Abstract

In this article, the power generation of a concentrated space solar power station (SSPS) is enhanced by current-injected total-cross-tied (TCT-CI) photovoltaic (PV) array. First, a mathematical model of the TCT-CI–connected PV array is established. Second, PV arrays with several common topologies and TCT-CI topology are simulated and analyzed using MATLAB/Simulink. At last, comparative experiments are conducted for TCT and TCT-CI–connected PV arrays under the condition of non-uniform light intensity distribution. The results of the above indicate the following: 1) TCT-CI–connected PV arrays reduce the difficulty of MPPT in concentrated SSPS, 2) TCT-CI–connected PV arrays increase the power generated in concentrated SSPS, and 3) TCT-CI–connected PV arrays are applicable for concentrated SSPS.

1 Introduction

Energy resources in the world are becoming increasingly scarce with the development of world economy and increase in population. In this scenario, new energy has received extensive attention. Solar energy has a broader application prospect because it is pollution free, is inexhaustible, and has inexhaustible characteristics. Photovoltaic (PV) arrays at the ground are affected by climatic changes, day and night, geographical environment, and other factors, resulting in reduced power generation. In order to solve the disadvantages of PV power generation at ground level, researchers are beginning to focus on power generation from space—the space solar power station (SSPS) (Xja et al., 2021).

At present, researchers have proposed a variety of conceptual schemes of SSPS. These schemes can be divided into two types according to the form of sunlight collection by SSPS. The first type is the non-concentrated type, that is, sunlight directly shines on the photovoltaic array. This type includes the 1979 SPS Reference Concept, the “SunTower” SPS system (Mankins, 2002), Tethered-SPS (Sasaki et al., 2007), and such others. The second type is the concentrated type (Jin et al., 2016); due to the high cost of PV cells, researchers have proposed the concentrated type to reduce the area of the PV arrays. In the concentrated-type SSPS, sunlight shines on the photovoltaic array after the concentrator. This type includes SPS-ALPHA (MANKINS, 2013), integrated symmetrical concentrated architecture (ISC) (Jin and Huang, 2018), and SSPS-OMEGA (Fan et al., 2020).

Due to the structural characteristics and manufacturing errors of the concentrated SSPS, the light intensity distribution on the solar receiver is not uniform. The non-uniform light intensity distribution can cause mismatch losses, reduce power generation, cause hot spot problems, and even cause damage to the PV array (Alanazi et al., 2022). Uneven light intensity distribution reduces the performance of PV arrays, which affects the power generation of SSPS. Now, we have to find a method suitable for SSPS to improve the performance of photovoltaic arrays under non-uniform light intensity distribution.

To reduce the impact of non-uniform light intensity distribution on PV arrays, many methods have been proposed.

The first method uses a different PV array topology. Instead of the traditional series–parallel (SP) configuration, new structures such as BL, HC, and TCT are adopted. In Jazayeri et al. (2014), under the SP, BL, and TCT configurations, PSCs were simulated using MATLAB/Simulink. In ElyaqoutiIzbaimBouhouch (2021), the electrical behavior of S, parallel (P), SP, TCT, BL, and HC connected PV arrays under different PSCs. The aforementioned literature shows that TCT PV array performs the best among several common configurations under non-uniform irradiation.

The second method is PV array reconfiguration (PVAR), which is based on the TCT topology (Qi, 2022). This method can be divided into two types, namely, static PVAR (SPVAR) and dynamic PVAR (DPVAR) (Krishna and Moger, 2018; Storey et al., 2014). DPVAR changes the electrical connection between PV modules to adapt to non-uniform light intensity distribution (Bularka and Gontean, 2017; Wang et al., 2012; Matam and Barry, 2018), whereas SPVAR changes the physical position of PV panels to create a uniform light intensity distribution (RaniIlango and Nagamani, 2013; Sahu and Nayak, 2016).

SPVAR requires rearranging the positions of the PV panels, which consumes a large number of transmission wires. DPVAR does not change the physical positions of the PV panels but relies on the switch matrix to change the electrical connection relationship until the optimal connection mode is found (NahidanNiroomand and Dehkordi, 2021).

In the concentrated SSPS, the physical position of the PV modules is fixed. Therefore, SPVAR cannot be applied here. Because DPVAR makes the system more expensive and complex (Belhachat and Larbes, 2021), this method is also unsuitable for concentrated SSPS.

