics, Switzerland
18d (sx/asx)100Roche SARS-CoV-2 Rapid Antigen TestRoche Diagnostics, SwitzerlandLightMix®Roche Diagnostics, Switzerland
18e (sx/asx)101VITROS SARS-CoV-2 Antigen testOrtho Clinical Diagnostics, United StatesLightMix®Roche Diagnostics, Switzerland
19 (sx/asx)Fenollar et al., 2021France341208PanbioTM COVID-19 Ag Rapid Test DeviceAbbott Diagnostic GmbH, GermanyVita PCR SARS-CoV-2 AssayCredo Diagnostics, Singapore
20Gremmels et al., 2021Netherlands; Aruba1,369206PanbioTM COVID-19 Ag Rapid Test DeviceAbbott Diagnostic GmbH, GermanySeegene Allplex® 2019 n-CoV AssaySeegene Inc., South Korea
21Hirotsu et al., 2020Japan31361Lumipulse® SARS-CoV-2 Ag kitFujirebio Inc., JapanTaqMan Fast Virus 1-Step Master MixThermo Fisher Scientific, United States
22Hirotsu et al., 2021Japan2723Lumipulse® SARS-CoV-2 Ag kitFujirebio Inc., JapanNot availableNot available
23Hoehl et al., 2020Germany7119RIDA® QUICK SARS-CoV-2 Antigen testR-Biopharm, Darmstadt, GermanyRoche cobas® SARS-CoV-2 AssayRoche Diagnostics, Switzerland
24Houston et al., 2021United Kingdom728284Innova SARS-CoV-2 Antigen Rapid TestLotus Global Company, United KingdomNot availableNot available
25aJääskeläinen et al., 2021Finland188152Quidel Sofia® SARS FIAQuidel, San Diego, CANot availableNot available
25b189162STANDARD QTM COVID-19 Ag TestSD Biosensor, South KoreaNot availableNot available
25c190156PanbioTM COVID-19 Ag Rapid Test DeviceAbbott Diagnostic GmbH, GermanyNot availableNot available
26 (sx/asx)Jakobsen et al., 2021aDenmark196148STANDARD QTM COVID-19 Ag TestSD Biosensor, South KoreaLuna One-step RT-qPCR kitNew England Biolabs, United States
27 (sx/asx)James et al., 2021United States2,339156BinaxNOWTM COVID-19 Ag Card test kitAbbott Diagnostics Inc., United StatesPerkinElmer SARS-CoV-2 RT-PCRPerkinElmer, Inc., United States
28Kashiwagi et al., 2020Japan1626ESPLINE® SARS-CoV-2 testFujirebio Inc., JapanNot availableNot available
29aKohmer et al., 2021Germany10076RIDA® QUICK SARS-CoV-2 Antigen testR-Biopharm, Darmstadt, GermanyRoche cobas® SARS-CoV-2 AssayRoche Diagnostics, Switzerland
29bRoche SARS-CoV-2 Rapid Antigen TestRoche Diagnostics, SwitzerlandRoche cobas SARS-CoV-2 AssayRoche Diagnostics, Switzerland
29cNADAL® COVID-19 Ag TestNal von Minden GmbH, GermanyRoche cobas® SARS-CoV-2 AssayRoche Diagnostics, Switzerland
29dLumiraDxTM SARS-CoV-2 Ag TestLumiraDx, United KingdomRoche cobas® SARS-CoV-2 AssayRoche Diagnostics, Switzerland
30aKrüger et al., 2020Germany; United Kingdom41711COVID-19 Ag Respi-StripCoris BioConcept, BelgiumRoche cobas® SARS-CoV-2 AssayRoche Diagnostics, Switzerland
30b72718BIOEASYTM 2019-nCoV Ag Rapid TestBIOEASY Technology, ChinaRoche cobas® SARS-CoV-2 AssayRoche Diagnostics, Switzerland
30c1,26750STANDARD QTM COVID-19 Ag TestSD Biosensor, South KoreaRoche cobas® SARS-CoV-2 AssayRoche Diagnostics, Switzerland
31Krüttgen et al., 2021Germany15077Roche SARS-CoV-2 Rapid Antigen TestRoche Diagnostics, SwitzerlandReal Star SARS-CoV-2 RT PCR KitAltona, Germany
32Lambert-Niclot et al., 2020France13896COVID-19 Ag Respi-StripCoris BioConcept, BelgiumMultiple tests usedMultiple manufacturers used
33Linares et al., 2020Spain14190Abbott Diagnostic GmbH, Jena, GermanyAbbott Diagnostic GmbH, GermanySeegene Allplex® 2019 n-CoV AssaySeegene Inc., South Korea
34Lindner et al., 2020Germany28741STANDARD QTM COVID-19 Ag TestSD Biosensor, South KoreaRoche cobas® SARS-CoV-2 AssayRoche Diagnostics, Switzerland
35Lindner et al., 2021Germany14682STANDARD QTM COVID-19 Ag TestSD Biosensor, South KoreaRoche cobas® SARS-CoV-2 AssayRoche Diagnostics, Switzerland
36Liotti et al., 2020Italy359107STANDARD FTM COVID-19 Ag FIASD Biosensor, South KoreaMultiple tests usedMultiple manufacturers used
37Liu et al., 2021China9917In-house assayNot applicableNot availableNot available
38aMak et al., 2020China140143COVID-19 Ag Respi-StripCoris BioConcept, BelgiumNot availableNot available
38bNADAL® COVID-19 Ag TestNal von Minden GmbH, GermanyNot availableNot available
38cSTANDARD QTM COVID-19 Ag TestSD Biosensor, South KoreaNot availableNot available
39Mak et al., 2021China105108Abbott Diagnostic GmbH, Jena, GermanyAbbott Diagnostic GmbH, GermanyNot availableNot available
40 (sx/asx)Masiá et al., 2020Spain91340Abbott Diagnostic GmbH, Jena, GermanyAbbott Diagnostic GmbH, GermanyRoche cobas® SARS-CoV-2 AssayRoche Diagnostics, Switzerland
41Menchinelli et al., 2021Italy594196Lumipulse® SARS-CoV-2 Ag kitFujirebio Inc., JapanSeegene Allplex® 2019 n-CoV AssaySeegene Inc., South Korea
42Merino-Amador et al., 2020Spain958361Abbott Diagnostic GmbH, Jena, GermanyAbbott Diagnostic GmbH, GermanyNot availableNot available
43Möckel et al., 2021Spain473115Roche SARS-CoV-2 Rapid Antigen TestRoche Diagnostics, SwitzerlandRoche cobas® SARS-CoV-2 AssayRoche Diagnostics, Switzerland
44Nalumansi et al., 2020Uganda26294STANDARD QTM COVID-19 Ag TestSD Biosensor, South KoreaNot availableNot available
45Ngo Nsoga et al., 2021Switzerland402169Abbott Diagnostic GmbH, Jena, GermanyAbbott Diagnostic GmbH, GermanyRoche cobas® SARS-CoV-2 AssayRoche Diagnostics, Switzerland
46Okoye et al., 2021United States2,63846BinaxNOWTM COVID-19 Ag Card test kitAbbott Diagnostics, Inc., United StatesTaqPath COVID-19 Multiplex KitThermo Fisher Scientific, United States
47aOsterman et al., 2021Germany445192STANDARD FTM COVID-19 Ag FIASD Biosensor, South KoreaRealAccurate® Quadruplex SARS CoV-2 PCR KitPathoFinder®, Netherlands
47b259Roche SARS-CoV-2 Rapid Antigen TestRoche Diagnostics, SwitzerlandRealAccurate® Quadruplex SARS CoV-2 PCR KitPathoFinder®, Netherlands
48Pekosz et al., 2021aUnited States25138BD VeritorTM SARS-CoV-2 Rapid Antigen testBecton, Dickinson and Company, United StatesLyra® RT-PCR AssayQuidel Corporation, United States
49aPeto, 2021United Kingdom940198Innova SARS-CoV-2 Antigen Rapid TestLotus Global Company, United KingdomNot availableNot available
49b100Abbott Diagnostic GmbH, Jena, GermanyAbbott Diagnostic GmbH, GermanyNot availableNot available
50 (sx/asx)Pilarowski et al., 2020aUnited States878131BinaxNOWTM COVID-19 Ag Card test kitAbbott Diagnostics Scarborough, Inc., United StatesNot availableNot available
51 (sx/asx)Pilarowski et al., 2020bUnited States3,302134BinaxNOWTM COVID-19 Ag Card test kitAbbott Diagnostics Scarborough, Inc., United StatesRenegade XPTMRenegadeBio, United States
52Pollock et al., 2021bUnited States226139S-PLEX® SARS-CoV-2 AssayMeso Scale Discovery, United StatesNot availableNot available
53 (sx/asx)Pollock et al., 2021aUnited States2,308295BinaxNOWTM COVID-19 Ag Card test kitAbbott Diagnostics Scarborough, Inc., United StatesCRSP SARS-CoV-2 RT-PCRHarvard University, United States
54Porte et al., 2020Chile12783BIOEASYTM 2019-nCoV Ag Rapid TestBIOEASY Technology, ChinaGenesig® Real-Time PCR assayPrimerdesign Ltd., United Kingdom
55 (sx/asx)Pray et al., 2021United States1,09859Quidel Sofia® SARS FIAQuidel, San Diego, CAMultiple tests usedMultiple manufacturers used
56 (sx/asx)Prince-Guerra et al., 2021United States3,419226BinaxNOWTM COVID-19 Ag Card test kitAbbott Diagnostics, Inc., United StatesMultiple tests usedMultiple manufacturers used
57Rastawicki et al., 2021Poland16738PCL COVID−19 Ag rapid immunoassayPLC, South KoreaMultiple tests usedMultiple manufacturers used
58aSchwob et al., 2020Switzerland928113STANDARD QTM COVID-19 Ag TestSD Biosensor, South KoreaNot availableNot available
58b123Abbott Diagnostic GmbH, Jena, GermanyAbbott Diagnostic GmbH, GermanyNot availableNot available
58c139COVID-VIRO®AAZ, FranceNot availableNot available
59 (sx/asx)Scohy et al., 2020Belgium14893COVID-19 Ag Respi-StripCoris BioConcept, BelgiumGenesig® Real-Time PCR assayPrimerdesign Ltd., United Kingdom
60Stokes et al., 2021Canada145140Abbott Diagnostic GmbH, Jena, GermanyAbbott Diagnostic GmbH, GermanyNot availableNot available
61Strömer et al., 2020Germany134126NADAL® COVID-19 Ag TestNal von Minden GmbH, GermanyNot availableNot available
62 (sx/asx)Takeuchi et al., 2021Japan77174Quick NaviTM-COVID 19 Ag Rapid TestOtsuka Pharmaceutical Co., Ltd., JapanNot availableNot available
63Toptan et al., 2020Germany6761RIDA® QUICK SARS-CoV-2 Antigen testR-Biopharm, Darmstadt, GermanyRoche cobas® SARS-CoV-2 AssayRoche Diagnostics, Switzerland
64Torres et al., 2021Spain63480Abbott Diagnostic GmbH, Jena, GermanyAbbott Diagnostic GmbH, GermanyTaqPath COVID-19 Multiplex KitThermo Fisher Scientific, United States
65 (sx/asx)Turcato et al., 2020Italy3,410227STANDARD QTM COVID-19 Ag TestSD Biosensor, South KoreaNot availableNot available
66Van der Moeren et al., 2020Netherlands352125BD VeritorTM SARS−CoV−2 Rapid Antigen testBecton, Dickinson and Company, United StatesRoche cobas® SARS-CoV-2 AssayRoche Diagnostics, Switzerland
67Villaverde et al., 2021Spain1,62079Abbott Diagnostic GmbH, Jena, GermanyAbbott Diagnostic GmbH, GermanyNot availableNot available
68aWeitzel et al., 2020Chile11181Biocredit COVID-19 Antigen TestRapiGen Inc., South KoreaGenesig® Real-Time PCR assayPrimerdesign Ltd., United Kingdom
68b80Huaketai New CoronavirusSavant Biotechnology Co., Ltd., ChinaGenesig® Real-Time PCR assayPrimerdesign Ltd., United Kingdom
68c82BIOEASY 2019-nCoV Ag Rapid TestBIOEASYTM Technology, ChinaGenesig® Real-Time PCR assayPrimerdesign Ltd., United Kingdom
69Yamamoto et al., 2021Japan608130In-house assayNot applicableNot availableNot available
70Young et al., 2020bUnited States22632BD VeritorTM SARS−CoV−2 Rapid Antigen testBecton, Dickinson and Company, United StatesLyra® RT-PCR AssayQuidel Corporation, United States
71United States460120BinaxNOWTM COVID-19 Ag Card test kitAbbott Diagnostics, Inc., United StatesRoche cobas® SARS-CoV-2 AssayRoche Diagnostics, Switzerland
72United States5327BinaxNOWTM COVID-19 Ag Card test kitAbbott Diagnostics, Inc., United StatesRoche cobas® SARS-CoV-2 AssayRoche Diagnostics, Switzerland
73United States12646CareStartTM COVID-19 Rapid TestAccess Bio, Inc., United StatesNot availableNot available
74Ellume Limited, 2020United States19840Ellume COVID-19 Home TestEllume Limited, United StatesNot availableNot available
75Luminostics Inc, 2020United States16635Clip COVID-Rapid Antigen TestLuminostics, Inc., United StatesNot availableNot available
76LumiraDx UK Ltd, 2020United Kingdom25786LumiraDxTM SARS-CoV-2 Ag TestLumiraDx, United KingdomRoche cobas® SARS-CoV-2 AssayRoche Diagnostics, Switzerland
77Quidel Corporation, 2020aUnited States15661QuickVue® SARS Antigen TestQuidel Corporation, United StatesNot availableNot available
78United States7239SampinuteTM COVID-19 Antigen MIACelltrion, United StatesNot availableNot available
79Quidel Corporation, 2020bUnited States20933Quidel Sofia® SARS FIAQuidel, United StatesLyra® RT-PCR AssayQuidel Corporation, United States
80Quidel Corporation, 2020cUnited States16545Quidel Sofia® SARS FIAQuidel, United StatesLyra® RT-PCR AssayQuidel Corporation, United States
81United States22632BD VeritorTM SARS−CoV−2 Rapid Antigen testBecton, Dickinson and Company, United StatesLyraTM RT-PCR AssayQuidel Corporation, United States
82EU25138BD VeritorTM SARS−CoV−2 Rapid Antigen testBecton, Dickinson and Company, United StatesLyra® RT-PCR AssayQuidel Corporation, United States
83United States11561BD VeritorTM SARS−CoV−2 Rapid Antigen testBecton, Dickinson and Company, United StatesLyra® RT-PCR AssayQuidel Corporation, United States

