ORIGINAL RESEARCH article

Front. Microbiol., 15 March 2023

Sec. Microbiotechnology

Volume 14 - 2023 | https://doi.org/10.3389/fmicb.2023.1113817

Subculturing and Gram staining of blood cultures flagged negative by the BACTEC™ FX system: Optimizing the workflow for detection of Cryptococcus neoformans in clinical specimens

  • 1. Department of Laboratory Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China

  • 2. Beijing Key Laboratory for Mechanisms Research and Precision Diagnosis of Invasive Fungal Diseases, Beijing, China

  • 3. Department of Clinical Laboratory, Nanchong Central Hospital, the Second Clinical Medical College, North Sichuan Medical College, Nanchong, China

  • 4. Jinan University, Guangzhou, Guangdong, China

  • 5. Department of Clinical Laboratory, Longhua District Central Hospital, Shenzhen, China

  • 6. Teaching Hospital of Guangdong Medical University, Guangdong, China

  • 7. Medical Research Center, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China

  • 8. Center for Infectious Diseases and Microbiology Laboratory Services, ICPMR—Pathology West, Westmead Hospital, University of Sydney, Westmead, NSW, Australia

  • 9. Graduate School, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China

Abstract

Objective:

To investigate whether an incubation time of 5 days (Aerobic/F, Anaerobic/F) and 14 days (Myco/F) blood culture bottles is sufficient to prevent false-negative results.

Methods:

We evaluated 1,244 blood bottles (344 patients) defined as negative by the BACTEC™ FX system. We also reviewed published cases and our own cases of bloodstream infection caused by Cryptococcus neoformans and simulated different scenarios, including different inoculation concentrations, bottle types, and clinical isolates.

Results:

Two bottles (0.16%) were found to contain C. neoformans when subcultured and Gram stained. A 5-day protocol with Aerobic/F bottles was insufficient for the growth of C. neoformans in some cases, and C. neoformans grew better in Myco/F bottles than in Aerobic/F bottles.

Conclusion:

Subculturing and Gram staining after a 5-day protocol were important for the detection of C. neoformans, and Myco/F bottles should be collected for the blood culture of C. neoformans.

1. Introduction

Bloodstream infection (BSI) is a major health burden worldwide, with mortality rates ranging from 20 to 50% (Magadia and Weinstein, 2001). Blood is one of the most important specimens received by the microbiology laboratory, as it plays an invaluable role in the detection and treatment of bacteremia and fungemia. Positive blood cultures should be promptly reported to clinicians, including the time-to-positivity, bottle type, Gram staining result, or the result of direct identification (Lamy, 2019). Some studies have confirmed that blood cultures incubated for <5 days are sufficient for the detection of infective endocarditis (Peuchant et al., 2019), neonatal sepsis (Biondi et al., 2014; Abdelhamid, 2017), or drug-resistant bacteria (Pan et al., 2019). However, most laboratories set the incubation time to 5–7 days (Janapatla et al., 2010; Ning et al., 2016; Cilloniz et al., 2017; Le Guern et al., 2021; Yarbrough et al., 2021) because the time-to-positivity of blood cultures can be influenced by blood volume in culture bottles (Chang et al., 2015; Kim et al., 2015; Jones et al., 2017; Birkhamshaw and Winzor, 2019; Henning et al., 2019; Khare et al., 2020), the initial inoculum (Klaerner et al., 2000), or prior exposure to antimicrobial agents (Driscoll et al., 2017). Like most laboratories, our laboratory sets the incubation time to 5 days with Aerobic/F bottles (14 days for yeast with Myco/F bottles, and 30 days for fungi with Myco/F bottles). We issue the first negative report at day 3 (Aerobic/F and Anaerobic/F bottles) and day 7 (Myco/F bottle), with the final report issued at day 5 and 14, respectively. Few studies have reassessed bottles defined as negative by Gram staining and/or inoculation on solid growth media (Peretz et al., 2015; Jacobs et al., 2017).

In our study, we evaluated 1,244 bottles defined as negative by the BACTEC™ FX system at the end of 5 days or 14 days (yeast) by using subculture and Gram stain. We also reviewed prior cases of BSI caused by C. neoformans and simulated several in vitro scenarios.

2. Materials and methods

2.1. Study design

The study was performed from September to October 2021 at Peking Union Medical College Hospital. Blood cultures (BACTEC™ PLUS-Aerobic/F Medium, BACTEC™-Lytic/10 Anaerobic/F Medium, and BACTEC™-Myco/F Lytic Medium; BD Diagnostics, Oxford Science Park, Oxford, United Kingdom) were sent to the microbiology laboratory. Distribution of patients was across different departments including emergency, intensive care unit, respiratory disease, cardiology, immunology, infectious diseases, neurology, and oncology. Aerobic/F and Anaerobic/F bottles were incubated in the BACTEC™ FX system for 5 days, and Myco/F bottles were incubated for 14 days for yeasts, such as Candida. The acceptable time period from bottle collection to placement onto the automated blood culture instruments should be within 2 h, and all of the bottles detected in the present study fulfilled this criteria.