In order to maximize the power generated, the maximum power point tracking (MPPT) method is required. The non-uniform light intensity distribution causes multiple peaks in the power–voltage (PV) curve of the PV array (Ahmad et al., 2017; Awan et al., 2022). Conventional MPPT algorithms, such as P&O (Salameh and Taylor, 1990; SantosAntunes et al., 2006) and conductance increment method (INC) (ElgendyZahawi and Atkinson, 2013; Liu et al., 2008), can usually only find the first peak close to the starting point of the PV curve. When light intensity distribution is non-uniform, it is possible that the first peak is the local MPP but not global MPP (GMPP) (Titri et al., 2017). To make the MPPT algorithm more accurate, smarter but complex MPPT control algorithms have been proposed, such as the gray wolf algorithm improved by the Levy flight (WangCai and Zeng, 2021), ant colony algorithm (ACO) (Chao and Rizal, 2021), hybrid global MPPT searching method (Rizzo and Giacomo, 2021), and genetic algorithm (GA) (Mohammad et al., 2015). Although the GMPP can be tracked using the aforementioned algorithm, this increases the difficulty and time of MPPT.

To increase the output power of PV arrays in concentrated SSPS and reduce the difficulty of MPPT, the current injection TCT (TCT-CI) topology has been applied in this study. In the TCT-CI–connected PV array, each row is parallel with a controllable current source. Without considering the effect of light intensity from the PV module output voltage, each PV module can be operated at its GMPP.

In this article, Section 2 performs mathematical modeling on the PV cell and TCT-CI–connected PV array. Section 3 describes the evaluation method of PV array performance. Section 4 discusses and compares simulation results of the TCT-CI–connected PV array and other PV array configurations. In Section 5, comparative experiments are conducted for TCT and TCT-CI–connected PV arrays. Finally, Section 6 summarizes this whole article.

2 Mathematical modeling

PV arrays are connected by many PV cells. Commonly used PV cell models are single-diode models (Hasan and Parida, 2016).

As shown in Figure 1, the relationship between and (Mehta et al., 2019; Sai Krishna and Moger, 2019) is defined aswhere Iph is the light generated current; is the diode’s reverse saturation current; is the electric charge on an electron, which is equal to 1.602176487*10−19; is the ideality factor; is the Boltzmann’s constant, which is equal to 1.3806504*10−23; is temperature in Kelvin, is series resistance, and is shunt resistance. is the short-circuit current at the standard test condition (STC).

FIGURE 1

FIGURE 1

Model of a PV cell.

is proportional to solar irradiation(G) and temperature (), which is defined aswhere is the temperature coefficient of ; G0 is the light intensity under STC; TSTC is temperature under STC.

Parameters of the PV model used in Section 3/Simulink are shown in Table 1 and the PV curves are shown in Figure 2.

TABLE 1

ParameterValue
(W)83.2848
Ncell(cells per module)20
Voc(V)12.64
Isc(A)8.62
Vm(V)10.32
Im(A)8.07
Rsh(ohms)82.1161
Rs(ohms)0.098625

Parameters of the PV model using Simulink.

FIGURE 2

FIGURE 2

Characteristic curves for different irradiance levels. (A) I-V Curves, (B) P-V Curves.

According to the and relationship, under constant temperature, is approximately proportional to the light intensity and is approximately logarithmic to . In concentrated SSPS, when PV modules are deployed, the same row of PV modules in the TCT-CI connected PV array are on the same horizontal line of the solar receiver. The light intensity distribution and temperature of PV modules in the same row is approximately the same, therefore the output voltages of PV modules in the same row are assumed to be the same.

When the temperature is constant, and are functions of . In an PV array (Figure 3), the light intensity on the module is , and then and at the GMPP of the module are expressed as follows:In the TCT-CI topology, the output current in row at GMPP isand the output voltage in row at GMPP isWhen the photoelectric effect of the PV modules in row is weaker than that in other rows, the relative is smaller. The parallel controlled current source operates in row and injects current into it, such that its output current is equal to that in the other rows.

FIGURE 3

FIGURE 3

PV arrays with TCT-CI topology.

Under the action of controllable current sources, the output current of the array () isand the output voltage () is

The output current of the controllable current source in row () is

The total output power of controllable current sources is

The output power of the array is

In practical applications, is obtained by measuring the currents of the bypass diodes and the output current of the array when the current injection section is not started.

