ORIGINAL RESEARCH article

Front. Oncol., 13 August 2020

Sec. Women's Cancer

Volume 10 - 2020 | https://doi.org/10.3389/fonc.2020.01410

Machine Learning-Based Radiomics Nomogram Using Magnetic Resonance Images for Prediction of Neoadjuvant Chemotherapy Efficacy in Breast Cancer Patients

  • SC

    Shujun Chen 1,2,3

  • ZS

    Zhenyu Shu 4

  • YL

    Yongfeng Li 1,2,5

  • BC

    Bo Chen 1,2,6

  • LT

    Lirong Tang 1,2,3

  • WM

    Wenju Mo 1,2,5

  • GS

    Guoliang Shao 1,2,3*

  • FS

    Feng Shao 1,2,7*

  • 1. Cancer Hospital of the University of Chinese Academy of Sciences (Zhejiang Cancer Hospital), Hangzhou, China

  • 2. Institute of Cancer and Basic Medicine (IBMC), Chinese Academy of Sciences, Hangzhou, China

  • 3. Department of Radiology, Zhejiang Cancer Hospital, Hangzhou, China

  • 4. Department of Radiology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital of Hangzhou Medical College, Hangzhou, China

  • 5. Department of Breast Surgery, Zhejiang Cancer Hospital, Hangzhou, China

  • 6. Department of Pathology, Zhejiang Cancer Hospital, Hangzhou, China

  • 7. Department of Gynecological Oncology, Zhejiang Cancer Hospital, Hangzhou, China

Abstract

Purpose: The construction and validation of a radiomics nomogram based on machine learning using magnetic resonance image (MRI) for predicting the efficacy of neoadjuvant chemotherapy (NACT) in patients with breast cancer (BCa).

Methods: This retrospective investigation consisted of 158 patients who were diagnosed with BCa and underwent MRI before NACT, of which 33 patients experienced pathological complete response (pCR) by the postoperative pathological examination. The patients with BCa were divided into the training set (n = 110) and test set (n = 48) randomly. The features were selected by the maximum relevance minimum redundancy (mRMR) and absolute shrinkage and selection operator (LASSO) algorithm in the training set. In return, the radiomics signature was established using machine learning. The predictive score of each patient was calculated using the radiomics signature formula. Finally, the predictive scores and clinical factors were used to perform the multivariate logistic regression and construct the nomogram. Receiver operating characteristics (ROC) analyses were used to assess and validate the diagnostic accuracy of the nomogram in the test set. Lastly, the usefulness of the nomogram was confirmed via decision curve analysis (DCA).

Results: The radiomics signature was well-discriminated in the training set [AUC 0.835, specificity 71.32%, and sensitivity 82.61%], and test set (AUC 0.834, specificity 73.21%, and sensitivity 80%). Containing the radiomics signature and hormone status, the radiomics nomogram showed good calibration and discrimination in the training set [AUC 0.888, specificity 79.31%, and sensitivity 86.96%] and test set (AUC 0.879, specificity 82.19%, and sensitivity 83.57%). The decision curve indicated the clinical usefulness of our nomogram.

Conclusion: Our radiomics nomogram showed good discrimination in patients with BCa who experience pCR after NACT. The model may aid physicians in predicting how specific patients may respond to BCa treatments in the future.

Introduction

Currently, breast cancer (BCa) is the most commonly diagnosed malignancy in females worldwide as of 2018, accounting for ~25% of all new diagnoses and nearly 15% of cancer-associated deaths in females (1). This translates to 2.1 million new cases of BCa in 2018, along with more than 600,000 BCa-related deaths. Globally, women have a 5% cumulative risk of being diagnosed with BCa by the age of 75, although the risk varies substantially by country.

Neoadjuvant chemotherapy (NACT) is a central component of BCa therapy (2). In previous studies, NACT has been associated with lower disease stages, increased sensitivity of chemotherapy drugs, improved resection and breast preservation rates, and increased pathological complete response (pCR) in some patients with BCa (3, 4). The disease-free survival (DFS) and overall survival (OS) of BCa patients with pCR are significantly longer than those of patients without pCR (5), suggesting that pCR may be a potential prognostic factor and target of NACT. However, even with the latest advances in chemotherapy regimens, the number of patients with pCR remains low at 12–28% worldwide (6). In non-pCR patients, NACT may fail to produce a full therapeutic effect, which can delay surgical intervention (7). Accordingly, the rapid and effective screening of patients is critically important to identify patients more likely to respond to NACT, which may lead to improved patient outcomes.

In recent years, there has been extensive cross integration of radiation medicine with bioengineering, which has produced the field of radiomics (8, 9). Radiomics is a method for the extraction of high-dimensional data from radiographic medical images using data-characterization algorithms. Recent studies have shown that radiomics features of magnetic resonance imaging (MRI) may allow for the prediction of NACT and radiotherapy response in patients with rectal cancer (10). In addition, the radiomic features from MRI have been used to predict how patients with BCa would respond to NACT before the treatment was initiated (11). Recently, a new multicenter study was conducted to assess a multiparameter prediction model using MRI data that could accurately predict which patients would have pCR before undergoing treatment (12). While radiomics may be used to predict the efficacy and potential benefits of NACT, no studies have evaluated the potential impact of different machine learning techniques on radiomics.