Information characterizing data sources involving SARS-CoV-2 antigen testing for analyses described in this report.

sx/ask, symptomatic/asymptomatic; SARS-CoV-2, severe acute respiratory syndrome coronavirus-2.

EU, European Union; IFU, manufacturer instructions for use; RFID, reference ID; RT-PCR, reverse transcription polymerase chain reaction.

aPekosz 2021 was only used as a data source for sensitivity analysis with Ct score stratification and for sensitivity analysis using cell culture as a reference.

bYoung 2020 was only used as a data source for sensitivity analysis for Ct score stratification.

A modified Newcastle–Ottawa Scale was used to rate biases of detection, performance, and participant selection (spectrum bias; Figure 3). The majority of studies were associated with low or moderate bias of detection (89.1%; 74/83), bias of performance (85.5%; 71/83), and spectrum bias (87.9%; 73/83). All included articles/sources had acceptable reference standards (that was an inclusion criterion), appropriate delay between index and reference testing, and no incorporation bias between the index and reference tests. The two most common weaknesses associated with study design for the included articles/sources were improper blinding and spectrum bias associated with participant enrollment (Lijmer et al., 1999). Across the six primary factors (viral load, symptomatic vs. asymptomatic, DSO, anatomical collection site, storage condition, and analytical sensitivity of the reference RT-qPCR assay) analyzed here, the quality of evidence was largely a mixture of high and moderate (Table 2).

FIGURE 3

TABLE 2

Overall quality of evidence for outcomesa (modified GRADE; Schunemann et al., 2013).

GRADE, Grading of Recommendations, Assessment, Development and Evaluation; Sx, symptomatic; Asx, asymptomatic; DSO, days from symptom onset.

aEach independent variable (e.g., Viral Load Stratification), was rated according to seven quality domains, with an overall quality rating in the last column. The overall quality rating was established based on the overall number of green (indicating high quality), yellow (indicating moderate quality), and red (indicating low quality) domains; blue shading indicates that the quality rating for that domain was unclear. For example, low Publication Bias and high Consistency are both rated as high quality, whereas a low Magnitude of Effect resulted in a low quality rating. Please see the Methods and Materials section for further description of the overall quality ranking.

bCounfounder effect characterizes the degree to which all plausible confounders would tend to increase confidence in the estimated effect.

Eighty-three percent (112/135) and 16.3% (22/135) of the data sets provided data from COVID-19 symptomatic and asymptomatic individuals, respectively. The index test sensitivity point estimate (with 95% CI) for the symptomatic group [80.1% (95% CI: 76.0, 83.7); reference positive n = 9,351] was significantly greater (p-value < 0.001) than that for index test sensitivity for the asymptomatic group [54.8% (95% CI: 48.6, 60.8); reference positive n = 1,723]. Of the 112 symptomatic data sets, 37.5% (42) included participants that were ≤7 DSO, and 25.9% (29) included individuals that were a mix of ≤7 DSO and >7 DSO; 36.6% (41) had a DSO status that was unknown. A significant difference (p-value = 0.001) was observed when studies reporting on symptomatic individuals were subgrouped by DSO; a sensitivity point estimate of 86.2% (95% CI: 81.8, 89.7) for the ≤7 DSO subgroup (reference positive n = 3,480) compared to 70.8% (95% CI: 60.7, 79.2) for the group including both ≤7 DSO and >7 DSO (reference positive n = 2,649; Figure 4 and Table 3).