According to Eqs 810, when the PV array has a TCT-CI topology, the working current of each row is the current at the GMPP, and there is no mismatch loss.

3 Evaluation of the PV array

When the irradiation is not uniform, the performance of the PV array can be evaluated from GMPP, mismatch power loss (MPL), power loss (PL), filling factor (FF), and efficiency ().

3.1 Mismatch power loss

MPL refers to the difference between the sum of the maximum power of all PV modules in the PV array and the maximum power of the PV array under non-uniform light intensity. MPL can be determined as

The larger the MPL, the greater is the influence of the output power of the PV array with non-uniform irradiation.

3.2 Power loss

PL represents the difference between the global maximum power of the PV array under STC (1,000 W/m2, AM1.5, 25°C) and that under non-uniform light intensity distribution. PL can be determined as

Because the irradiation on the PV array in concentrated SSPS is not uniform, MPL is used in this study to measure the effectiveness of various configurations.

3.3 Filling factor

The product of and is the limit of the output power of the PV module. The ratio of the product of and to the global maximum power () is defined as the filling factor (FF).

The larger the FF, the higher is the output power and efficiency of the photovoltaic module. FF affects the output efficiency of the PV module.

3.4 Photoelectric conversion efficiency ()

When the photovoltaic module is exposed to light, the ratio of the output electric power to incident optical power is the photovoltaic conversion efficiency () of the photovoltaic module.where is the incident optical power.

4 Simulation and analysis using MATLAB/Simulink

To prove the advantage of the TCT-CI–connected PV array in concentrated SSPS, this section simulates PV arrays with several common topologies and the TCT-CI topology (Figure 4). The PV array consists of 5 × 5 PV cells. The characteristic curves of the PV modules are shown in Figure 2.

FIGURE 4

FIGURE 4

Several topologies of simulation. (A) SP, (B) BL, (C) HC, (D) TCT, (E) TCT-CI.

The flux density distribution of the hemisphere receiver when the concentrator is a rotating paraboloid is shown in Figure 5. When the PV array is uniformly attached to the surface of the receiver, the light intensity distribution on the same row is approximately equal but different between the rows.

FIGURE 5

FIGURE 5

Flux density distribution of the hemisphere receiver with rotating parabolic concentrators (Liu et al., 2007).

The six light intensity distributions used in the simulation are shown in Table 2, which are based on the light concentration characteristics of the abovementioned rotating parabolic concentrator. Cases 1, 2, and 3 had errors of 10%, and some others had errors of 20%. The PV array was evaluated in three ways: global maximum power (GMP), mismatch loss (MPL), and filling factor (FF).

TABLE 2

Column 1Column 2Column 3Column 4Column 5
(a) Case 1
Row 118401904206018342120
Row 220002164200021322180
Row 319202140206021861820
Row 419401898184021401900
Row 521802194216019562040
(b) Case 2
Row 123201956238021621700
Row 217001730238020281740
Row 322402248170022601820
Row 420001698214021162000
Row 522601620166021541660
(c) Case 3
Row 120101924187018762172
Row 217981789164317571926
Row 314861573169617551485
Row 413091431138014981466
Row 512251105112012881141
(d) Case 4
Row 116402400226823202036
Row 218221973173919872128
Row 315141536129313251616
Row 413101168128213721235
Row 51099119811309911440
(e) Case 5
Row 19739289701017934
Row 2754736877762874
Row 3607564613564554
Row 4430417380364408
Row 5212211202192210
(e) Case 6
Row 11192875974852992
Row 2797868701682666
Row 3507549507694676
Row 4435374399435458
Row 5227164195200198

Six irradiative conditions (units: W/m2).

4.1 Estimation of power generation form TCT and TCT-CI–connected PV arrays

4.1 1TCT-connected PV arrays

In the PV array, if the output current of the array () is greater than the short-circuit current of a row (), the parallel bypass diode will be turned on and the row will be short-circuited. When estimating the GMP of the TCT-connected PV array, we should pay attention to whether a row is short-circuited by the bypass diode.

According to Eqs 1, 2 and Figure 2, when the temperature is at the standard test condition (STC), the output current at the GMPP is almost proportional to the light intensity, and the output voltage almost does not change with the change in light intensity.

represents the current at the GMPP of the module under STC. is used to represent the current at the GMPP of row under the existing irradiative condition. is used to represent the short-circuit current of row under the existing irradiative condition. In Case 1, and are,

Same as the above, get row currents in the other cases, and substitute the values in Table 1 into Eqs 15, 16 to obtain and .