Machine learning involves the building of data-derived computational models and methods to improve the accuracy, performance, or predictive abilities of the model, which is an important part of radiomics (13, 14). Accordingly, machine learning strategies have high prognostic and predictive power, along with excellent stability, all of which are desired for radiomics-based analyses. In this study, our aim was to use a highly predictive and stable machine learning strategy for constructing a radiomics nomogram that could be used to predict pCR in patients with BCa. The radiomics nomogram provides a noninvasive, convenient, and low-cost strategy that may improve the treatment of BCa in the future.

Materials and Methods

Patient Information

This study was approved by the Ethics Committee of Zhejiang Cancer Hospital (Gongshu, P.R. China). The requirement for informed consent was waived due to the retrospective nature of this study. The patients were enrolled in our hospital from June 2017 to December 2019. All the patients underwent MRI within 1–2 weeks prior to NACT. The inclusion criteria for this study were as follows: (a) invasive BCa confirmed by biopsy without distant metastasis; (b) complete NACT was initiated with no prior history of treatment; and (c) surgery was performed after NACT, and pathological evaluation was performed after the operation. The exclusion criteria for this study were as follows: (a) NACT was not completed; (b) surgery was not performed, or postoperative pathology was not evaluated; and (c) the MRI data were unavailable. In addition, the study population was group by 7:3 according to the diagnosis time. The patients from June 2017 to January 2019 were part of the training set (n = 110). During the training period, the robustness of the radiomic features was tested, and the model was constructed. The patients from February 2019 to December 2019 were part of the test set (n = 48) to verify the reliability of the constructed model. The recruitment path of the subjects and research design of this study are shown in Figure 1.

Figure 1

MRI Scanning Process and Immunohistochemical Evaluation

All breast MRI scans were performed at a local hospital using the 3.0 Tesla MRI scanner (MAGNETOM Verio A Tim System; Siemens Healthcare, Erlangen, Germany). During the scan, an axial fat-suppressed T2WI sequence and axial diffusion weight imaging (DWI) images were obtained using the two b-values of 0 and 1,000 s/mm2 before the contrast agent was administered. Initially, a fat-saturated T1WI scan was recorded before injection of the contrast agent or dynamic contrast-enhanced (DCE) scanning were performed. Next, DCE images were acquired as six post-injection scans with intervals of 38 s following the intravenous injection of Magnevist. Next, 0.2 mL/kg of body weight of the gadolinium-based agent (Magnevist; Bayer Healthcare, Berlin, Germany) was injected using an MRI compatible power injector (rate = 2 mL/s), which was flushed with 20-mL of saline using the high-pressure injector. Additional details about the MRI parameters can be found in the Supporting Information.

Immunohistochemistry (IHC) was used to assess the expression of several receptors and antigens commonly associated with BCa from biopsy in the pre NACT, including estrogen receptor (ER), progesterone receptor (PR), human epidermal growth factor receptor 2 (HER2), and antigen Ki67 (Ki-67). Tumors with <1% of nuclear staining were denoted as ER/PR-negative, while ≥1% was denoted as ER/PR-positive. Next, 20% was established as the cutoff value for Ki-67 expression. In terms of HER2 expression, IHC scores of 0 or 1+ were denoted as HER2-negative, and 3+ was denoted as HER2-positive. An IHC score of 2+ required further investigation using in situ hybridization (ISH), with non-amplified results being denoted as HER2-negative and amplified results being HER2-positive.

NACT and the Pathological Response of Treatment

The patients included in this study underwent four or six cycles of NACT before undergoing breast surgery. The National Comprehensive Cancer Network (NCCN) guidelines were used to establish the therapy timeline and procedures (15). In this study, 85% of patients (n = 121) were given the taxane-based NACT regimen, while the remaining 15% of patients (n = 21) were given the anthracycline and taxane-based NACT regimen. Additionally, the patients found to be HER2-positive were prescribed trastuzumab (loading dose = 8 mg/kg; maintenance dose = 6 mg/kg). All of the patients underwent surgery after NACT, and pathological specimens were evaluated using the Miller-Payne system (16) for the pathological assessment of NACT response. The histopathological examination and analysis were performed by a dedicated breast pathologist, who was blinded to the MRI data, with more than 12 years of experience in the field of breast pathology. Next, the efficacy of NACT was determined by examination and comparison of the specimens from the initial biopsies with those obtained from the radical resection specimens. The Miller-Payne system is divided into five grades. In the current study, grade 5 and the absence of lymph node invasion in the ipsilateral sentinel node or lymph nodes removed during axillary dissection (yPT0/isN0), while the remaining grades were denoted as the non-pCR group. Additional details about the pathological grades can be found in the Supporting Information.

Segmentation and Preprocessing of MR Images

The DCE-MRI images were imported into the itk-snap software. The third phase, which showed the most apparent enhancement, was selected for sketching tumor boundaries. The largest layer of the tumor was selected for sketching, and areas of necrosis, calcification, and bleeding were avoided. The region of interest (ROI) of the tumor was saved and imported into the DWI images (b = 1,000 s/mm2) and T2WI images using the replication function. Next, the ROIs of tumors from three different MRI sequences were saved. In addition, manual corrections were further performed to prevent small deviations in delineating the ROI boundary. All tumor sketches were completed by two senior radiologists independently without knowing the pathological results. Radiologist A had ten years of experience, and radiologist B had ~15 years of experience in the study of breast radiology.

The ROIs from the three MRI sequences were loaded into the AK analysis software for feature extraction. The images were initially processed before the feature extraction was performed. The initial processing of images required the resampling of voxels to 1 × 1 × 1 mm3 and standardization of gray levels to the 1–256 scale. This eliminated the potential influences of different imaging sequences on the extracted features (17).

