Abstract
Among the phencyclidine (PCP) and synthetic cathinone analogs present on the street market, 3-methoxyphencyclidine (3-MeO-PCP) is one of the most popular dissociative hallucinogen drugs, while 3-methylmethcathinone (3-MMC) is a commonly encountered psychostimulant. Numerous 3-MeO-PCP- and 3-MMC-related intoxication cases have been reported worldwide. Identification of the positional isomers of MeO-PCP and MMC families are particularly challenging for clinical and forensic laboratories; this is mostly due to their difficult chromatographic separation (particularly when using liquid chromatography–LC) and similar mass spectrometric behaviors. 3-MeO-PCP and 3-MMC were identified in two powders, detained by two subjects and seized by the police, by different analytical techniques, including liquid chromatography-high-resolution accurate-mass Orbitrap mass spectrometry (LC-HRAM-Orbitrap-MS), and solid deposition gas chromatography-Fourier transform infrared spectroscopy (sd-GC-FTIR). LC-HRAM-Orbitrap-MS allowed us to assign the elemental formulae C18H27NO (MeO-PCP) and C11H15NO (MMC) through accurate mass measurement of the two MH+ ions, and the comparison of experimental and calculated MH+ isotopic patterns. However, MH+ collision-induced product ions spectra were not conclusive in discriminating between the positional isomers [(3-MeO-PCP vs. 4-MeO-PCP) and (3-MMC vs. 4-MMC and 2-MMC)]. Likewise, sd-GC-FTIR easily allowed us to differentiate between the MeO-PCP and MMC positional isomers unambiguously, confirming the presence of 3-MeO-PCP and 3-MMC, due to the high-quality match factor of the experimental FTIR spectra against the target FTIR spectra of MeO-PCP and MMC isomers in a dedicated library. 3-MeO-PCP (in contrast to 3-MMC) was also detected in blood and urine samples of both subjects and analyzed in the context of routine forensic casework by LC-HRAM-Orbitrap-MS following a simple deproteinization step. In addition, this untargeted approach allowed us to detect dozens of phase I and phase II 3-MeO-PCP metabolites in all biological specimens. Analysis of the extracted samples by sd-GC-FTIR revealed the presence of 3-MeO-PCP, thus confirming the intake of such specific methoxy-PCP isomer in both cases. These results highlight the effectiveness of LC-HRAM-Orbitrap-MS and sd-GC-FTIR data in attaining full structural characterization of the psychoactive drugs, even in absence of reference standards, in both non-biological and biological specimens.
Introduction
The new psychoactive substances (NPS) phenomenon, characterized by peculiar features as opposed to the traditional drug phenomena (Peacock et al., 2019; Zamengo et al., 2019), has emerged as a global threat that challenges public health and institutions (UNODC, 2020). Psychoactive and physical effects, toxicity, addiction potential, and potency may vary dramatically among specific NPS. Furthermore, individual products may contain multiple psychoactive ingredients, adulterants, or by-products in extremely variable concentrations, exposing consumers to unpredictable doses of multiple NPS with serious health-related consequences, especially in young people (Zamengo et al., 2014; Orsolini et al., 2019; Larabi et al., 2020). According to their effects, dissociatives, sedatives/hypnotics, synthetic opioids, hallucinogens, synthetic cannabinoid receptor agonists, and psychostimulants are the NPS that most frequently appear on the recreational drug market (UNODC, 2020).
Synthetic cathinones include a very large number of substances with psychostimulant effects, elicited by augmenting central monoamine transmission through release facilitation and/or presynaptic transport inhibition (Simmons et al., 2018). 3-methylmethcathinone (3-MMC) is a commonly encountered synthetic cathinone, introduced in the NPS market to replace mephedrone (4-methylmethcathinone, 4-MMC), and it has seen rapid spread among drug users (Ferreira et al., 2019; Larabi et al., 2019a). 2-methylmethcathinone (2-MMC) has also been reported, albeit more rarely (Nycz et al., 2016). Several 3-MMC-related non-fatal and fatal intoxication cases have been described (Bäckberg et al., 2015b; Jamey et al., 2016; Ameline et al., 2019a; Margasińska-Olejak et al., 2019).
Phencyclidine (PCP)-based compounds are a group of dissociative hallucinogen NPS that exert their primary pharmacologic effect through blockade of excitatory N-methyl-D-aspartate (NMDA) receptors. Additional effects, as relatively weak opioid and dopamine receptor agonists and on serotonergic and noradrenergic pathways, have been described (Morris and Wallach, 2014; Wallach et al., 2014; Wallach and Brandt, 2018). Among the PCP analogs present on the street market, 3-methoxyphencyclidine (3-MeO-PCP) is one of the most popular ones. Even 4-methoxyphencyclidine (4-MeO-PCP) and 2-methoxyphencyclidine (2-MeO-PCP) have been synthesized (Maddox et al., 1965). 4-MeO-PCP is less potent than 3-MeO-PCP, while 2-MeO-PCP is very weak (Kalir, 1981; Wallach and Brandt, 2018), probably explaining why the latter is almost absent from the recreational market. Instead, the relatively large worldwide diffusion of the most potent 3-MeO-PCP represents the cause of many non-fatal and fatal intoxication cases (Stevenson and Tuddenham, 2014; Bäckberg et al., 2015a; Bakota et al., 2016; Bertol et al., 2017; Johansson et al., 2017; Mitchell-Mata et al., 2017; Zidkova et al., 2017; Ameline et al., 2019b; Ameline et al., 2019c; Berar et al., 2019; de Jong et al., 2019; Grossenbacher et al., 2019; Kintz et al., 2019).
Widespread approaches to identification of NPS rely on gas chromatography (GC) or liquid chromatography (LC) separation coupled to mass spectrometry (MS) detection. A major challenge is thus posed by discrimination between regioisomers, in cases where the compounds show identical retention behavior, as well as fragmentation patterns. The combined use of different techniques may be required to gather complementary data supporting the submitted case. In a very recent report on a fatal intoxication case, the simultaneous combination of nuclear magnetic resonance (1H NMR), ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), and GC-MS was deemed as necessary to discriminate the structural isomers of MeO-PCP in the biological specimens of the victim (Berar et al., 2019).
Likewise, Fourier Transform Infrared Spectroscopy (FTIR) can be very specific to the determination of functional groups within unknown samples by measuring small energy differences based on rotational and vibrational amplitudes between individual molecular bonds. In this regard, GC-FTIR data may well complement the information afforded by GC-MS and LC-MS in discriminating between regioisomeric compounds (Lee et al., 2019). Especially on-line techniques relying on the use of direct deposition interfaces enable sensitivity of at least two orders of magnitude more (at the ng scale) than the gas phase devices. Moreover, the sharper IR absorption bands arising from analytes in the solid state result in a significant gain in resolution with respect to spectra acquired from gas molecules (down to 4 cm−1) affected by centrifugal distortion (Schneider and Demirgian, 1986). The usefulness of solid deposition GC-FTIR (sd-GC-FTIR) in forensic laboratories has been demonstrated already for a number of different drug categories contained in seized drugs (Lanzarotta et al., 2017; Cheng and Wong, 2019; Salerno et al., 2020); however the characterization of unknown molecules in biological specimens has never been attempted.
In this paper, we describe the analytical characterization, following two non-fatal intoxication cases, of 3-MMC and 3-MeO-PCP in seized products, and 3-MeO-PCP and its metabolites in biosamples. Different analytical techniques were employed, i.e., GC-MS with electron impact ionization (GC-EI MS), liquid chromatography-high-resolution accurate-mass Orbitrap mass spectrometry (LC-HRAM-Orbitrap-MS), and sd-GC-FTIR. The role of the two latter techniques in attaining full structural characterization of the psychoactive drugs and related metabolites, in both non-biological and biological samples, is highlighted.
Materials and Methods
Chemicals
Water, acetonitrile, formic acid, ethyl acetate, methanol, and 3,4-Methylenedioxy-N-propylamphetamine (MDPA, internal standard, IS) were purchased from Sigma-Aldrich (Milan, Italy); ammonium formate, potassium dihydrogen phosphate, sodium hydroxide, and Bond Elute Certify 130 mg Solid Phase Extraction (SPE) columns were obtained from Agilent Technologies (Santa Clara, CA, United States).
