ORIGINAL RESEARCH article

Front. Cardiovasc. Med., 11 October 2021

Sec. Cardiac Rhythmology

Volume 8 - 2021 | https://doi.org/10.3389/fcvm.2021.728885

Atrial High-Rate Event Incidence and Predictors in Patients With Permanent Pacemaker Implantation

    JH

    Jian Hua Chen 1

    GY

    Guo Yao Chen 2

    HZ

    Hong Zheng 1

    QH

    Quan He Chen 2

    FY

    Fa Yuan Fu 1

    FL

    Fei Long Zhang 1

    LL

    Liang Long Chen 1

    WW

    Wei Wei Wang 1*

  • 1. Department of Cardiology, Fujian Provincial Institute of Coronary Disease, Fujian Heart Medical Center, Fujian Medical University Union Hospital, Fuzhou, China

  • 2. Union Clinic Medical College, Fujian Medical University, Fuzhou, China

Article metrics

View details

2

Citations

3,4k

Views

941

Downloads

Abstract

Objective: The present study aims to investigate the incidence and predictors of atrial high-rate events (AHREs) in patients with permanent pacemaker implants.

Methods: A total of 289 patients who were implanted with a dual-chamber pacemaker due to complete atrioventricular block or symptomatic sick sinus syndrome (SSS) and had no previous history of atrial fibrillation were included in the present study. AHREs are defined as events with an atrial frequency of ≥175 bpm and a duration of ≥5 min. The patients were divided into two groups according to whether or not AHREs were detected during the follow-up: group A (AHRE+, n = 91) and group N (AHRE–, n = 198).

Results: During the 12-month follow-up period, AHREs were detected in 91 patients (31.5%). The multivariate Cox regression analysis revealed that patient age [odds ratio [OR] = 1.041; 95% confidence interval [CI], 1.018–1.064; and P < 0.001], pacemaker implantation due to symptomatic SSS (OR = 2.225; 95% CI, 1.227–4.036; and P = 0.008), and the percentage of atrial pacing after pacemaker implantation (OR = 1.010; 95% CI, 1.002–1.017; and P = 0.016) were independent AHRE predictors.

Conclusion: The AHRE detection rate in patients with pacemaker implants was 31.5%. Patient age, pacemaker implantation due to symptomatic SSS, and the percentage of atrial pacing after pacemaker implantation were independent AHRE predictors.

Introduction

Cardiac implantable electronic devices (CIEDs) with atrial leads can detect atrial arrhythmia events whether or not the patient has symptoms (1). The European Society of Cardiology 2020 Guidelines for the Diagnosis and Management of Atrial Fibrillation (2) defines atrial high-rate events (AHREs) as events with an atrial frequency of ≥175 bpm and a duration of ≥5 min. AHREs are associated with an increased risk of clinical atrial fibrillation (AF) (3), ischemic stroke or systemic embolism (4), and cardiovascular death (5). A relevant study revealed that patient age, previous AF history, white blood cell count, and an increased C-reactive protein level were associated with AHRE occurrence (6). CIEDs include the permanent pacemaker (PPM), implantable cardioverter-defibrillator (ICD), and cardiac resynchronization therapy (CRT) instruments. However, there is no definite conclusion regarding the factors related to AHREs after PPM implantation. The present study aims to investigate the incidence and predictive factors of AHREs after PPM implantation in order to provide a reliable basis for the clinical identification of patients with a high AHRE risk.

Methods

Subjects: The present study enrolled a total of 377 patients with a complete atrioventricular block (AVB) and symptomatic sick sinus syndrome (SSS) who met the class I or class IIa pacemaker implantation indications in accordance with the guidelines for the treatment of pacemakers with abnormal cardiac rhythm (7) and underwent dual-chamber PPM implantation. Of these patients, 308 met the inclusion and exclusion criteria.

Inclusion criteria: (1) Patients aged ≥18 years; (2) patients with no clinical evidence of a past AF attack; (3) patients with a ventricular pacing lead implantation site in the right ventricular septal plane and atrial pacing lead implantation site in the right atrial appendage; and (4) patients in whom the implanted pacemaker could diagnose and record atrial arrhythmia.

Exclusion criteria: (1) Patients aged <18 years; (2) patients with clinical evidence of AF attacks before pacemaker implantation; (3) patients with a history of transient ischemic attack, stroke, and myocardial infarction; (4) patients with chronic rheumatic valvular heart disease, congenital heart disease, or hypertrophic cardiomyopathy; (5) patients with a ventricular pacing lead implantation site not in the right ventricular septal plane (e.g., the right ventricular apex, His bundle area, or left bundle branch area) or an atrial pacing lead implantation site not in the right atrial appendage (e.g., the right atrial septal plane); and (6) patients who had a VVI pacemaker implanted during the operation due to the atrial lead pacing parameters not being ideal.

