Abstract
Temperature reflects the balance between production and dissipate of heat. Flexible temperature sensors are primary sensors used for temperature monitoring. To obtain real-time and accurate information of temperature, different flexible temperature sensors are developed according to the principle of flexible resistance temperature detector (FRTC), flexible thermocouple, flexible thermistor and flexible thermochromic, showing great potential in energy conversion and storage. In order to obtain high integration and multifunction, various flexible temperature sensors are studied and optimized, including active-matrix flexible temperature sensor, self-powered flexible temperature sensor, self-healing flexible temperature sensor and self-cleaning flexible temperature sensor. This review focuses on the structure, material, fabrication and performance of flexible temperature sensors. Also, some typical applications of flexible temperature sensors are discussed and summarized.
Introduction
To the best of our knowledge, sensor is the key of various induction equipments, and a critical issue with great potential. In the past decade, a great progress of sensors in many fields is achieved. Sensors with induction feature are playing increasing important roles in various fields, such as medical monitoring, industrial production, wearable equipment, internet of things (IoT), etc (; Kai et al., 2020; Kun et al., 2020; Shao et al., 2020). One important kind of sensors in induction equipment is the flexible temperature sensor. Flexible sensor is a kind of sensor made of flexible material, which has high flexibility, high ductility, even free bending or folding (). It can be arranged arbitrarily, and can detect complex units easily. New types of flexible temperature equipments, textiles, aerospace, environmental medical care, electronics, electricians, sports sensors are widely applied in electronic skin and monitor, etc (Zamri et al., 2015; Jea Sang et al., 2020; Jian et al., 2020; Su et al., 2020; Ye et al., 2020).
A complicated interplay of various regions of flexible temperature sensors is required for flexibility of the most basic feature. In addition, the robots with flexible temperature sensors have increased control over their action. In this review, we summarized the structure, material, fabrication and performance of flexible temperature sensors. We also elaborated the most widely accepted theory concerning the flexible temperature sensors and the evidence supporting this theory. Finally, we reviewed the applications of flexible temperature sensors in various fields, especially in power system, industrial production and medical device.
Traditional Flexible Temperature Sensors
Structure, material, fabrication and performance are important factors of flexible temperature sensors. Development of flexible temperature sensors with digitalization and intelligence is still a great challenge. Previous studies found that the structure, material and fabrication process have great influences on the performance of sensors (J Mittemeijer, 2011; Nosbi et al., 2010; ). It is noted that this trend is consistent with the design of flexible temperature sensors. Various flexible temperature sensors are developed according to the principles, such as flexible resistance temperature detector (FRTC), flexible thermocouple, flexible thermistor, flexible thermochromic (Ying et al., 2011; Zhang et al., 2017). This section will introduce several typical flexible temperature sensors.
Flexible Resistance Temperature Detector
FRTC is the most common flexible temperature sensor. In particular, FRTC converts the applied temperature into electrical signal, which has been widely explored. Monitoring health conditions of the humanās body via detecting the subtle temperature variation related with humanās activities is possible, such as the bodyās temperature. High sensitivity, high flexibility, and excellent reliability are required for FRTC in practical applications (; Zhang et al., 2017). To achieve high-performance FRTC, considerable efforts have been made in optimization of the materials and device configurations. First, various active materials such as graphene, carbon black (CB), carbon fiber, carbon nanotube (CNT) and multi-walled CNT (MWCNT) (Liu et al., 2012; Guo et al., 2014; Tian et al., 2015; Wang et al., 2017; Wu et al., 2019) have been introduced into FRTC as the conductive fillers due to their high conductivity, low cost, and high stability (Kun et al., 2020; ; Jea Sang et al., 2020; Su et al., 2020; Jian et al., 2020; Ye et al., 2020; Zamri et al., 2015; J Mittemeijer, 2011; Nosbi et al., 2010; ; Zhang et al., 2017a; Ying et al., 2011; Wang et al., 2017). Second, for obtaining highly flexible and stretchable devices, polymers including polydimethylsiloxane (PDMS) (Shih et al., 2010; Sibinski et al., 2010; Zhao et al., 2018a), silicon rubber, poly (vinylidene fluoride) (PVDF), polymethyl methacrylate (PMMA) and poly (3,4-ethylenedioxythiophene-poly (styrenesulfonate) (PEDOT: PSS) (Nakata and Arie, 2017; Huang et al., 2018; Shen et al., 2018; Chen et al., 2018; ) have been widely investigated in FRTC (Shih et al., 2010; Sibinski et al., 2010; Liu et al., 2012; Guo et al., 2014; Tian et al., 2015; Nakata and Arie, 2017; Wang et al., 2017; Zhao et al., 2018a; Huang et al., 2018; Shen et al., 2018; Chen et al., 2018; ; Wu et al., 2019). It is demonstrated that preparation of the polymer merits and the sensing layer of conductive materials is a highly promising way for fabrication of high-performance FRTC. Nano/micro porous structures are applied to obtain sensors with increased sensitivity and improved response speed (Nakata and Arie, 2017; Shen et al., 2018).
