CORRECTION article

Front. Endocrinol., 16 November 2020

Sec. Pediatric Endocrinology

Volume 11 - 2020 | https://doi.org/10.3389/fendo.2020.614734

Corrigendum: Efficacy of Dose-Titrated Glucagon Infusions in the Management of Congenital Hyperinsulinism: A Case Series

  • 1. Department of Paediatric Endocrinology, Royal Manchester Children’s Hospital, Manchester, United Kingdom

  • 2. Faculty of Biology, Medicine and Health, University of Manchester, Manchester, United Kingdom

  • 3. Department of Statistics, Zealand Pharma A/S, Søborg, Denmark

  • 4. Medical Publications, rareLife solutions, Norwalk, CT, United States

In the original article, there was a mistake in Figure 1 and its caption as published.

Figure 1

In the figure, the “>” symbols should be “≥”.

In the legend, the last sentence should read “…if glucose concentration is ≥ 6.0 mmol/L, …”.

The correct Figure 1 and legend appear below.

In the original article, there was a mistake in Figure 2 and its caption as published.

Figure 2

In the figure, the Y-axis label incorrectly included “change”. Also, the X-Axis had a typo; the righthand tic mark should be GIR2 instead of GIR1.

In the legend “Mean Change in GIR after achieving glycemic stability (all patients)” was incorrect and should have read “Mean GIRs at two time points, 24 h apart, after achieving glycemic stability in all patients”.

The correct Figure 2 and legend appear below.

In the original article, there was a mistake in the Supplementary Figure 1 and its caption as published.

In the figure, the criteria for Dextrose Infusion, and Glucagon Infusion have incorrect “>” symbols before 3.5 mmol/L and should be “≥”.

In the legend, the same error occurred.

The correct Supplementary Figure 1 and legend appear below.

Supplementary Figure 1

Text Corrections

In the original article, a few typos were noted.

In Methods, Concomitant Medications,Paragraph 3, the incorrect symbol “>” should have read “≥”. The correct text appears below:

The principle of clinical management was to achieve glycemic stability and prevent hypoglycemia in the shortest possible time to minimize the long-term risk of neuroglycopenia. The protocol allowed for clinician-dependent decisions for dextrose infusions and diazoxide/octreotide dosing in the glucagon titration period leading up to the glucose stable period. Following the achievement of glucose stability, GIR reduction was allowed if the clinician (pediatric endocrinologist) perceived a low risk of hypoglycemia. A low risk was deemed for plasma glucose concentrations ≥ 6 mmol/L.

In Methods, Intervention: Glucagon Infusion Protocol, Paragraph 2, the incorrect symbol “>” should have read “≥”. The correct text appears below:

The dose of glucagon was drawn up and diluted with 0.9% sodium chloride solution to make up to 5ml in a 10ml syringe to give an initial rate of 0.2 ml/h equating to 5 μg/kg/h. Glucagon solutions were changed every 12 h due to glucagon instability in prepared solutions. Glucagon was delivered via peripheral intravenous (IV) infusion in the majority, with hourly plasma glucose monitoring by uniform point of care testing (Nova Biomedical Inc). The titration strategy was to achieve plasma glucose concentrations ≥ 3.5 mmol/L while ensuring that the total fluid volume remained ≤ 150 mL/kg/day to prevent fluid overload. If glucose concentrations fell below 3.5 mmol/L, an IV bolus of 10% dextrose (2 mL/kg) was administered. The dose of glucagon was reviewed every 4 h.

In Methods, Study endpoints, Paragraph 1, the incorrect term “compromised” should have read “comprised”. The correct text appears below:

The rate of dextrose infusion in ml/kg/day was recorded as the GIR. GIR was comprised of the total dextrose administered, including IV dextrose, parenteral nutrition and enteral intake where applicable. Glycaemic stability was defined as hourly serial plasma glucose concentrations ≥ 3.5 mmol/L for 24 h. The GIR at the end of this 24-h period was defined as GIR1.**

In Methods, Study endpoints, Paragraph 2, the incorrect symbol “>” should have read “≥”. The correct text appears below:

Reduction of IV GIR (keeping enteral GIR stable) was attempted in the following 24-h period, and this was recorded as GIR2. GIR reduction was at the clinician’s discretion; the degree and/or rate of GIR reductions were not stipulated by center guidelines but a reduction in GIR was suggested if risk of hypoglycemia was deemed to be low (plasma glucose ≥ 6 mmol/L).

In Methods, Study endpoints, Paragraph 3, the incorrect symbol “>” should have read “≥”. The correct text appears below:

The highest dose of glucagon (μg/kg/hour) required to prevent hypoglycemia (defined as plasma glucose < 3.5 mmol/L, measured by 1-h point-of-care testing) during the glucagon titration period was recorded. The goal for this treatment regimen was to keep the patient’s plasma glucose concentrations ≥ 3.5 mmol/L. The first end point of the study was to demonstrate glycemic stability by dose-titrated glucagon and the second end point was to demonstrate a reduction in GIR.

In Results, Mutation Status, Paragraph 1, the terms “to the conduct of” were missing. The correct text appears below:

Since mutation status was not available at the time of treatment, all therapeutic approaches employed in this study were “mutation status blind.” Subsequent to the conduct of the clinical treatment of the patients, a genetic cause of CHI due to mutations in the ATP-sensitive K+ channel subunits (KCNJ11 and ABCC8) was identified in 10 patients.Of the 6 patients with monoallelic mutations, 5 had focal CHI and underwent focal lesionectomy.

In Results, Treatments, Paragraph 2, the incorrect value “15.5” should have read “15.6”. The correct text appears below:

Glycaemic stabilization by glucagon titration led to a reduction in the GIR from 15.6 (4.5) to 13.4 (4.5) mg/kg/min (p = 0.000019 for difference; paired t-test) within 24 h in the 32 patients for whom paired GIR1 and GIR2 values were available (Figure 2). GIR reduced in 18 (56.2%) patients, but no change in the GIR was reported in 14 (43.8%) patients.

The authors apologize for these errors and state that they do not change the scientific conclusions of the article in any way. The original article has been updated.

Summary

Keywords

glucose, congenital hyperinsulinism, hypoglycemia, glucagon infusion, dose titration

Citation

Salomon-Estebanez M, Yau D, Dunne MJ, Worth C, Birch S, Walewski JL and Banerjee I (2020) Corrigendum: Efficacy of Dose-Titrated Glucagon Infusions in the Management of Congenital Hyperinsulinism: A Case Series. Front. Endocrinol. 11:614734. doi: 10.3389/fendo.2020.614734

Received

07 October 2020

Accepted

13 October 2020

Published

16 November 2020

Volume

11 - 2020

Edited and reviewed by

Fabrizio Barbetti, University of Rome Tor Vergata, Italy

Updates

Copyright

*Correspondence: Indraneel Banerjee,

This article was submitted to Pediatric Endocrinology, a section of the journal Frontiers in Endocrinology

Disclaimer

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Outline

Figures

Cite article

Copy to clipboard


Export citation file


Share article

Article metrics