If , row will be short-circuited, and the PV modules in row will not generate electricity.

In Case 1 and Case 2, the difference between the is not large, so no PV module will be short-circuited. The minimum of the row current values is chosen as .

In Case 1,

In Case 2,

In Case 3,

  • a) If , rows 2, 3,4, and 5 will be short-circuited, and in this situation,

  • b) If , rows 3, 4, and 5 will be short-circuited, and in this situation,

  • c) If , rows 4 and 5 will be short-circuited, and in this situation,

  • d) If , row 5 will be short-circuited, and in this situation,

  • e) If , no PV model will be short-circuited, and in this situation,

From a) to e), the value that makes maximum is selected as . So , and no PV model will be short-circuited.

Same as the above, from the other cases is obtained. Results are shown in Table 3.

TABLE 3

Case123456
(A)78.42475.48747.44247.27723.41123.668
(W)4046389524482439725733
Short-circuited partNoneNoneNoneNoneRows 4 and 5Rows 4 and 5

Estimation of the TCT PV array.

When , the output voltage in row is actually less than . When , the output voltage in row is actually greater than and less than . Therefore, this subsection has some errors in estimating the generation of PV arrays but can correctly calculate whether PV modules are short-circuited.

4.1.2TCT-CI–connected PV arrays

Because of the controlled current source of the TCT-CI–connected PV array, each PV module can operate at the GMPP.

According to Table 4, in Case 1, the global maximum power of TCT-CI–connected PV array is defined asSame as the above, from the other cases is obtained. Results are shown in Table 5.

TABLE 4

Row 1Row 2Row 3Row 4Row 5
(a) In Case 1
78.74784.54181.71778.42484.977
84.11490.30387.28683.76990.769
(b) In Case 2
84.88077.29482.86380.32975.487
90.66582.56288.51085.80380.631
(c) In Case 3
79.50671.93364.52157.16847.442
84.92476.83568.91961.06450.675
(d) In Case 4
86.05877.85958.77551.38347.277
91.92483.16662.78154.88550.499
(e) In Case 5
38.91432.31223.41116.1378.285
41.56634.51425.00717.2378.849
(f) In Case 6
39.42229.96223.66816.9577.949
42.10932.00425.28118.1128.491

Current values (units: A).

TABLE 5

Case123456
(W)4214.884136.923308.373316.471199.211188.12

Estimation of the TCT-CI PV array.

4.2 PV arrays’ performance

The models were simulated using MATLAB/Simulink. The PV curves under the light intensity distribution are shown in Figure 6, and the MPL and filling factor are shown in Figure 7.

FIGURE 6

FIGURE 6

PV characteristic curves obtained by the simulation.

FIGURE 7

FIGURE 7

GMPP, MPL, and FF.

In Case 5 and Case 6, the output voltage at GMPP of the TCT-CI PV array is significantly greater than that of the others, indicating that some modules of the others are short-circuited by the bypass diode. This is consistent with the estimate in Section 4.1.

As shown in Figure 6, simulation results show that TCT-CI connected PV arrays have higher output power compared to other PV arrays. PV curves of TCT-CI connected PV arrays show a single peak. So conventional MPPT algorithms can be used here. PV curves of others PV arrays show multiple peaks. Conventional MPPT algorithms cannot track to GMPP, so more complex algorithm is required. Therefore, TCT-CI connected PV arrays reduce the difficulty of MPPT under non-uniform light intensity distribution. As shown by the polyline in Figure 7, the FF of TCT-CI connected PV arrays are slightly larger than that of others, and the MPL of TCT-CI connected PV arrays is 0.

In conclusion, TCT-CI–connected PV arrays have the following advantages under non-uniform illumination intensities:

  • i. no mismatch loss,

  • ii. maximum GMPP,

  • iii. maximum photoelectric conversion efficiency,

  • iv. maximum filling factor and best performance, and

  • v. PV curve showing a single peak value, which reduces the difficulty of MPPT.

5 Experiment and analysis

To further verify that the TCT-CI–connected PV arrays are more suitable for concentrated SSPS, a comparative experiment between the TCT-CI and TCT-CI topologies was carried out. The experimental schematic is shown in Figure 8. The real shooting is shown in Figure 9. In the experiment, 30 photovoltaic models constituting 5*6 photovoltaic arrays were analyzed. Parameters of the PV module for this experiment at STC are shown in Table 6.