Sample Preparation
Seized Powders
Two white powders, contained in small bags, were seized by the police from two subjects later admitted to two nearby emergency departments because of neurological impairment. Bag labels indicated 3-MMC and 3-MeO-PCP as active ingredients. Police investigations found that both powders were purchased online. For analytical determination, 1 mg of each seized products were dissolved in 1 mL of methanol. About 1 μL of a one-tenth-fold diluted methanol solution was injected into the GC–MS and sd-GC-FTIR systems, whereas 10 μL of a 100-fold diluted methanol:LC mobile phase A (water with 0.05% formic acid and 10 mM ammonium formate) (10:90, v/v) solution were injected in the LC-HRAM-Orbitrap-MS system.
Biological Fluids
An immunoassay toxicological screening for common drugs of abuse and an enzymatic ethanol test were performed in urine and serum samples of both subjects upon hospital admission. For further toxicological tests, whole blood and urine samples were collected from subject A on admission, while plasma and urine samples were collected from subject B when admitted, and whole blood and urine the day after. For LC-HRAM-Orbitrap-MS analysis, 50 µL aliquots of a 2 μg/mL MDPA methanolic solution were poured in conical bottom tubes and evaporated to dryness by gently blowing nitrogen at an ambient temperature. Whole blood, plasma, and urine samples (250 µL each) were subjected to protein precipitation by adding 750 μL of acetonitrile/methanol 2:1 (v/v), previously stored at 4°C, drop by drop while vortexing for 20 s. Precipitated samples were centrifuged at 2,800 rpm for 5 min and the supernatants taken to dryness. The residues were reconstituted with 50 μL aliquots of methanol:LC mobile phase A (10:90, v/v) and transferred to glass inserts contained in 2 mL autosampler vials. Ten μL aliquots of the obtained solutions were injected onto the LC-HRAM-Orbitrap-MS system. For sd-GC-FTIR analysis, urine samples (0.5 mL each) were diluted with 6 mL of 0.1 M phosphate buffer and extracted on Bond Elute Certify 130 mg SPE columns. The obtained eluates were taken to dryness by gently blowing nitrogen at ambient temperature. The residues were reconstituted with 15 μL of methanol and transferred to glass inserts contained in 2 mL autosampler vials. One μL aliquots of the methanolic solutions were injected into the sd-GC-FTIR system.
GC-EI MS
GC-EI MS analyses of the seized powders were carried out as previously published (Frison et al., 2016b). Briefly, an Agilent 7890 series II/5975 GC/MS quadrupole mass spectrometer operating with electron ionization (EI, 70 eV) in full scan (m/z 40–600) acquisition mode (Agilent Technologies, Cernusco sul Naviglio, Italy) was used. The capillary column was an Agilent HP-5MS UI (ultra inert, 30 m × 0.25 mm, 0.25 μm film thickness), and the oven temperature was programmed from 50 to 300°C. Compounds were identified by comparison within the SWGDRUG MS Library version 3.6 (available at http://www.swgdrug.org/ms.htm), containing over 3,000 EI mass spectra of drugs and drug-related compounds.
LC-HRAM-Orbitrap-MS
LC-HRAM-Orbitrap-MS analyses of both non-biological and biological specimens were carried out employing the analytical conditions previously published for the characterization of several NPS (Frison et al., 2015; Frison et al., 2016a; Frison et al., 2016b; Papa et al., 2019). Briefly, powder solutions and biosample extracts were analyzed using a Thermo Scientific Accela 1250 UHPLC system equipped with a Hypersil Gold PFP analytical column (2.1 mm × 100 mm, 1.9 µm particle size), coupled to a Thermo Scientific single-stage Exactive HCD MS system, interfaced with an HESI-II source. Mobile phase A was water with 0.05% formic acid and 10 mM ammonium formate, and mobile phase B was acetonitrile with 0.05% formic acid. The flow rate was set to 400 μL/min. The mobile phase gradient was as follows: 99% A for 1 min, linear gradient to 70% B in 6.5 min, linear gradient to 100% B in 1 min, held for 5.0 min, and column re-equilibration was performed with linear gradient to 99% A in 0.5 min, held for 3.0 min. MS was performed in positive-ion mode with a scan range from m/z 50 to 800, alternating full scan (HCD off, resolution of 100,000 FWHM at m/z 200) and “all-ion fragmentation” (AIF) (HCD on, collision energies 10, 25, and 50 eV, resolution of 25,000 FWHM at m/z 200) acquisition. External mass calibration was performed, according to the guidelines provided by the instrument supplier, every 2 days over the mass range m/z 130–2,000. Data were acquired and processed using Thermo Scientific Excalibur software version 2.1.0.
sd-GC-FTIR
GC separations of seized powders and biological specimens were performed on a Nexis GC-2030 gas chromatograph equipped with an AOC-20i autosampler (Shimazdu, Kyoto, Japan) coupled to a DiscovIR solid deposition FTIR detector (Spectra-Analysis Instrument Inc., Marlborough, MA, United States). A Supelco SLB-5ms column (30 m × 0.25 mm, 0.25 μm film thickness) was employed for the separation (Merck KGaA, Darmstadt, Germany), using helium (purity 99.99%) as a carrier gas, at a constant linear velocity of 30 cm/s. The 1 μL samples were injected in splitless mode (1.50 min sampling time) at an injector temperature of 280°C. The oven temperature program was set to 100°C for 2 min before being ramped to 350°C at 15°C/min. The final temperature was held for 5.0 min, resulting in total analysis times of 24.0 min.
The end of the column was connected to a deactivated fused silica capillary through a micro Siltite µ-union (Trajan Scientific and Medical, Milton Keynes, United Kingdom) and inserted into a heated transfer line connected to the IR interface. The transfer line and restrictor temperatures were set at 280°C. Blanks were run in between samples to assure that the liner and column were free of contamination. The restrictor was positioned directly above a ZnSe disk, which was chilled down to −50°C by means of liquid nitrogen, and cleaned daily with acetone. The DiscovIR FTIR instrument was equipped with a Mercury-Cadmium-Telluride (MCT) cryogenically cooled detector. Solid-phase IR spectra of the GC eluted compounds were recorded in real time from 100 μm × 100 μm spots in the 650–4,000 cm−1 range, with a resolution of 4 cm−1 and a scan rate of 2 Hz, at a disc rotation speed of 3 mm/min. GC-FTIR data acquisition and processing were performed using the Thermo Galactic GRAMS/AI (version 9.3) spectroscopy and chromatography software. Compounds were identified through the library search program (Spectral ID), using a first derivative correlation algorithm, by comparison within a homemade solid deposition IR spectral library containing IR spectral data of around 600 NPS (namely, Controlled and Prohibited Substances version 1.0).
Results and Discussion
Identification of synthetic cathinone and PCP analogs, and in particular identification of positional isomers of the MMC and MeO-PCP families, may be particularly challenging for clinical and forensic laboratories. MMC and MeO-PCP analogs may show quite similar chromatographic and, especially, mass spectrometric behaviors, which may hinder their full characterization in the case of unavailability of reference standards for all isomers, and/or their metabolites in case of biosample analysis. These analytical challenges have been addressed by several authors by means of different analytical approaches, for the discrimination of 2-MMC, 3-MMC, and 4-MMC (Power et al., 2011; Power et al., 2012; Jamey et al., 2016; Maas et al., 2017; Zuba and Adamowicz, 2017; Nowak et al., 2018; Kranenburg et al., 2019; Kranenburg et al., 2020a; Kranenburg et al., 2020b) and 3-MeO-PCP and 4-MeO-PCP (Bäckberg et al., 2015a; Bakota et al., 2016; Bertol et al., 2017; Johansson et al., 2017; Mitchell-Mata et al., 2017; Zidkova et al., 2017; Ameline et al., 2019b; Berar et al., 2019; de Jong et al., 2019; Kintz et al., 2019). However, such discriminative analyses were in most cases carried out with all the necessary reference standards available. We attained the full identification of the two NPS under study, in both non-biological (3-MMC and 3-MeO-PCP) and biological (3-MeO-PCP) specimens, through a combination of GC-EI MS, LC-HRAM-Orbitrap-MS, and sd-GC-FTIR, without resorting to specific reference standards. In particular, reliable results obtained from searching into dedicated spectral libraries allow for confident compound identification to be attained even if the reference material is not at hand.
