Corrigendum: Protein and Organic-Molecular Crystallography with 300kV Electrons on a Direct Electron Detector

  • 1. Biostructural Mechanism Laboratory, RIKEN SPring-8 Center, Sayo, Japan

  • 2. Department of Applied Physics, The University of Tokyo, Tokyo, Japan

  • 3. Advanced Electron Microscope Development Unit, RIKEN-JEOL Collaboration Center, RIKEN Baton Zone Program, Sayo, Japan

  • 4. Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Sendai, Japan

Article metrics

View details

2,3k

Views

522

Downloads

In the original article, there was an error in the Summary and Perspectives. It was indicated that radiation damage caused by single 300 kV electron is reduced to 96 and 25%, compared with 100 and 200 kV, respectively. In fact, the correct values are by 49 and 20%. A correction has been made to the Summary and Perspectives section, paragraph 2.

“Radiation damage is serious in both X-ray analysis and cryo-EM, and previous studies observed that even a small amount of electron irradiation caused breaks of cysteine bonds (Hattne et al., 2018, 2019) and reduction of metal (Yonekura et al., 2015) in protein crystals. The radiation damage caused by single 300 kV electron is reduced by 49 and 20%, compared with 100 and 200 kV, respectively (Yonekura et al., 2019). Deposited energy with single 300 kV electron/Å2 was calculated to 5.6 × 106 Gy (J/kg) for water (ICRU, 2014; Yonekura et al., 2019), where Gy is a standard unit in X-ray crystallography and related areas. Henderson limit, a criterion for a tolerable energy deposition on biological samples and widely used in X-ray crystallography, is ∼2 × 107 Gy (Henderson, 1990). The catalase structure here was obtained from a maximum exposure of 3.5 × 106 M Gy for single dataset (Table 1), and this is 1/5.7 of Hendrson limit. Thus, our system would be suitable for electron 3D crystallography with less damaging, a smaller point spread, and less noise than using the scintillator coupled camera.”

The authors apologize for this error and state that this does not change the scientific conclusions of the article in any way. The original article has been updated.

Statements

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Summary

Keywords

DE64, energy filter, electron 3D crystallography (3D ED/MicroED), eEFD, CRYO ARM

Citation

Takaba K, Maki-Yonekura S, Inoue S, Hasegawa T and Yonekura K (2021) Corrigendum: Protein and Organic-Molecular Crystallography with 300kV Electrons on a Direct Electron Detector. Front. Mol. Biosci. 8:749448. doi: 10.3389/fmolb.2021.749448

Received

29 July 2021

Accepted

05 August 2021

Published

18 August 2021

Volume

8 - 2021

Edited and reviewed by

Dan Shi, Center for Cancer Research, United States

Updates

Copyright

*Correspondence: Koji Yonekura,

This article was submitted to Structural Biology, a section of the journal Frontiers in Molecular Biosciences

Disclaimer

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Outline

Cite article

Copy to clipboard


Export citation file


Share article

Article metrics