Extraction of Radiomic Features

AK software was used to extract the radiomic features, including the histogram, FormFactor, gray level co-occurrence matrix (GLCM), and run-length matrix (RLM). These features can characterize the heterogeneity of cancer and reflect changes in the tumor microstructure (17). The most robust features were used for manual correction purposes to improve the usefulness of the model (18). The Spearman's rank test was used to assess the correlation coefficients between features of set-A (Radiologist A) and set-B (Radiologist B). Any features that had correlation coefficients > 0.8 were denoted as having “robust” features (19). Three sets of robust features corresponding to T2WI, DWI, and DCE sequences were obtained. The feature values in this study were the average values of feature set-A and feature set-B.

Establishment of an Optimal Radiomics Signature Based on Machine Learning

The maximum-relevance minimum redundancy (mRMR) algorithm was used to extract the robust features in the training set. Maximum relevance allowed for the selection of features most associated with pCRs (20), while minimum redundancy allowed for the selection of features with minimal redundancy among the others. Optimal features set with high correlation and low redundancy were obtained using the mRMR algorithm. Next, the typical absolute shrinkage and selection operator (LASSO) algorithm allowed for the reduction of dimensions and construction of the radiomics signature through machine learning techniques (21).

The five machine learning classifiers utilized in this study included Support Vector Machine (SVM), Bayes, k-Nearest Neighbor (KNN), Random Forest, and Decision Tree. The machine learning models were constructed using five-fold cross-validation. In short, this required that 20% of data be used to test the model, while the other 80% of data were used to create the model. After a total of 10 repeats, the average values were used to estimate the performance of the model. To demonstrate the correlation between the radiomics signature and pCR status, the signature model was used to score the training set in terms of pCR probability. The score was defined as the rad score, and was used to determine the effectiveness of the signature models for differentiating between pCR and non-pCR patients. The formula of the model used in the training set was employed to calculate the scores for the test set. Lastly, the accuracy of the radiomics signature from the training and test sets was evaluated with area under curve (AUC) value of receiver operating characteristic (ROC) curve. In addition, we selected the machine learning method with the largest AUC and the smallest difference between the training and the verification sets as the model construction method of this study. Detailed information about the dimensionality reduction and radiomics signature can be found in the Supporting Information.

Development and Evaluation of the Radiomics Nomogram

For the training group, univariate logistic regression analyses were performed to select independent predictors of pCR for each potential predictive variable, including clinical factors (i.e., gender, age, and menstrual status), clinical stage of the tumor, biomarker expression (i.e., ER, PR, HER2, and Ki-67), and the rad score. Multivariable logistic regression analyses that combined the independent predictors were applied to develop a pCR prediction model. Next, multivariate logistic regression was used to create the radiomics nomogram.

The variance inflation factor (VIF) was used to diagnose the collinearity of each variable (22) with VIF values >10, indicating severe multicollinearity (23). The calibration performance was evaluated with the calibration curve, and fitness was analyzed by the Hosmer–Lemeshow test. The ROC curve allowed for the estimation of diagnostic accuracy using the nomogram. The probability score for pCR was determined for the patients included in the study using the nomogram, and all patients were divided into high or low probability groups according to the ROC curve cut-off value. The clinical effect of the nomogram was determined using the actual patients with pCR from the different probability groups. The net benefit of the nomogram was determined using the DCA curve (24).

Statistical Analysis

SPSS 17.0 software (IBM, Chicago, IL, USA) was used to perform the Kolmogorov–Smirnov test for evaluating the normality of the distribution of the data, and the chi-square test for the categorical data. The likelihood ratio test with backward step-down selection was applied to the multivariate logistic regression model. VIFs were calculated using the SPSS 17.0 software. The MedCalc15.8 software (MedCalc, Ostend, Belgium) was used to assess the ROC curves, and differences between various AUCs were compared with the DeLong test. The R statistical software Version 3.4.1 was used for all other statistical analyses. The “mRMRe” and “glmnet” packages were used for mRMR and LASSO analyses. Calibration plots and the radiomics nomogram were established with the “rms” package, and DCA with the “dca.R” package. Two-sided p < 0.05 were considered as being statistically significant.

Results

Characteristics of Patients in This Study

A flowchart of participant recruitment is presented in Figure 1. No significant differences were detected in the age, menstrual status, clinical stage of the tumor, or biomarker expression (i.e., ER, PR, HER2, and Ki-67) between patients in the training and test sets, as shown in Table 1. However, significant differences in ER expression, PR expression, and the radiomics signature were detected between pCR and non-pCR (all p < 0.05). As shown in Table 2, the other differences were insignificant.

Table 1

VariablesTraining set (n=110)Test set (n=48)P-value
n%n%
Age (years, mean ± SD)49.85 ± 8.7852.96 ± 8.970.442
Menstrual statusPremenopausal6861.83879.20.051
Postmenopausal4238.21020.8
Histologic typeNST invasive carcinoma8980.93981.30.96
Other2119.1918.7
Clinical stageI1614.5714.60.954
II6458.22960.4
III3027.31225
ER statusNegative4944.52245.80.881
Positive6155.52654.2
PR statusNegative4339.11837.50.85
Positive6760.93062.5
HER2 statusNegative5146.41531.30.076
Positive5953.63368.7
Ki-67Low1917.3816.70.926
High9182.74083.3

Clinical characteristics of patients in the primary and internal validation cohorts.

ER, estrogen receptor; PR, progesterone receptor; HER2, human epidermal growth factor receptor 2; Ki-67, antigen Ki67.