TABLE 6

ParameterValve
(W)3.6
(V)6.6
(mA)713
(V)5.6
(mA)642

Parameters of the PV module for this experiment (STC).

FIGURE 8

FIGURE 8

Schematic diagram.

FIGURE 9

FIGURE 9

Real shooting of experiment.

In Figure 8, the dashed line represents parallel controlled current sources. When the PV array is in the TCT topology, the controllable current source is not connected to the PV module. When the PV array is in the TCT-CI topology, the controllable current source is connected to the PV module as shown in Figure 8. During the experiment, the PV array was oriented toward the sun in such a way that sunlight was perpendicular to the PV module.

A pure resistive load was used in the experiment. In the TCT topology experiment, when the line loss was not considered, with the MPPT controller, the power consumed by the load () was the global maximum power () of the PV array. Therefore, can be calculated by directly measuring the voltage across the load.

In the TCT-CI topology experiment, the external power supply was used as a controllable current source. Because the energy of the external power supply is an external input, to obtain the global maximum power () of the PV array, the power of the external power supply () has to be subtracted from the power consumed by the load (). Then, the expression of becomes

In the experiment, some photovoltaic modules were covered with a shading cloth to create a non-uniform light intensity distribution. Five groups of experiments were conducted, and the numbers and positions of the shading cloths are shown in Figure 10.

FIGURE 10

FIGURE 10

Shaded part.

Because the basic light intensity did not change significantly during the experiment, the experimental results were not normalized; of the PV arrays with TCT and TCT-CI topologies obtained in the experiment is shown in Table 7. It can be seen that under a non-uniform light intensity distribution, the global maximum power of the PV array with the TCT-CI topology is significantly larger than that with the TCT topology.

TABLE 7

Shadow formVoc (V)Vmpp (V)Vload (V)PCI (W)Pm (W)
TCTTCT-CITCTTCT-CITCTTCT-CITCT-CITCTTCT-CI
(1)31.9931.9928.0526.8731.3436.568.2480.51101.32
(2)31.9731.829.5724.9723.1636.9616.3643.9795.61
(3)31.3731.2226.9224.191.6336.124.670.2282.15
(4)31.5631.4928.6321.7122.7833.849.7542.5468.52
(5)29.329.324.5924.441.0829.5417.240.146.06

Comparison of experimental Data.

6 Conclusion

This study shows that the TCT-CI–connected PV array is suitable for concentrated SSPS. In the future, the following research has to be carried out: the existing TCT-CI–connected PV array uses a large number of controllable current sources, therefore the number of controllable current sources can be reduced in the next step.

This study analyzes and compares the performance of SP, BL, HC, TCT, and TCT-CI–connected PV arrays under non-uniform light intensity. Several PV arrays with different topologies were simulated by considering light intensity distribution in concentrated SSPS with rotating paraboloids as an example. Finally, comparative experiments on PV arrays with TCT and TCT-CI topologies were carried out. Both simulation and experimental results show that the PV array with TCT-CI topology has the best performance, and the difficulty of MPPT is reduced in non-uniform light intensity distribution.

In other words, PV arrays with TCT-CI topology are more suitable for concentrated SSPS, which can reduce the influence of non-uniform light intensity distribution on the performance of PV arrays.

Statements

Data availability statement

The original contributions presented in the study are included in the article/Supplementary Material; further inquiries can be directed to the corresponding author.

Author contributions

Drafting the manuscript: XL, JM, and YZ; critical revision of manuscript for important intellectual content: GC, GF, DW, and YD.

Funding

This work was supported by the Civil Aerospace Technology Research Project (D010103), the National Natural Science Foundation of China (Grant No. 52022075, Grant No. U1937202), and the National Key R&D Program of China (Grant No. 2021YFB3900300).