The temperature coefficient of resistance (TCR) of most metals is between 0.01 and 0.1°Cā1, and similarly, other conductive materials, e.g., the CNTs incorporated with PEDOT: PSS (Nakata and Arie, 2017; Shen et al., 2018), also exhibited a comparable sensitivity. Applying the percolation effect is a possible strategy for obtaining enhanced sensitivity of temperature sensor (Shen et al., 2018), significantly decreasing resistance of the FRTC by several orders through filling a conductive material into an insulating polymer matrix, e.g., PDMS and silicon rubber (Sibinski et al., 2010). Although percolation-type FRTC typically offers an ultrahigh ĪR/R value, as described in Table 1, this resistance change typically occurs at a narrow range of temperature, limiting their applications in wide-range temperature sensing. Different from the narrow operating temperature, the FRTC focuses on a broader sensing range of 20ā100°C. Piezoelectric polymer matrix (such as PVDF) and conductive polymer matrix (such as PEDOT: PSS) can also be applied in temperature sensing.
TABLE 1
| Device | Material | TCR (°Cā1) | Temperature change (°C) | PTC or NTC | References |
|---|---|---|---|---|---|
| 5 Ć 5 | Silicon rubber-carbon fiber | 0.1823 | 25ā70 | PTC | Zhao et al. (2018a) |
| 1 Ć 1 | Silicon rubber-CB, CNTs | 0.00572 | 20ā80 | PTC | Wang et al. (2017) |
| 1 Ć 1 | Silicon rubber-CB | 10ā4 | 0ā50 | PTC | Liu et al. (2012) |
| 3 Ć 3 | Silicon rubber-carbon fiber | 0.0394 | 20ā80 | PTC | Guo et al. (2014) |
| 12 Ć 12 | Silicon rubber-CB, graphene | 0.0327 | 25ā90 | PTC | Tian et al. (2015) |
| 1 Ć 1 | PDMS-the flake graphite, CNT | 0.028 | 35ā85 | PTC | Wu et al. (2019) |
| 1 Ć 1 | PDMS-porous carbon | 0.11 | 23ā50 | PTC | Zhao et al. (2018a) |
| 4 Ć 4 | PDMS-graphite | 0.0055 | 30ā110 | PTC | Shih et al. (2010) |
| 1 Ć 1 | PMMA-MWCNTs | 0.0013 | 30ā42 | NTC | Sibinski et al. (2010) |
| 10 Ć 10 | PVDF-MWCNTs, PEN | 0.081 | 25ā100 | NTC | Chen et al. (2018) |
| 1 Ć 1 | PVDF-graphite, PEO | 0.1 | 25ā42 | PTC & NTC | Huang et al. (2018) |
| 1 Ć 1 | PEDOT: PSS-CNT | 0.0078 | 20ā60 | NTC | |
| 1 Ć 1 | PEDOT: PESS-CNT | 31 | 10ā50 | NTC | Nakata et al. (2017) |
Comparison of flexible resistance temperature detectors.
Insulating Polymer Matrix
For research work about flexible temperature sensors, it is found that the conductive composites are often applied as the sensing materials of FRTC. In the past several years, some conductive composites containing dispersed conducting carbon nanomaterials in an insulating polymer matrix are investigated for resistance temperature detectors. The conducting carbon nanomaterials include carbon fiber, graphene, porous carbon, silver nanoparticle (NP) and CNT, etc., and the polymer matrices include silicon rubber and PDMS. Resistance temperature detectors are fabricated by bonding the interdigital electrodes and conductive composites with conductive silver glue (Liang et al., 2015). The electrical resistivity of these composites is critically dependent on the volume fraction of conducting filler, well explained by percolation theory. With the increase of temperature, the conductive network chains of conductive composites are destroyed. Additionally, the volume expansion of polymer matrix leads to the decrease of the volume fraction of conducting carbon nanomaterials indirectly, resulting in the increase of bulk electrical resistivity of conductive composites. It shows a characteristic of positive temperature-resistance coefficient (PTC). A new conductive composite is proposed and enables production through screen printing. The new conductive composite is based on conductive material-polymer paste, consisting of PMMA employed as the binder. The PMMA was dissolved in organic solvents at elevated temperature, until a homogenous consistence was achieved. Then MWCNTs were added and mixed with a three-roller mill. The agglomerate sizes of below 10 μm are obtained via rolling. High temperature coefficients are utilized to characterize these temperature sensors, reaching 0.0013°Cā1 in 30ā42°C. It shows a characteristic of negative temperature-resistance coefficient (NTC) (Wu et al., 2019).