Pacemaker lead implantation methods: The fixed pacing leads were implanted through the subclavian vein or axillary vein. The ventricular pacing lead implantation site was the right ventricular septal plane, and the atrial pacing lead implantation site was the right atrial appendage. After the operation, the pacemaker was set to the DDD (R) mode, and the pacemaker's detecting, recording, and atrial arrhythmia storing functions were started. Medtronic pacemakers have a default AHRE frequency of 175 bpm, and Abbott pacemakers have a default rate of 180 bpm. After implantation, the Abbott pacemaker AHRE frequency was programmed to 175 bpm; during the follow-up, the pacemaker could indicate AHRE presence as well as the length of each event. An AHRE lasting ≥5 min was considered AHRE+; otherwise, it the AHRE was considered AHRE–.

Drug treatment after PPM implantation: If necessary, clinicians could freely choose renin-angiotensin system inhibitors (RAS-I) (e.g., angiotensin-converting enzyme inhibitors or angiotensin receptor blockers, β receptor blockers, and statins) or antiarrhythmic drugs (e.g., propafenone, amiodarone, sotalol, and diltiazem) for treatment, depending on whether the patient had complications of hypertension, coronary heart disease, diabetes, hyperlipidemia, or atherosclerosis.

Follow-up: The patients were followed up with for 12 months at 1 week after the operation and every 1–3 months after that. The specific follow-up included: (1) AHRE occurrence and the time from PPM implantation to the first AHRE occurrence; (2) the atrial pacing percentage (AP%) and ventricular pacing percentage (VP%); (3) AHRE type clarification via a 12-lead synchronous recording electrocardiography or 12-lead 24-h dynamic electrocardiography examination in patients with positive signs.

Research grouping: The patients were divided into two groups according to whether or not AHREs were detected by pacemakers during the follow-up: group A (AHRE+, n = 91) and group N (AHRE–, n = 198).

Statistical methods: All data analyses were based on the intention-to-treat analysis principle. Count data were expressed in percentage (%) and compared between the two groups using Pearson's Chi-square test or Fisher's exact test. Measurement data were first evaluated using a non-parametric test (Kolmogorov–Smirnov test); data in normal distribution were expressed as mean ± standard deviation and compared between the groups using t-tests, while data not in normal distributions were expressed as the median [25% percentile, 75% percentile, M[Q25, Q75]] and compared between the groups using non-parametric tests. The multivariate analysis was performed using logistic regression models, and the independent predictors of AHREs and endpoint events were analyzed and screened using Cox's proportional hazards model. The receiver operator characteristic (ROC) curve was used to find the best independent predictor diagnostic cut-off value, and the differences in post-operative AF-free and endpoint event-free survival time were analyzed using the Kaplan–Meier survival analysis and evaluated using log-rank (Mantel–Cox) tests. All data analyses were conducted using the SPSS software 26.0. A (two-sided) P-value of < 0.05 was considered statistically significant.

Results

A total of 308 patients who met the inclusion and exclusion criteria and completed the operation were included in the 12-month follow-up, which was completed by 289 patients; 19 patients [7 patients in group A and 12 patients in group N [P = 0.596]] either withdrew or were lost to the follow-up. Of these 289 patients, AHREs were detected in 91 [31.5%, 47 males [51.6%]], 76 of whom (83.5%) underwent 12-lead synchronous electrocardiography or 12-lead 24-h Holter after AHRE detection; of these, 71 (93.4%) were diagnosed with AF, atrial flutter (AFL), or both, and 3 (3.9%) were diagnosed with paroxysmal supraventricular tachycardia. An electrophysiological examination confirmed atrioventricular nodal re-entrant tachycardia, and a radiofrequency ablation was successfully carried out. A total of 2 patients (2.6%) had negative examination results.

Of the 289 patients who completed the follow-up, 91 were in group A and 198 were in group N. The patient age was significantly higher in group A (71.3 ± 9.5) than in group N (66.0 ± 11.7) (P < 0.001), and the symptomatic SSS diagnosis proportion was higher in group A (83.5%) than in group N (56.1%) (P < 0.001). There were no significant differences in other baseline data between the two groups (Table 1).