2.2. Subculturing and Gram staining of negative bottles

Blood bottles, defined as negative by the BACTEC™ FX system after 5 days (Aerobic/F and Anaerobic/F bottles) or 14 days (Myco/F bottle), were subcultured and Gram stained (smear microscopy). The Aerobic/F bottles were subcultured onto chocolate agar, the Anaerobic/F bottles were subcultured onto anaerobic blood agar (Schaedler agar base supplemented with 5% sheep blood, vitamin K1, and hemin) and sealed in a disposable anaerobic bag (GENbag, Chemin de I’Ome 69280 Marcy L’ETOILE, France), and the Myco/F bottles were inoculated onto Sabouraud’s agar. To improve the subculture yield, the inoculum (four drops) was streaked closely and evenly, and cultured in 5% CO2 at 35°C for 15 days. Subcultured plates were reviewed for growth on days 2, 7, and 15 after inoculation according to our study design. If colonies were observed, they were identified by mass spectrometry (Antubio, China) and the original blood culture bottles were subcultured and Gram stained again to exclude possible contaminants (Figure 1). Contaminants or true pathogens were determined according to the criteria listed in Table 1.

Figure 1

Table 1

SubculturingGram stainingClinical diagnosis supporting BSIContaminants or Causative pathogens
+ (confirmed twice)+ (confirmed twice)YesCausative pathogens
+ (confirmed twice)− (confirmed twice)YesCausative pathogens
− (confirmed twice)+ (confirmed twice)YesCausative pathogens*
+1st/−2nd or + (confirmed twice)+ 1st/−2nd or + (confirmed twice)NoContaminants

Criteria used to assess contaminants or causative pathogens.

*

Metagenomic next-generation sequencing was used for the identification of pathogens. BSI, bloodstream infection.

When the original blood culture bottles were negative on subculturing but positive by Gram staining, metagenomic next-generation sequencing (Illumina NextSeq CN500) would be used for the identification of pathogens. The concentration of extracted DNA/RNA was measured using a Qubit Fluorometer before library preparation. DNA libraries were prepared via transposase-based methodology. Human rRNA was depleted from the RNA samples via an RNase H-based method before library preparation. After purification and size selection, the concentration of the RNA library was determined by using a Qubit instrument before pooling. Pooled libraries were sequenced on an Illumina NextSeq 550 system using a 75 bp, single-end sequencing kit (Illumina, San Diego). The qualified results had no fewer than 15 million reads obtained per sample and a Q30 score of 90% or greater. A negative control sample was processed and sequenced in parallel in each sequencing run for quality control. The 75 bp single-end reads from illumine Nextseq 550 were analyzed by in-house IDseq software to get each microorganism’s abundance. The detail process is as follows: high-quality sequencing data were generated by removing reads of low quality or short length (<35 bp) by using fastp (Chen et al., 2018). Human host sequences were subtracted by mapping to human reference genome sequences (National Center for Biotechnology Information GRCh38 assembly) using the Burrows-Wheeler Aligner tool (BWA) 1 (Li and Durbin, 2010). The data remaining after the removal of low-complexity reads were classified by alignment to curated microbial genome databases for viruses, bacteria, fungi, and parasites. Taxonomic references were downloaded from the National Center for Biotechnology Information.

2.3. Evaluation of different bottle types, sample volumes, and clinical isolates

Four C. neoformans isolates (Figure 2), namely H99 (C. neoformans reference clinical strain), 21B29228 (isolated from a patient in the present study; October 19, 2021), 21B29353 (isolated from the same patient; October 20, 2021), and 21B29354 (isolated from the same patient; October 20, 2021), were each serially diluted to final concentrations of 5–10, 50–100, and 500–1,000 colony-forming units (CFU)/ml in sterile saline. To simulate the ratio of 1:5/1:10 (blood volume/media), Aerobic/F bottles were inoculated with 10 mL of the three concentrations, giving final inoculation concentrations of 50–100, 500–1,000, and 5,000–10,000 CFU/bottle, respectively. Myco/F bottles were inoculated with 5 and 10 mL of the three concentrations to final inoculation concentrations of 25/50–50/100, 250/500–500/1,000 and 2,500/5,000–5,000/10,000 CFU/bottle, respectively. To enumerate the exact CFU inoculated, 100 μL of each concentration was plated on 5% Sabouraud’s agar plates, and colonies were counted after 48 h incubation at 35°C. Bottles were cultured in the BACTEC™ FX system until they appeared positive or until 7 days. The time-to-detection (TTD; defined as the time from loading to observation of a positive signal in the blood culture) was determined for each bottle. Bottles that failed to show a positive result were subcultured on Sabouraud’s agar plates after being unloaded.