Analysis of Seized Powders
3-MMC and 3-MeO-PCP were putatively identified in the two seized powders through comparison of their GC-EI MS spectra with those of the SWGDRUG library and 3-MMC and 4-MMC reference standards, as, at the time of case processing, no 2-MMC and MeO-PCP standards were available (Figure 1). As a matter of fact, the identification of MMC and MeO-PCP positional isomers was not conclusive by GC-MS alone. Actually, isomers of the two chemical families may show similar EI spectra. For instance, 4-MMC, 3-MMC, and 2-MMC EI spectra are hardly distinguishable due to their extreme similarity (Power et al., 2011; Zuba and Adamowicz, 2017); they are in all cases characterized by the barely visible molecular ions at m/z 177, not abundant fragment ions at m/z 162, 119, 91, 65, and 56 and the unspecific base peak at m/z 58, caused by the well-known formation of the immonium ion via the amine-initiated alpha-cleavage of the benzylic bond, characteristic of all N-methyl phenethylamines (Frison et al., 2011). Also, 3-MeO-PCP and 4-MeO-PCP are hardly distinguishable by their EI spectra (Bertol et al., 2017; Mitchell-Mata et al., 2017; Kintz et al., 2019).
FIGURE 1
Regarding LC-HRAM-Orbitrap-MS analysis of the two seized powders, Figures 2, 3 show the extracted ion chromatograms at m/z 178.1226 (MMC MH+ ions) and 274.2165 (MeO-PCP MH+ ions) of the full scan ion traces without fragmentation, the corresponding MMC and MeO-PCP full scan mass spectra and related MH+ collision-induced product ion spectra obtained in AIF conditions (HCD on, 25 eV), as well as the experimental and calculated isotopic patterns of MMC and MeO-PCP MH+ ions, obtained from the LC-HRAM-Orbitrap-MS analysis of the first and the second seized powder, respectively. Accurate mass measurements of the two MH+ ions had a mass accuracy [Δm = (accurate mass − exact mass)/exact mass × 106] of +0.56 and −0.36 ppm for MMC and MeO-PCP, respectively. Fully superimposable experimental and calculated MH+ isotopic patterns were obtained for the two substances, with relative isotopic abundance (RIA, M+1/M+0 ion abundances) error values (expressed as experimental RIA–calculated RIA)/calculated RIA×100) of −4.11 and −2.18% for MMC and MeO-PCP, respectively. Hence, LC-HRAM-Orbitrap-MS measurements allowed us to assign the elemental formulae C11H15NO (MMC) and C18H27NO (MeO-PCP) for the two MH+ ions. However, MH+ collision-induced product ions spectra, although in agreement with those already described (Bakota et al., 2016; Frison et al., 2016a; Michely et al., 2017; Zidkova et al., 2017), were once again not conclusive in discriminating between the positional isomers [(3-MMC vs. 4-MMC and 2-MMC) and (3-MeO-PCP vs. 4-MeO-PCP)] without using reference standards, as even in these analytical conditions fragment ions sporting the same mass and similar abundances may be obtained from MH+ ions of individual MMC (Maas et al., 2017; Zuba and Adamowicz, 2017) and MeO-PCP (Bakota et al., 2016; Bertol et al., 2017; Zidkova et al., 2017) analogs.
FIGURE 2
FIGURE 3
Conversely, sd-GC-FTIR allowed us to identify MMC and MeO-PCP positional isomers unambiguously, confirming the presence of 3-MMC in the first seized powder and 3-MeO-PCP in the second seized powder. Confident discrimination of the positional isomers was possible based on the high quality match factor (QMF) of the experimental FTIR spectra against the target FTIR spectra upon searching in a dedicated solid-phase GC-FTIR library. The sharp absorption bands in FTIR spectra obtained from solid deposited analytes allow us to easily differentiate between very similar compounds, as shown in Figure 4 for 3-MMC, 4-MMC, and 2-MMC. For identification purposes, the experimental GC-FTIR spectrum obtained for the cathinone compound contained in the first seized powder was searched into a solid-phase GC-FTIR library containing IR spectral data of NPS (supplied by the vendor). A QMF criterion was adopted, based on quantitative evaluation of IR spectral data, as an unbiased criterion to achieve unambiguous compound identification. Thus, 3-MMC could be identified in the sample, ranking as Hit #1 in the library search result, with a QMF of 91.6%. Noticeably, much lower QMF values were obtained for the two incorrect matches, viz. 14.2% for the 4-substituted cathinone (4-MMC) and 11.0% for the 2-substituted isomer (2-MMC). It is also worth underlining that 4-MMC did not rank in the second hit position, as one could expect, but showed up as Hit #21, after a long list of candidates, and isomer 2-MMC was Hit #33.
FIGURE 4
In a similar way, the great specificity of molecule/bond-related information contained in the GC-FTIR spectrum allowed for a definite identification of the illicit drug constituent of the second seized powder, i.e., 3-MeO-PCP. Again, a high QMF differential was obtained between the correct and the (closest) incorrect match, i.e., the 3-methoxy-substituted phencyclidine and the 4-substituted isomer, thanks to distinctive spectral features especially in the fingerprint region to the right hand side of Figure 5 (below 1,500 cm−1). In detail, 3-MeO-PCP was found as Hit #1, with a QMF of 96.1%, while 4-MeO-PCP showed up as Hit #8, and with only 14.6% of a QMF. The significant gap in library search results would in turn reduce the likelihood for false positives and increase confidence in the identification. In more detail, the compounds that match in the library search between the 1st and 21st hit for MMC were as follows: 3-Methylmethcathinone (Hit 1), 3-Methylethcathinone (Hit 2), 3-Ethylmethcathinone (Hit 3), Pentedrone (Hit 4), N-Methylbenzedrone (Hit 5), 4-Chloropentedrone (Hit 6), Ethcathinone (Hit 7), N-Ethylbuphedrone (Hit 8), 4-Methylcathinone (Hit 9), Cathinone (Hit 10), 3′,4′-Tetramethylene-alpha-pyrrolidinovalerophenone (Hit 11), 4-Bromomethcathinone (Hit 12), α-Isopropylamino-valerophenone (Hit 13), 4-Ethylmethcathinone (Hit 14), 3-Fluoromethcathinone (Hit 15), N-Ethylhexedrone (Hit 16), 4-Methyldiethcathinone (Hit 17), 3′,4′-Tetramethylene-α-pyrrolidinobutiophenone (Hit 18), 4-Fluorobuphedrone (Hit 19), 4- Chloroethcathinone (Hit 20), and 4-Methylmethcathinone (Hit 21). The compounds that match in the library search between the first and eighth hit for MeO-PCP were as follows: 3-Methoxyphencyclidine (Hit 1), 3-Methoxyeticyclidine (Hit 2), Cannabicyclohexanol (Hit 3), Diphenidine (Hit 4), 4-[1-(3-Methoxyphenyl)cyclohexyl]morpholine (Hit 5), 5b-Androstane-3a,17b-diol (Hit 6), 4′-Methyl-2-piperidinopropiophenone (Hit 7), and 4-Methoxyphencyclidine (Hit 8).
FIGURE 5
Analysis of Biological Fluids
All immunoassay toxicological screening for common drugs of abuse (not including PCP) performed in urine and serum samples were negative, which is the same as what occurred in other cases (Berar et al., 2019). If the immunoassay screening had included the PCP test (not a routine test in most European toxicology laboratories), a positive result would probably have been obtained considering the cross-reactivity of MeO-PCP analogs in several PCP immunoassay systems (Bäckberg et al., 2015a; Bakota et al., 2016; Chang and Smith, 2017; Mitchell-Mata et al., 2017; Gomila et al., 2019; Larabi et al., 2019b). Enzymatic ethanol tests were also negative in both cases.