Table 1

GroupsGroup AGroup NP
(AHRE+, n = 91)(AHRE–, n = 198)
Age (year)71.9 ± 9.266.3 ± 11.70.000
Male (cases)47 (51.6%)103 (52.0%)0.953
BMI (kg m−2)23.3 (22.3–25.1)23.1 (21.4–25.1)0.302
DiagnosisAtrioventricular block (cases)15 (16.5%)87 (43.9%)0.000
Sinus node dysfunction (cases)76 (83.5%)111 (56.1%)
Hypertension (cases)44 (48.4%)91 (46.0%)0.705
Diabetes (cases)13 (14.3%)30 (15.2%)0.848
Coronary heart disease (cases)8 (8.8%)14 (7.1%)0.608
Peripheral vascular diseases (cases)3 (3.3%)3 (1.5%)0.324
History of TIA/stroke (cases)4 (4.4%)7 (3.5%)0.723
CHA2DS2-VASC score07 (7.7%)28 (14.1%)0.241
122 (24.2%)51 (25.8%)
>262 (68.1%)119 (60.1%)
NYHA cardiac function classification (cases)I56 (61.5%)144 (72.7%)0.234
II26 (28.5%)43 (21.7%)
III8 (8.8%)9 (4.5%)
IV1 (1.1%)2 (1.0%)
Pacemaker manufacturerAbbott47 (51.6%)114 (57.6%)0.346
Medtronic44 (48.4%)84 (42.4%)
Manufacturer of pacemaker checked byLVED (mm)49.2 ± 5.948.5 ± 4.60.277
transthoracic echocardiographyLVES (mm)31.3 (28.0–34.0)30.2 (27.8–32.8)0.173
LA (mm)38.0 (33.8–41.9)35.6 (32.8–38.9)0.009
LVPW (mm)9.8 (9.2–11.2)9.6 (8.9–10.4)0.046
IVS (mm)10.4 (9.4–11.8)10.1 (9.3–11.2)0.293
LVEF (%)66.2 (62.6–70.0)67.5 (62.2–71.2)0.231
LVWI (g m−2)110.8 (96.0–137.6)104.5 (95.0–119.7)0.023
E/E′13.2 (10.8–19.0)12.2 (10.0–15.6)0.080
E/A1.0 (0.8–1.4)0.9 (0.7–1.3)0.301

Comparison of baseline data of two groups before PPM implantation.

MI, body mass index; NYHA, New York Heart Association; LVED, left ventricular end-diastolic diameter; LVES, left ventricular end-systolic diameter; LA, left atrial diameter; LVPW, left ventricular posterior wall thickness; IVS, interventricular septal thickness; LVEF, left ventricular ejection fraction; LVWI, left ventricular mass index.

The left atrium was larger in group A [38.0 mm [33.8–41.9 mm]] than in group N [35.6 mm [32.8–38.9 mm]] (P = 0.009), the left ventricular posterior wall was thicker in group A [9.8 mm [9.2–11.2 mm]] than in group N [9.6 mm [8.9–10.4 mm]] (P = 0.046), and the left ventricular mass index was higher in group A [110.8 g/m2 [96.0–137.6 g/m2]] than in group N [104.5 g/m2 [95.0–119.7 g/m2]] (P = 0.023). There were no significant differences in the other transthoracic echocardiography parameters between the two groups (Table 1).

The AP% was higher in group A [68.0% [42.0–89.0%]] than in group N [38.5% [13.9–70.0%]] (P < 0.001). There was no difference in VP% between the two groups [8.3% [1.1–71.0%] in group A and 19.5% [2.2–97.8%] in group N] (P = 0.060, Table 2).

Table 2

GroupsGroup A (AHRE+,Group N (AHRE–,P
n = 91)n = 198)
Pacing rate after PPM
AP (%)68.0 (42.0–89.0)38.5 (13.9–70.0)0.000
VP (%)8.3 (1.1–71.0)19.5 (2.2–97.8)0.060
Drug use after PPM
ACE-I/ARB (cases)28 (30.8%)48 (24.2%)0.242
Post-operative use of β-receptor blockers (cases)33 (36.3%)28 (14.1%)0.000
Diltiazem4 (4.4%)13 (6.6%)0.466
CCB (cases)19 (20.9%)41 (20.7%)0.973
Post-operative use of statins (cases)43 (47.3%)86 (43.4%)0.544
Post-operative use of antiarrhythmic drugs (cases)18 (19.8%)12 (6.1%)0.005
Amiodarone107
Propafenone73
Sotalol12

Comparison of post-operative data between two groups after PPM.

AP, atrial pacing; VP, ventricular pacing; ACE-I, angiotensin converting enzyme inhibitor; ARB, angiotensin II receptor blocker; CCB, calcium channel blocker.

The proportion of patients who were treated with β-receptor blockers was higher in group A [33/91 [36.3%]] than in group N [28/198 [14.1%]] (P < 0.001), and the proportion of patients who were treated with an oral administration of antiarrhythmic drugs was higher in group A [18/91 [19.8%]] than in group N [12/198 [6.1%]] (P = 0.001). There were no significant differences in the proportions of patients who were treated with oral administration of RAS-I, calcium channel blockers, or statins between the two groups (Table 2).

The univariate logistic regression analysis revealed that patient age, diagnosis, left atrium size, left ventricular mass index, AP%, VP%, oral administration of β-receptor blockers, or Antiarrhythmic drugs (AADs) treatment were AHRE risk factors (Table 3), and the multivariate logistic regression analysis revealed that patient age [odds ratio [OR] = 1.060; 95% confidence interval [CI], 1.027–1.093; and P < 0.001], symptomatic SSS diagnosis (OR = 4.550; 95% CI, 1.634–12.669; and P = 0.004), AP% (OR = 1.018; 95% CI, 1.007–1.029; and P = 0.001), and oral administration of β-receptor blockers (OR = 2.520; 95% CI, 1.275–4.981; and P = 0.008) were AHRE risk factors (Table 4). The ROC curve analysis revealed that the best age diagnostic cut-off value was 65 years [area under the curve [AUC] = 0.641; sensitivity = 74.7%; specificity = 47.5%; and P < 0.001] and the best AP% diagnostic cut-off value was 53.5% (AUC = 0.692; sensitivity = 69.2%; specificity = 63.1%; and P < 0.001) (Table 5).