Figure 2

2.4. Statistical analysis

Differences in the TTD between Myco/F and Aerobic/F bottles (Figure 3A) or between 5-and 10-mL samples (Figure 3B) were evaluated using a paired t test (two-tailed). Differences in the TTD among four different isolates (Figures 3C,D) were compared using one-way ANOVA (multiple comparisons). All statistical analyses were performed using GraphPad Prism, version 7.0, and differences were considered statistically significant at p < 0.05.

Figure 3

3. Results

We collected, subcultured, and Gram-stained 542 Aerobic/F bottles, 544 Anaerobic/F bottles, and 158 Myco/F bottles (all from 344 patients) defined as negative. Among the 542 Aerobic/F bottles, bacteria or fungi grew in four of the subcultured bottles and yeast-like cells (C. neoformans yeast cells were very round and displayed an amorphous orange-staining material, presumably the capsule) were detected in two of the Gram-stained bottles. In the two bottles that tested positive by subculturing and gave a negative smear result, Saccharomyces cerevisiae was detected in one bottle and Bacillus sp. in the other bottle. However, both tested negative after a second round of subculturing and Gram staining, and these organisms were therefore considered to be contaminants. For two of the subcultured bottles, which were collected from the same patient (21B29228, October 19, 2021; and 21B29354, October 20, 2021), C. neoformans was identified by mass spectrometry and yeast-like cells were also observed by Gram staining (Figure 2). The blood culture in the Myco/F bottle collected from the same patient was reported positive at 82 h (21B29353, October 20, 2021; Figure 2) and identified as C. neoformans by mass spectrometry. The subcultured and Gram-stained 544 Anaerobic/F bottles and 158 Myco/F bottles were negative. Therefore, the overall positive rate for re-examination of 1,244 bottles defined as negative according to our protocol was 0.16% (2/1244).

We reviewed the past 7 years of our laboratory records (unpublished data) and found 17 cases of BSI caused by C. neoformans. Among the 17 cases, three (17.6%) were detected only in Myco/F bottles; seven (41.2%) were detected in both Myco/F and Aerobic/F bottles; two (11.8%; 72 and 153 h) were detected only in Aerobic/F bottles; and five (29.2%) were cultured solely in Aerobic/F cultures and reported positive. For the 10 cases (58.8%) detected in Myco/F bottles, the average TTD was 75.4 h, and nine isolates of C. neoformans grew within the recommended incubation time (7 days) for yeast using Myco/F bottles (one required 179 h for growth). We compared the TTD between Myco/F and Aerobic/F bottles in seven cases (Figure 3A). The average ± SD TTD for Myco/F bottles was 60.57 ± 21.72 h, and that for Aerobic/F bottles was 84.00 ± 27.26 h, and the difference was significant (p = 0.0133).

We recovered the three C. neoformans isolates detected in the present study, namely 21B29228, 21B29353, and 21B29354, and H99 was used as a growth control. We seeded the four isolates into Myco/F and Aerobic/F bottles. Cryptococcus neoformans isolates grew faster in the Myco/F bottles than in the Aerobic/F bottles (Figure 3A), with time differences of 26.5, 18.3, and 28.3 h at inoculation concentrations of 5,000–10,000, 500–1,000, and 50–100 CFU/bottle, respectively (p < 0.05). A high blood volume (indicating a high inoculum) shortened the average TTD from 77.00 ± 22.07 to 73.42 ± 21.77 h (p < 0.05; Figure 3B). Isolates 21B29228, 21B29353, and 21B29354 grew slower than H99 (Figure 3C), and 21B29354 grew slower than 21B29353 and 21B29228 (Figure 3D; p < 0.05).

4. Discussion

Because bacteremia and fungemia are life-threatening infections, the detection and identification of microorganisms from blood are crucial. Blood culture is commonly based on the measurement of CO2 production, such as with the BACTEC™ FX (BD Diagnostics) system (Chang et al., 2015; Peretz et al., 2015), or the measurement of CO2-derived pH changes, such as with the BacT/ALERT system (bioMérieux; Kim et al., 2015; Jacobs et al., 2017; Emeraud et al., 2021), by which 99% of positive Aerobic/F and Anaerobic/F bottles with BacT/Alert Virtuo (Virtuo) blood culture detection system are confirmed to be positive within 5 days (Ransom et al., 2021). However, false-negative results can arise when the incubation time is set to 5 or 7 days, because of slowly proliferating microorganisms (Peretz et al., 2015), insufficient blood volume (Kim et al., 2015), or prior use of antimicrobial agents (Houpikian and Raoult, 2005).