Whole blood and urine samples collected from subject A, as well as whole blood, plasma, and urine samples collected from subject B on two consecutive days, were subjected to LC-HRAM-Orbitrap-MS analysis following a simple and rapid deproteinization step. 3-MeO-PCP was detected in all biosamples of both subjects, while no 3-MMC nor its metabolites dihydro-3-MMC (3-methylephedrine), nor-dihydro-3-MMC (3-methylnorephedrine), nor-3-MMC, hydroxytolyl-3-MMC, nor-hydroxytolyl-3-MMC, carboxy-3-MMC, carboxy-dihydro-3-MMC (Pedersen et al., 2013; Frison et al., 2016a) were detected in the samples from both subjects. This suggests that, of the two powders seized by police, only the one containing 3-MeO-PCP had been taken. No other NPS, traditional illicit drugs, or medications (other than those administered at the hospitals) were detected in both cases.
In addition, the comprehensive, untargeted, and sensitive analytical approach, consisting of generic sample preparation (a simple deproteinization step) and full scan MS detection in the high-resolution mode, allowed us to detect more than 20 phase I and 10 phase II 3-MeO-PCP metabolites in all biological specimens. Identification of metabolites was based on the following: 1) evaluation of their chromatographic behavior compared to the parent compound; 2) accurate mass measurements of their MH+ ions in full scan conditions; 3) evaluation of their MH+ isotopic patterns, including mass accuracy of MH+ (M+0, M+1, M+2, M+3) isotopic peaks; 4) accurate mass measurements of MH+ collision-induced productions (at three collision energies, 10, 25, 50 eV); and, above all, 5) comparison with analytical results obtained with similar LC-HRAM-Orbitrap-MS instruments, reported in recently published papers dealing with 3-MeO-PCP metabolic studies on rat urine and human liver preparations (Michely et al., 2017), and a molecular networking approach application in a case of 3-MeO-PCP intoxication (Allard et al., 2019). In these studies, numerous phase I metabolites (related to 3-MeO-PCP multiple aliphatic hydroxylations at the cyclohexyl ring and the heterocyclic ring, single aromatic hydroxylation, carboxylation after ring opening, O-demethylation) and corresponding phase II glucuronide metabolites have been identified.
All equivalent analytical data from the present study are listed in detail in Table 1, as they may become supposedly helpful to other toxicologists in case of further 3-MeO-PCP intoxication cases. All phase I and phase II metabolites, being more hydrophilic and polar, elute at shorter retention times than the parent compound under the reported LC conditions, as previously described (Michely et al., 2017; Zidkova et al., 2017; Allard et al., 2019; Ameline et al., 2019c). Experimental isotopic patterns of each metabolite were in total agreement with the theoretical ones [MH+ (M+0) Δm values range from 0 to 1.37 ppm; (M+1) values from 0 to 1.19 ppm; (M+2) values from 0 to 2.76 ppm; (M+3) values from −0.82 to 4.20 ppm], and MH+ fragment ions, identified in variable numbers for each metabolite, mirrored those described in the above papers. Some values, mainly related to fragment ions, are missing due to the very low abundance of the specific metabolites. Typical full scan mass spectra, MH+ collision-induced product ion spectra obtained applying the three different (10, 25, 50 eV) collision energies, as well as experimental and calculated isotopic patterns, related to one phase I [piperidine-di-OH- (M1h)] and one phase II [O-demethyl-glucuronide- (M2a)] urinary metabolites, are shown in Figures 6 and 7. Similar results are shown in the Supplementary Figures S1 and S2 for the O-demethyl- (M1a), O-demethyl-piperidine-OH- (M1b), and O-demethyl-piperidine-di-OH- (M1g) phase I metabolites as well as the O-demethyl-piperidine-OH-glucuronide- (M2c) phase II metabolite.
TABLE 1
| 3-MeO-PCP Metabolite(s) | Acronym | MH+ elemental composition | tR (min) | Exact mass, accurate mass, mass accuracy | MH+ product ions | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| M+0 (MH+) | M+1 | M+2 | M+3 | n. 1 | n. 2 | n. 3 | n. 4 | n. 5 | n. 6 | n. 7 | ||||
| 3-MeO-PCP | 3-MeO-PCP | C18H28NO | 7.74 | 274.2165 274.2164 −0.36 ppm | 275.2199 275.2198 −0.36 ppm | 276.2233 276.2231 −0.72 ppm | 277.2266 277.2266 0 ppm | 189.1272 | 121.0647 | 95.0492 | 91.0543 | 86.0965 | 81.0700 | - |
| O-demethyl- | M1a | C17H26NO | 6.42 | 260.2009 260.2008 −0.38 ppm | 261.2042 261.2041 −0.38 ppm | 262.2076 262.2074 −0.76 ppm | 263.2110 263.2109 −0.38 ppm | 175.1115 | 107.0491 | 95.0492 | 91.0542 | 86.0965 | 81.0700 | 79.0544 |
| O-demethyl-piperidine-OH- | M1b | C17H26NO2 | 5.49 | 276.1958 276.1956 −0.72 ppm | 277.1992 277.1990 −0.72 ppm | 278.2025 278.2023 −0.72 ppm | 279.2059 279.2061 0.72 ppm | 175.1113 | 107.0490 | 102.0912 | 95.0491 | 84.0808 | 81.0699 | 77.0388 |
| O-demethyl-cyclohexyl-HO- | M1c | C17H26NO2 | 4.55 5.01* 5.09 | 276.1958 276.1958 0 ppm | 277.1992 277.1992 0 ppm | 278.2025 278.2025 0 ppm | 279.2059 279.2057 −0.72 ppm | 173.0959 | 107.0491 | 86.0966 | 79.0544 | 77.0387 | - | - |
| O-demethyl-cyclohexyl-HO-dehydro-oxo-piperidine- | M1d | C17H22NO3 | 5.30 | 288.1594 288.1592 −0.69 ppm | 289.1628 289.1625 −1.04 ppm | 290.1661 290.1653 −2.76 ppm | - | 98.0601 | - | - | - | - | - | - |
| Piperidine-HO- | M1e | C18H28NO2 | 6.68 | 290.2115 290.2112 −1.03 ppm | 291.2148 291.2146 −0.69 ppm | 292.2182 292.2180 −0.68 ppm | 293.2215 293.2211 −1.36 ppm | 189.1274 | 121.0648 | 102.0914 | 91.0543 | 84.0809 | 81.0701 | - |
| Cyclohexyl-HO- isomers | M1f | C18H28NO2 | 5.62* 6.18 6.34 | 290.2115 290.2112 −1.03 ppm | 291.2148 291.2146 −0.69 ppm | 292.2182 292.2179 −1.03 ppm | 293.2215 293.2211 −1.36 ppm | 205.1221 | 187.1116 | 121.0647 | 91.0543 | 86.0965 | 79.0544 | 77.0387 |
| O-demethyl-piperidine-di-HO- | M1g | C17H26NO3 | 5.88 | 292.1907 292.1903 −1.37 ppm | 293.1941 293.1938 −1.02 ppm | 294.1974 294.1971 −1.02 ppm | 295.1983 295.1977 −2.03 ppm | 175.1114 | 118.0860 | 107.0490 | 101.0597 | 81.0699 | 79.0544 | 77.0387 |
| Piperidine-di-HO- | M1h | C18H28NO3 | 6.95 | 306.2064 306.2061 −0.98 ppm | 307.2097 307.2094 −0.98 ppm | 308.2131 308.2129 −0.65 ppm | 309.2140 309.2136 −1.29 ppm | 189.1270 | 121.0646 | 118.0861 | 101.0597 | 100.0757 | 91.0543 | 81.0700 |