Table 3

BStandard errorWaldSignificanceExp (B)95% CI
Lower limitUpper limit
Gender0.0150.2530.0030.9530.9850.6001.619
Age0.0500.01314.8290.0001.0511.0251.078
BMI0.0200.0380.2710.6031.0200.9461.100
Diagnosis1.3790.31718.9560.0003.9712.1357.388
Hypertension0.0960.2540.1430.7051.1010.6701.810
Diabetes−0.0690.3590.0370.8480.9330.4621.887
Coronary heart disease0.2360.4630.2610.6091.2670.5123.136
History of TIA/stroke0.2270.6400.1260.2270.6400.1264.398
Peripheral vascular diseases0.7960.8270.9270.3362.2160.43911.197
CHA2DS2-VASc−0.3500.2681.7110.1910.7050.4171.191
NYHA0.3560.1893.5560.0591.4280.9862.069
LVED0.0270.0251.1820.2771.0280.9781.080
LVES0.0470.0263.3770.0661.0480.9971.103
LA0.0450.0214.5900.0321.0461.0041.089
LVPW0.1110.0831.7980.1801.1180.9501.315
IVS0.0520.0600.7370.3911.0530.9361.186
LVEF−0.0200.0171.3580.2440.9800.9471.014
LVWI0.0090.0044.4340.0351.0091.0011.017
E/E′0.0280.0201.9170.1661.0280.9881.070
E/A0.1330.2760.2340.6291.1420.6661.960
Pacemaker manufacturer0.2390.2540.8860.3461.2710.7722.092
AP0.0220.00425.0870.0001.0221.0141.031
VP−0.0060.0034.0960.0430.9940.9871.000
ACEI/ARB0.3220.2811.3090.2531.3800.7952.394
β-receptor blockers1.2400.29917.2400.0003.4541.9246.202
Statins0.1540.2540.3680.5441.1670.7091.920
CCB0.0100.3120.0010.9731.0110.5481.862
AAD1.3410.39711.3800.0013.8221.7548.329

Binary univariate logistic regression analysis of AHREs.

BMI, body mass index; NYHA, New York Heart Association; LVED, left ventricular end-diastolic diameter; LVES, left ventricular end-systolic diameter; LA, left atrial diameter; LVPW, left ventricular posterior wall thickness; IVS, interventricular septal thickness; LVEF, left ventricular ejection fraction; LVWI, left ventricular mass index; AP, atrial pacing; VP, ventricular pacing; ACE-I, angiotensin converting enzyme inhibitor; ARB, angiotensin II receptor blocker; CCB, calcium channel blocker; AAD, antiarrhythmic drugs.

Table 4

BStandard errorWaldSignificanceExp (B)95% CI
Lower limitUpper limit
Age0.0580.01613.4560.0001.0601.0271.093
Diagnosis1.5150.5238.4070.0044.5501.63412.669
AP0.0180.00510.5660.0011.0181.0071.029
VP0.0070.0051.8540.1731.0070.9971.018
NYHA0.0970.2630.1350.7141.1010.6581.845
LVES0.0150.0350.1900.6631.0150.9481.087
LA−0.0080.0270.0990.7530.9920.9411.045
LVWI0.0040.0060.3500.5541.0040.9921.016
β-receptor blockers0.9240.3487.0740.0082.5201.2754.981
AAD0.8010.4652.9740.0852.2280.8965.540

Binary multivariate logistic regression analysis of AHREs.

AP, atrial pacing; VP, ventricular pacing; ACE-I, angiotensin converting enzyme inhibitor; ARB, angiotensin II receptor blocker; CCB, calcium channel blocker; AAD, antiarrhythmic drugs.

Table 5

Test variableAreaStandardP95% CIThe best diagnostic
errorcut-off value
The area under the curve
Age0.6410.0340.0000.575–0.70865
AP0.6920.0320.0000.628–0.75553.5

ROC curve analysis of AHRE.

The Kaplan–Meier curve analysis revealed that after pacemaker implantation, patients with symptomatic SSS not only had a higher AHRE incidence but also an earlier AHRE occurrence (8.6 months) compared with patients with AVB (10.7 months) (P < 0.001, Table 6). The univariate Cox regression analysis revealed that patient age, diagnosis, AP%, and oral administration of β-receptor blocker therapy were risk factors for the AHRE-free duration after pacemaker implantation (Table 7). The multivariate Cox regression analysis revealed that patient age (OR = 1.041; 95% CI, 1.018–1.064; and P < 0.001), symptomatic SSS diagnosis (OR = 2.225; 95% CI, 1.227–4.036; and P = 0.008), AP% (OR = 1.010; 95% CI, 1.002–1.017; and P = 0.016), and oral administration of β-receptor blockers (OR = 1.569; 95% CI, 1.007–2.445; and P = 0.047) were risk factors for an early AHRE onset (Table 8).