Huang and co-workers Huang et al. (2012) proposed a FRTC array by sticking the sensing materials of the conductive composites formed by the silicone rubber and carbon fiber into the interdigital electrodes with conductive silver glue. Figure 1 shows a schematic of this flexible temperature sensor with electrode-substrate-sensing material sandwiched structure. The study results showed that the relationship of resistance of the flexible temperature sensor and distance between sensor and temperature source is linear, and the repeatability of the experimental results is good. Moreover, the resistance of the flexible temperature sensor varies linearly with the ambient temperature between 25 and 70°C. The researchers also discussed the effects of conductive composites with different carbon fiber contents on flexible temperature sensor.
FIGURE 1
Tsao group (Shih et al., 2010) presented a new method for fabricating passive-matrix FRTC array. They dispersed a graphite-PDMS composite on interdigitated copper electrodes patterned on flexible polyimide films. The flexible temperature sensor array with electrode-substrate-sensing material sandwiched structure shown in Figure 2 has 64 sensing cells in an area of 16Ā cm2. Their investigation presented that graphite powder provided the composite high temperature sensitivity. In composites with different graphite volume fractions, they observed that the composite with 15% graphite powder is suitable for on/off devices while the one with 20% graphite powder provides sufficient dynamic range for continuously sensing the change of temperature.
FIGURE 2
PVDF Matrix
Recently some conductive composites containing dispersed conducting carbon nanomaterials in a piezoelectric polymer matrix have been studied for resistance temperature detectors. The conducting carbon nanomaterials are carbon fiber, graphene, graphene oxide, porous carbon, silver NP and CNT, etc., and the polymer matrices are PVDF (Huang et al., 2018; ). Resistance temperature detectors are fabricated by coating the conductive composites on interdigital electrodes using spinning and printing. Another approach is based on nano conductive material-polymer paste, consisting of polyethylene modified polystyrene and rubber as a binder material. These components were dissolved in organic solvents at elevated temperature, until a homogenous consistence is obtained. Afterward, nano conductive material as the filler was added and mixed in a three-roller mill. Rolling is performed until agglomerate sizes of below 10 μm are obtained. Several series of flexible temperature sensors are produced and tested. They have a characteristic of NTC. The functionality of polymer composites is improved through CNTs by enhancing their strength and thermal and electrical conductivities. The composites with CNTs can revolutionize structural materialsā design and production in construction elements. Potential applications in electronic circuits fabricated by printing techniques are smart clothing and flexible electronics including functional elements (e.g., printed transistors) or biochemical sensors. In previously conducted experiments related to CNT layers, a high resistance dependence on temperature is indicated, which allowed for experimenting in the textronic thermal sensory field.
Huang group (Huang et al., 2018) presented a FRTC consisting of graphite-filled polyethylene oxide (PEO) and PVDF sensing layer, silicon rubber substrate and PDMS covering layer, exhibiting a high accuracy of 0.1°C and perfect repeatability nearly 2,000 times in the sensing temperature range of 25ā42°C. The FRTC was fabricated by the following procedure: first, fabricating sensing layer by dissolving the PEO in the deionized (DI) water using a magnetic stirrer for 1Ā h, then adding graphite powder to PEO/DI water solution followed by sonication for 1Ā h and magnetic stirring for 1Ā h. After that, PVDF and N,N-Dimethylformamide (DMF) were introduced and mixed for 3Ā h under heat treatment. The PEO/PVDF/graphite solution was dropped on the polyimide (PI) flexible substrate and coated uniformly using spin-coating. After drying the solution, the sensing layer on silicon rubber was removed and the silicon rubber was covered with PDMS. As electrodes, copper wires were bonded to the ends of FRTC using silver paste.
