CORRECTION article

Front. Immunol., 08 December 2023

Sec. Multiple Sclerosis and Neuroimmunology

Volume 14 - 2023 | https://doi.org/10.3389/fimmu.2023.1335541

Corrigendum: Treatment of surgical brain injury by immune tolerance induced by peripheral intravenous injection of biotargeting nanoparticles loaded with brain antigens

  • 1. Graduate School of Tianjin Medical University, Tianjin, China

  • 2. Tianjin Key Laboratory of Cerebral Vascular and Neurodegenerative Diseases, Tianjin, China

  • 3. Department of Neurosurgery, Tianjin Huanhu Hospital, Tianjin, China

  • 4. Tianjin Key Laboratory on Technologies Enabling Development of Clinical Therapeutics and Diagnostics (Theranostics), Research Center of Basic Medical Science, School of Pharmacy, Tianjin Medical University, Tianjin, China

Article metrics

View details

761

Views

382

Downloads

In the published article, there was an error in Figures 4 and 5 as published. In Figure 4D, two images were placed in opposite positions. In Figure 5B, we provided a more appropriate picture. The corrected Figures 4 and 5 and its caption appear below.

Figure 4

Figure 4

(A) Neurological function scoring histogram. (B) Histogram of peripheral blood CD4+T/CD8+T cell ratios. (C) Histogram of the proinflammatory cytokine IL-2, IL-4 and TGF-β1.*compared with Group A, P < 0.05; #compared with Group B, P < 0.05. (D) Iba-1 expression scoring of microglial cells measured at 21 d after SBI. *compared with Group A, P < 0.05; #compared with Group B, P < 0.05. The brown-positive cells are activated microglial cells, the yellow arrows indicate the somata of the activated microglia, and the red arrows indicate the processes of the activated microglia (x40). The black arrows indicate positive results (the brown cells) (x20). The scale bars are 20μm. (E) GFAP expression scoring of astrocytes measured at 21 d after SBI. *compared with Group A, P < 0.05, **compared with Group A, P < 0.01; #compared with Group B, P < 0.05. The scale bars are 50μm.

Figure 5

Figure 5

(A) FasL expression scoring of nerve cells measured at 21 d after SBI. *compared with Group A, P < 0.05; #compared with Group B, P < 0.05. The black arrows indicate positive results (the brown cells). (B) TUNEL assay of the nerve cells. *compared with Group A, P < 0.05; # compared with Group B, P < 0.05. DAPI (blue) was used to indicate the nuclei (arrows), and TUNEL (green) was used to indicate the apoptotic signals (arrows). The merge indicates the apoptotic cells (arrows). The scale bars are 20 μm.

The authors apologize for these errors and state that this does not change the scientific conclusions of the article in any way. The original article has been updated.

Statements

Publisher’s note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

Summary

Keywords

PBAE/PLGA nanoparticles, biotargeting nanoparticles, myelin basic protein, immune tolerance, surgical brain injury

Citation

Tian Z, Xu L, Chen Q, Feng R, Lu H, Tan H, Kang J, Wang Y and Yan H (2023) Corrigendum: Treatment of surgical brain injury by immune tolerance induced by peripheral intravenous injection of biotargeting nanoparticles loaded with brain antigens. Front. Immunol. 14:1335541. doi: 10.3389/fimmu.2023.1335541

Received

09 November 2023

Accepted

27 November 2023

Published

08 December 2023

Volume

14 - 2023

Edited and reviewed by

Ulises Gomez-Pinedo, Health Research Institute of Hospital Clínico San Carlos, Spain

Updates

Copyright

*Correspondence: Hua Yan, ; Yinsong Wang,

†These authors have contributed equally to this work

Disclaimer

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Outline

Figures

Cite article

Copy to clipboard


Export citation file


Share article

Article metrics