FIGURE 4

TABLE 3

Variable categoryVariable groupNo. data setsTotal reference (+)Sensitivity (%)95% CIUnivariateaMultivariate
RT-qPCR Ct value≥105 cpm181,27893.8[87.1, 97.1]p < 0.001n/a
<105cpm1878128.6[16.2, 45.3]
Ct value ≤ 251689796.4[94.3, 97.7]p < 0.001n/a
Ct value > 251667344.9[33.0, 57.4]
Ct value ≤ 30372,53689.5[85.3, 92.5]p < 0.001n/a
Ct value > 303767918.7[12.9, 26.3]
Symptom statusSymptomatic959,35180.1[76.0, 83.7]p < 0.001p < 0.001
Asymptomatic231,72354.8[48.6, 60.8]
Missing information152,18665.3[56.4, 73.3]
≤7 DSO423,48086.2[81.8, 89.7]
≤7 DSO + > 7 DSO292,64970.8[60.7, 79.2]
Anatomical site (ref.)Nasal swab251,65482.7[74.7, 88.5]p = 0.037p = 0.023
NPS9710,60773.1[68.5, 77.2]
Missing1199971.6[55.7, 83.6]
Specimens storage (index)Fresh1019,66675.3[70.8, 79.3]p = 0.375
Frozen233,30770.9[61.0, 79.1]
Missing928781.5[69.3, 89.5]
Analytical sensitivity (Ref.)High (≤500 cpm)534,53174.2[66.9, 80.4]p = 0.650
Low (>500 cpm)222,58276.8[67.2, 84.2]
Missing586,14775.0[69.8, 79.5]
Study spectrum biasHigh/Moderate525,52481.4[75.5, 86.1]p = 0.004p = 0.757
Low815,87170.4[65.4, 74.9]
All sources combinedn/a13313,26075.0[71.0, 78.0]

Diagnostic performance (sensitivity) for antigen testing, with RT-qPCR as reference, stratified by different population and experimental factors.

CI, confidence interval; DSO, days from symptom onset; Ct, cycle threshold; cpm, genomic copies/ml; NPS, nasopharyngeal swab; and RT-qPCR, quantitative reverse transcription polymerase chain reaction.

aQ-test p-value for heterogeneity among subgroups calculated from random-effects meta-analysis.

Eighteen data sets reported true positives and false negatives by viral load in the specimen; 37 and 16 data sets reported values by a Ct value of 30 and 25, respectively, for the RT-qPCR (reference) assay. When data were stratified by ≥1 × 105 cpm (n = 1,278 reference positive results) vs. <1 × 105 cpm (n = 781 reference positive results), a significant difference was observed (p < 0.001) between the sensitivity point estimates [93.8% (95% CI: 87.1, 97.1) and 28.6% (95% CI: 16.2, 45.3), respectively]. Similar findings were associated with studies that were stratified by a Ct value of ≤30 (n = 2,536 reference positive results) and >30 (n = 679 reference positive results) [89.5% (95% CI: 85.3, 92.5) and 18.7% (95% CI: 12.9, 26.3), respectively] and those that were stratified by a Ct value of ≤25 (n = 897 reference positive results) and >25 (n = 673 reference positive results) [96.4% (95% CI: 94.3, 97.7) and 44.9% (95% CI: 33.0, 57.4), respectively]. Within a given viral load category, there were no statistical differences between studies performed with symptomatic subjects vs. studies performed with asymptomatic subjects; this was true regardless of the exact definition of viral load category: Ct of 25, Ct of 30, or cpm of 105 (Figure 5 and Table 3).

FIGURE 5

True positives and false negatives by anatomic collection site were obtained from 97 data sets that included reference nasopharyngeal specimens and from 25 data sets that included nasal reference specimens. Antigen testing was usually paired from the same specimen type, only six data sets being non-paired (antigen nasal, reference nasopharyngeal) specimens. When analysis was performed on data stratified by anatomic collection site of the reference specimen, antigen test sensitivity was higher with a nasal specimen [82.7% (95% CI: 74.7, 88.5, p = 0.037); reference positive n = 1,654] compared to a nasopharyngeal specimen [73.1% (95% CI: 68.5, 77.2); reference positive n = 10,607] (Table 3).

Storage condition of the collected specimens was also analyzed as one factor that could affect antigen test sensitivity. True positives and false negatives by test storage condition of the specimen that underwent antigen testing were obtained from 133 data sets. When analysis was focused on storage condition for index testing, antigen test sensitivity was 75.3% (95% CI: 70.8, 79.3; reference positive n = 9,666) for fresh specimens and 70.9% (95% CI: 61.0, 79.1; reference positive n = 3,307) for frozen specimens. This observed difference was not, however, statistically significant (p = 0.375; Table 3).

Analytical sensitivity of the reference method (RT-qPCR) was determined using the manufacturer’s IFU when it was identified in the source documents and used to stratify true-positive and false-negative results associated with SARS-CoV-2 antigen testing. The LOD threshold for low and high analytical sensitivity was 500 cpm, which was the median (mean = 582) LOD value for the analytical sensitivity from all of the reference methods included in this subanalysis. Sensitivity values for antigen testing when stratified by high (reference positive n = 4,468) and low (reference positive n = 2,645) analytically sensitive reference methods were similar: 74.2% (95% CI: 66.9, 80.4) and 76.8% (95%CI: 67.2, 84.2), respectively (Table 3).

Manufacturer (Supplementary Table 1) and study spectrum bias were also significant factors in subgroup meta-analyses; higher sensitivity was reported in studies with large/moderate spectrum bias (Table 3). A mixed-effects meta-regression model with moderators including symptom status, anatomical collection site, study selection/spectrum bias, and manufacturer was fit to the studies. All factors remained significant in the multivariate analysis, except study spectrum bias (multivariate p = 0.757). The moderators accounted for 72% of study heterogeneity (model R2 = 0.722). Visual inspection of unadjusted and multivariate-adjusted funnel plots for effect estimates from individual sources against study size was performed (Figure 3). The funnel plot asymmetry revealed possible reporting/publication bias reflecting fewer studies than expected that could be characterized by a small group number and a low sensitivity estimate for the index. Overall, study heterogeneity could largely be accounted for by the independent variables identified through subgroup analysis in this study.

Culture as the Reference

Sensitivity for SARS-CoV-2 antigen and RT-qPCR assays was determined as compared with SARS-CoV-2 viral culture as the reference method. There were five data sets that contained RT-qPCR (reference positive n = 154) and antigen test (reference positive n = 167) results. The overall sensitivity for RT-qPCR was 99.0% (95% CI: 96.0, 100) and for antigen testing was 90.0% (95% CI: 84.0, 94.0; Figure 6).

FIGURE 6

Specificity

Raw data for false-positive and true-negative rates were extracted from 63 of 81 of the included studies; the overall specificity across the included studies was 99.4% (95% CI: 99.3, 99.4) for antigen testing compared to RT-qPCR as the reference.

Discussion

The positive percent agreement point estimate (sensitivity) for antigen testing, spanning the entire 135 data sets included here, was 75.0% (95% CI: 71.0, 79.0). We found that factors including specimen viral load, symptom presence, DSO, anatomical collection site, and the storage conditions for specimen collection could all affect the measured performance of SARS-CoV-2 antigen tests (Supplementary Table 1 and Supplementary Figure 1). In addition, our meta-analysis revealed that antigen test sensitivity [96.0% (95% CI: 90.0, 99.0)] was highest in SARS-CoV-2-positive individuals with an increased likelihood of being infectious at the time of testing (e.g., culture positive; Pekosz et al., 2021). Although specificity data were not extracted for every study included in this meta-analysis, SARS-CoV-2 antigen testing had high specificity as published previously (). Experimental factors such as anatomical collection site, specimen storage conditions, analytical sensitivity of reference, and composition of the study population with respect to symptomology all varied across the field of studies included here.

This meta-analysis adds to the conclusions of others that viral load is clearly the most important factor that influences sensitivity for SARS-CoV-2 antigen testing. Two related meta-analyses have been published to date. The first by Dinnes et al. (2020) had the following key differences: (1) Dinnes et al. (2020) utilized numerous categories of point-of-care tests beyond antigen-based testing; (2) Dinnes et al. (2020) included five articles for antigen testing in their work; and (3) Dinnes et al. (2020) did not stratify the meta-analysis results for antigen testing by study design/viral load as is performed in this work. The second by had the following key differences: (1) focused on commercial rapid antigen tests; (2) only included 48 articles for antigen testing in their work; and (3) did not stratify the meta-analysis results for antigen test performance by study design characteristics as is performed in this work.

Test sensitivity was stratified by RT-qPCR Ct value (using both 25 cycles and 30 cycles as the cutoff); an inverse relationship was shown between Ct value and SARS-CoV-2 antigen test sensitivity. Both the ≤25 Ct group and the ≤30 Ct group had significantly higher sensitivities than their >25 Ct and >30 Ct counterparts, respectively, regardless of subjects’ symptom status. These results are consistent with those from previous studies (COVID-19 Scientific Advisory Group Rapid Evidence Report, 2020; Dinnes et al., 2020; ). However, Ct value has been shown by different groups to have a low correlation between different RT-qPCR assays and platforms (Ransom et al., 2020; Rhoads et al., 2020). RT-qPCR assays have different analytical sensitivities; a universal Ct value reference has not been established that can be used to define the optimal sensitivity/specificity characteristics for antigen testing. In addition to stratification by Ct value, analysis was also performed for SARS-CoV-2 antigen testing sensitivity by absolute viral load (using 1 × 105 as the cutoff). When data were analyzed using this strategy, similar results were observed as for stratification by Ct value. The viral load threshold utilized here was determined by a consensus value that appeared with regular frequency from the source articles and represented a viral threshold that consistently delineated a zone across which the false-positive rate increased for most antigen tests. It is generally accepted that viral loads of less than 1 × 105 cpm correlate with non-culture-positive levels. However, whether 1 × 105 cpm is the most accurate threshold by which to measure antigen test performance is still a topic for debate. Some studies suggest that viral loads closer to 1 × 106 cpm might be a more appropriate threshold, which would act to minimize false-positive rates (; Larremore et al., 2020; La Scola et al., 2020; Quicke et al., 2020; van Kampen et al., 2020; Wolfel et al., 2020).