Table 2

VariableTraining set (n=110)Test set (n=48)
pCR (n = 23)Non-pCR (n = 87)pCR (n = 10)Non-pCR (n = 38)
n (%)n (%)P-valuen (%)n (%)P-value
Age (years, mean ± SD)48.9 ± 10.650.1 ± 8.30.58348.8 ± 8.754.1 ± 8.80.112
Menstrual statusPremenopausal15 (62.2)53 (60.9)0.7069 (90)28 (73.7)0.275
Postmenopausal8 (34.8)34 (39.1)1 (10)10 (26.3)
Histologic typeNST invasive carcinoma16 (69.6)73 (83.9)0.128 (80)31 (81.6)0.909
Other7 (30.4)14 (16.1)2 (20)7 (18.4)
Clinical stageI3 (13)13 (14.9)0.8122 (20)5 (13.2)0.993
II13 (56.5)51(58.6)7 (70)21 (55.3)
III7 (30.5)23 (26.5)1 (10)12 (31.5)
ER statusNegative16 (69.6)33 (37.9)0.007*8 (80)14 (36.8)0.015*
Positive7 (30.4)54 (62.1)2 (20)24 (63.2)
PR statusNegative16 (69.6)27 (31)0.001*6(60)9 (23.7)0.027*
Positive7 (30.4)60 (69)4 (40)29 (76.3)
HER2 statusNegative14 (60.9)37 (42.5)0.1176 (60)12 (31.6)0.099
Positive9 (39.1)50 (57.5)4 (40)26 (68.4)
Ki-67Low5 (21.7)14 (16.1)0.5242 (20)6 (15.8)0.751
High18 (78.3)73 (83.9)8 (80)32 (84.2)
Radiomics model score0.773 ± 1.934−2.244 ± 2.430.001*0.349 ± 1.587−2.629 ± 1.9120.001*

Clinical characteristics of the training and validation sets of breast cancer (BCa) patients with and without pCR.

ER, estrogen receptor; PR, progesterone receptor; HER2, human epidermal growth factor receptor 2; Ki-67, antigen Ki67.

*

p < 0.05, with significant differences for clinical characteristics of pCR group and Non-pCR group.

Development of the Radiomics Signature and Assessment of Its Accuracy

The radiomics workflow is shown in Figure 2. A total of 328 radiomics features were obtained from the T2WI, DWI, and DCE sequence images. Accordingly, 984 radiomics features were extracted from each patient. The optimal combination of texture features from T2WI and DWI were chosen, and the random forest method was used to construct the radiomics signature. First, 396 features were obtained from the combination of radiomic features through the detection of robustness and reproducibility. Next, 35 features with the highest mRMR rankings were selected to establish the optimal subset, and LASSO was used to reduce the dimensions of the optimal subset to obtain a total of six features, among which three of the features were from T2WI images, and three were from DWI images. Finally, the six features were used to construct the radiomics signature model. In this study, the diagnostic accuracy of the radiomic signatures constructed by the random forest showed good prediction performance in both the training set and the test set, while the difference between the two was the smallest. The radiomic signature showed favorable predictive efficacy in the two sets with AUC values of 0.835 and 0.834, specificity of 71.32 and 73.21%, and sensitivity of 82.61 and 80%, respectively. Rad-scores, which were calculated using the radiomics signature formula, were significantly different between the pCR and non-pCR in training and test sets, indicating that radiomics signature has a good correlation with pCR clinical outcome, as shown in Figure 3. The evaluation results of other sequence feature combinations and different machine learning techniques used to construct the radiomics signature are shown in Figure 4. Information about the dimensionality reduction process and LASSO are shown in the Supporting Information.

Figure 2

Figure 3

Figure 4

Development and Performance of the Radiomics Nomogram

Univariate logistic regression analyses revealed that ER status, PR status, and the radiomics signature were independent predictors of pCR. Based on the independent predictors, multiple logistic regression was utilized to construct prediction models and the nomogram, as shown in Table 3 and Figure 5. The VIFs of ER status, PR status, and the radiomics signature were 1.017, 1.011, and 1.02, respectively.

Table 3

VariableUnivariate logistic regressionMultivariate logistic regression
OR (95% CI)P-valueOR (95% CI)P-value
Age (per one increase)0.955 (0.884–1.031)0.238NANA
Menopausal (No vs. Yes)0.621 (0.145–2.656)0.52NANA
Histologic type (NST invasive carcinoma vs. Other)2.345 (0.508–9.811)0.118NANA
ER status (Negative vs. Positive)0.255 (0.068–0.958)0.043*0.215 (0.062–0.745)0.015*
PR status (Negative vs. Positive)0.174 (0.045–0.675)0.011*0.214 (0.064–0.715)0.012*
HER2 status (Negative vs. Positive)0.736 (0.195–2.783)0.651NANA
Clinical stage (I vs. II)0.758 (0.167–3.446)0.72NANA
Clinical stage (I vs. III)0.838 (0.295–2.375)0.739NANA
Ki-67 (Low vs. High)0.913 (0.149–5.577)0.921NANA
Radiomics score (per 0.1 increase)2.575 (1.591–4.168)0.001*2.408 (1.56–3.715)0.001*

Logistic regression analysis for predicting pCR in breast cancer (BCa) patients.

ER, estrogen receptor; PR, progesterone receptor; HER2, human epidermal growth factor receptor 2; Ki-67, antigen Ki67.

*

p < 0.05.