PEDOT: PSS Matrix
Recently some conductive composites containing dispersed conducting carbon nanomaterials in a conductive polymer matrix are studied for FRTCs. The conducting carbon nanomaterials are carbon fiber, graphene, graphene oxide, porous carbon, silver NP and CNTs, etc., and the typical polymer matrix is PEDOT: PSS (Kanao et al., 2015; Shen et al., 2018). Kanao group (Kanao et al., 2015) demonstrated a FRTC based on CNT ink and PEDOT: PSS solution. For the FRTC, the mixed ink consisting of CNT ink and PEDOT: PSS solution was printed on polyester (PET) substrate through the mixed ink over the polyester shadow mask after string and drying at 70°C for 60Ā min in air ambient. The maximum sensitivity of FRTC of ā¼0.78%°Cā1 at a weight percent ratio (3:1) of mixture is achieved. It showed a NTC characteristic.
Thermistor
The resistance changes could be measured by flexible thermistors with high repeatability and accuracy, and can be easily integrated on one platform. Flexible thermistors are belonged to flexible temperature sensors based on metal film, semiconductor film and alloy film. The flexible thermistors on flexible substrates are fabricated by microelectromechanical system (MEMS) technology, flexible technology, printing technology and coating technology. Metal solder blocks are thought to act as the electrodes of the sensors for connecting conductive and transmission signals.
Flexible thermistors with thermal resistance films are fabricated on flexible PI, PET, or PDMS substrate, in which the thermal resistance films include platinum film, copper film, gold film, silver film, reduced graphene oxide (rGO) film, graphene film, graphene oxide film, silver nanowire (Ag NW) film, vanadium dioxide (VO2) film, CNT film, pentacene/silver NPs film, and silver nanocrystal film, etc (Xiao et al., 2005b; Jeong et al., 2010; Yokota et al., 2015a; Kanao et al., 2015; Guo et al., 2015; Kim et al., 2016; Zhao et al., 2018b; Trung et al., 2018; Chu et al., 2018; Zhu et al., 2018; ; ; Li et al., 2019). The PI, PET, PDMS and polyethylene naphthalate (PEN) substrates offer an excellent thermal insulation. The resistance of thermal resistance film changes with the temperature increasing. As Table 2 described, there is a comparison between different flexible thermistors.
TABLE 2
| Material | TCR (°Cā1) | Temperature (°C) | PTC or NTC | References |
|---|---|---|---|---|
| Ag NWs | 0.00294 | 25ā60 | PTC | |
| Ag nanocrystal | 0.5 | 30ā50 | PTC | |
| rGO | 0.0195 | 30ā80 | NTC | Zhao et al. (2018b) |
| rGO fiber | 0.8 | 30ā45 | NTC | Trung et al. (2018) |
| Ag NWs | 0.00286 | 30ā80 | NTC | Li et al. (2019) |
| Pt | 0.0023 | 25ā200 | PTC | Xiao et al. (2015) |
| Au | 1.4 | 25ā92 | PTC | |
| GNPs | 0.0371 | 20ā80 | PTC | Le et al. (2017) |
| MWCNTs | 0.034 | 20ā80 | PTC | Le et al. (2017) |
| Cu | 0.00273 | 20ā90 | PTC | |
| Ag | 0.002 | ā20ā175 | PTC |
Comparison of different flexible thermistors.
(He et al., 2018) presented a copper flexible thermistor and a platinum film flexible temperature sensor based on serpentine structure (Figure 3). The experimental results demonstrated that the sensitivity of the copper film flexible temperature sensor is about 0.0027°Cā1 while the sensitivity of the one with serpentine is about 0.00136°Cā1. The study indicated that the sensitivity of the platinum film flexible temperature sensor is about 0.00273°Cā1 while the sensitivity of the one with serpentine is about 0.00235°Cā1. Ting group (Ting, 2015) investigated two Ag film flexible thermistors based on different structures, as shown in Figure 3. The obtained results indicated that the sensitivity is about 0.002°Cā1, and the largest hysteresis is smaller than 1%. In addition, the response time is several 10Ā seconds (Ting, 2015).