Several factors identified here that affect SARS-CoV-2 antigen test performance have been identified in previous studies to affect specimen viral load. For example, a significant difference in sensitivity for detection was noted here between symptomatic and asymptomatic individuals. However, stratification in both symptomatic and asymptomatic specimen groups by high viral load has a similar effect of increasing test sensitivity. Our data show that 84% of SARS-CoV-2-positive specimens from symptomatic individuals corresponded to a high viral load, whereas only 56% of SARS-CoV-2-positive specimens from asymptomatic individuals qualified as high viral load in this analysis. This bias may be due to the difficulty of estimating the timing of peak viral load in asymptomatic individuals when attempting to compare the natural history of viral load trajectory in symptomatic vs. asymptomatic individuals (Smith et al., 2021). Nevertheless, the presence of symptoms probably overlaps with a higher specimen viral load, which subsequently affects the antigen test sensitivity. Anatomical collection type of the index and/or reference test method can affect the measured sensitivity estimates of antigen testing during a clinical trial, also through a mechanism that involves increased/decreased viral load on the specimen swab. Evidence suggests that viral loads may be higher with nasopharyngeal than with nasal collection (Pinninti et al., 2020). This difference may explain why measured antigen assay performance appears to be higher in studies that use a nasal RT-qPCR reference method.

Another factor identified here as potentially influencing measured antigen assay sensitivity was specimen storage, particularly with regard to the use of fresh vs. frozen (i.e., “banked”) specimens. It is likely that protein antigen may, as the result of freeze/thawing, experience some degree of structural damage potentially leading to loss of epitope availability or a reduction in the affinity of epitope/paratope binding. Ninety-six data sets involved fresh specimens for antigen testing, and 23 data sets included freeze/thawed specimens for antigen testing. Although no statistically significant difference was detected between sensitivities for antigen test conducted on fresh vs. frozen specimens, possibly due to the low data set group number in the frozen antigen group, a trend toward lower sensitivity was observed for tests performed on frozen specimens [75.3% (95% CI: 70.8, 79.3) for fresh vs. 70.9% (95% CI: 61.0, 79.1) for frozen]. In contrast, no similar trend was observed for specimen storage condition related to RT-qPCR testing [75.4% (95% CI: 70.6, 79.6) for fresh vs. 77.7% (95% CI: 69.3, 84.3) for frozen]. Additional results from in-house (i.e., a BD-IDS laboratory) testing with two different EUA authorized antigen assays demonstrate reduced immunoassay band intensity following freeze–thaw cycles, thus further supporting the findings from the meta-analysis that a freeze–thaw cycle could reduce analytical sensitivity for SARS-CoV-2 antigen testing (Supplementary Figure 2).

The analytical sensitivity associated with the reference RT-qPCR assay was also investigated here as a possible variable that could affect the false-negative rate of SARS-CoV-2 antigen testing. We hypothesized that relatively high analytical sensitivity for the reference RT-qPCR assay would impose a detection bias and result in decreased clinical sensitivity due to increased false negatives occurring near the RT-qPCR LOD. However, stratification by reference analytical sensitivity resulted in no difference in SARS-CoV-2 antigen test clinical sensitivity. It is likely that the analytical sensitivity of RT-qPCR, regardless of the manufacturer, is high enough that even relatively low sensitivity RT-PCR assays are still well below the corresponding LOD for antigen testing. On the other hand, some manufacturers evaluate antigen test performance in a manner that involves sensitivity above and below a set Ct value. It is possible that analysis involving stratification by RT-qPCR analytical sensitivity could reveal differences in antigen test performance if all antigen test performances were determined in a similar manner that involves predetermined high/low viral load categories.

Several population- and study design-specific factors were identified to be associated with higher measured assay sensitivity likely due to the association with higher viral loads. This meta-analysis demonstrates that these factors exist in various combinations across studies in an inconsistent way, thus making comparisons of assay performance across these studies impossible. The lack of consistency across study designs makes it very difficult to compare point estimates between antigen tests to judge their relative clinical efficacy. The introduction of different forms of bias into the study design, and during study conduct, could explain why discrepancies have been noted, for example, between sensitivity values listed in manufacturers’ IFUs and those obtained during independent evaluation of the same antigen test. Ultimately, direct comparison between antigen tests should be the most reliable approach for obtaining relative performance characteristics with any certainty. Here, we stratified SARS-CoV-2 antigen test sensitivity by spectrum bias associated with each of the data sources. We found that those studies rated with higher spectrum bias also had higher antigen test sensitivities. In addition, the funnel plot analysis that was performed for this meta-analysis shows obvious publication bias, which implicated a lack of publication of studies with low study group number and low sensitivity.

Clinical trials and studies involving diagnostics are vulnerable to the introduction of bias, which can alter test performance results and obstruct an accurate interpretation of clinical efficacy or safety. For example, antigen testing appears to have a higher sensitivity when compared to SARS-CoV-2 viral culture as the reference than when compared to RT-PCR. However, these two reference methods measure different targets: RNA only vs. infectious virus. Therefore, their use as a reference method should be intended to answer different scientific questions rather than artificially inflating apparent sensitivity point estimates. If the intent of a diagnostic test is determining increased risk of infectiousness through the presence of replicating virus, the high analytical sensitivity of RT-qPCR, which cannot distinguish RNA fragments from infectious virus, renders this diagnostic approach vulnerable to the generation of false-positive results, particularly at later time points following symptom onset. At time points beyond 1 week from symptom onset, a positive RT-qPCR result more likely indicates that an individual has been infected but is no longer contagious and cannot spread infectious virus. This is especially true for those with a SARS-CoV-2-negative cell culture result. Previous reports have shown that performance values for rapid antigen tests and SARS-CoV-2 viral culture exhibit better agreement than do results from RT-qPCR compared to viral culture in symptomatic individuals, thus making it a good test to identify individuals who are likely to be shedding infectious virus and therefore have potential to transmit SARS-CoV-2 (Pekosz et al., 2021). With this current analysis, we further show that antigen testing is also able to reliably identify asymptomatic individuals with viral load indicative of shedding infectious virus (1 × 105 cpm and/or a Ct score ≤30).

This work focused on factors that can affect antigen test sensitivity for detection of SARS-CoV-2. RT-qPCR testing and other forms of testing (such as molecular point-of-care assays or serological testing) have been characterized and described as diagnostic approaches for SARS-CoV-2 elsewhere (). Several assay characteristics, including time to result (Peeling et al., 2021), analytical sensitivity (Mak et al., 2020), cost per test (Neilan et al., 2020; Kepczynski et al., 2021; Love et al., 2021; Jakobsen et al., 2021b), infrastructure requirements for testing (), and volume of testing (), need to be considered before determining the most appropriate testing strategy. As the priorities for specific test characteristics differ between testing sites, so does the overall value of a given diagnostic test.

Limitations

This study has some limitations. First, it was difficult to obtain reliable information across the sources, in a consistent manner, about disease severity in order to perform a meta-analysis on this aspect of COVID-19 diagnostics. Additionally, the studies included in this meta-analysis did not contain sufficient information to explore the potential effect of factors previously demonstrated to be associated with higher viral loads such as disease severity and community prevalence.

Conclusion

In addition to viral load, several factors including symptom status, anatomical collection site, and spectrum bias all influenced the sensitivity for SARS-CoV-2 detection by antigen-based testing. This heterogeneity of factors found to influence measured assay sensitivity, across studies, precludes comparison of assay sensitivity from one study to another. Future consideration regarding standardization of these factors for antigen assay performance studies is warranted in order to aid in results interpretation and relative performance assessment.

Author Disclaimer

The views expressed in this article are those of the authors and do not necessarily represent the views of the National Institute of Biomedical Imaging and Bioengineering; the National Heart, Lung, and Blood Institute; the National Institutes of Health; or the United States Department of Health and Human Services.

Publisher’s Note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Statements

Data availability statement

The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding author/s.

Author contributions

All authors contributed to the interpretation of the data, critically revised the manuscript for important intellectual content, approved the final version to be published, and agree to be accountable for all aspects of the work.

Funding

This study was funded by Becton, Dickinson and Company, BD Life Sciences–Integrated Diagnostic Solutions. Non-BD employee authors received research funds to support their work for this study. YCM received salary support from the National Institutes of Health grant funding (U5411090366, U54EB007958-12, and 3U54HL143541-02S2).

Acknowledgments

We thank Karen Eckert (Becton, Dickinson and Company, BD Life Sciences–Diagnostic Systems) for her input on the content of this manuscript and editorial assistance.

Conflict of interest

VP, DG, Y-CL, DM, LC, JM, JA, and CC are employees of Becton, Dickinson and Company. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Supplementary material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fmicb.2021.714242/full#supplementary-material

References

  • 1

    Abbott Diagnostics Scarborough Inc (2020a). BinaxNOWTM COVID-19 Ag CARD HOME TEST[package insert, EUA].Scarborough, ME: Abbott Diagnostics Scarborough Inc.

  • 2

    Abbott Diagnostics Scarborough Inc (2020b). BinaxNOWTM COVID-19 Ag CARD [package insert, EUA].Scarborough, ME: Abbott Diagnostics Scarborough Inc.

  • 3

    AbdelrazikA. M.ElshafieS. M.AbdelazizH. M. (2020). Potential use of antigen-based rapid test for SARS-CoV-2 in respiratory specimens in low-resource settings in egypt for symptomatic patients and high-risk contacts.Lab. Med.52e46e49.