Figure 5

The calibration curves showed excellent consistency between the predicted and actual pCR probabilities in the radiomics nomogram of both patient sets. The accuracy, specificity, and sensitivity of the nomogram for predicting pCR were 0.888, 79.31, and 86.96% in the training set and 0.879, 82.19, and 83.57% in the test set. The DeLong test showed AUCs of ER and PR were significantly different from that of nomogram in the training and test sets, as shown in Table 4. Therefore, the nomogram was found to perform well in both sets. Next, the Hosmer-Lemeshow test found no statistical differences between the training and test sets (p > 0.05), verifying the superior diagnostic accuracy of the nomogram. The pCR probability scores were estimated using the nomogram, and patients were classified into the high and low probability groups according to the Yonden index (cut-off: 0.3371), which was based on the nomogram constructed by the training set. The number of pCR cases was significantly different between the high and low probability groups (p < 0.0001). In addition, DCA curves showed excelled net benefits of patients in training and test sets, as shown in Figure 6.

Table 4

Nomogram(95% CI)Signature (95% CI)ER status(95% CI)PR status(95% CI)
Training set0.888 (0.814–0.94)0.835 (0.753–0.899)0.658 (0.562–0.746)0.693 (0.598–0.777)
Nomogram vs. other metrics0.0956<0.0001*0.0015*
Signature vs. other metrics0.0133#0.075
ER status vs. PR status0.06392
Test set0.879 (0.752–0.955)0.834 (0.699–0.926)0.716 (0.567–0.837)0.642 (0.491–0.775)
Nomogram vs. other metrics0.14460.0384*0.0066*
Signature vs. other metrics0.22390.0366#
ER status vs. PR status0.5265

AUCs of Nomogram, radiomics Signature, ER status, and PR status for pCR prediction in Trarining and Test sets.

p-value refers to Delong test for the differences of AUCs between different metrics in different cohorts,

*

p < 0.05, with significant differences for AUCs of Signature, ER status, and PR status compared with that of nomogram.

#

p < 0.05, with significant differences for AUCs of ER status and PR status compared with that of Signature.

Figure 6

Discussion

In this retrospective study, we have quantified the prognostic abilities of different machine-learning techniques for predicting the pCR status of patients with BCa. Considering the stability and prognostic performance together, two feature selection sequences (i.e., T2WI and DWI) and the random forest classification method should be preferred for the prediction of NACT response, as they display higher prognostic abilities and stability when compared with the other models. In addition, the nomogram constructed by the radiomics signature and pathological indexes could effectively predict the patients with pCR. In total, these findings indicate that imaging-based heterogeneity using machine learning and “big data” can provide complementary prognostic information about existing risk predictors.

In recent years, several research groups have searched for clinical or molecular markers that can predict the effect of NACT for the screening of patients who can benefit from the treatment (25). However, up to now, no factor has been found that can accurately predict the efficacy of NACT. The main reason is that the accuracy of single factor prediction is limited, yet a multifactor prognostic model may overcome this limitation for BCa. Based on this principle, a multifactor pCR prediction model was developed in this study. At the same time, we also extracted radiomic features from multiparameter images, including T2WI, DWI, and DCE. In the past, the features were extracted from multiparameter images to predict the prognosis of patients by merely distinguishing features of a single and joint sequence (26, 27). However, in this study, we created a pairwise sorting combination of three sequences (T2WI, DWI, and DCE), which further expanded the scope of this type of research. In addition, our result is consistent with Yoon's results that the features most associated with the clinical outcome of pCR mainly include Inverse difference moment and short-run emphasis features (28), which indicated these two types of feature had significant difference between non-pCR patients and pCR patients with breast cancer experiencing NACT. Although the remaining features also represent the degree of heterogeneity, the exact calculation method of each feature value varies depending on the parameters. Therefore, it is difficult to explain the subtle differences of various heterogeneous parameters caused by the mathematical equations. Besides, the unique biological mechanism that may cause heterogeneity parameters still remains unclear, which may require further research to figure out its mechanism.

The combination of features from T2WI and DWI sequences showed excellent performance of diagnosis for structure radiomics signature, suggesting that a conventional sequence can be used to predict the status of pCR without requiring enhanced imaging techniques in the future, such as DCE. Although recent studies have shown that DCE-MRI is the best sequence to predict NACT response so far (29, 30). Unfortunately, in this study, we found that the prediction efficacy of the radiomics signature was not optimal after combining the features extracted from DCE sequences with those of T2WI or DWI. This is mainly due to the instability of the model performance. Although the performance of the DCE-T2WI combination or the DCE- DWI combination model in the training group is higher than that of the T2WI-DWI combination model, the performance of the model with DCE features in the test set is significantly lower to that of the training group, which indicates that the model stability is not favorable. It may be possible that we only analyzed one 2D slice in a tumor other than a whole 3D tumor in this study, which may cause the instability of the model, we will conduct a further study using 3D tumor to validate the model stability in future research.

This may be due to the different amounts of contrast agent, which can affect the selection of features. Since patients receive different amounts of contrast agent, the enhancement effects of images can affect the permeability of tissue microvascular (31). This reflects the distribution of pixels and further affects the stability of the overall construction model. DWI was previously found to be useful as a tool to measure the efficacy of NACT in patients with BCa (32). However, the diffusion characteristics of water in tissue reflect the heterogeneity of tumors, rather than some external factors, such as contrast agents, which reflect the heterogeneity of tumor by imaging features. Accordingly, it should be demonstrated that T2WI and DWI sequences provide a suitable combination for feature extraction.

