Deformation Monitoring and Risk Assessment of Ultra-High Voltage Transmission Channel Based on Sentinel-1 and RADARSAT-2 Multi-Source InSAR Data
Provisionally accepted- 1State Grid Electric Power Engineering Research Institute Co., Ltd., Beijing, China
- 2State Grid Hubei Electric Power Co., Ltd. Extra High Voltage Company, Wuhan, China
Select one of your emails
You have multiple emails registered with Frontiers:
Notify me on publication
Please enter your email address:
If you already have an account, please login
You don't have a Frontiers account ? You can register here
UHV transmission lines are key infrastructure ensuring the safe cross-regional transmission of national energy. However, these lines are often located in regions facing multiple disturbances, such as complex terrain, frequent geological disasters, and intense human activities, all of which pose significant threats to the stability of tower foundations. To achieve high-precision deformation monitoring and risk identification for typical mountainous transmission corridors, this study selects the Qilian transmission corridor in Badong Countyas the research area. The study integrates two types of C-band SAR data from Sentinel-1A and RADARSAT-2, employing SBAS-InSAR technology to perform time-series deformation analysis from July 2019 to August 2020. Additionally, the Getis-Ord Gi* statistical method is introduced to assess subsidence hot spots. The results show that the annual average deformation in the region, as obtained from Sentinel-1A data, mainly ranges from –10 mm/a to +10 mm/a, indicating a generally stable deformation trend. In contrast, RADARSAT-2, with its high resolution, identifies several local strong subsidence areas, with the maximum annual subsidence rate reaching –95.6 mm/a. These areas are mainly located in geomorphological transition zones such as the northern bank of the Yangtze River and valley intersections. A typical slope area on the northern bank of the Yangtze River shows persistent subsidence bands with an annual average deformation exceeding –76 mm/a, which closely coincides with tower foundation construction areas, steep slopes, and traffic disturbance zones. In the valley-crossing section, significant subsidence hot spots (greater than –20 mm/a) are identified in the mid-and lower slope foot regions, while cold spots are observed in the high-slope areas, with deformations lower than –5 mm/a. Both data types exhibit highly consistent time-series trends at characteristic points, and scatter density map analysis demonstrates a strong linear correlation between them, validating the complementarity and fusion potential of multi-source InSAR data for deformation monitoring in complex mountainous environments. The multi-source InSAR monitoring and spatial aggregation analysis framework developed in this study enables rapid identification of high-risk sections in UHV transmission corridors. It provides high-resolution, quantitative support for slope deformation early warning, tower foundation stability assessment, and operation and maintenance scheduling, offering excellent engineering adaptability and broad applicability.
Keywords: InSAR, Multi-source, Ultra-high voltage, Deformation monitoring, Risk Assessment
Received: 04 Apr 2025; Accepted: 22 Jan 2026.
Copyright: © 2026 Yi, Shenli, Binbin, Yu, Hao, Xiaoang and Yong. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
* Correspondence: Liu Yi
Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.