To improve detection procedures, the current study reviewed blood cultures that were reported as negative according to our hospital’s protocol. Two Aerobic/F bottles tested positive for C. neoformans (Figure 2). As a Myco/F bottle for this patient was flagged as positive at 82 h (within the recommended 7 days incubation for Myco/F culture of yeast), these false-negative bottles would not have affected the clinical management. However, our blood culture audit did reveal occasions when the diagnosis of cryptococcemia relied solely on the Aerobic/F bottles. Thus, it is important to explore the potential factors contributing to the failure of the Aerobic/F bottles to detect Cryptococcus. We hypothesize that the presence of antifungals, a short incubation time, and a small blood volume may contribute.

Initial treatment with amphotericin B was implemented immediately following primary diagnosis of cryptococcal meningitis using cerebrospinal fluid ink staining. Blood was collected before the next dose was administered (24 h; Figure 2), so growth inhibition by amphotericin B could not be predicted (immediate treatment was needed, which can obscure subsequent testing results). We recovered three isolates (21B29354, 21B29353, and 21B29228) and reseeded them into Myco/F and Aerobic/F bottles (at concentrations of 5,000–10,000, 500–1,000, and 50–100 CFU/bottle) in the absence of any antifungal agents. Myco/F bottles reseeded with 21B29354, 21B29353, and 21B29228 flagged positive at 82 h, at a concentration of 500–1,000 CFU/bottle (data not shown here). At that concentration, all three isolates reseeded into Aerobic/F bottles flagged positive at 89–107 h, within the recommended incubation time of 5 days. However, at a concentration of 50–100 CFU/bottle, isolates 21B29354 and 21B29353 flagged positive at 129–137 h, outside the recommended incubation time of 5 days. If the lack of detection of Aerobic/F bottles is attributable to antifungal agents, the shorter TTD in Myco/F bottles cannot be explained because Aerobic/F bottles contain resin that can adsorb antimicrobial agents, but Myco/F bottles do not. However, there are two possible explanations: (1) the media in Myco/F bottles facilitates better growth of C. neoformans compared with that in Aerobic/F bottles (which remains to be confirmed) and (2) the lower initial inoculum in Aerobic/F bottles prolongs the TTD (as confirmed by the results mentioned above).

Previous studies using Difco ESP 384 (Robinson et al., 1987; Tinghitella and Lamagdeleine, 1995), BACTEC™ (Araj et al., 1981), and BBL Microbiology (Gill, 1981; Table 2) systems also reported that Aerobic/F bottles failed to detect C. neoformans isolates with a 5- or 7-day protocol (Table 2). To evaluate the comparative TTD of Myco/F and Aerobic/F bottles for C. neoformans, we reviewed the past 7 years of data. We collected 17 BSI cases caused by C. neoformans from our hospital (unpublished data), and compared the TTD reported for Myco/F and Aerobic/F bottles (Figure 3A). Myco/F bottles detected C. neoformans 23.43 ± 17.88 h prior to Aerobic/F bottles, based on the BACTEC™ FX system. Experiments using the four recovered C. neoformans isolates gave similar results, with C. neoformans being detected in Myco/F bottles 24.33 ± 13.52 h prior to Aerobic/F bottles, based on the BACTEC™ FX system (Figure 3A). Furthermore, in five previous cases of BSI caused by C. neoformans, Myco/F bottles were not designated for use in the whole process. Indeed, most of our C. neoformans isolates in Aerobic/F and Myco/F bottles were detected within 5 days, but some isolates needed a longer time (one case flagged positive at 153 h in an Aerobic/F bottle, and another at 179 h in an Myco/F bottle). This may have resulted from phenotypic differences among the strains or the initial inoculum concentration in the blood. Growth of the three C. neoformans isolates in the present study was slower than the growth of control H99 and other isolates reported previously (within 72 h; Zhang et al., 2019). Similarly, 21B29354 collected on October 20, 2021 grew slower than 21B29228 collected on October 19, 2021 (p < 0.05), despite being derived from the same patient. The growth curves of the three bottles were checked. An extended incubation time for the two Aerobic/F bottles was required because they were likely to flag positive after 5 days. Therefore, a 5-day protocol with Aerobic/F bottles was insufficient for the growth of C. neoformans in some cases, and Myco/F bottles performed better than Aerobic/F bottles for the growth of C. neoformans.