FIGURE 3
Thermocouple
Flexible thermocouples are belonged to flexible temperature sensors based on alloy film. The flexible thermocouples on flexible substrates are fabricated based on MEMS technology, printing technology or coating technology. Metal solder blocks are thought to act as the electrodes of the sensors for connecting conductive and transmission signals functions. Flexible thermocouples with thermocouple alloy films are fabricated on flexible PI or PDMS substrate, where the thermocouple alloy films are nickel-aluminum-silicon-manganese alloy film, nickel-aluminum alloy film, p-Sb2Te3 film, n-Bi3Te3 film, Bi-Te film and Sb-Te film, etc (Pan et al., 2018; Huynh and Haick, 2018; Su and Shen, 2019). The electrodes of thermocouple temperature sensors are usually prepared from metal films. When the alloy films of two different components are combined into a circuit and the temperature of the two junction points is different, a thermoelectric potential will be generated in the circuit (Trung et al., 2018). By measuring temperature-dependent voltage at the junction of two distinct alloy films, the flexible thermocouple can sense the temperature (; Martin et al., 2010; Su and Shen, 2019).
X. Pan and co-workers (Pan et al., 2018) presented a flexible thermocouple to monitor the in-situ temperature of ion battery. In this flexible thermocouple, the PI is served as flexible substrate, the nickel-aluminum-silicon-manganese alloy film and nickel-aluminum alloy film are served as sensing materials, and the copper film is utilized as electrode. The experimental results showed that in different charge-discharge cycles of batteries, the measurement results of this film thermocouple temperature sensor are consistent with those of ARC instrument.
Huynh group (Huynh et al., 2018) reported a flexible temperature thermocouple consisting of p-Sb2Te3 and n-Bi3Te3 for health monitoring. As the most widely used thermoelectric materials, p-Sb2Te3 and n-Bi3Te3 have high thermoelectric efficiency at room temperature. Based on proof-of-concept prototype, flexible thermocouples of p-Sb2Te3 and n-Bi2Te3 arrays are sputtered on polyimide substrate.
Thermochromic
Thermochromic materials have extensive potential applications in temperature sensors and have received increasing attention. Thermochromic materials are important functional and smart materials. When heated or cooled, the thermochromic materials will possess a thermal memory function, then the color of those will emerge pronounced changes. Comparing the color of thermochromic materials with that of standard color, it is easy and quick to know the surface temperature of measured objects (Li et al., 2019; Zhang et al., 2017; ; ).
Heās group () performed experimental investigations on developing a dressing and wearable flexible temperature sensor by dispersing thermochromic materials into the polyvinyl alcohol and water-soluble polyurethane composites. The prepared thermochromic materials are TC-M/NPCMs by chemical integration of trimesoyl chloride (TMC) and nanoencapsulated phase change materials (NPCMs), exhibiting excellent temperature indicator performance. The temperature on different positions of body surface is obtained by attaching the flexible temperature sensor to different positions of body surface and comparing its color with that of standard color (He et al., 2019).
Polymer
Flexible temperature sensors have been investigated with several sensing materials such as polymer, graphene and CNT, etc. Polymers are employed to fabricate mechanically flexible temperature sensors, in which the polymers are acrylate copolymers, polyvinyl alcohol, etc (; Honda et al., 2014; ; Yokota et al., 2015b). In particular, polymers can be easily synthesized by electrochemical polymerization, e.g., the potentiodynamic method. Cost effectiveness and uniform morphology are the distinctive advantages of electrochemical polymerization. The performance of polymers can be regulated through chemical treatment and doping. The polymers with positive temperature coefficient are utilized for fabricating mechanically flexible temperature sensors that have orders-of-magnitude changes in resistivity over only a few degrees. The need for per-pixel amplification circuitry can be eliminated by extraordinarily large changes in resistivity, as the sensorās output signal can be directly multiplexed and fed to external recording instrument, ultimately decreasing the manufacturing cost and complexity of device.
Kim group (Kim et al., 2019) demonstrated a new type of flexible temperature sensor consisting of polyvinyl alcohol (PVA) function layer, aluminum oxide (Al2O3) encapsulating layer, flexible PEN substrate and sliver patterning electrodes. The fabricated flexible temperature sensor is based on conductive and uniform interdigital sliver patterning electrodes deposited on a flexible PEN substrate by printing technology with reverse offset. The PVA function layer is employed as temperature sensing material deposited by electrohydronamic atomization. The Al2O3 film is used as encapsulating layer deposited by spatial atmospheric atomic layer deposition (SAALD). The heating treatment on flexible temperature sensors was performed at 20ā90°C in an inert environment with the help of dehumidifier inside the sealed chamber. Because of the PVA with negative temperature coefficient, its resistance decreases with the increase of temperature. They also discussed the different performances of the flexible temperature sensor encapsulated and non-encapsulated with Al2O3 film.