  • 4

    AbdulrahmanA.MustafaF.AlawadhiA. I.AlansariQ.AlalawiB.AlqahtaniM. (2020). Comparison of SARS-COV-2 nasal antigen test to nasopharyngeal RT-PCR in mildly symptomatic patients.medRxiv [Preprint]10.1101/2020.11.10.20228973

  • 5

    Access Bio (2020). CareStartTM COVID-19 Atigen-Rapid Diagnostic Test for the Detection of SARS-CoV-2 Antigen [package insert, EUA].Somerset, NJ: Access Bio, Inc.

  • 6

    AccorsiE. K.QiuX.RumplerE.Kennedy-ShafferL.KahnR.JoshiK.et al (2021). How to detect and reduce potential sources of biases in studies of SARS-CoV-2 and COVID-19.Eur. J. Epidemiol.36179196. 10.1007/s10654-021-00727-7

  • 7

    AlbertE.TorresI.BuenoF.HuntleyD.MollaE.Fernández-FuentesM.et al (2020). Field evaluation of a rapid antigen test (PanbioTM COVID-19 Ag Rapid Test Device) for COVID-19 diagnosis in primary healthcare centres.Clin. Microbiol. Infect.27472.e7472.e10.

  • 8

    AlemanyA.BaróB.OuchiD.RodóP.UbalsM.Corbacho-MonnéM.et al (2021). Analytical and clinical performance of the panbio COVID-19 antigen-detecting rapid diagnostic test.J. Infect.82186230. 10.1016/j.jinf.2020.12.033

  • 9

    AokiK.NagasawaT.IshiiY.YagiS.KashiwagiK.MiyazakiT.et al (2021). Evaluation of clinical utility of novel coronavirus antigen detection reagent, Espline§SARS-CoV-2.J. Infect. Chemother.27319322. 10.1016/j.jiac.2020.11.015

  • 10

    AokiK.NagasawaT.IshiiY.YagiS.OkumaS.KashiwagiK.et al (2020). Clinical validation of quantitative SARS-CoV-2 antigen assays to estimate SARS-CoV-2 viral loads in nasopharyngeal swabs.J. Infect. Chemother.27613616. 10.1016/j.jiac.2020.11.021

  • 11

    AugustinM.SchommersP.SuárezI.KoehlerP.GruellH.KleinF. (2020). Rapid response infrastructure for pandemic preparedness in a tertiary care hospital: lessons learned from the COVID-19 outbreak in Cologne, Germany, February to March 2020.Euro Surveill.25:2000531.

  • 12

    BalduzziS.RückerG.SchwarzerG. (2019). How to perform a meta-analysis with R: a practical tutorial.Evid. Based Ment. Health22153160. 10.1136/ebmental-2019-300117

  • 13

    BD (2020a). BD VeritorTM System for Rapid Detection of SARS-CoV-2 [package insert, EUA].Franklin Lakes, NJ: Becton, Dickinson and Company.

  • 14

    BD (2020b). BD VeritorTM System for Rapid Detection of SARS-CoV-2 [package insert, CE Mark].Franklin Lakes, NJ: Becton, Dickinson and Company.

  • 15

    BD (2020c). BD VeritorTM Triplex System for Rapid Detection of SARS-CoV-2 and Flu A/B [package insert, EUA].Franklin Lakes, NJ: Becton, Dickinson and Company.

  • 16

    BeckE. T.PaarW.FojutL.SerweJ.JahnkeR. R. (2021). Comparison of the Quidel Sofia SARS FIA test to the Hologic Aptima SARS-CoV-2 TMA test for diagnosis of COVID-19 in symptomatic outpatients.J. Clin. Microbiol.59:e2727-20.

  • 17

    BergerA.Ngo NsogaM. T.Perez-RodriguezF. J.AadY. A.Sattonnet-RocheP.Gayet-AgeronA. (2020). Diagnostic accuracy of two commercial SARS-CoV-2 Antigen-detecting rapid tests at the point of care in community-based testing centers.medRxiv [Preprint]10.1101/2020.11.20.20235341

  • 18

    BoothA.ClarkeM.GhersiD.MoherD.PetticrewM.StewartL. (2011). An international registry of systematic-review protocols.Lancet377108109. 10.1016/s0140-6736(10)60903-8

  • 19

    BrümmerL. E.KatzenschlagerS.GaeddertM.ErdmannC.SchmitzS.BotaM. (2021). The accuracy of novel antigen rapid diagnostics for SARS-CoV-2: a living systematic review and meta-analysis.PLoS Med.18:e1003735. 10.1371/journal.pmed.1003735

  • 20

    BulileteO.LorenteP.LeivaA.CarandellE.OliverA.RojoE.et al (2020). Evaluation of the PanbioTM rapid antigen test for SARS-CoV-2 in primary health care centers and test sites.medRxiv [Preprint]10.1101/2020.11.13.20231316

  • 21

    BustinS. A.NolanT. (2020). RT-qPCR testing of SARS-CoV-2: a primer.Int. J. Mol. Sci.21:3004. 10.3390/ijms21083004

  • 22

    CarlosW. G.Dela CruzC. S.CaoB.PasnickS.JamilS. (2020). Novel Wuhan (2019-nCoV) Coronavirus.Am. J. Respir. Crit. Care Med.20178.

  • 23

    CarterL. J.GarnerL. V.SmootJ. W.LiY.ZhouQ.SavesonC. J. (2020). Assay techniques and test development for COVID-19 diagnosis.ACS Cent. Sci.6591605. 10.1021/acscentsci.0c00501

  • 24

    Celltrion (2020). SampinuteTM COVID-19 Antigen MIA [package insert, EUA].Jersey City, NJ: Celltrion.

  • 25

    Centers for Disease Control (2020). Interim Guidance for Antigen Testing for SARS-CoV-2. Available Online at: https://www.cdc.gov/coronavirus/2019-nCoV/lab/guidelines-clinical-specimens.html(accessed May 24, 2021).

  • 26

    CeruttiF.BurdinoE.MiliaM. G.AlliceT.GregoriG.BruzzoneB.et al (2020). Urgent need of rapid tests for SARS CoV-2 antigen detection: evaluation of the SD-Biosensor antigen test for SARS-CoV-2.J. Clin. Virol.132:104654. 10.1016/j.jcv.2020.104654

  • 27

    ChaimayoC.KaewnaphanB.TanliengN.AthipanyasilpN.SirijatuphatR.ChayakulkeereeM.et al (2020). Rapid SARS-CoV-2 antigen detection assay in comparison with real-time RT-PCR assay for laboratory diagnosis of COVID-19 in Thailand.Virol. J.17:177.

  • 28

    ChangD.LinM.WeiL.XieL.ZhuG.Dela CruzC. S.et al (2020). Epidemiologic and clinical characteristics of novel coronavirus infections involving 13 patients outside Wuhan, China.JAMA32310921093. 10.1001/jama.2020.1623

  • 29

    CiottiM.MauriciM.PieriM.AndreoniM.BernardiniS. (2021). Performance of a rapid antigen test in the diagnosis of SARS-CoV-2 infection.J. Med. Virol.9329882991. 10.1002/jmv.26830

  • 30

    ColavitaF.VairoF.MeschiS.ValliB.LalleE.CastillettiC.et al (2020). COVID-19 antigen rapid test as screening strategy at the points-of-entry: experience in Lazio Region, Central Italy, August-October 2020.medRxiv [preprint]10.1101/2020.11.26.20232728

  • 31

    COVID-19 Scientific Advisory Group Rapid Evidence Report (2020). Available Online at: https://www.albertahealthservices.ca/assets/info/ppih/if-ppih-covid-19-sag-performance-and-feasibility-of-rapid-covid-19-tests-rapidreview.pdf(accessed May 24, 2021).

  • 32

    CourtellemontL.GuinardJ.GuillaumeC.GiachéS.RzepeckiV.SeveA.et al (2021). High performance of a novel antigen detection test on nasopharyngeal specimens for SARS-CoV-2 infection diagnosis: a prospective study.medRxiv [Preprint]10.1101/2020.10.28.20220657

  • 33

    DiaoB.WenK.ZhangJ.ChenJ.HanC.ChenY.et al (2020). Accuracy of a nucleocapsid protein antigen rapid test in the diagnosis of SARS-CoV-2 infection.Clin. Microbiol. Infect.27289.e1289.e4.

  • 34

    DinnesJ.DeeksJ. J.AdrianoA.BerhaneS.DavenportC.DittrichS.et al (2020). Rapid, point-of-care antigen and molecular-based tests for diagnosis of SARS-CoV-2 infection.Cochrane Database Syst. Rev.8:Cd013705.

  • 35

    DrainP. K.AmpajwalaM.ChappelC.GvozdenA. B.HoppersM.WangM.et al (2020). A rapid, high-sensitivity SARS-CoV-2 nucleocapsid immunoassay to aid diagnosis of acute COVID-19 at the point of care.medRxiv [preprint]10.1101/2020.12.11.20238410

  • 36

    DrevinekP.HurychJ.KepkaZ.BriksiA.KulichM.ZajacM.et al (2020). The sensitivity of SARS-CoV-2 antigen tests in the view of large-scale testing.medRxiv [preprint]10.1101/2020.11.23.20237198

  • 37

    Ellume Limited (2020). Ellume COVID-19 Home Test [package insert, EUA].Australia: Ellume Limited.