Table 2

Blood culture systemDetection methodsIncubation time in automated blood culture systemNo. of subcultured positive casesMicrobe detected in negative blood culture bottlesReferences
Difco ESP 384Gram staining and Subcultivation5 days16 (1.4%; 16/1162)Cryptococcus neoformans (n = 8), Candida albicans (n = 1), Staphylococcus aureus (n = 2), Coagulase-negative staphylococcus (n = 3), Bacillus sp. (n = 1), and Corynebacterium sp. (n = 1)Tinghitella and Lamagdeleine (1995)
Bactec® 460 RadiometricSubcultivation7 daysEight (in a patient with AIDS)Cryptococcus neoformans (n = 8)Robinson et al. (1987)
BACTECSubcultivation7 days15 (0.3%; 15/5345)Cryptococcus neoformans (n = 8), Staphylococcus epidermidis (n = 1), Bacillus cereus (n = 1) Corynebacterium sp. (n = 1) Coccidioides immitis (n = 4)Araj et al. (1981)
Subcultivation7 days12 (0.8%; 12/14,000)Cryptococcus neoformans (n = 1), Staphylococcus aureus (n = 2), Pseudomonas aeruginosa (n = 2), Candida tropicalis (n = 3), Staphylococcus epidermidis (n = 1), Neisseria meningitidis (n = 1), Acinetobacter calcoaceticus subsp. anitratus (n = 1), and Klebsiella pneumoniae (n = 1)29
BACTEC FXGram staining and subcultivation5 days2 (1.6‰; 2/1244)Cryptococcus neoformans (n = 2)Present study

Literature review of automated blood culture systems that failed to detect Cryptococcus neoformans.

According to the manufacturer’s instructions, Myco/F bottles should be seeded with up to 5 mL of blood. We compared the TTD between the 5- and 10-mL samples and confirmed that the latter shortened the average TTD by 3.59 ± 2.83 h (p < 0.05). Therefore, we suggest that the high blood volume or high inoculum concentration in Myco/F bottles may have contributed to the positive results.

We also compared the TTD between Aerobic/F bottles with 10-mL samples and Myco/F bottles with 5-mL samples at three concentrations. Myco/F bottles detected C. neoformans on the BACTEC™ FX system 25.75 ± 14.13 h (5,000–10,000 CFU/bottle), 14.75 ± 12.40 h (500–1,000 CFU/bottle), and 21.75 ± 13.17 h (50–100 CFU/bottle) prior to Aerobic/F bottles, which also confirmed the preferability of Myco/F bottle use for the detection of C. neoformans.

We also reviewed the time from sampling to loading of the bottles in the incubation system and confirmed that all bottles collected from this patient infected by C. neoformans were loaded into the BACTEC™ FX system within 1 h of blood culture collection. Thus, the difference in the ability to recover Cryptococcus was unlikely caused by transport and/or a delay in loading.

On the basis of the results above, we were able to optimize our workflow in four parts. (1) When a clinical diagnosis of cryptococcal infection is made or suspected, Myco/F bottles should be collected, and the incubation time for Aerobic/F bottles should be extended to 14 days. If the Aerobic/F bottles are defined as negative at 5 days, they should be subcultured and Gram stained. (2) When a positive result is obtained for ink staining of the cerebrospinal fluid and/or sputum, and/or cryptococcal antigen is positively detected, Myco/F bottles should be collected, and the incubation time of Aerobic/F bottles should be extended to 14 days. If the Aerobic/F bottles are defined as negative at 5 days, they should be subcultured and Gram stained. (3) When one or two bottles of a set of bottle cultures (Aerobic/F bottles) are flagged positive, the incubation time for other bottles (Aerobic/F bottles) from the same set and other sets should be extended to 14 days and they should be subcultured and Gram stained at 5 days (Aerobic/F bottles). (4) To increase the pre-test probability of a patient having C. neoformans infection (e.g., known exposure, immunosuppression due to HIV, chemotherapy, etc.), subculture and Gram staining of the bottles at the end of routine incubation times would also be performed.

In addition to optimizing our workflow, future studies are necessary to assess more rapid and sensitive approaches (Iroh Tam et al., 2018; Zrodlowski et al., 2018; Kidd et al., 2019; Ogbebor et al., 2021; Pecoraro et al., 2021), such as quantitative real-time PCR, nested multiplex real-time PCR, next-generation sequencing, and fluorescent in situ hybridization. Human blood has traditionally been considered to be an entirely sterile environment, but evidence for the existence of a healthy human blood microbiome is steadily accumulating (Castillo et al., 2019). When deciding whether microorganisms are contaminants or causative pathogens, results should be interpreted according to the clinical context. In the cases reported in this study, C. neoformans was definitely a causative pathogen.