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, editors, and reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

  • 1

    AhmadR.AliF. M.HadeedA. S.ShamiU. T.SaheedO. (2017). An analytical approach to study partial shading effects on pv array supported by literature. Renew. Sustain. Energy Rev.74, 721732. 10.1016/j.rser.2017.02.078

  • 2

    AlanaziM.AhmedF.YousriD.RezkH. (2022). Optimal reconfiguration of shaded PV based system using African vultures optimization approach. Alexandria Eng. J.61 (12), 1215912185. 10.1016/j.aej.2022.06.009

  • 3

    AwanM. M. A.Muhammad YaqoobJ.AsgharA. B.EjsmontK. (2022). Performance optimization of a ten check MPPT algorithm for an off-grid solar photovoltaic system. Energies15 (6), 2104. 10.3390/en15062104

  • 4

    BelhachatF.LarbesC. (2021). Pv array reconfiguration techniques for maximum power optimization under partial shading conditions: A review. Sol. Energy230, 558582. 10.1016/j.solener.2021.09.089

  • 5

    BularkaS.GonteanA. (2017). “Dynamic PV array reconfiguration under suboptimal conditions in hybrid solar energy harvesting systems,” in IEEE 23rd international symposium for design and Technology in electronic packaging (SIITME) (IEEE).

  • 6

    ChaoK. H.RizalM. N. (2021). A hybrid mppt controller based on the genetic algorithm and ant colony optimization for photovoltaic systems under partially shaded conditions. Energies14, 2902. 10.3390/en14102902

  • 7

    ElgendyZahawiM. A. B.AtkinsonD. J. (2013). Assessment of the incremental conductance maximum power point tracking algorithm. IEEE Trans. Sustain. Energy4 (1), 108117. 10.1109/tste.2012.2202698

  • 8

    ElyaqoutiIzbaimBouhouchM. D. L. (2021). Study of the energy performance of different PV arrays configurations under partial shading. E3S Web Conf.229 (2), 01044. 10.1051/e3sconf/202122901044

  • 9

    FanG.DuanB.ZhangY.JiX.QianS. (2020). Thermal control strategy of OMEGA SSPS based simultaneous shape and topology optimization of butterfly wing radiator. Int. Commun. Heat Mass Transf.119, 104912. 10.1016/j.icheatmasstransfer.2020.104912

  • 10

    HasanM. A.ParidaS. K. (2016). An overview of solar PV panel modeling based on analytical and experimental viewpoint. Renew. Sustain. Energy Rev.60, 7583. 10.1016/j.rser.2016.01.087

  • 11

    JazayeriM.UysalS.JazayeriK. (2014). A comparative study on different photovoltaic array configurations under partial shading conditions in 2014 IEEE PES T&D Conference and Exposition (Chicago, IL, USA: IEEE), 15.

  • 12

    JinH.ChuX. M.FanJ. Y.JinQ. B.DuanZ. Z. (2016). A novel concentrator with zero-index metamaterial for space solar power station. Adv. Space Res.59 (6), 14601472.

  • 13

    JinQ. B.HuangJ. (2018). The solar-tracking optimal trajectory planning research based on minimum energy consumption in SSPS. Aerosp. Sci. Technol.76, 272279. 10.1016/j.ast.2018.01.038

  • 14

    KrishnaG. S.MogerT. (2018). “SuDoKu and optimal SuDoKu reconfiguration for TCT PV array under non-uniform irradiance condition,” in 2018 IEEE 8th Power India International Conference (PIICON) (IEEE).

  • 15

    LiuF.DuanS.LiuB.KangY.LiF. (2008). A variable step size inc mppt method for pv systems. IEEE Trans. Industrial Electron.55 (7), 26222628. 10.1109/tie.2008.920550

  • 16

    LiuY.DaiJ.LangZ.XinC. (2007). Finite-element analysis for flux distribution on focal plane of rotating parabolic concentrators. Acta Opt. Sin.27 (10), 17751778.

  • 17

    MankinsJ. C. (2002). A technical overview of the “suntower” solar power satellite concept. Acta Astronaut.50 (6), 369377. 10.1016/s0094-5765(01)00167-9

  • 18

    MankinsJ. C. (2013). Sps-alpha: A novel approach to practical space solar power. Ad Astra25 (1), 3841.

  • 19

    MatamM.BarryV. R. (2018). Variable size dynamic pv array for small and various dc loads. Sol. Energy163, 581590.

