CORRECTION article

Front. Cell. Infect. Microbiol., 20 September 2023

Sec. Bacteria and Host

Volume 13 - 2023 | https://doi.org/10.3389/fcimb.2023.1272773

Corrigendum: Antibiotic susceptibility pattern of Portuguese environmental Legionella isolates

  • 1. NOVA Medical School, Faculdade de Ciências Médicas, Universidade NOVA de Lisboa, Lisboa, Portugal

  • 2. Comprehensive Health Research Center, NOVA Medical School, Faculdade de Ciências Médicas, Universidade NOVA de Lisboa, Lisboa, Portugal

  • 3. Laboratório de Análises de Água, Técnico Lisboa, Universidade de Lisboa, Lisboa, Portugal

Article metrics

View details

2

Citations

1,1k

Views

439

Downloads

Error in Figure/Table

In the published article, there was an error in Table 1 as published. Five lines are missing from the table. The corrected Table 1 and its caption Cumulative percentages of MIC distribution of environmental Legionella isolates (n = 57) obtained by manual and automated reading (signalized with *) appear below.

Table 1

MIC distributions (mg/L)
0.0080.0160.0320.0640.1250.250.51248163264
AZT428689398100
CLA791974969698100
CIP56889396100
LEV2370899698100
DOX21432639598100
AZT*21338696100
CLA*212194470899698+
CIP*2497789919698+
LEV*196375919698100
DOX*2716307295100

Cumulative percentages of MIC distribution of environmental Legionella isolates (n = 57) obtained by manual and automated reading (signalized with *).

+) For two isolates it was not possible to determine the MIC for the automated reading of CLA and CIP, respectively. T, Azithromycin; CLA, Clarithromycin; CIP, Ciprofloxacin; LEV, levofloxacin; DOX, Doxycycline.

ECOFFs are represented in grey shading.

The authors apologize for this error and state that this does not change the scientific conclusions of the article in any way. The original article has been updated.

Statements

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Summary

Keywords

Legionella, broth microdilution, MIC, fluoroquinolones, macrolides, environmental, antibiotic susceptibility

Citation

Cruz C, Rodrigues L, Fernandes F, Santos R, Paixão P and Chasqueira MJ (2023) Corrigendum: Antibiotic susceptibility pattern of Portuguese environmental Legionella isolates. Front. Cell. Infect. Microbiol. 13:1272773. doi: 10.3389/fcimb.2023.1272773

Received

04 August 2023

Accepted

11 August 2023

Published

20 September 2023

Volume

13 - 2023

Edited and reviewed by

Diane S. J. Lindsay, NHS Greater Glasgow and Clyde, United Kingdom

Updates

Copyright

*Correspondence: Maria Jesus Chasqueira,

Disclaimer

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Outline

Cite article

Copy to clipboard


Export citation file


Share article

Article metrics