  • 38

    FavresseJ.GillotC.OliveiraM.CadrobbiJ.ElsenM.EucherC.et al (2021). Head-to-head comparison of rapid and automated antigen detection tests for the diagnosis of SARS-CoV-2 infection.J. Clin. Med.10:265. 10.3390/jcm10020265

  • 39

    FenollarF.BouamA.BalloucheM.FusterL.PrudentE.ColsonP.et al (2021). Evaluation of the Panbio COVID-19 rapid antigen detection test device for the screening of patients with COVID-19.J. Clin. Microbiol.59:e2589-20.

  • 40

    Food and Drug Administration (2011). Establishing the Performance Characteristics of In Vitro Diagnostic Devices for the Detection or Detection and Differentiation of Influenza Viruses - Guidance for Industry and FDA Staff. Available Online at: https://www.fda.gov/regulatory-information/search-fda-guidance-documents/establishing-performance-characteristics-vitro-diagnostic-devices-detection-or-detection-and(accessed May 24, 2021).

  • 41

    GatsonisC.PaliwalP. (2006). Meta-analysis of diagnostic and screening test accuracy evaluations: methodologic primer.AJR Am. J. Roentgenol.187271281. 10.2214/ajr.06.0226

  • 42

    GiriB.PandeyS.ShresthaR.PokharelK.LiglerF. S.NeupaneB. B. (2021). Review of analytical performance of COVID-19 detection methods.Anal. Bioanal. Chem.4133548. 10.1007/s00216-020-02889-x

  • 43

    GremmelsH.WinkelB. M. F.SchuurmanR.RosinghA.RigterN. A. M.RodriguezO.et al (2021). Real-life validation of the PanbioTM COVID-19 antigen rapid test (Abbott) in community-dwelling subjects with symptoms of potential SARS-CoV-2 infection.EClinicalMedicine31:100677. 10.1016/j.eclinm.2020.100677

  • 44

    GriffithG. J.MorrisT. T.TudballM. J.HerbertA.MancanoG.PikeL.et al (2020). Collider bias undermines our understanding of COVID-19 disease risk and severity.Nat. Commun.11:5749.

  • 45

    HeX.LauE. H. Y.WuP.DengX.WangJ.HaoX.et al (2020). Temporal dynamics in viral shedding and transmissibility of COVID-19.Nat. Med.26672675. 10.1038/s41591-020-0869-5

  • 46

    HirotsuY.MaejimaM.ShibusawaM.AmemiyaK.NagakuboY.HosakaK.et al (2021). Analysis of a persistent viral shedding patient infected with SARS-CoV-2 by RT-qPCR, FilmArray respiratory Panel v2.1, and antigen detection.J. Infect. Chemother.27406409. 10.1016/j.jiac.2020.10.026

  • 47

    HirotsuY.MaejimaM.ShibusawaM.NagakuboY.HosakaK.AmemiyaK.et al (2020). Comparison of automated SARS-CoV-2 antigen test for COVID-19 infection with quantitative RT-PCR using 313 nasopharyngeal swabs, including from seven serially followed patients.Int. J. Infect. Dis.99397402. 10.1016/j.ijid.2020.08.029

  • 48

    HoehlS.SchenkB.RudychO.GöttigS.FoppaI.KohmerN.et al (2020). At-home self-testing of teachers with a SARS-CoV-2 rapid antigen test to reduce potential transmissions in schools.medRxiv [preprint]10.1101/2020.12.04.20243410

  • 49

    HoustonH.Gupta-WrightA.Toke-BjolgerudE.Biggin-LammingJ.JohnL. (2021). Diagnostic accuracy and utility of SARS-CoV-2 antigen lateral flow assays in medical admissions with possible COVID-19.J. Hosp. Infect.110203205. 10.1016/j.jhin.2021.01.018

  • 50

    JääskeläinenA. E.AhavaM. J.JokelaP.SziroviczaL.PohjalaS.VapalahtiO.et al (2021). Evaluation of three rapid lateral flow antigen detection tests for the diagnosis of SARS-CoV-2 infection.J. Clin. Virol.137:104785. 10.1016/j.jcv.2021.104785

  • 51

    JakobsenK. K.JensenJ. S.TodsenT.LippertF.MartelC. J.-M.KlokkerM.et al (2021a). Detection of SARS-CoV-2 infection by rapid antigen test in comparison with RT-PCR in a public setting.medRxiv [preprint]10.1101/2021.01.22.21250042

  • 52

    JakobsenK. K.JensenJ. S.TodsenT.TolsgaardM. G.KirkbyN.LippertF.et al (2021b). Accuracy and cost description of rapid antigen test compared with reverse transcriptase-polymerase chain reaction for SARS-CoV-2 detection.Dan Med. J.68:A03210217.

  • 53

    JamesA. E.GulleyT.KothariA.HolderK.GarnerK.PatilN. (2021). Performance of the BinaxNOW COVID-19 Antigen Card test relative to the SARS-CoV-2 real-time reverse transcriptase polymerase chain reaction assay among symptomatic and asymptomatic healthcare employees.Infect. Control Hosp. Epidemiol.10.1017/ice.2021.20Online ahead of print.

  • 54

    KashiwagiK.IshiiY.AokiK.YagiS.MaedaT.MiyazakiT.et al (2020). Immunochromatographic test for the detection of SARS-CoV-2 in saliva.medRxiv [Preprint]10.1101/2020.05.20.20107631

  • 55

    KepczynskiC. M.GenigeskiJ. A.De RegnierD. P.JadhavE. D.SohnM.KlepserM. E. (2021). Performance of the BD Veritor system SARS-CoV-2 antigen test among asymptomatic collegiate athletes: a diagnostic accuracy study.Explor. Res. Clin. Soc. Pharmacy3100047100047. 10.1016/j.rcsop.2021.100047

  • 56

    KohmerN.ToptanT.PallasC.KaracaO.PfeifferA.WesthausS.et al (2021). The comparative clinical performance of four SARS-CoV-2 rapid antigen tests and their correlation to infectivity in vitro.J. Clin. Med.10:328. 10.3390/jcm10020328

  • 57

    KrügerL. J.GaeddertM.KöppelL.BrümmerL. E.GottschalkC.MirandaI. B.et al (2020). Evaluation of the accuracy, ease of use and limit of detection of novel, rapid, antigen-detecting point-of-care diagnostics for SARS-CoV-2.medRxiv [preprint]10.1101/2020.10.01.20203836

  • 58

    KrüttgenA.CornelissenC. G.DreherM.HornefM. W.ImöhlM.KleinesM. (2021). Comparison of the SARS-CoV-2 Rapid antigen test to the real star Sars-CoV-2 RT PCR kit.J. Virol. Methods288:114024.

  • 59

    La MarcaA.CapuzzoM.PagliaT.RoliL.TrentiT.NelsonS. M. (2020). Testing for SARS-CoV-2 (COVID-19): a systematic review and clinical guide to molecular and serological in-vitro diagnostic assays.Reprod. Biomed. Online41483499. 10.1016/j.rbmo.2020.06.001

  • 60

    La ScolaB.Le BideauM.AndreaniJ.HoangV. T.GrimaldierC.ColsonP.et al (2020). Viral RNA load as determined by cell culture as a management tool for discharge of SARS-CoV-2 patients from infectious disease wards.Eur. J. Clin. Microbiol. Infect. Dis.3910591061. 10.1007/s10096-020-03913-9

  • 61

    Lambert-NiclotS.CuffelA.Le PapeS.Vauloup-FellousC.Morand-JoubertL.Roque-AfonsoA. M.et al (2020). Evaluation of a rapid diagnostic assay for detection of SARS-CoV-2 antigen in nasopharyngeal swabs.J. Clin. Microbiol.58:e977-20.

  • 62

    LarremoreD. B.WilderB.LesterE.ShehataS.BurkeJ. M.HayJ. A.et al (2020). Test sensitivity is secondary to frequency and turnaround time for COVID-19 surveillance.medRxiv [preprint]10.1101/2020.06.22.20136309

  • 63

    LeeflangM. M. G. (2014). Systematic reviews and meta-analyses of diagnostic test accuracy.Clin. Microbiol. Infect.20105113. 10.1111/1469-0691.12474

  • 64

    LiQ.GuanX.WuP.WangX.ZhouL.TongY.et al (2020). Early transmission dynamics in wuhan, china, of novel coronavirus–infected pneumonia.N. England J. Med.38211991207.

  • 65

    LijmerJ. G.MolB. W.HeisterkampS.BonselG. J.PrinsM. H.Van Der MeulenJ. H. P.et al (1999). Empirical evidence of design-related bias in studies of diagnostic tests.JAMA28210611066. 10.1001/jama.282.11.1061

  • 66

    LinaresM.Pérez-TanoiraR.CarreroA.RomanykJ.Pérez-GarcíaF.Gómez-HerruzP.et al (2020). Panbio antigen rapid test is reliable to diagnose SARS-CoV-2 infection in the first 7 days after the onset of symptoms.J. Clin. Virol.133:104659. 10.1016/j.jcv.2020.104659

  • 67

    LindnerA. K.NikolaiO.KauschF.WintelM.HommesF.GertlerM.et al (2020). Head-to-head comparison of SARS-CoV-2 antigen-detecting rapid test with self-collected anterior nasal swab versus professional-collected nasopharyngeal swab.Eur. Respir. J.57:2003961. 10.1183/13993003.03961-2020

  • 68

    LindnerA. K.NikolaiO.RohardtC.KauschF.WintelM.GertlerM.et al (2021). SARS-CoV-2 patient self-testing with an antigen-detecting rapid test: a head-to-head comparison with professional testing.medRxiv [Preprint]10.1101/2021.01.06.20249009

  • 69

    LiottiF. M.MenchinelliG.LalleE.PalucciI.MarchettiS.ColavitaF.et al (2020). Performance of a novel diagnostic assay for rapid SARS-CoV-2 antigen detection in nasopharynx samples.Clin. Microbiol. Infect.27487488. 10.1016/j.cmi.2020.09.030

  • 70

    LiuD.WuF.CenY.YeL.ShiX.HuangY.et al (2021). Comparative research on nucleocapsid and spike glycoprotein as the rapid immunodetection targets of COVID-19 and establishment of immunoassay strips.Mol. Immunol.131612. 10.1016/j.molimm.2021.01.005

  • 71

    LoveJ.WimmerM. T.TothD. J. A.ChandranA.MakhijaD.CooperC. K.et al (2021). Comparison of antigen- and RT-PCR-based testing strategies for detection of Sars-Cov-2 in two high-exposure settings.medRxiv [Preprint]10.1101/2021.06.03.21258248

  • 72

    Luminostics Inc (2020). Clip COVID-Rapid Antigen Test [package insert, EUA].Milpitas, CA: Luminostics, Inc.