| Cyclohexyl-HO-piperidine-HO- isomers | M1i | C18H28NO3 | 4.45* 5.15 5.33 | 306.2064 306.2063 −0.33 ppm | 307.2097 307.2096 −0.33 ppm | 308.2131 308.2131 0 ppm | 309.2140 309.2127 −4.20 ppm | 187.1114 | 121.0647 | 102.0914 | 84.0808 | - | - | - |
| O-demethyl-cyclohexyl-HO-piperidine-di-HO- | M1k | C17H26NO4 | 4.72 | 308.1856 308.1856 0 ppm | 309.1890 309.1889 −0.32 ppm | 310.1923 310.1921 −0.64 ppm | - | 191.1064 | 173.0958 | 118.0861 | 101.0597 | - | - | - |
| Carboxy- methyl artifact | M1m | C19H30NO3 | 7.86 | 320.2220 320.2217 −0.94 ppm | 321.2254 321.2251 −0.93 ppm | 322.2287 322.2285 −0.62 ppm | 323.2296 323.2297 0.31 ppm | 189.1271 | 132.1017 | 115.0753 | - | - | - | - |
| O-(demethyl-carboxy-cyclohexyl-HO-) methyl artifact | M1n | C18H28NO4 | 5.73 | 322.2013 322.2010 −0.93 ppm | 323.2046 323.2044 −0.62 ppm | 324.2080 324.2075 −1.54 ppm | - | - | - | - | - | - | - | - |
| Cyclohexyl-OH-piperidine-di-OH- | M1o | C18H28NO4 | 5.04 | 322.2013 322.2012 −0.31 ppm | 323.2046 323.2045 −0.31 ppm | 324.2080 324.2081 0.31 ppm | 325.2089 325.2079 −3.07 ppm | 187.1115 | 118.0860 | 100.0756 | - | - | - | - |
| Carboxy-cyclohexyl-HO- methyl artifact isomers or Carboxy-alkyl-OH- | M1p | C19H30NO4 | 7.52 7.69* 8.23 | 336.2169 336.2166 −0.89 ppm | 337.2203 337.2199 −1.19 ppm | 338.2236 338.2230 −1.77 ppm | - | - | - | - | - | - | - | - |
| O-demethyl- glucuronide | M2a | C23H34NO7 | 4.47 | 436.2330 436.2326 −0.92 ppm | 437.2363 437.2359 −0.91 ppm | 438.2397 438.2398 0.23 ppm | 439.2406 439.2398 −1.82 ppm | 175.1114 | 107.0490 | 95.0128 | 86.0964 | 81.0700 | 79.0544 | - |
| O-demethyl-aryl-OH glucuronide | M2b | C23H34NO8 | 3.41 | 452.2279 452.2274 −1.11 ppm | 453.2312 453.2310 −0.44 ppm | 454.2346 454.2346 0 ppm | 455.2355 455.2344 −2.42 ppm | 191.1063 | 173.0958 | 107.0490 | 86.0964 | 79.0543 | - | - |
| O-demethyl-piperidine-OH- glucuronide | M2c | C23H34NO8 | 4.07 | 452.2279 452.2275 −0.88 ppm | 453.2312 453.2310 −0.44 ppm | 454.2346 454.2346 0 ppm | 455.2355 455.2346 −1.98 ppm | 175.1114 | 107.0490 | 102.0913 | 84.0808 | 81.0699 | - | - |
| O-demethyl-aryl-OH-dihydropyridine-OH- glucuronide | M2d | C23H30NO9 | 4.20 | 464.1915 464.1914 −0.22 ppm | 465.1949 465.1947 −0.43 ppm | 466.1982 466.1982 0 ppm | 467.1991 467.1987 −0.86 ppm | 173.0958 | 98.0601 | 79.0545 | - | - | - | - |
| Piperidine-OH glucuronide | M2e | C24H36NO8 | 5.54 | 466.2435 466.2429 −1.29 ppm | 467.2469 467.2465 −0.86 ppm | 468.2503 468.2501 −0.43 ppm | 469.2511 469.2501 −2.13 ppm | 278.1227 | 189.1270 | 121.0646 | 102.0913 | 85.0284 | 84.0808 | 81.0700 |
| O-demethyl-cyclohexyl-HO-piperidine-HO- glucuronide | M2f | C23H34NO9 | 3.77 | 468.2228 468.2226 −0.43 ppm | 469.2262 469.2258 −0.85 ppm | 470.2295 470.2294 −0.21 ppm | 471.2304 471.2298 −1.27 ppm | - | - | - | - | - | - | - |
| O-demethyl-piperidine-di-OH- glucuronide | M2g | C23H34NO9 | 4.44 | 468.2228 468.2225 −0.64 ppm | 469.2262 469.2259 −0.64 ppm | 470.2295 470.2293 −0.43 ppm | 471.2304 471.2295 −1.91 ppm | 145.0657 | 107.0490 | 84.0808 | 79.0543 | - | - | - |
| Cyclohexyl-HO-piperidine-HO- glucuronide | M2h | C24H36NO9 | 4.53 | 482.2385 482.2382 −0.62 ppm | 483.2418 483.2416 −0.41 ppm | 484.2452 484.2449 −0.62 ppm | 485.2461 485.2465 0.82 ppm | 187.1115 | 159.0802 | 121.0647 | 102.0914 | 84.0809 | - | - |
| Piperidine-di-OH- glucuronide | M2i | C24H36NO9 | 5.93 | 482.2385 482.2379 −1.24 ppm | 483.2418 483.2414 −0.83 ppm | 484.2452 484.2449 −0.62 ppm | 485.2461 485.2460 −0.21 ppm | 121.0646 | 118.0861 | - | - | - | - | - |
Chromatographic and mass spectrometric data of 3-MeO-PCP and its phase I and phase II metabolites identified in the biological specimens under study.
Mass accuracy (Δm) = (accurate mass − exact mass)/exact mass × 106.
In case of isomers MS data refer to the most abundant one (*).
Missing values (-) in some “isotopic pattern” or “product ion” columns are due to the very low abundance of some metabolites.
FIGURE 6
FIGURE 7
Although a great number of metabolites have been identified and listed in Table 1, a selection of compounds can be chosen to represent the main targets for an LC-(HR)MS screening of biofluids in case of suspected 3-MeO-PCP intoxication. Therefore, a specific instrumental layout covering the seven most abundant analytes for urine (and whole blood, barring the M1g metabolite) samples was arranged. Urinary metabolites other than the seven chosen all had minor abundances. Figures 8 and 9 show the application of this layout, displaying the corresponding ion chromatograms of 3-MeO-PCP, the chosen phase I (M1a, M1b, M1g, and M1h) and phase II (M2a and M2c) metabolites, and the IS MDPA, obtained from whole blood and urine extracts, respectively, which were collected at the same time from the same subject (subject A in this case). Judging by the absolute and percent area values of compound peaks shown in the Figures, the relative abundances of both whole blood and urine 3-MeO-PCP and metabolite M1h (piperidine-di-OH-) were consistent with corresponding results reported by Allard et al. (2019). Roughly the same, as far as urine is concerned, for the abundance ratio of M1a (O-demethyl-) to M1h (piperidine-di-OH-) metabolites, as well as abundance ratio of M2a (O-demethyl-glucuronide) to M2c (O-demethyl-piperidine-OH-glucuronide) metabolites. Moreover, differently from what is reported by Ameline et al. (2019c), elevated urinary metabolite-to-parent drug ratios were found here for some metabolites (M1g, M1h, and M2a), and this may be considered advantageous to increase the detection windows in intoxication cases. However, this was not the case with subject B, whose day 1 urine showed a higher abundance of parent compound compared to most metabolites. Hence, in these two cases, among other variables, different drug intake times may be hypothesized for the two subjects since, as widely known and already pointed out (Ameline et al., 2019c), metabolite ratios change during the parent drug excretion curve. Also, it should be considered that results from autopsy samples (Ameline et al., 2019c) may not be comparable with results from non-fatal cases, as those described here. As expected, analyte concentrations of biosamples collected from subject B were higher on hospital admission than on day 2 (data not shown). Whole blood 3-MeO-PCP quantitative analysis was not carried out due to 3-MeO-PCP reference standard unavailability at the time of case processing.