Table 6

DiagnosisMeanMedian
EstimateStandard error95% CIEstimateStandard error95% CI
Lower limitUpper limitLower limitUpper limit
Mean and median survival analysis time
Atrioventricular block (cases)10.6720.34310.00011.345
Sick sinus syndrome (cases)8.5900.3307.9429.23711.0000.43010.15811.842
Overall9.2580.2568.7569.76011.0000.31310.38611.614

Kaplan–Meier analysis of AHREs.

Log rank test, X2 = 16.056, P < 0.0001.

Table 7

ItemsBSEWaldSignificanceExp (B)95% CI
Lower limitUpper limit
Gender−0.0150.2100.0050.9440.9850.6521.488
Age0.0360.01110.8060.0011.0371.0151.059
BMI0.0170.0310.2930.5881.0170.9561.082
Diagnosis1.0170.28312.9620.0002.7661.5904.812
Hypertension−0.1370.2130.4170.5190.8720.5741.323
Diabetes0.2150.3000.5120.4741.2400.6882.234
Coronary heart disease−0.2250.3730.3630.5470.7980.3841.660
History of TIA/stroke−0.1240.5120.0590.8080.8830.3242.408
Peripheral vascular diseases−0.1000.5930.0290.8660.9050.2832.891
CHA2DS2-VASc−0.0120.2280.0030.9590.9880.6331.544
NYHA0.2350.1482.5170.1131.2650.9461.691
LVED0.0150.0210.5290.4671.0150.9751.057
LVES0.0140.0200.5290.4671.0140.9761.054
LA0.0150.0150.9910.3191.0150.9861.045
LVPW0.1070.0692.3800.1231.1130.9721.274
IVS0.0420.0500.7030.4021.0420.9461.149
LVEF−0.0070.0150.1950.6590.9930.9651.023
LVWI0.0060.0033.4720.0621.0061.0001.013
E/E′0.0130.0150.8570.3551.0140.9851.043
E/A0.1670.2260.5450.4601.1820.7581.841
Pacemaker manufacturer−0.0050.2100.0010.9800.9950.6591.502
AP0.0130.00313.9810.0001.0131.0061.020
VP−0.0030.0031.1800.2770.9970.9921.002
ACEI/ARB0.0830.2310.1280.7201.0860.6911.707
β-receptor blockers0.6570.2189.0560.0031.9291.2582.960
Statins−0.1260.2110.3590.5490.8810.5831.332
CCB−0.0700.2580.0720.7880.9330.5621.548
AAD0.4820.2653.3040.0691.6190.9632.721
Endpoint event1.2650.4248.8890.0033.5441.5438.142

Univariate Cox's regression analysis of AHRE.

BMI, body mass index; NYHA, New York Heart Association; LVED, left ventricular end-diastolic diameter; LVES, left ventricular end-systolic diameter; LA, left atrial diameter; LVPW, left ventricular posterior wall thickness; IVS, interventricular septal thickness; LVEF, left ventricular ejection fraction; LVWI, left ventricular mass index; AP, atrial pacing; VP, ventricular pacing; ACE-I, angiotensin converting enzyme inhibitor; ARB, angiotensin II receptor blocker; CCB, calcium channel blocker; AAD, antiarrhythmic drugs.

Table 8

ItemsBSEWaldSignificanceExp (B)95% CI
Lower limitUpper limit
Age0.0400.01112.2140.0001.0411.0181.064
Diagnosis0.8000.3046.9320.0082.2251.2274.036
LVWI0.0030.0040.7190.3961.0030.9961.010
AP0.0090.0045.7800.0161.0101.0021.017
β-receptor blockers0.4500.2263.9570.0471.5691.0072.445
AAD0.1740.2760.3960.5291.1900.6932.043

Multivariate regression analysis of AHRE.

AP, atrial pacing; VP, ventricular pacing; ACE-I, angiotensin converting enzyme inhibitor; ARB, angiotensin II receptor blocker; CCB, calcium channel blocker; AAD, antiarrhythmic drugs.

Discussion

The results of the present study revealed a post-PPM-implantation AHRE incidence of 31.5%. Furthermore, patient age, symptomatic SSS diagnosis, PPM implantation, and AP% after PPM implantation were AHRE risk factors. Patients aged >65 years diagnosed with symptomatic SSS with a post-pacemaker-implantation AP% of ≥53.5% required follow-up. Once AHRE occurs, 12-lead synchronous electrocardiography or 12-lead 24-h Holter should be carried out for early AF detection and treatment.