Our study had some limitations. (1) We only collected a small number of bottles defined as negative by the BACTEC™ FX system, and more relevant cases may be found if a larger number of bottles were included. (2) We analyzed and calculated results according to bottles, not patients (n = 344); therefore, some bottles were collected from the same patients. (3) We did not evaluate the BacT/ALERT system because of the small number of bottles used in our hospital. (4) This study made the organism dilutions using saline not human blood, which may skew the results toward prolonged organism recovery/growth in the blood culture bottles. (5) Due to different growth rates between the patient isolate and the control isolate, the observed TTD data may not be generalized globally. And the modified workflow is a proof of concept study, which needs to be further validated using many different strains of C. neoformans from different parts of the world.

Overall, we found that a 5-day protocol with Aerobic/F bottles was insufficient for the growth of C. neoformans in some cases. Furthermore, Myco/F bottles performed better than Aerobic/F bottles regarding the growth of C. neoformans. Subculturing and Gram staining after a 5-day protocol were important for the detection of C. neoformans, and laboratories should ensure that Myco/F bottles are used for blood culture of C. neoformans.

Funding

This work was supported by the Special Foundation for National Science and Technology Basic Research Program of China (No. 2019FY101200), the National Key Research and Development Program of China (No. 2021YFC2400905), and the Beijing Key Clinical Specialty for Laboratory Medicine-Excellent Project (No. ZK201000).

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Statements

Data availability statement

The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.

Ethics statement

The studies involving human participants were reviewed and approved by only de-identified, clinically-obtained, bacterial isolates were used in the present study; no human subjects were involved (including the use of tissue samples). The study was approved by the Human Research Ethics Committee of Peking Union Medical College Hospital (No. ZS-3260). Written informed consent for participation was not required for this study in accordance with the national legislation and the institutional requirements.

Author contributions

YL designed the study. YL, LL, and LD analyzed the data. LL, LD, and SH performed the experiments. LL, LD, and TS prepared the experimental materials. YL wrote the original manuscript. YL and FK revised the manuscript. YX supervised the project. All authors contributed to the article and approved the submitted version.

Acknowledgments

We thank Hiu Tat Chan, from the Department of Physiology, Anatomy and Microbiology, La Trobe University, Australia, for revising the manuscript. We thank Cathel Kerr, BSc, PhD, from Liwen Bianji (Edanz; www.liwenbianji.cn) for editing the English text of a draft of this manuscript.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

References

  • 1

    AbdelhamidS. M. (2017). Time to positivity and antibiotic sensitivity of neonatal blood cultures. J. Global Infect. Dis.9, 102107. doi: 10.4103/jgid.jgid_1_17

  • 2

    ArajG. F.HopferR. L.WenglarM.FainsteinV. (1981). Valuable of terminal subcultures from negative BACTEC blood culture bottles. J. Clin. Microbiol.14, 589590. doi: 10.1128/jcm.14.5.589-590.1981

  • 3

    BiondiE. A.MischlerM.JerardiK. E.StatileA. M.FrenchJ.EvansR.et al. (2014). Blood culture time to positivity in febrile infants with bacteremia. JAMA Pediatr.168, 844849. doi: 10.1001/jamapediatrics.2014.895

  • 4

    BirkhamshawE.WinzorG. (2019). Increasing the volume of blood received in adult paired blood culture bottles at a regional public health laboratory: results of a quality improvement project to optimise the diagnosis of bacteraemia. Infect. Prev. Pract.1:100007. doi: 10.1016/j.infpip.2019.100007

  • 5

    CastilloD. J.RifkinR. F.CowanD. A.PotgieterM. (2019). The healthy human blood microbiome: fact or fiction?Front. Cell. Infect. Microbiol.9:148. doi: 10.3389/fcimb.2019.00148

  • 6

    ChangJ.ParkJ. S.ParkS.ChoiB.YoonN. S.SungH.et al. (2015). Impact of monitoring blood volume in the BD BACTEC FX blood culture system: virtual volume versus actual volume. Diagn. Microbiol. Infect. Dis.81, 8993. doi: 10.1016/j.diagmicrobio.2014.11.001

  • 7

    ChenS. F.ZhouY. Q.ChenY. R.GuJ. (2018). Fastp: an ultra-fast all-in-one FASTQ preprocessor. Bioinformatics34, i884i890. doi: 10.1093/bioinformatics/bty560

  • 8

    CillonizC.CeccatoA.de la CalleC.GabarrusA.Garcia-VidalC.AlmelaM.et al. (2017). Time to blood culture positivity as a predictor of clinical outcomes and severity in adults with bacteremic pneumococcal pneumonia. PLoS One12:e0182436. doi: 10.1371/journal.pone.0182436

  • 9

    DriscollA. J.Deloria KnollM.HammittL. L.BaggettH. C.BrooksW. A.FeikinD. R.et al. (2017). The effect of antibiotic exposure and specimen volume on the detection of bacterial pathogens in children with pneumonia. Clin. Infect. Dis.64, S368S377. doi: 10.1093/cid/cix101