FIGURE 8
FIGURE 9
As further identification means, sd-GC-FTIR was applied for the analysis of SPE-extracted urine samples from both subjects. The presence of 3-MeO-PCP was revealed in both cases, thus proving, in conjunction with LC-HRAM-Orbitrap-MS, the intake of such specific methoxy-PCP isomer by both subjects. A first GC-FTIR analysis of urine samples from both subjects did not yield satisfactory results, given the presence of a high number of different metabolites of the parent drug, all showing up as peaks of much higher abundance with respect to the compound under investigation (data shown in Supplementary Figure S3). In accordance with the results from LC-HRAM-Orbitrap-MS, the GC-FTIR peak corresponding to 3-MeO-PCP in a urine sample from patient B revealed much higher intensity than the corresponding one in subject A urine sample, with absorption intensities in the mid-IR region of 0.01 and 0.0032, respectively (data shown in Supplementary Figure S3). In both cases, the amount of analyte being deposited on the IR-transparent disc after GC separation was not sufficient to provide a full informative FTIR spectrum for identification purposes. This was reflected in the low QMF value obtained from searching the experimental spectra in a home-made solid-phase GC-FTIR library, which was equal to 13 for identification of 3-MeO-PCP in a urine sample from subject A. In order to enhance analyte detectability and further obtain confident identification of the target compound, concentrated deposits were obtained through multiple sample deposition. As expected, multiple deposits of the GC-eluted analyte from consecutive runs overlaid on the disc, afforded an increase in the signal-to-noise ratio, as shown in Figure 10. The similarity score, in terms of QMF, has increased to 80 after five consecutive depositions of the analyte, and progressively reached a value >90 after the ninth deposition was accomplished (data shown in Supplementary Figure S4). This is related to a key validation parameter in spectroscopic measurements, defined as the limit of identification (LOI), and representing the lowest analyte concentration that yields a library searchable IR spectrum. Beyond the more common concept of Limit of Detection (LOD), LOI ultimately defines quantitatively the possibility for reliable identification of an unknown compound, contained at a certain amount in a given sample, and often in the presence of a noisy background (Salerno et al., 2020). As the result, 3-MeO-PCP was identified in the urine sample from subject A, with a QMF of 90.4 (Hit #1, correct match) vs. a QMF of 18 for the 4-MeO-PCP isomer (Hit #7, incorrect match).
FIGURE 10
Due to the higher concentration of the target 3-Meo-PCP analyte, only two consecutive depositions were sufficient in the case of a urine sample from subject B, for a QMF increase from 70 (first GC-FTIR analysis) to >90 (second deposition). As for the previous case, a high QMF differential was obtained here too, between the correct (3-MeO-PCP) and the incorrect (4-MEO-PCP) match, viz. 92.9 vs. 12.2.
Conclusion
The results described in this paper highlight the effectiveness of LC-HRAM-Orbitrap-MS and sd-GC-FTIR in attaining the full structural characterization of 3-MMC and 3-MeO-PCP in seized products, the identification of 3-MeO-PCP and numerous phase I and phase II metabolites in blood, plasma, and urine samples of both cases, and the discrimination between the MMC and MeO-PCP positional isomers [(3-MMC vs. 4-MMC and 2-MMC) and (3-MeO-PCP vs. 4-MeO-PCP)] in both non-biological and biological specimens.
Advanced MS techniques, such as LC-HRAM-Orbitrap-MS, represent valuable analytical tools in forensic toxicology, allowing for highly specific and sensitive untargeted or targeted drug detection in both seized materials and biological fluids. An outstanding analytical specificity is currently attainable; it is allowable through the accurate mass measurement of ionic species, the comparison of experimental and calculated isotopic patterns, and the study of collision-induced product ions obtained in high-resolution conditions. Furthermore, the application of HRMS measurements in full scan conditions avoids the drawbacks of the pre-selection of ions, as in Selected Ion Monitoring (SIM) or Multiple Reaction Monitoring (MRM) acquisition modes. Also, full-scan data may be always retrospectively processed, without resorting to new sample preparation and analytical runs.
Solid-phase GC-FTIR has proven to be an effective tool to widespread MS-based approaches, for achieving unequivocal identification of NPS, even in the case of regioisomers, having identical nominal masses, and yielding the same fragments upon dissociation. Noticeably, confident discrimination between 3-MeO-PCP and related isomers could be achieved from much lower analyte amounts (1 μg powder containing the molecule) compared to NMR approaches, which typically require mg-level quantities (Ameline et al., 2019b). Apart from the seized sample analysis, the application of sd-GC-FTIR to human urine samples demonstrated the usefulness of the technique for the investigation of biosamples of clinical and forensic toxicological concern. Thus, even in the absence of the powder, sd-GC-FTIR analysis of biological samples would have been sufficient to clarify the existence of a specific MeO-PCP positional isomer. Compared to the application of single GC, LC, and MS techniques for the discrimination of MMC and MeO-PCP analogs in non-biological drug samples, which can be problematic due to their quite similar chromatographic and, especially, mass spectrometric, behaviors (Berar et al., 2019), the application of sd-GC-FTIR affords unambiguous identification of positional isomers.
Statements
Data availability statement
Due to legal reasons (analytical investigations requested by police for forensic purposes) the raw analytical data supporting the conclusions of this article are not publicly and indiscriminately available. They will be made available by the authors to qualified researchers only, on strictly specific and motivated instances. Any requests to access the raw data should be directed to the corresponding author.
Ethics statement
Ethical review and approval was not required for the study on human participants in accordance with the local legislation and institutional requirements. Written informed consent for participation was not required for this study in accordance with the national legislation and the institutional requirements.
Author contributions
GF, PD, and LM: conception and design. FZ, SF, LQ, MA, FV, GG, and TS: acquisition of data. GF, FZ, SF, LQ, MA, FV, GG, TS, and PD: analysis and interpretation of data. GF and PD: drafting the article. All authors: contributed to the article and approved the submitted version.
Acknowledgments
The Laboratory of Environmental Hygiene and Forensic Toxicology, DMPO Department, AULSS 3 (Venice, Italy) gratefully acknowledges the invaluable help of Arianna Negro in analytical data processing and manuscript revision.
Conflict of interest
Author TS was Technical Director of the company BeSep S.r.l. Author LM was Member of the Scientific Committee of the company BeSep S.r.l. and Scientific Member of the Board of Directors of Chromaleont S.r.l.
The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Supplementary material
The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fchem.2020.618339/full#supplementary-material.