AF is the most common persistent type of arrhythmia in adults; it is related to the increase in incidence and mortality rates of many diseases (2). Certain patients with AF are asymptomatic, which leads to clinical missed diagnoses. CIEDs with atrial leads can detect atrial arrhythmia events, including atrial tachycardia (AT), AFL, and AF. These events are usually asymptomatic and can only be detected by CIEDs through long-term continuous heart rate monitoring (8). Patients implanted with ICD, CRT-P, and CRT-D usually have underlying diseases, which will increase the incidence of atrial arrhythmia (1). Kleemann et al. (9) revealed that more than half of primary prophylactic ICD patients with sinus rhythm at baseline develop new AF or ventricular tachycardia or ventricular fibrillation after 6 years. Gonzales et al. (5) reported that previous heart failure was a AHRE predictor, and Wilton et al. (10) revealed that in trials on resynchronization in ambulatory heart failure, AF/AT after implantation of CRT/D was detected in nearly half of the patients after randomized grouping. Therefore, the present study only included patients with PPM implantation and excluded patients with ICD or CRT implantation.

At present, the AF prevalence in adults is 2–4%. With the increase in life expectancy and the widespread development of AF screening in the population, it is expected that the prevalence of AF will increase by 2.3 folds in the future (2). Patients with a previous history of AF were excluded from the present study. AHRE was detected in 91/289 patients who completed the 12-month follow-up. The AHRE incidence was 31.5%, which is similar to the incidence reported in relevant literature (8) but much higher than the AF prevalence in the general population. There are several possible reasons for this: (1) AF is diagnosed using electrocardiography; it is easy to miss the diagnosis when patients with paroxysmal AF are asymptomatic with a low frequency and short duration. AHRE is the result of continuous detection via CIEDs. Therefore, after CIED implantation, the AHRE detection rate is significantly higher than the AF detection rate (1); (2) most AHREs are asymptomatic or short-term AF, AFL, or AT. However, when other tachyarrhythmias, such as sinus tachycardia, paroxysmal supraventricular tachycardia, or ventricular tachycardia with 1:1 atrioventricular retrograde conduction, reach the AHRE diagnostic criteria (atrial rate ≥ 175 bpm, duration ≥ 5 min), they will be diagnosed as AHREs by the CIEDs. Most studies use ≥5 min to define AHRE; however, they have a false-positive rate of 17.3% (11); and (3) a false-positive AHRE diagnosis can also be caused by atrial pacing lead over sensing, far-field R wave sensing, pacing lead-mediated arrhythmia, or other external signal interferences (12). Although Bertaglia et al. (8) believe that AHREs lasting >5–6 min are the “diagnostic sweet spot,” it enables most AHRE detection algorithms to distinguish real atrial arrhythmia from external signal interference. The results of the present study confirmed that AHRE-positive patients mostly had AF/AFL; however, the diagnosis may also be a false positive or SVT and other tachyarrhythmias, and AHRE-positive patients cannot be simply considered to have AF/AFL. Further surface electrocardiography or Holter examinations should be performed to eliminate false positives.

Age is not only the most important risk factor of AF (2), but also AHRE (6). In the present study, the patient age was significantly higher in group A than in group N. The multivariate logistic regression analysis revealed that patient age (OR = 1.060; 95% CI, 1.027–1.093; and P < 0.001) was an AHRE risk factor; the older the patient, the higher the risk of AHRE. The ROC curve analysis revealed that the best diagnostic cut-off value was 65 years (AUC = 0.641; sensitivity = 74.7%; specificity = 47.5%; and P < 0.001).

Both sinoatrial nodal dysfunction (SND) and AF are associated with atrial remodeling. The common pathological change is atrial fibrosis, which results in an extensive low voltage area and slow conduction velocity in the atrium (13). A recent study revealed that Paired-like homeodomain 2, the first common AF gene locus, is not only involved in the development of the pulmonary vein (14) but also related to the development of sinoatrial nodes and the asymmetry of the right and left atrium (15). Among patients with SND, 40–70% have atrial arrhythmias, such as AF (15). The results of the ASSERT (The Asymptomatic Atrial Fibrillation and Stroke Evaluation in Pacemaker Patients and the Atrial Fibrillation Reduction Atrial Pacing Trial) (3) revealed that SND and the resting heart rate decrease were AHRE predictors. In their study, Kim et al. (16) enrolled 880 patients with pacemaker implants and no previous history of AF and followed up with them for 7 years. The results revealed a new AF onset in 122 (13.8%) patients. Moreover, the diagnosis of symptomatic SSS and pacemaker implantation were independent risk factors for AF (HR = 2.33; 95% CI, 1.62–3.55; and P < 0.001). Kim et al. (11) reported a correlation between symptomatic SSS and AHREs with a duration of >6 min (OR = 3.85; 95% CI, 2.42–6.14; and P < 001). The results of the present study revealed that the proportion of patients with pacemaker implantation due to symptomatic SSS was higher in group A (83.5%) than in group N (56.1%) (P < 0.001). The multivariate logistic regression analysis revealed that pacemaker implantation based on a symptomatic SSS diagnosis was an AHRE risk factor (OR = 4.550; 95% CI, 1.634–12.669; and P = 0.004); this is consistent with the results of Kim et al. (16) and supports the view that symptomatic SSS is closely related with AHRE.