  • 10

    EmeraudC.YilmazS.FortineauN.CuzonG.DortetL. (2021). Quality indicators for blood culture: 1 year of monitoring with BacT/Alert Virtuo at a French hospital. J. Med. Microbiol.70:01300. doi: 10.1099/jmm.0.001300

  • 11

    GillV. J. (1981). Lack of clinical relevance in routine terminal subculturing of blood cultures. J. Clin. Microbiol.14, 116118. doi: 10.1128/jcm.14.1.116-118.1981

  • 12

    HenningC.AygulN.DinnetzP.WallgrenK.OzenciV. (2019). Detailed analysis of the characteristics of sample volume in blood culture bottles. J. Clin. Microbiol.57:e0026819. doi: 10.1128/JCM.00268-19

  • 13

    HoupikianP.RaoultD. (2005). Blood culture-negative endocarditis in a reference center: etiologic diagnosis of 348 cases. Medicine (Baltimore)84, 162173. doi: 10.1097/01.md.0000165658.82869.17

  • 14

    Iroh TamP. Y.Hernandez-AlvaradoN.SchleissM. R.YiA. J.Hassan-HangaF.OnuchukwuC.et al. (2018). Detection of Streptococcus pneumoniae from culture-negative dried blood spots by real-time PCR in Nigerian children with acute febrile illness. BMC. Res. Notes11:657. doi: 10.1186/s13104-018-3770-2

  • 15

    JacobsM. R.MazzulliT.HazenK. C.GoodC. E.AbdelhamedA. M.LoP.et al. (2017). Multicenter clinical evaluation of BacT/Alert Virtuo blood culture system. J. Clin. Microbiol.55, 24132421. doi: 10.1128/JCM.00307-17

  • 16

    JanapatlaR. P.YanJ. J.ChienM. L.ChenH. M.WuH. M.WuJ. J. (2010). Effect of overnight storage of blood culture bottles on bacterial detection time in the BACTEC 9240 blood culture system. J. Microbiol. Immunol. Infect.43, 126132. doi: 10.1016/S1684-1182(10)60020-5

  • 17

    JonesR. L.SaylesH. R.FeyP. D.RuppM. E. (2017). Effect of clinical variables on the volume of blood collected for blood cultures in an adult patient population. Infect. Control Hosp. Epidemiol.38, 14931497. doi: 10.1017/ice.2017.230

  • 18

    KhareR.KothariT.CastagnaroJ.HemmingsB.TsoM.JuretschkoS. (2020). Active monitoring and feedback to improve blood culture fill volumes and positivity across a large integrated health system. Clin. Infect. Dis.70, 262268. doi: 10.1093/cid/ciz198

  • 19

    KiddS. E.ChenS. C.MeyerW.HallidayC. L. (2019). A new age in molecular diagnostics for invasive fungal disease: are we ready?Front. Microbiol.10:2903. doi: 10.3389/fmicb.2019.02903

  • 20

    KimS. C.KimS.LeeD. H.ChoiS. R.KimJ. S. (2015). Effect of blood volume in standard anaerobic blood culture bottles of the BacT/ALERT 3D system used for the detection of pathogens and time to detection. PLoS One10:e0116728. doi: 10.1371/journal.pone.0116728

  • 21

    KlaernerH. G.EschenbachU.KamereckK.LehnN.WagnerH.MiethkeT. (2000). Failure of an automated blood culture system to detect nonfermentative gram-negative bacteria. J. Clin. Microbiol.38, 10361041. doi: 10.1128/JCM.38.3.1036-1041.2000

  • 22

    LamyB. (2019). Blood culture time-to-positivity: making use of the hidden information. Clin. Microbiol. Infect.25, 268271. doi: 10.1016/j.cmi.2018.12.001

  • 23

    Le GuernR.TitecatM.LoiezC.DuployezC.WalletF.DesseinR. (2021). Comparison of time-to-positivity between two blood culture systems: a detailed analysis down to the genus-level. Eur. J. Clin. Microbiol. Infect. Dis.40, 13991404. doi: 10.1007/s10096-021-04175-9

  • 24

    LiH.DurbinR. (2010). Fast and accurate long-read alignment with burrows-wheeler transform. Bioinformatics26, 589595. doi: 10.1093/bioinformatics/btp698

  • 25

    MagadiaR. R.WeinsteinM. P. (2001). Laboratory diagnosis of bacteremia and fungemia. Infect. Dis. Clin. N. Am.15, 10091024. doi: 10.1016/s0891-5520(05)70184-7