References
1
AllardS.AllardP. M.MorelI.GicquelT. (2019). Application of a molecular networking approach for clinical and forensic toxicology exemplified in three cases involving 3-MeO-PCP, doxylamine, and chlormequat. Drug Test. Anal.11, 669–677. 10.1002/dta.2550
2
AmelineA.Dumestre-TouletV.RaulJ.-S.KintzP. (2019a). Abuse of 3-MMC and forensic aspects: about 4 cases and review of the literature. Toxicol. Anal. et Clin.31, 251–257. 10.1016/j.toxac.2018.11.001
3
AmelineA.GarnierD.GheddarL.RichevalC.GaulierJ. M.RaulJ. Set al (2019b). Identification and analytical characterization of seven NPS, by combination of 1H NMR spectroscopy, GC–MS and UPLC–MS/MS®, to resolve a complex toxicological fatal case. Forensic Sci. Int.298, 140–148. 10.1016/j.forsciint.2019.03.003
4
AmelineA.GreneyH.MonassierL.RaulJ. S.KintzP. (2019c). Metabolites to parent 3-MeO-PCP ratio in human urine collected in two fatal cases. J. Anal. Toxicol.43, 321–324. 10.1093/jat/bky097
5
BäckbergM.BeckO.HelanderA. (2015a). Phencyclidine analog use in Sweden–intoxication cases involving 3-MeO-PCP and 4-MeO-PCP from the STRIDA project. Clin. Toxicol.53, 856–864. 10.3109/15563650.2015.1079325
6
BäckbergM.LindemanE.BeckO.HelanderA. (2015b). Characteristics of analytically confirmed 3-MMC-related intoxications from the Swedish STRIDA project. Clin. Toxicol.53, 46–53. 10.3109/15563650.2014.981823
7
BakotaE.ArndtC.RomoserA. A.WilsonS. K. (2016). Fatal intoxication involving 3-MeO-PCP: a case report and validated method. J. Anal. Toxicol.40, 504–510. 10.1093/jat/bkw056
8
BerarA.AllainJ. S.AllardS.LefevreC.BaertA.MorelI.et al (2019). Intoxication with 3-MeO-PCP alone: a case report and literature review. Medicine98, e18295. 10.1097/MD.0000000000018295
9
BertolE.PascaliJ.PalumboD.CatalaniV.Di MiliaM. G.FioravantiA.et al (2017). 3-MeO-PCP intoxication in two young men: first in vivo detection in Italy. Forensic Sci. Int.274, 7–12. 10.1016/j.forsciint.2016.12.028
10
ChangB. N.SmithM. P. (2017). A case of unusual drug screening results. Clin. Chem.63, 958–961. 10.1373/clinchem.2016.264507
11
ChengW. C.WongW. C. (2019). Forensic drug analysis of chloro-N,N-dimethylcathinone (CDC) and chloroethcathinone (CEC): identification of 4-CDC and 4-CEC in drug seizures and differentiation from their ring-substituted positional isomers. Forensic Sci. Int.298, 268–277. 10.1016/j.forsciint.2019.03.002
12
de JongL. A. A.OlyslagerE. J. H.DuijstW. L. J. M. (2019). The risk of emerging new psychoactive substances: the first fatal 3-MeO-PCP intoxication in The Netherlands. J. Forensic Leg. Med.65, 101–104. 10.1016/j.jflm.2019.05.011
13
FerreiraB.Dias da SilvaD.CarvalhoF.de Lourdes BastosM.CarmoH. (2019). The novel psychoactive substance 3-methylmethcathinone (3-MMC or metaphedrone): a review. Forensic Sci. Int.295, 54–63. 10.1016/j.forsciint.2018.11.024
14
FrisonG.GregioM.ZamengoL.ZancanaroF.FrassonS.SciarroneR. (2011). Gas chromatography/mass spectrometry determination of mephedrone in drug seizures after derivatization with 2,2,2-trichloroethyl chloroformate. Rapid Commun. Mass Spectrom.25, 387–390. 10.1002/rcm.4842
15
FrisonG.OdoardiS.FrassonS.SciarroneR.OrtarG.RomoloF. S.et al (2015). Characterization of the designer drug bk-2C-B (2-amino-1-(bromo-dimethoxyphenyl)ethan-1-one) by gas chromatography/mass spectrometry without and with derivatization with 2,2,2-trichloroethyl chloroformate, liquid chromatography/high-resolution mass spectrometry, and nuclear magnetic resonance. Rapid Commun. Mass Spectrom.29, 1196–1204. 10.1002/rcm.7211
16
FrisonG.FrassonS.ZancanaroF.TedeschiG.ZamengoL. (2016a). Detection of 3-methylmethcathinone and its metabolites 3-methylephedrine and 3-methylnorephedrine in pubic hair samples by liquid chromatography-high resolution/high accuracy orbitrap mass spectrometry. Forensic Sci. Int.265, 131–137. 10.1016/j.forsciint.2016.01.039
17
FrisonG.ZamengoL.ZancanaroF.TisatoF.TraldiP. (2016b). Characterization of the designer drug deschloroketamine (2-methylamino-2-phenylcyclohexanone) by gas chromatography/mass spectrometry, liquid chromatography/high-resolution mass spectrometry, multistage mass spectrometry, and nuclear magnetic resonance. Rapid Commun. Mass Spectrom.30, 151–160. 10.1002/rcm.7425
18
GomilaI.LeciñenaM. Á.ElorzaM. Á.PastorY.SahuquilloL.ServeraM.et al (2019). Detectability of dissociative psychoactive substances in urine by five commercial phencyclidine immunoassays. J. Anal. Toxicol.43, 497–503. 10.1093/jat/bkz026
19
GrossenbacherF.CazaubonY.FeliuC.AmelineA.KintzP.PassouantO.et al (2019). About 5 cases with 3 Meo-PCP including 2 deaths and 3 non-fatal cases seen in France in 2018. Toxicol. Anal. et Clin.31, 332–336. 10.1016/j.toxac.2019.10.004
20
JameyC.KintzP.MartrilleL.RaulJ. S. (2016). Fatal combination with 3-methylmethcathinone (3-MMC) and gamma-hydroxybutyric acid (GHB). J. Anal. Toxicol.40, 546–552. 10.1093/jat/bkw058
21
JohanssonA.LindstedtD.RomanM.ThelanderG.NielsenE. I.LennbornU.et al (2017). A non-fatal intoxication and seven deaths involving the dissociative drug 3-MeO-PCP. Forensic Sci. Int.275, 76–82. 10.1016/j.forsciint.2017.02.034
22
KalirA. (1981). “Structure activity relationships of phencyclidine derivatives.” in PCP (phencyclidine), historical and current perspectives. Editor DominoE. F (Arbor, MI: NPP Books), 31–46.
23
KintzP.AmelineA.WalchA.FarrugiaA.RaulJ. S. (2019). Murdered while under the influence of 3-MeO-PCP. Int. J. Leg. Med.133, 475–478. 10.1007/s00414-018-1901-x
24
KranenburgR. F.García-CicourelA. R.KukurinC.JanssenH. G.SchoenmakersP. J.van AstenA. C. (2019). Distinguishing drug isomers in the forensic laboratory: GC-VUV in addition to GC-MS for orthogonal selectivity and the use of library match scores as a new source of information. Forensic Sci. Int.302, 109900. 10.1016/j.forsciint.2019.109900
25
KranenburgR. F.PeroniD.AffourtitS.WesterhuisJ. A.SmildeA. K.van AstenA. C. (2020a). Revealing hidden information in GC-MS spectra from isomeric drugs: chemometrics based identification from 15 EV and 70 EV EI mass spectra. Forensic Chem.18, 100225. 10.1016/j.forc.2020.100225
26
KranenburgR. F.van GeenenF. A. M. G.BerdenG.OomensJ.MartensJ.van AstenA. C. (2020b). Mass-spectrometry-based identification of synthetic drug isomers using infrared ion spectroscopy. Anal. Chem.92, 7282–7288. 10.1021/acs.analchem.0c00915
27
LanzarottaA.LorenzL.VoelkerS.FalconerT. M.BatsonJ. (2017). Forensic drug identification, confirmation, and quantification using a fully integrated gas chromatography-fourier transform infrared-mass spectrometer (GC-FT-IR-MS). Appl. Spectrosc.72, 750–756. 10.1177/0003702817746964
28
LarabiI. A.FabresseN.EttingI.NadourL.PfauG.RaphalenJ. H.et al (2019a). Prevalence of New Psychoactive Substances (NPS) and conventional drugs of abuse (DOA) in high risk populations from Paris (France) and its suburbs: a cross sectional study by hair testing (2012-2017). Drug Alcohol Depend.204, 107508. 10.1016/j.drugalcdep.2019.06.011
29
LarabiI. A.FabresseN.EttingI.AbeE.AlvarezJ. C. (2019b). Rapid and simultaneous screening of new psychoactive substances and conventional drugs of abuse. a comparative study of Biochip Array Technology versus LC-MS/MS in whole blood and urine. TIAFT Bull.2, 16–22.