Atrial pacing increases the occurrence of AHREs; Adelstein and Saba (17) revealed that, after CRT implantation, the risk of AF increased 2 folds in patients with atrial pacing than in patients with atrial perception. Fontenla et al. (18) reported that atrial rate-responsive pacing increased the incidence of persistent AF/AT in patients with ICD implants (OR = 3.58; 95% CI, 1.82–7.03; and P < 0.001). In the present study, the AP% was significantly higher in group A than in group N. The multivariate logistic regression analysis revealed that AP% (OR = 1.010; 95% CI, 1.002–1.017; and P < 0.016) was an AHRE risk factor; the higher the AP%, the higher the risk of AHRE. The ROC curve analysis revealed that the best AP% diagnostic cut-off value was 53.5% (AUC = 0.692; sensitivity = 69.2%; specificity = 63.1%; and P < 0.001).

A previous study revealed that left atrial enlargement was not only closely related to the occurrence and development of AF but also a predictor of AF recurrence after radiofrequency ablation (19). Atrial enlargement is accompanied by different degrees of atrial fibrosis, and that atrial fibrosis may be an important characteristic of persistent AF (19). Kim et al. (11) revealed that left atrium enlargement (>41 mm) was associated with AHRE occurrence (OR = 1.96; 95% CI, 1.00–3.85; and P = 0.050). The present study also revealed that the left atrium was significantly larger [38.0 mm [33.8–41.9 mm]] in group A than in group N [35.6 mm [32.8–38.9 mm]] (P = 0.009). These results suggest that left atrial enlargement is closely related with AHRE occurrence. A number of clinical diseases (e.g., hypertension, coronary heart disease, heart failure, cardiomyopathy, obesity, and diabetes) can induce atrial fibrosis; this suggests that in AF treatment, attention should also be paid to comprehensively treating patient complications. This is consistent with the guidelines' treatment path (2).

The results of the present study suggest that the proportion of patients who underwent an oral administration of β-receptor blockers or had AADs (or both) was significantly higher in group A than in group N (P < 0.001). This may be due to the occurrence of AHRE-induced clinical symptoms, such as palpitations and chest tightness, in group A, and clinicians prescribing more of the above-stated drugs, such as amiodarone, propafenone and sotalol, for treatment, so, AHRE is the cause of using AADs or β-receptor blockers.

The present study has the following limitations: (1) it is a single-center retrospective case study, the sample size is small, and there may be a certain degree of bias; (2) cases of CRT or ICD implantation were excluded and, thus, the AHRE detection rate may be underestimated; (3) it has a 12-month follow-up period and does not involve the incidence of stroke, systemic embolism, heart failure, acute myocardial infarction, and other cardiovascular and cerebrovascular events within 12 months of pacemaker implantation. In the follow-up study, we will explore the direct correlation between AHREs and clinical cardiovascular and cerebrovascular events, along with the risk factors.

Funding

This research was supported by the Guiding project of Fujian science and Technology Department (No: 2017Y0039).

Publisher's Note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Statements

Data availability statement

The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.

Ethics statement

This study was conducted with approval from the Ethics Committee of Fujian Medical University Union Hospita (No:2021KY047). The patients/participants provided their written informed consent to participate in this study.

Author contributions

HZ, QC, and FF conceived the idea and conceptualized the study. FZ, LC, and WW collected the data. HZ analyzed the data. JC, GC, and WW drafted and reviewed the manuscript. All authors read and approved the final draft.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

References

  • 1.

    KhanAABorianiGLipGYH. Are atrial high rate episodes (AHREs) a precursor to atrial fibrillation?Clin Res Cardiol. (2020) 109:40916. 10.1007/s00392-019-01545-4

  • 2.

    HindricksGPotparaTDagresNArbeloEBaxJJBlomström-LundqvistCet al. 2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS): the Task Force for the diagnosis and management of atrial fibrillation of the European Society of Cardiology (ESC) Developed with the special contribution of the European Heart Rhythm Association (EHRA) of the ESC. Eur Heart J. (2021) 42:373498. 10.1093/eurheartj/ehaa612

  • 3.

    HealeyJSConnollySJGoldMRIsraelCWVan GelderICCapucciAet al. Subclinical atrial fibrillation and the risk of stroke. N Engl J Med. (2012) 366:1209. 10.1056/NEJMoa1105575

  • 4.

    BorianiGGlotzerTVSantiniMWestTMDe MelisMSepsiMet al. Device-detected atrial fibrillation and risk for stroke: an analysis of >10,000 patients from the SOS AF project (Stroke prevention Strategies based on Atrial Fibrillation information from implanted devices). Eur Heart J. (2014) 35:50816. 10.1093/eurheartj/eht491

  • 5.

    GonzalezMKeatingRJMarkowitzSMLiuCFThomasGIpJEet al. Newly detected atrial high rate episodes predict long-term mortality outcomes in patients with permanent pacemakers. Heart Rhythm. (2014) 11:221421. 10.1016/j.hrthm.2014.08.019

  • 6.

