Your new experience awaits. Try the new design now and help us make it even better

ORIGINAL RESEARCH article

Front. Pharmacol.

Sec. Respiratory Pharmacology

This article is part of the Research TopicResearch and Innovation Approaches to Personalized Pharmacotherapies for Respiratory DiseasesView all 9 articles

Stability of Formoterol concentration in Scalp Hair of patients using maintenance Formoterol Therapy for Asthma or COPD (INCTFISH)

Provisionally accepted
Esther  SportelEsther Sportel1*Kay  WagelaarKay Wagelaar1Marjolein  BrusseMarjolein Brusse2,3Job  Van Der PalenJob Van Der Palen2,4Ilonka  Van VeenIlonka Van Veen5Mireille  WesselsMireille Wessels6Job  Van BovenJob Van Boven6,7Daan  TouwDaan Touw6,8Kris  MovigKris Movig1
  • 1Department of Clinical Pharmacy, Medisch Spectrum Twente, Enschede, Netherlands
  • 2Department of Epidemiology, Medisch Spectrum Twente, Enschede, Netherlands
  • 3Section Cognition, Data and Education, Universiteit Twente, Enschede, Netherlands
  • 4Health Technology and Services Research, Universiteit Twente, Enschede, Netherlands
  • 5Department of Clinical Pulmonology, Medisch Spectrum Twente, Enschede, Netherlands
  • 6Department of Clinical Pharmacy and Pharmacology, Universitair Medisch Centrum Groningen, Groningen, Netherlands
  • 7Universitair Medisch Centrum Groningen Groningen Research Institute for Asthma and COPD, Groningen, Netherlands
  • 8Rijksuniversiteit Groningen Groningen Research Institute of Pharmacy, Groningen, Netherlands

The final, formatted version of the article will be published soon.

Introduction Hair testing provides a non-invasive, objective method with a long (retrospective) surveillance window for assessing medication adherence. Previous studies have developed a method to analyze formoterol in hair and suggest a possible dose-response relationship. The INCTFISH study aims to assess the stability of formoterol concentrations in hair in patients using formoterol for asthma or COPD maintenance therapy. Methods In total, 13 subjects ≥ 18 years of age, with asthma or COPD, who demonstrated stable to intermediate adherence and medication possession ratio, were included in this pilot study. To study the stability of formoterol, two hair segments located at one and three centimeters from the patient’s scalp were collected, corresponding to a time frame of approximately three months. Scalp hair samples were taken during a study visit and analyzed using Liquid Chromatography-Tandem Mass Spectrometry. Results Inhaled formoterol was detected in most hair samples with all hair colors in a concentration range of 0.73-7.6 ng/g. The intraclass correlation between segment one and two was excellent (ICC=0.97). Discussion The pilot study reveals a strong correlation between formoterol concentrations in segment one and two, indicating that drug levels remain stable in hair over a period of at least three months. While the study does not yet provide sufficient evidence to establish the utility of hair testing for monitoring formoterol adherence, it provides important directions for future research.

Keywords: Hair analysis, Formoterol, adherence, Smart Inhaler, Asthma, COPD

Received: 27 Aug 2025; Accepted: 31 Oct 2025.

Copyright: © 2025 Sportel, Wagelaar, Brusse, Van Der Palen, Van Veen, Wessels, Van Boven, Touw and Movig. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

* Correspondence: Esther Sportel, e.sportel@mst.nl

Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.