ORIGINAL RESEARCH article
Front. Oncol.
Sec. Breast Cancer
Comparison of Diagnostic Performance Between Contrast-Enhanced Mammography and Breast Magnetic Resonance Imaging
Provisionally accepted- Wuhan Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
Select one of your emails
You have multiple emails registered with Frontiers:
Notify me on publication
Please enter your email address:
If you already have an account, please login
You don't have a Frontiers account ? You can register here
Objective: Contrast-enhanced mammography (CEM) is an emerging imaging technique. This study aims to compare the diagnostic accuracy of CEM and magnetic resonance imaging (MRI) for breast lesions. Methods: A retrospective analysis was conducted on patients who underwent both CEM and MRI at our institution from July 2019 to April 2024. All imaging reports were prepared in accordance with the Breast Imaging Reporting and Data System (BI-RADS) guidelines established by the American College of Radiology (ACR). The final diagnosis was established using pathology as the "gold standard." The diagnostic performance of the two methods in detecting breast lesions was compared using sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV), and receiver operating characteristic (ROC) curves. Results: A total of 292 patients underwent paired CEM and MRI examinations, with an average age of 46.9 years. Among the 301 breast lesions identified, 121 (40.2%) were benign, and 180 (59.8%) were malignant. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of CEM for diagnosing benign and malignant breast lesions were 98.9%, 78.5%, 90.7%, 87.3%, and 97.9%, respectively. The corresponding values for MRI were 98.9%, 72.7%, 88.4%, 84.4%, and 97.8%. No significant difference was observed in the diagnostic performance between the two methods (p > 0.05). The areas under the curve (AUC) for CEM and MRI were 0.887 (95% CI: 0.85–0.92) and 0.858 (95% CI: 0.81–0.90), respectively (p = 0.400). Conclusion: As an emerging imaging technique for detecting and diagnosing breast lesions, CEM demonstrates diagnostic performance comparable to that of MRI.
Keywords: breast cancer, contrast-enhanced mammography, Diagnostic performance, Magnetic Resonance Imaging, Mammography
Received: 09 Jan 2025; Accepted: 03 Dec 2025.
Copyright: © 2025 Yang and Yang. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
* Correspondence: Fan Yang
Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.