30
LarabiI. A.MartinM.FabresseN.EttingI.EdelY.PfauG.et al (2020). Hair testing for 3-fluorofentanyl, furanylfentanyl, methoxyacetylfentanyl, carfentanil, acetylfentanyl and fentanyl by LC-MS/MS after unintentional overdose. Forensic Toxicol.38, 277–286. 10.1007/s11419-019-00502-0
31
LeeH. Z. S.KohH. B.TanS.GohB. J.LimR.LimJ. L. W.et al (2019). Identification of closely related new psychoactive substances (NPS) using solid deposition gas-chromatography infra-red detection (GC–IRD) spectroscopy. Forensic Sci. Int.299, 21–33. 10.1016/j.forsciint.2019.03.025
32
MaasA.SydowK.MadeaB.HessC. (2017). Separation of ortho, meta and para isomers of methylmethcathinone (MMC) and methylethcathinone (MEC) using LC-ESI-MS/MS: application to forensic serum samples. J. Chromatogr. B Analyt. Technol. Biomed. Life Sci.1051, 118–125. 10.1016/j.jchromb.2017.01.046
33
MaddoxV. H.GodefroiE. F.ParcellR. F. (1965). The synthesis of phencyclidine and other 1-arylcyclohexylamines. J. Med. Chem.8, 230–235. 10.1021/jm00326a019
34
Margasińska-OlejakJ.CelińskiR.FischerA.StojkoJ. (2019). A fatal case of poisoning of a 19-year-old after taking 3-MMC. Forensic Sci. Int.300, e34–e37. 10.1016/j.forsciint.2019.02.040
35
MichelyJ. A.ManierS. K.CasparA. T.BrandtS. D.WallachJ.MaurerH. H. (2017). New psychoactive substances 3-methoxyphencyclidine (3-MeO-PCP) and 3-methoxyrolicyclidine (3-MeO-PCPy): metabolic fate elucidated with rat urine and human liver preparations and their detectability in urine by GC-MS, “LC-(high resolution)-MSn” and “LC-(high resolution)-MS/MS”. Curr. Neuropharmacol.15, 692–712. 10.2174/1570159X14666161018151716
36
Mitchell-MataC.ThomasB.PetersonB.CouperF. (2017). Two fatal intoxications involving 3-methoxyphencyclidine. J. Anal. Toxicol.41, 503–507. 10.1093/jat/bkx048
37
MorrisH.WallachJ. (2014). From PCP to MXE: a comprehensive review of the non-medical use of dissociative drugs. Drug Test. Anal.6, 614–632. 10.1002/dta.1620
38
NowakP. M.OlesekK.WoźniakiewiczM.KościelniakP. (2018). Simultaneous enantioseparation of methcathinone and two isomeric methylmethcathinones using capillary electrophoresis assisted by 2-hydroxyethyl-β-cyclodextrin. Electrophoresis39, 2406–2409. 10.1002/elps.201800142
39
NyczJ. E.PazdziorekT.MaleckiG.SzalaM. (2016). Identification and derivatization of selected cathinones by spectroscopic studies. Forensic Sci. Int.266, 416–426. 10.1016/j.forsciint.2016.06.034
40
OrsoliniL.ChiappiniS.CorkeryJ. M.GuirguisA.PapantiD.SchifanoF. (2019). The use of new psychoactive substances (NPS) in young people and their role in mental health care: a systematic review. Expert Rev. Neurother.19, 1253–1264. 10.1080/14737175.2019.1666712
41
PapaP.ValliA.Di TuccioM.FrisonG.ZancanaroF.BuscagliaE.et al (2019). Analytically confirmed intoxication by 4-fluoromethylphenidate, an analog of methylphenidate. J. Anal. Toxicol.43, e1–e7. 10.1093/jat/bkz001
42
PeacockA.BrunoR.GisevN.DegenhardtL.HallW.SedefovR.et al (2019). New psychoactive substances: challenges for drug surveillance, control, and public health responses. Lancet394, 1668–1684. 10.1016/S0140-6736(19)32231-7
43
PedersenA. J.ReitzelL. A.JohansenS. S.LinnetK. (2013). In vitro metabolism studies on mephedrone and analysis of forensic cases. Drug Test. Anal.5, 430–438. 10.1002/dta.1369
44
PowerJ. D.McDermottS. D.TalbotB.O'BrienJ. E.KavanaghP. (2012). The analysis of amphetamine-like cathinone derivatives using positive electrospray ionization with in-source collision-induced dissociation. Rapid Commun. Mass Spectrom.26, 2601–2611. 10.1002/rcm.6383
45
PowerJ. D.McGlynnP.ClarkeK.McDermottS. D.KavanaghP.O’BrienJ. (2011). The analysis of substituted cathinones. Part 1: chemical analysis of 2-, 3- and 4-methylmethcathinone. Forensic Sci. Int.212, 6–12. 10.1016/j.forsciint.2011.04.020
46
SalernoT. M. G.DonatoP.FrisonG.ZamengoL.MondelloL. (2020). Gas chromatography-Fourier transform infrared spectroscopy for unambiguous determination of illicit drugs: a proof of concept. Front. Chem.8, 624. 10.3389/fchem.2020.00624
47
SchneiderJ. F.DemirgianJ. C.SticklerJ. C. (1986). A comparison of GC/IR interfaces: the light pipe versus matrix isolation. J. Chromatogr. Sci.24, 330–335. 10.1093/chromsci/24.8.330
48
SimmonsS. J.Leyrer-JacksonJ. M.OliverC. F.HicksC.MuschampJ. W.RawlsS. M.et al (2018). DARK classics in chemical neuroscience: cathinone-derived psychostimulants. ACS Chem. Neurosci.9, 2379–2394. 10.1021/acschemneuro.8b00147
49
StevensonR.TuddenhamL. (2014). Novel psychoactive substance intoxication resulting in attempted murder. J Forensic Leg Med25, 60–61. 10.1016/j.jflm.2014.04.007
50
United Nations Office on Drugs and Crime (UNODC) (2020). World drug report 2020. Booklet 4—cross-cutting issues: evolving trends and new challenges. New York, NY: United Nations Publication, Sales No. E.20.XI.6.
51
WallachJ.BrandtS. D. (2018). “Phencyclidine-based new psychoactive substances,” in New psychoactive substances–pharmacology, clinical, forensic and analytical toxicology–handbook of experimental pharmacology. Editors MaurerH. H.BrandtS. D. (Cham, Switzerland: Springer International Publishing AG), Vol. 252, 261–303. 10.1007/164_2018_124
52
WallachJ.De PaoliG.AdejareA.BrandtS. D. (2014). Preparation and analytical characterization of 1-(1-phenylcyclohexyl)piperidine (PCP) and 1-(1-phenylcyclohexyl)pyrrolidine (PCPy) analogues. Drug Test. Anal.6, 633–650. 10.1002/dta.1468
53
ZamengoL.FrisonG.BettinC.SciarroneR. (2014). Understanding the risks associated with the use of new psychoactive substances (NPS): high variability of active ingredients concentration, mislabelled preparations, multiple psychoactive substances in single products. Toxicol. Lett.229, 220–228. 10.1016/j.toxlet.2014.06.012
54
ZamengoL.FrisonG.ZwitserG. (2019). Understanding and managing the new psychoactive substances phenomenon: a holistic approach. J. Publ. Health Pol.40, 217–235. 10.1057/s41271-018-0156-6
55
ZidkovaM.HlozekT.BalikM.KopeckyO.TesinskyP.SvandaJ.et al (2017). Two cases of non-fatal intoxication with a novel street hallucinogen: 3-methoxy-phencyclidine. J. Anal. Toxicol.41, 350–354. 10.1093/jat/bkx009
56
ZubaD.AdamowiczP. (2017). Distinction of constitutional isomers of mephedrone by chromatographic and spectrometric methods. Aust. J. Forensic Sci.49, 637–649. 10.1080/00450618.2016.1167240
Summary
Keywords
3-methoxyphencyclidine, 3-methylmethcathinone, non-fatal intoxication, forensic toxicology, liquid chromatography-high-resolution mass spectrometry, gas chromatography, fourier transform infrared spectroscopy, solid deposition GC-FTIR interface
Citation
Frison G, Zancanaro F, Frasson S, Quadretti L, Agnati M, Vlassich F, Gagliardi G, Salerno TMG, Donato P and Mondello L (2021) Analytical Characterization of 3-MeO-PCP and 3-MMC in Seized Products and Biosamples: The Role of LC-HRAM-Orbitrap-MS and Solid Deposition GC-FTIR. Front. Chem. 8:618339. doi: 10.3389/fchem.2020.618339
Received
16 October 2020
Accepted
22 December 2020
Published
08 February 2021
Volume
8 - 2020
Edited by
Marta Concheiro-Guisan, John Jay College of Criminal Justice, United States
Reviewed by
Larabi Islam Amine, Hôpital Raymond-Poincaré, France
Gabriella Massolini, University of Pavia, Italy
Updates
Copyright
© 2021 Frison, Zancanaro, Frasson, Quadretti, Agnati, Vlassich, Gagliardi, Salerno, Donato and Mondello.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Paola Donato, padonato@unime.it
This article was submitted to Analytical Chemistry, a section of the journal Frontiers in Chemistry
Disclaimer
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.