  • 73

    LumiraDx UK Ltd (2020). LumiraDxTMSARS-CoV-2Ag Test [package insert, EUA].UK: LumiraDx UK Ltd.

  • 74

    MakG. C. K.LauS. S. Y.WongK. K. Y.ChowN. L. S.LauC. S.LamE. T. K.et al (2021). Evaluation of rapid antigen detection kit from he WHO emergency use list for detecting SARS-CoV-2.J. Clin. Virol.134:104712. 10.1016/j.jcv.2020.104712

  • 75

    MakG. C.LauS. S.WongK. K.ChowN. L.LauC. S.LamE. T.et al (2020). Analytical sensitivity and clinical sensitivity of the three rapid antigen detection kits for detection of SARS-CoV-2 virus.J. Clin. Virol.133:104684.

  • 76

    MasiáM.Fernández-GonzálezM.SánchezM.CarvajalM.GarcíaJ. A.GonzaloN.et al (2020). Nasopharyngeal Panbio COVID-19 antigen performed at point-of-care has a high sensitivity in symptomatic and asymptomatic patients with higher risk for transmission and older age.medRxiv [Preprint]10.1101/2020.11.16.20230003

  • 77

    MenchinelliG.BordiL.LiottiF. M.PalucciI.CapobianchiM. R.SbernaG.et al (2021). Lumipulse G SARS-CoV-2 ag assay evaluation for SARS-CoV-2 antigen detection using 594 nasopharyngeal swab samples from different testing groups.medRxiv [Preprint]10.1101/2021.01.26.21250533

  • 78

    Merino-AmadorP.GuineaJ.Muñoz-GallegoI.González-DonapetryP.GalánJ.-C.AntonaN.et al (2020). Multicenter evaluation of the PanbioTM COVID-19 rapid antigen-detection test for the diagnosis of SARS-CoV-2 infection.medRxiv[Preprint]10.1101/2020.11.18.20230375

  • 79

    MinaM. J.ParkerR.LarremoreD. B. (2020). Rethinking Covid-19 test sensitivity — a strategy for containment.N. Engl. J. Med.383:e120. 10.1056/nejmp2025631

  • 80

    MöckelM.CormanV. M.StegemannM. S.HofmannJ.SteinA.JonesT. C.et al (2021). SARS-CoV-2 antigen rapid immunoassay for diagnosis of COVID-19 in the emergency department.Biomarkers26213220. 10.1080/1354750x.2021.1876769

  • 81

    NalumansiA.LutaloT.KayiwaJ.WateraC.BalinandiS.KiconcoJ.et al (2020). Field evaluation of the performance of a SARS-CoV-2 antigen rapid diagnostic test in Uganda using nasopharyngeal samples.Int. J. Infect. Dis.104282286. 10.1016/j.ijid.2020.10.073

  • 82

    NeilanA. M.LosinaE.BangsA. C.FlanaganC.PanellaC.EskibozkurtG. E.et al (2020). Clinical impact, costs, and cost-effectiveness of expanded SARS-CoV-2 testing in massachusetts.medRxiv [preprint]10.1101/2020.07.23.20160820

  • 83

    Ngo NsogaM.-T.KronigI.Perez RodriguezF. J.Sattonnet-RocheP.Da SilvaD.HelblingJ.et al (2021). Diagnostic accuracy of PanbioTM rapid antigen tests on oropharyngeal swabs for detection of SARS-CoV-2.medRxiv [preprint]10.1101/2021.01.30.21250314

  • 84

    OkoyeN. C.BarkerA. P.CurtisK.OrlandiR. R.SnavelyE. A.WrightC.et al (2021). Performance characteristics of BinaxNOW COVID-19 antigen card for screening asymptomatic individuals in a university setting.J. Clin. Microbiol.59:e3282-20.

  • 85

    OranD. P.TopolE. J. (2020). Prevalence of asymptomatic SARS-CoV-2 Infection.Ann. Intern. Med.173362367.

  • 86

    OstermanA.BaldaufH. M.EletrebyM.WettengelJ. M.AfridiS. Q.FuchsT.et al (2021). Evaluation of two rapid antigen tests to detect SARS-CoV-2 in a hospital setting.Med. Microbiol. Immunol.2106572. 10.1007/s00430-020-00698-8

  • 87

    PageM. J.MckenzieJ. E.BossuytP. M.BoutronI.HoffmannT. C.MulrowC. D.et al (2020). The PRISMA 2020 statement: an updated guideline for reporting systematic reviews.MetaArXiv [preprint]10.31222/osf.io/v7gm2

  • 88

    PeelingR. W.OlliaroP. L.BoerasD. I.FongwenN. (2021). Scaling up COVID-19 rapid antigen tests: promises and challenges.Lancet. Infect. Dis.21E290E295.

  • 89

    PekoszA.ParvuV.LiM.AndrewsJ. C.ManabeY. C.KodsiS.et al (2021). Antigen-based testing but not real-time polymerase chain reaction correlates with severe acute respiratory syndrome Coronavirus 2 viral culture.Clin. Infect. Dis.10.1093/cid/ciaa1706Online ahead of print.

  • 90

    PetoT. (2021). COVID-19: rapid antigen detection for SARS-CoV-2 by lateral flow assay: a national systematic evaluation for mass-testing.medRxiv [preprint]10.1101/2021.01.13.21249563

  • 91

    PilarowskiG.LebelP.SunshineS.LiuJ.CrawfordE.MarquezC.et al (2020a). Performance characteristics of a rapid SARS-CoV-2 antigen detection assay at a public plaza testing site in San Francisco.medRxiv [preprint]10.1101/2020.11.02.20223891

  • 92

    PilarowskiG.MarquezC.RubioL.PengJ.MartinezJ.BlackD.et al (2020b). Field performance and public health response using the BinaxNOW TM Rapid SARS-CoV-2 antigen detection assay during community-based testing.Clin. Infect. Dis.10.1093/cid/ciaa1890Online ahead of print.

  • 93

    PinnintiS.TrieuC.PatiS. K.LattingM.CooperJ.SelemeM. C.et al (2020). Comparing nasopharyngeal and midturbinate nasal swab testing for the identification of severe acute respiratory syndrome Coronavirus 2.Clin. Infect. Dis.7212531255. 10.1093/cid/ciaa882

  • 94

    PollockN. R.JacobsJ. R.TranK.CranstonA.SmithS.O’ KaneC.et al (2021a). Performance and implementation evaluation of the Abbott BinaxNOW rapid antigen test in a high-throughput drive-through community testing site in massachusetts.J. Clin. Microbiol.59:e83-21.

  • 95

    PollockN. R.SavageT. J.WardellH.LeeR. A.MathewA.StengelinM.et al (2021b). Correlation of SARS-CoV-2 nucleocapsid antigen and RNA concentrations in nasopharyngeal samples from children and adults using an ultrasensitive and quantitative antigen assay.J. Clin. Microbiol.59:e3077-20.

  • 96

    PorteL.LegarragaP.VollrathV.AguileraX.MunitaJ. M.AraosR.et al (2020). Evaluation of a novel antigen-based rapid detection test for the diagnosis of SARS-CoV-2 in respiratory samples.Int. J. Infect. Dis.99328333. 10.1016/j.ijid.2020.05.098

  • 97

    PrayI. W.FordL.ColeD.LeeC.BigouetteJ. P.AbediG. R.et al (2021). Performance of an antigen-based test for asymptomatic and symptomatic SARS-CoV-2 testing at two university campuses - Wisconsin. September-October 2020.MMWR Morb. Mortal. Wkly. Rep.6916421647.

  • 98

    Prince-GuerraJ. L.AlmendaresO.NolenL. D.GunnJ. K. L.DaleA. P.BuonoS. A.et al (2021). Evaluation of Abbott BinaxNOW rapid antigen test for SARS-CoV-2 infection at two community-based testing sites - pima county, Arizona, November 3-17, 2020.MMWR Morb. Mortal. Wkly. Rep.70100105. 10.15585/mmwr.mm7003e3

  • 99

    QuickeK.GallichoteE.SextonN.YoungM.JanichA.GahmG.et al (2020). Longitudinal surveillance for SARS-CoV-2 RNA among asymptomatic staff in five colorado skilled nursing facilities: epidemiologic, virologic and sequence analysis.medRxiv [preprint]10.1101/2020.06.08.20125989

  • 100

    Quidel Corporation (2020a). QuickVue® SARS Antigen Test [package insert, EUA].San Diego, CA: Quidel Corporation.