  • 26

    NingY.HuR.YaoG.BoS. (2016). Time to positivity of blood culture and its prognostic value in bloodstream infection. Eur. J. Clin. Microbiol. Infect. Dis.35, 619624. doi: 10.1007/s10096-016-2580-5

  • 27

    OgbeborO.PawateV.WooJ.KellyK.CerejoR.BhanotN. (2021). Bartonella endocarditis presenting as recurrent cerebral mycotic aneurysm. Cureus13:e19969. doi: 10.7759/cureus.19969

  • 28

    PanF.ZhaoW.ZhangH. (2019). Value of time to positivity of blood culture in children with bloodstream infections. Can. J. Infect. Dis. Med. Microbiol.2019:5975837. doi: 10.1155/2019/5975837

  • 29

    PecoraroA. A.HerbstP. P.PienaarC. C.TaljaardJ. J.ProzeskyH. H.JansonJ. J.et al. (2021). Bartonella species as a cause of culture-negative endocarditis in South Africa. Eur. J. Clin. Microbiol. Infect. Dis.40, 18731879. doi: 10.1007/s10096-021-04239-w

  • 30

    PeretzA.IsakovichN.PastukhN.KoifmanA.GlyatmanT.BrodskyD. (2015). Performance of gram staining on blood cultures flagged negative by an automated blood culture system. Eur. J. Clin. Microbiol. Infect. Dis.34, 15391541. doi: 10.1007/s10096-015-2383-0

  • 31

    PeuchantO.IssaN.MachelartI.GreibC.WirthG.CamouF. (2019). What is the time-to-positivity of blood cultures in infective endocarditis?Eur. J. Clin. Microbiol. Infect. Dis.38, 15771579. doi: 10.1007/s10096-019-03566-3

  • 32

    RansomE. M.AlipourZ.WallaceM. A.BurnhamC. A. (2021). Evaluation of optimal blood culture incubation time to maximize clinically relevant results from a contemporary blood culture instrument and media system. J. Clin. Microbiol.59:e0245920. doi: 10.1128/JCM.02459-20

  • 33

    RobinsonP. G.SulitaM. J.MatthewsE. K.WarrenJ. R. (1987). Failure of the Bactec 460 radiometer to detect Cryptococcus neoformans fungemia in an AIDS patient. Am. J. Clin. Pathol.87, 783786. doi: 10.1093/ajcp/87.6.783

  • 34

    TinghitellaT. J.LamagdeleineM. D. (1995). Assessment of Difco ESP 384 blood culture system by terminal subcultures: failure to detect Cryptococcus neoformans in clinical specimens. J. Clin. Microbiol.33, 30313033. doi: 10.1128/jcm.33.11.3031-3033.1995

  • 35

    YarbroughM. L.WallaceM. A.BurnhamC. D. (2021). Comparison of microorganism detection and time to positivity in pediatric and standard media from three major commercial continuously monitored blood culture systems. J. Clin. Microbiol.59:e0042921. doi: 10.1128/JCM.00429-21

  • 36

    ZhangY.CooperB.GuiX.ShererR.CaoQ. (2019). Clinical diversity of invasive cryptococcosis in AIDS patients from Central China: report of two cases with review of literature. BMC Infect. Dis.19:1003. doi: 10.1186/s12879-019-4634-7

  • 37

    ZrodlowskiT. W.Jurkiewicz-BadaczD.Sroka-OleksiakA.SalamonD.BulandaM.GosiewskiT. (2018). Comparison of PCR, fluorescent in situ hybridization and blood cultures for detection of bacteremia in children and adolescents during antibiotic therapy. Pol. J. Microbiol.67, 479486. doi: 10.21307/pjm-2018-056

Summary

Keywords

bloodstream infection, subculture, blood culture, BACTEC™ FX, Cryptococcus neoformans

Citation

Liu L, Du L, He S, Sun T, Kong F, Liu Y and Xu Y (2023) Subculturing and Gram staining of blood cultures flagged negative by the BACTEC™ FX system: Optimizing the workflow for detection of Cryptococcus neoformans in clinical specimens. Front. Microbiol. 14:1113817. doi: 10.3389/fmicb.2023.1113817

Received

01 December 2022

Accepted

28 February 2023

Published

15 March 2023

Volume

14 - 2023

Edited by

Ren-Cun Jin, Hangzhou Normal University, China

Reviewed by

Claudio Farina, ASST “Papa Giovanni XXIII, Italy; Bobby Boyanton, University of Arkansas for Medical Sciences, United States

Updates

Copyright

*Correspondence: Yali Liu, Yingchun Xu,

†These authors have contributed equally to this work and share first authorship

This article was submitted to Microbiotechnology, a section of the journal Frontiers in Microbiology

Disclaimer

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Outline

Figures

Cite article

Copy to clipboard


Export citation file


Share article

Article metrics