  • 20

    MehtaH. K.WarkeH.KukadiyaK.PanchalA. K. (2019). Accurate expressions for single-diode-model solar cell parameterization. IEEE J. PVs9 (3), 803810. 10.1109/jphotov.2019.2896264

  • 21

    MohammadS.AhmadiS.ShirzadA. (2015). A pso-based maximum power point tracking for photovoltaic systems under environmental and partially shaded conditions. Prog. Photovoltaics23, 214. 10.1002/pip.2416

  • 22

    NahidanNiroomandM. H. M.DehkordiB. M. (2021). Power enhancement under partial shading condition using a two-step optimal pv array reconfiguration. Int. J. Photoenergy2021, 119. 10.1155/2021/8811149

  • 23

    QiJ. (2022). PV array reconfiguration according to shaded cells' number of every PV module. CSEE J. Power Energy Syst.10.17775/CSEEJPES.2020.06140

  • 24

    RaniIlangoB. I. G. S.NagamaniC. (2013). Enhanced power generation from pv array under partial shading conditions by shade dispersion using su do ku configuration. IEEE Trans. Sustain. Energy4 (3), 594601. 10.1109/tste.2012.2230033

  • 25

    RizzoS. A.GiacomoS. (2021). A hybrid global MPPT searching method for fast variableshading conditions. J. Clean. Prod.298. 10.1016/j.jclepro.2021.126775

  • 26

    SahuH. S.NayakS. K. (2016). Extraction of maximum power from a pv array under nonuniform irradiation conditions. IEEE Trans. Electron Devices63 (12), 48254831. 10.1109/ted.2016.2616580

  • 27

    Sai KrishnaG.MogerT. (2019). Improved SuDoKu reconfiguration technique for total-cross-tied PV array to enhance maximum power under partial shading conditions. Renew. Sustain. Energy Rev.109, 333348. 10.1016/j.rser.2019.04.037

  • 28

    SalamehZ.TaylorD. (1990). Step-up maximum power point tracker for photovoltaic arrays. Sol. Energy44 (1), 5761. 10.1016/0038-092x(90)90027-a

  • 29

    SantosAntunesJ. L. F.Anis ChehabC. C.CruzC. (2006). A maximum power point tracker for pv systems using a high performance boost converter. Sol. Energy80 (7), 772778. 10.1016/j.solener.2005.06.014

  • 30

    SasakiS.TanakaK.HiguchiK.OkuizumiN.KawasakiS.ShinoharaN.et al (2007). A new concept of solar power satellite: Tethered-SPS. Acta Astronaut.60 (3), 153165. 10.1016/j.actaastro.2006.07.010

  • 31

    StoreyJ.Wilson PeterR.BagnallD. (2014). The optimized-string dynamic photovoltaic array. IEEE Trans. Power Electron.29, 17681776. 10.1109/tpel.2013.2265497

  • 32

    TitriS.LarbesC.ToumiK.BenatchbaK. (2017). A new mppt controller based on the ant colony optimization algorithm for photovoltaic systems under partial shading conditions. Appl. Soft Comput.58, 465479. S1568494617302703. 10.1016/j.asoc.2017.05.017

  • 33

    WangY.XueL.ChangN.PedramM. (2012). “Dynamic reconfiguration of photovoltaic energy harvesting system in hybrid electric vehicles,” in Proceedings of the 2012 ACM/IEEE international symposium on Low power electronics and design, 109114. ACM. 10.1145/2333660.2333688

  • 34

    WangCaiS. W.ZengL. (2021). Research on mppt based on gray wolf algorithm improved by levy flight. J. Phys. Conf. Ser.1865 (4), 042089. 10.1088/1742-6596/1865/4/042089

  • 35

    XjaB.BdaB.YzaB.GfaB.MengL. C.YangY. D. (2021). Effect of operational condition of rotational subsystem on attitude control for space solar power station. Chin. J. Aeronautics34 (5), 289297. 10.1016/j.cja.2020.12.034

Summary

Keywords

PV array, space solar power station, current inject, non-uniform light intensity distribution, total-cross-tied

Citation

Li X, Mi J, Zhang Y, Chen G, Fan G, Wang D and Du Y (2023) Current-injected photovoltaic array for concentrated space solar power station. Front. Energy Res. 11:1140537. doi: 10.3389/fenrg.2023.1140537

Received

09 January 2023

Accepted

13 February 2023

Published

01 March 2023

Volume

11 - 2023

Edited by

Amrit Mukherjee, University of South Bohemia in České Budějovice, Czechia

Reviewed by

Daomin Min, Xi’an Jiaotong University, China

Chen Yang, Beijing Institute of Technology, China

Updates

Copyright

*Correspondence: Jianwei Mi,

This article was submitted to Process and Energy Systems Engineering, a section of the journal Frontiers in Energy Research

Disclaimer

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Outline

Figures

Cite article

Copy to clipboard


Export citation file


Share article

Article metrics