    PastoriDMiyazawaKLiYShahidFHadoHLipGYH. Inflammation and the risk of atrial high-rate episodes (AHREs) in patients with cardiac implantable electronic devices. Clin Res Cardiol. (2018) 107:7727. 10.1007/s00392-018-1244-0

  • 7.

    EpsteinAEDiMarcoJPEllenbogenKAEstesNAFreedmanRAGettesLSet al. ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices) developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons. J Am Coll Cardiol. (2008) 51:e162. 10.1016/j.jacc.2008.02.032

  • 8.

    BertagliaEBlankBBlomström-LundqvistCBrandesACabanelasNDanGAet al. Atrial high-rate episodes: prevalence, stroke risk, implications for management, and clinical gaps in evidence. Europace. (2019) 21:145967. 10.1093/europace/euz172

  • 9.

    KleemannTStraussMKourakiKWernerNZahnR. Prognostic relevance of new onset arrhythmia and ICD shocks in primary prophylactic ICD patients. Clin Res Cardiol. (2020) 109:8995. 10.1007/s00392-019-01491-1

  • 10.

    WiltonSBExnerDVWyseDGYetisirEWellsGTangASet al. Frequency and outcomes of postrandomization atrial tachyarrhythmias in the resynchronization/defibrillation in ambulatory heart failure trial. Circ Arrhythm Electrophysiol. (2016) 9:e003807. 10.1161/CIRCEP.115.003807

  • 11.

    KimMKimTHYuHTChoiEKParkHSParkJet al. Prevalence and predictors of clinically relevant atrial high-rate episodes in patients with cardiac implantable electronic devices. Korean Circ J. (2021) 51:23547. 10.4070/kcj.2020.0393

  • 12.

    LimHSLipGY. Asymptomatic atrial fibrillation on device interrogation. J Cardiovasc Electrophysiol. (2008) 19:8913. 10.1111/j.1540-8167.2008.01194.x

  • 13.

    LeeJMKalmanJM. Sinus node dysfunction and atrial fibrillation: two sides of the same coin?Europace. (2013) 15:1612. 10.1093/europace/eus223

  • 14.

    LeeJYKimTHYangPSLimHEChoiEKShimJet al. Korean atrial fibrillation network genome-wide association study for early-onset atrial fibrillation identifies novel susceptibility loci. Eur Heart J. (2017) 38:258694. 10.1093/eurheartj/ehx213

  • 15.

    HwangTHYuHTKimTHUhmJSKimJYJoungBet al. Permanent pacemaker implantations after catheter ablation in patients with atrial fibrillation associated with underlying sinus node dysfunction. Korean Circ J. (2020) 50:34657. 10.4070/kcj.2019.0268

  • 16.

    KimBSChunKJHwangJKParkSJParkKMKimJSet al. Predictors and long-term clinical outcomes of newly developed atrial fibrillation in patients with cardiac implantable electronic devices. Medicine. (2016) 95:e4181. 10.1097/MD.0000000000004181

  • 17.

    AdelsteinESabaS. Right atrial pacing and the risk of postimplant atrial fibrillation in cardiac resynchronization therapy recipients. Am Heart J. (2008) 155:949. 10.1016/j.ahj.2007.08.030

  • 18.

    FontenlaASalgueroRMartinez-FerrerJBRodriguezAAlzuetaJGarciaEet al. Atrial rate-responsive pacing and incidence of sustained atrial arrhythmias in patients with implantable cardioverter defibrillators. Pacing Clin Electrophysiol. (2016) 39:54856. 10.1111/pace.12856

  • 19.

    DengHBaiYShantsilaAFauchierLPotparaTSLipGYH. Clinical scores for outcomes of rhythm control or arrhythmia progression in patients with atrial fibrillation: a systematic review. Clin Res Cardiol. (2017) 106:81323. 10.1007/s00392-017-1123-0

Summary

Keywords

atrial high-rate events, pacemaker, sick sinus syndrome, percentage of atrial pacing, cardiology

Citation

Chen JH, Chen GY, Zheng H, Chen QH, Fu FY, Zhang FL, Chen LL and Wang WW (2021) Atrial High-Rate Event Incidence and Predictors in Patients With Permanent Pacemaker Implantation. Front. Cardiovasc. Med. 8:728885. doi: 10.3389/fcvm.2021.728885

Received

22 June 2021

Accepted

23 August 2021

Published

11 October 2021

Volume

8 - 2021

Edited by

Hung-Fat Tse, The University of Hong Kong, Hong Kong, SAR China

Reviewed by

Yasushi Oginosawa, University of Occupational and Environmental Health Japan, Japan; Young Keun On, Sungkyunkwan University, South Korea

Updates

Copyright

*Correspondence: Wei Wei Wang

This article was submitted to Cardiac Rhythmology, a section of the journal Frontiers in Cardiovascular Medicine

Disclaimer

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Outline

Cite article

Copy to clipboard


Export citation file


Share article

Article metrics