  • 101

    Quidel Corporation (2020b). Sofia® SARS Antigen FIA [package insert, EUA].San Diego, CA: Quidel Corporation.

  • 102

    Quidel Corporation (2020c). Sofia® 2 Flu+SARS Antigen FIA [package insert, EUA].San Diego, CA: Quidel Corporation.

  • 103

    R Core Team (2020). R: A Language and Environment for Statistical Computing.Vienna: R Foundation for Statistical computing.

  • 104

    RansomE. M.PotterR. F.WallaceM. A.MitchellK. F.YarbroughM. L.BurnhamC. A.et al (2020). Comparison of extraction methods and thermocyclers for SARS-CoV-2 molecular detection using clinical specimens.J. Clin. Microbiol.58:e1622-20.

  • 105

    RastawickiW.GierczyñskiR.JuszczykG.MituraK.HenryB. M. (2021). Evaluation of PCL rapid point of care antigen test for detection of SARS-CoV-2 in nasopharyngeal swabs.J. Med. Virol.9319201922. 10.1002/jmv.26765

  • 106

    RezaeiM.Razavi BazazS.ZhandS.SayyadiN.JinD.StewartM. P.et al (2020). Point of care diagnostics in the Age of COVID-19.Diagnostics11:9. 10.3390/diagnostics11010009

  • 107

    RhoadsD.PeaperD. R.SheR. C.NolteF. S.WojewodaC. M.AndersonN. W.et al (2020). College of American Pathologists (CAP) microbiology committee perspective: caution must be used in interpreting the cycle Threshold (Ct) value.Clin. Infect. Dis.72e685e686.

  • 108

    SchunemannH.BrozekJ.GuyattG.OxmanA. (2013). GRADE Handbook for Grading Quality of Evidence and Strength of Recommendations. Available Online at: https://gdt.gradepro.org/app/handbook/handbook.html(accessed May 24, 2021).

  • 109

    SchwobJ. M.MiautonA.PetrovicD.PerdrixJ.SennN.JatonK.et al (2020). Antigen rapid tests, nasopharyngeal PCR and saliva PCR to detect SARS-CoV-2: a prospective comparative clinical trial.medRxiv [preprint]10.1101/2020.11.23.20237057

  • 110

    ScohyA.AnantharajahA.BodéusM.Kabamba-MukadiB.VerrokenA.Rodriguez-VillalobosH. (2020). Low performance of rapid antigen detection test as frontline testing for COVID-19 diagnosis.J. Clin. Virol.129:104455. 10.1016/j.jcv.2020.104455

  • 111

    SmithR. L.GibsonL. L.MartinezP. P.KeR.MirzaA.ConteM.et al (2021). Longitudinal assessment of diagnostic test performance over the course of acute SARS-CoV-2 infection.medRxiv [preprint]10.1101/2021.03.19.21253964

  • 112

    StokesW.BerengerB. M.PortnoyD.ScottB.SzelewickiJ.SinghT.et al (2021). Clinical performance of the Abbott Panbio with nasopharyngeal, throat, and saliva swabs among symptomatic individuals with COVID-19. Eur. J. Clin. Microbiol. Infect. Dis.40, 17211726. 10.1007/s10096-021-04202-9

  • 113

    StrömerA.RoseR.SchäferM.SchönF.VollersenA.LorentzT.et al (2020). Performance of a Point-of-Care Test for the Rapid Detection of SARS-CoV-2 Antigen.Microorganisms9:58. 10.3390/microorganisms9010058

  • 114

    TahamtanA.ArdebiliA. (2020). Real-time RT-PCR in COVID-19 detection: issusues affecting the results.Expert Rev. Mol. Diagn.20453454. 10.1080/14737159.2020.1757437

  • 115

    TakeuchiY.AkashiY.KatoD.KuwaharaM.MuramatsuS.UedaA.et al (2021). The evaluation of a newly developed antigen test (QuickNaviTM-COVID19 Ag) for SARS-CoV-2: a prospective observational study in Japan.J. Infect. Chemother.27890894. 10.1016/j.jiac.2021.02.029

  • 116

    ToptanT.EckermannL.PfeifferA. E.HoehlS.CiesekS.DrostenC.et al (2020). Evaluation of a SARS-CoV-2 rapid antigen test: potential to help reduce community spread?J. Clin. Virol.135:104713. 10.1016/j.jcv.2020.104713

  • 117

    TorresI.PoujoisS.AlbertE.ColominaJ.NavarroD. (2021). Evaluation of a rapid antigen test (PanbioTM COVID-19 Ag rapid test device) for SARS-CoV-2 detection in asymptomatic close contacts of COVID-19 patients.Clin. Microbiol. Infect.27636.e1636.e4.

  • 118

    TurcatoG.ZaboliA.PfeiferN.CiccarielloL.SibilioS.TezzaG.et al (2020). Clinical application of a rapid antigen test for the detection of SARS-CoV-2 infection in symptomatic and asymptomatic patients evaluated in the emergency department: a preliminary report.J. Infect.82e14e16.

  • 119

    Van der MoerenN.ZwartV. F.LodderE. B.Van Den BijllaardtW.Van EschH. R. J. M.StohrJ. J. J. M.et al (2020). Performance evaluation of a Sars-Cov-2 rapid antigentest: test performance in the community in the Netherlands.medRxiv [Preprint]10.1101/2020.10.19.20215202

  • 120

    van KampenJ.Van Der VijverD.FraaijP.HaagmansB.LamersM.OkbaN.et al (2020). Shedding of infectious virus in hospitalized patients with coronavirus disease-2019 (COVID-19): duration and key determinants.medRxiv [Preprint]10.1101/2020.06.08.20125310

  • 121

    ViechtbauerW. (2010). Conducting meta-analyses in R with the metafor Package.J. Stat. Softw.36:48.

  • 122

    VillaverdeS.Domínguez-RodríguezS.SabridoG.Pérez-JorgeC.PlataM.RomeroM. P.et al (2021). Diagnostic accuracy of the Panbio SARS-CoV-2 antigen rapid test compared with Rt-Pcr testing of Nasopharyngeal samples in the pediatric population.J. Pediatr.232287289.e4.

  • 123

    WalshK. A.JordanK.ClyneB.RohdeD.DrummondL.ByrneP.et al (2020). SARS-CoV-2 detection, viral load and infectivity over the course of an infection.J. Infect.81357371. 10.1016/j.jinf.2020.06.067

  • 124

    WangD.HuB.HuC.ZhuF.LiuX.ZhangJ.et al (2020). Clinical characteristicics of 138 Hospitalized patients with 2019 Novel Coronavirus–infected pneumonia in Wuhan, China.JAMA32310611069. 10.1001/jama.2020.1585

  • 125

    WangR.TaubenbergerJ. K. (2010). Methods for molecular surveillance of influenza.Expert Rev. Anti-Infective Therapy8517527.

  • 126

    WeitzelT.LegarragaP.IruretagoyenaM.PizarroG.VollrathV.AraosR.et al (2020). Comparative evaluation of four rapid SARS-CoV-2 antigen detection tests using universal transport medium.Travel Med. Infect. Dis.39:101942. 10.1016/j.tmaid.2020.101942

  • 127

    WellsG. A.SheaB.O’connellD.PetersonJ.WelchV.LososM.et al (2011). The Newcastle-Ottawa Scale (NOS) for Assessing the Quality of Nonrandomised Studies in Meta-Analysis. Available Online at http://www.ohri.ca/programs/clinical_epidemiology/oxford.asp(accessed May 24, 2021).

  • 128

    WolfelR.CormanV. M.GuggemosW.SeilmaierM.ZangeS.MullerM. A.et al (2020). Virological assessment of hospitalized patients with COVID-2019.Nature581465469. 10.1038/s41586-020-2196-x

  • 129

    YamamotoK.SuzukiM.YamadaG.SudoT.NomotoH.KinoshitaN.et al (2021). Utility of the antigen test for coronavirus disease 2019: factors influencing the prediction of the possibility of disease transmission.Int. J. Infect. Dis.1046572. 10.1016/j.ijid.2020.12.079

  • 130

    YoungS.TaylorS. N.CammarataC. L.VarnadoK. G.Roger-DalbertC.MontanoA. (2020). Clinical evaluation of BD Veritor SARS-CoV-2 point-of-care test performance compared to PCR-based testing and versus the Sofia 2 SARS Antigen point-of-care test.J. Clin. Microbiol.59:e2338-20.

Summary

Keywords

test sensitivity, SARS-CoV-2, diagnostic accuracy, rapid antigen testing, RT-PCR, meta-regression analysis, systematic review and meta-analysis, viral culture

Citation

Parvu V, Gary DS, Mann J, Lin Y-C, Mills D, Cooper L, Andrews JC, Manabe YC, Pekosz A and Cooper CK (2021) Factors that Influence the Reported Sensitivity of Rapid Antigen Testing for SARS-CoV-2. Front. Microbiol. 12:714242. doi: 10.3389/fmicb.2021.714242

Received

24 May 2021

Accepted

18 August 2021

Published

05 October 2021

Volume

12 - 2021

Edited by

Maurizio Sanguinetti, Catholic University of the Sacred Heart, Italy

Reviewed by

Piyush Baindara, University of Missouri, United States; Yean Kong Yong, Xiamen University, Malaysia

Updates

Copyright

*Correspondence: Charles K. Cooper,

This article was submitted to Infectious Diseases, a section of the journal Frontiers in Microbiology

Disclaimer

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Outline

Figures

Cite article

Copy to clipboard


Export citation file


Share article

Article metrics