The development of statistical models that use the tumor and treatment data from a single patient are better prognostic indicators than human experts (33). Hence, the radiomics-based machine-learning models may be a viable tool for clinical decision support. In this study, we use different machine learning methods to construct a radiomics signature for the extended sequence combination and obtained the highest AUC of 0.835. In another study, Braman et al. (34) also used radiomics to predict pCR status based on different machine learning methods, yet their accuracy was significantly lower than the results of this study with an AUC of 0.74. This may be due to our radiomic features having higher dimensions in our study, which can better reflect the heterogeneity of tumors (35, 36). On the other hand, this study uses a variety of potential factors combined with the radiomics signature to build the prediction model, which also improved the accuracy of this model. In this study, we found that ER and PR expression were independent predictors of patients with pCR, which is similar to other studies (37, 38). The diagnostic efficacy of the nomogram was higher than the signature after adding pathological indicators, which further demonstrates the important role of hormone receptors in the prediction of pCR status. The relationship between texture-based heterogeneity indices and pathologic prognostic factors in breast cancer was confirmed as well. Tumor heterogeneity measured on FDG PET was higher in LABC with poor prognostic pathologic features, such as hormone receptor negativity, nuclear grade 3, and triple negativity (39).

Several features differentiate our work in this study from other radiomic-based studies. First, only features with high repeatability were used in this study, making this approach less prone to the risk of overfitting. The traditional repeatability test is to test the consistency of all the extracted features among the observers, which may allow for some features with poor repeatability to be included in the study. For this reason, some of the features with low repeatability may not accurately reflect the degree of tumor heterogeneity. On the other hand, we also reduced the dimensions of the features from the MRI sequences, including mRMR of the emerging method and LASSO of the traditional dimension reduction method, which may also explain why the diagnostic efficiency of our model is better than other prediction models constructed from LASSO alone. The superiority of this model is also related to the optimal machine learning techniques used to build the model. Therefore, the optimization of the classifier of this model is another important aspect of the study, which differs from traditional radiomics studies. Lastly, our nomogram was created for clinical research. A nomogram is a statistical tool that may be utilized to assess the probability or risk of a specific clinical outcome. For clinical practice, nomograms can be used to provide detailed risk assessments for the patient, aiding in clinical decision-making for clinicians (40). In our study, we built a radiomics nomogram that combines multi-dimensional information, which dramatically improved the accuracy and effectiveness of our model. These technical advances have contributed to the improved reproducibility found in our current study.

We acknowledge several shortcomings of the current study. First, this is a study representing only one medical center, which may not be applicable to populations in other centers. However, this study utilized a contemporary cohort of patients with BCa, allowing for the derivation of a hybrid nomogram that may be used to assess more extensive and diverse populations in the future. Secondly, a single slice of the tumor was sampled for the radiomics analysis, and volumetric assessments were not performed. In a previous study, data from a single slice was found to be sufficient for this type of analysis (41). Finally, our study population was relatively small. As this is a first proof-of-principle study, future studies should employ larger patient populations.

The potential prognostic abilities of radiomics models have been highlighted in other studies. However, with the expanded use of radiomics and feature dimensions, along with machine learning techniques, higher prognostic performance could be achieved in patients with BCa. This is also reflected in our nomogram, which showed high accuracy in the prediction of patients with pCR. As a non-invasive prediction tool, it can broaden the scope in the application of genomics for cancer treatment.

Statements

Data availability statement

All datasets generated for this study are included in the article/Supplementary Material.

Ethics statement

The studies involving human participants were reviewed and approved by Ethics committee of Zhejiang Cancer Hospital. Written informed consent for participation was not required for this study in accordance with the national legislation and the institutional requirements.

Author contributions

All authors listed have made a substantial, direct and intellectual contribution to the work, and approved it for publication.

Funding

This work was supported by the Social Development Project of Zhejiang Public Welfare Technology Application (LGF18H180006) and Zhejiang Provincial Health and Health Commission General Project (2020KY068). The funders of this study were not involved in the design, collection of data, or analysis of this study. They did not impact the preparation or decision to publish this manuscript.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Supplementary material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fonc.2020.01410/full#supplementary-material

References

  • 1.

    SiegelRLMillerKDJemalA. Cancer statistics 2016. CA Cancer J Clin. (2016) 66:730. 10.3322/caac.21332

  • 2.

    Early Breast Cancer Trialists' Collaborative Group (EBCTCG). Long-term outcomes for neoadjuvant versus adjuvant chemotherapy in early breast cancer: meta-analysis of individual patient data from ten randomised trials. Lancet Oncol. (2018) 19:2739. 10.1016/S1470-2045(17)30777-5

  • 3.

    Barroso-SousaRSilvaDDAlessiJVManoMS. Neoadjuvant endocrine therapy in breast cancer: current role and future perspectives. Ecancermedicalscience. (2016) 10:609. 10.3332/ecancer.2016.609

  • 4.

    UntchMKonecnyGEPaepkeSvon MinckwitzG. Current and future role of neoadjuvant therapy for breast cancer. Breast. (2014) 23:526537. 10.1016/j.breast.2014.06.004

  • 5.

    RastogiPAndersonSJBearHDGeyerCEKahlenbergMSRobidouxAet al. Preoperative chemotherapy: updates of National Surgical Adjuvant Breast and Bowel Project Protocols B-18 and B-27. J Clin Oncol. (2008) 26:77885. 10.1200/JCO.2007.15.0235

  • 6.

    MatthewsCMNymbergKBergerMVargoCADempseyJLiJet al. Pathological complete response rates with pertuzumab-based neoadjuvant chemotherapy in breast cancer: a single-center experience. J Oncol Pharm Pract. (2020) 26:5729. 10.1177/1078155219857800

  • 7.

    ChenVEGillespieEFZakeriKMurphyJDYasharCMLuSet al. Pathologic response after neoadjuvant chemotherapy predicts locoregional control in patients with triple negative breast cancer. Adv Radiat Oncol. (2017) 2:1059. 10.1016/j.adro.2017.01.012

  • 8.

    EstevaAKuprelBNovoaRAKoJSwetterSMBlauHMet al. Dermatologist-level classification of skin cancer with deep neural networks. Nature. (2017) 542:1158. 10.1038/nature21056

  • 9.

    KermanyDSGoldbaumMCaiWValentimCLiangHBaxterSLet al. Identifying medical diagnoses and treatable diseases by image-based deep learning. Cell. (2018) 172:112231.e9. 10.1016/j.cell.2018.02.010

  • 10.

    ShuZFangSYeQMaoDCaoHPangPet al. Prediction of efficacy of neoadjuvant chemoradiotherapy for rectal cancer: the value of texture analysis of magnetic resonance images. Abdom Radiol. (2019) 44:377584. 10.1007/s00261-019-01971-y

  • 11.

    Chamming'sFUenoYFerréRKaoEJannotASChongJet al. Features from computerized texture analysis of breast cancers at pretreatment MR imaging are associated with response to neoadjuvant chemotherapy. Radiology. (2018) 286:41220. 10.1148/radiol.2017170143

  • 12.

    XiongQZhouXLiuZLeiCYangCYangMet al. Multiparametric MRI-based radiomics analysis for prediction of breast cancers insensitive to neoadjuvant chemotherapy. Clin Transl Oncol. (2020) 22:509. 10.1007/s12094-019-02109-8

  • 13.

    WatsonDSKrutzinnaJBruceINGriffithsCEMcInnesIBBarnesMRet al. Clinical applications of machine learning algorithms: beyond the black box. BMJ. (2019) 364:l886. 10.1136/bmj.l886

  • 14.

    ChenRLiuXJinSLinJLiuJ. Machine learning for drug-target interaction prediction. Molecules. (2018) 23:2208. 10.3390/molecules23092208

  • 15.

    LiHYaoLJinPHuLLiXGuoTet al. MRI and PET/CT for evaluation of the pathological response to neoadjuvant chemotherapy in breast cancer: a systematic review and meta-analysis. Breast. (2018) 40:10615. 10.1016/j.breast.2018.04.018

  • 16.

    ZhuQTannenbaumSKurtzmanSHDeFuscoPRicciAJrVavadiHet al. Identifying an early treatment window for predicting breast cancer response to neoadjuvant chemotherapy using immunohistopathology and hemoglobin parameters. Breast Cancer Res. (2018) 20:56. 10.1186/s13058-018-0975-1

  • 17.

    SunRLimkinEJVakalopoulouMDercleLChampiatSHanSRet al. A radiomics approach to assess tumour-infiltrating CD8 cells and response to anti-PD-1 or anti-PD-L1 immunotherapy: an imaging biomarker, retrospective multicohort study. Lancet Oncol. (2018) 19:118091. 10.1016/S1470-2045(18)30413-3

  • 18.

    ShuZFangSDingZMaoDCaiRChenYet al. MRI-based radiomics nomogram to detect primary rectal cancer with synchronous liver metastases. Sci Rep. (2019) 9:3374. 10.1038/s41598-019-39651-y

  • 19.

    WuJAguileraTShultzDGudurMRubinDLLooBWet al. Early-stage non-small cell lung cancer: quantitative imaging characteristics of (18)F fluorodeoxyglucose PET/CT allow prediction of distant metastasis. Radiology. (2016) 281:2708. 10.1148/radiol.2016151829

  • 20.

    WangSKongWAorigeleDengJGaoSZengW. Hybrid feature selection algorithm mRMR-ICA for cancer classification from microarray gene expression data. Comb Chem High Throughput Screen. (2018) 21:42030. 10.2174/1386207321666180601074349

  • 21.

    AlshamlanHBadrGAlohaliY. mRMR-ABC: a hybrid gene selection algorithm for cancer classification using microarray gene expression profiling. BioMed Res Int. (2015) 2015:604910. 10.1155/2015/604910

  • 22.

    HuangYQLiangCHHeLTianJLiangCSChenXet al. Development and validation of a radiomics nomogram for preoperative prediction of lymph node metastasis in colorectal cancer. J Clin Oncol. (2016) 34:215764. 10.1200/JCO.2015.65.9128

  • 23.

    WuYXuLYangPLinNHuangXPanWet al. Survival prediction in high-grade osteosarcoma using radiomics of diagnostic computed tomography. EBioMedicine. (2018) 34:2734. 10.1016/j.ebiom.2018.07.006

  • 24.

    Van CalsterBWynantsLVerbeekJVerbakelJYChristodoulouEVickersAJet al. Reporting and interpreting decision curve analysis: a guide for investigators. Eur Urol. (2018) 74:796804. 10.1016/j.eururo.2018.08.038

  • 25.

    SelliCDixonJMSimsAH. Accurate prediction of response to endocrine therapy in breast cancer patients: current and future biomarkers. Breast Cancer Res. (2016) 18:118. 10.1186/s13058-016-0779-0

  • 26.

    ZhangBTianJDongDGuDDongYZhangLet al. Radiomics features of multiparametric MRI as novel prognostic factors in advanced nasopharyngeal carcinoma. Clin Cancer Res. (2017) 23:425969. 10.1158/1078-0432.CCR-16-2910

  • 27.

    NieKShiLChenQHuXJabbourSKYueNet al. Rectal cancer: assessment of neoadjuvant chemoradiation outcome based on radiomics of multiparametric MRI. Clin Cancer Res. (2016) 22:525664. 10.1158/1078-0432.CCR-15-2997

  • 28.

    YoonHJKimYChungJKimBS. Predicting neo-adjuvant chemotherapy response and progression-free survival of locally advanced breast cancer using textural features of intratumoral heterogeneity on F-18 FDG PET/CT and diffusion-weighted MR imaging. Breast J. (2019) 25:37380. 10.1111/tbj.13032

  • 29.

    ParkSHMoonWKChoNSongICChangJMParkIAet al. Diffusion-weighted MR imaging: pretreatment prediction of response to neoadjuvant chemotherapy in patients with breast cancer. Radiology. (2010) 257:5663. 10.1148/radiol.10092021

  • 30.

    ParkSHMoonWKChoNChangJMImSAParkIAet al. Comparison of diffusion-weighted MR imaging and FDG PET/CT to predict pathological complete response to neoadjuvant chemotherapy in patients with breast cancer. Eur Radiol. (2012) 22:1825. 10.1007/s00330-011-2236-x

  • 31.

    DuanCKallehaugeJFBretthorstGLTanderupKAckermanJJGarbowJR. Are complex DCE-MRI models supported by clinical data?Magn Reson Med. (2017) 77:132939. 10.1002/mrm.26189

  • 32.

    PartridgeSCZhangZNewittDCGibbsJEChenevertTLRosenMAet al. Diffusion-weighted MRI findings predict pathologic response in neoadjuvant treatment of breast cancer: the ACRIN 6698 multicenter trial. Radiology. (2018) 289:61827. 10.1148/radiol.2018180273

  • 33.

    OberijeCNalbantovGDekkerABoersmaLBorgerJReymenBet al. A prospective study comparing the predictions of doctors versus models for treatment outcome of lung cancer patients: a step toward individualized care and shared decision making. Radiother Oncol. (2014) 112:3743. 10.1016/j.radonc.2014.04.012

  • 34.

    BramanNMEtesamiMPrasannaPDubchukCGilmoreHTiwariPet al. Intratumoral and peritumoral radiomics for the pretreatment prediction of pathological complete response to neoadjuvant chemotherapy based on breast DCE-MRI. Breast Cancer Res. (2017) 19:57. 10.1186/s13058-017-0846-1

  • 35.

    GilliesRJKinahanPEHricakH. Radiomics: images are more than pictures, they are data. Radiology. (2016) 278:5637. 10.1148/radiol.2015151169

  • 36.

    LambinPLeijenaarRDeistTMPeerlingsJde JongEvan TimmerenJet al. Radiomics: the bridge between medical imaging and personalized medicine. Nat Rev Clin Oncol. (2017) 14:74962. 10.1038/nrclinonc.2017.141

  • 37.

    SpanheimerPMCarrJCThomasASuggSLScott-ConnerCELiaoJet al. The response to neoadjuvant chemotherapy predicts clinical outcome and increases breast conservation in advanced breast cancer. Am J Surg. (2013) 206:27. 10.1016/j.amjsurg.2012.10.025

  • 38.

    KrishnanYAlawadhiSASreedharanPSGopalMThuruthelS. Pathological responses and long-term outcome analysis after neoadjuvant chemotheraphy in breast cancer patients from Kuwait over a period of 15 years. Ann Saudi Med. (2013) 33:44350. 10.5144/0256-4947.2013.443

  • 39.

    SoussanMOrlhacFBoubayaMZelekLZiolMEderVet al. Relationship between tumor heterogeneity measured on FDG-PET/CT and pathological prognostic factors in invasive breast cancer. PLoS One. (2014) 9:e94017. 10.1371/journal.pone.0094017

  • 40.

    LuoWQHuangQXHuangXWHuHTZengFQWangW. Predicting breast cancer in breast imaging reporting and data system (BI-RADS) ultrasound category 4 or 5 lesions: a nomogram combining radiomics and BI-RADS. Sci Rep. (2019) 9:11921. 10.1038/s41598-019-48488-4

  • 41.

    NgFKozarskiRGaneshanBGohV. Assessment of tumor heterogeneity by CT texture analysis: can the largest cross-sectional area be used as an alternative to whole tumor analysis?Eur J Radiol. (2013) 82:3428. 10.1016/j.ejrad.2012.10.023

Summary

Keywords

radiomics, nomogram, breast cancer, neoadjuvant chemotherapy, pathological complete response, machine learning

Citation

Chen S, Shu Z, Li Y, Chen B, Tang L, Mo W, Shao G and Shao F (2020) Machine Learning-Based Radiomics Nomogram Using Magnetic Resonance Images for Prediction of Neoadjuvant Chemotherapy Efficacy in Breast Cancer Patients. Front. Oncol. 10:1410. doi: 10.3389/fonc.2020.01410

Received

30 November 2019

Accepted

03 July 2020

Published

13 August 2020

Volume

10 - 2020

Edited by

Marco Invernizzi, University of Eastern Piedmont, Italy

Reviewed by

Cristian Scatena, University of Pisa, Italy; Min-Ying Su, University of California, Irvine, United States

Updates

Copyright

*Correspondence: Feng Shao Guoliang Shao

This article was submitted to Women's Cancer, a section of the journal Frontiers in Oncology

†These authors have contributed equally to this work

Disclaimer

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Outline

Figures

Cite article

Copy to clipboard


Export citation file


Share article

Article metrics