New Type of Flexible Temperature Sensor
Flexible temperature sensors with multi-function and high integration have received more and more attentions. According to different functions, flexible temperature sensors can be divided into active-matrix flexible temperature sensor, self-powered flexible temperature sensor, self-healing flexible temperature sensor and self-cleaning flexible temperature sensor. Compared with ordinary flexible temperature sensors, functional flexible temperature sensors introduce new materials, new structures and new technologies, which enable the functional flexible temperature sensors not only to detect temperature, but also have other functions, such as self-power supply, self-healing, self-cleaning, etc (Mallory et al., 2013a; Mallory et al., 2013b).
Flexible temperature sensors play a critical role in early diagnosis via continuous monitoring of complicated conditions in health and disease. The stretchable, active-matrix, self-powered, self-healing and self-cleaning sensing systems are thus revolutionizing the sensors. The linkage of these technologies and advanced materials is particularly specified (Rogers et al., 2010; Yamamoto et al., 2017). Some weak and strong points in the development of flexible temperature sensor are clearly summarized and highlighted. Some aspects about further improvement of flexible temperature sensor are also discussed.
Highly Accurate Flexible Temperature Sensors
The goal of accurate measurement of temperature is to reduce the detection error, which can more accurately detect the current temperature state of the object, and these errors can be found and solved in time, such as in healthcare. Therefore, highly accurate flexible temperature sensors are gathering numerous attentions in chronobiology study, medical application, predicting disease, monitoring postoperative recovery, etc (Kim, 1979; ; Michenfelder, 1991; Schwab, 1997; Mack, 2002; Marshall, 2006; ; Mrozek, 2012; Sheng et al., 2013; Wu et al., 2017; Oh et al., 2018). The main method of preparing highly accurate flexible temperature sensors is using sensing materials with high sensitivity to temperature. Commonly used high sensitivity sensing materials are high-crystallinity silicon or functional composites. In addition, the sensitivity of the flexible temperature sensor can be improved by introducing microstructures into the device to achieve high precision measurement. However, the fabrication process of this accurate flexible temperature sensor consisting of special materials or special structures is relatively complicated.
Wu group (Wu et al., 2017) demonstrated a highly accurate flexible temperature sensor with polysilicon thermistors on flexible PI to monitor brainās temperature with high spatial resolution. The highly accurate flexible temperature sensor has a response time of 1.5Ā s and a sensitivity of ā0.0031°Cā1. The thermal hysteresis of this highly accurate temperature sensor in physiological temperature range of 30ā45°C was less than 0.1°C. Using the passivation layer of silicon nitride, this highly accurate flexible temperature sensor exhibited drift of less than 0.3°C in water for 3 d. The performance of this highly accurate flexible temperature sensor showed a low noise level of 0.025 ± 0.03°C, and the expected transient increases in cortical temperature associated with cortical spreading depolarization. Highly accurate flexible temperature sensor developed in this research is desired to monitor brainās temperature with high resolution and sensitivity.
Oh group () reported a highly accurate flexible temperature sensor with a bioinspired octopus-mimicking adhesive. The highly accurate flexible temperature sensor consists of a composite of CNTs, poly (N-isopropylacrylamide) (pNIPAM)-temperature sensitive hydrogel and poly (3,4-ethylenedioxythiophene) polystyrene sulfonate. The highly accurate flexible temperature sensor exhibited an ultrahigh thermal sensitivity of 2.6%°Cā1 at 25ā40°C, therefore a change of 0.5°C in skinās temperature can be detected accurately. Simultaneously, the PDMS adhesive layer of octopus-mimicking rim structure coated with pNIPAM was fabricated via formation of a single mold through applying undercut phenomenon in photolithography. Without any skin irritation for a long time, the fabricated sensor showed reproducible and stable detection of skinās temperature at repeated attachment/detachment cycles onto skin. This study demonstrated the application of highly accurate flexible temperature sensor in wearable devices for health-care and medical monitoring with a great potential.
Stretchable Flexible Temperature Sensor
To ensure that no performance deterioration occurs due to body movements, the stretchable flexible temperature sensors are required, when stretchable flexible temperature sensors are applied to noncoplanar surfaces including robotās body and humanās skin (Lee et al., 2014; Park et al., 2015; Tee, 2015; ; Gao et al., 2016; Soekadar et al., 2016; Wehner et al., 2016; ). The fabrication of a stretchable flexible temperature sensor with a high mechanical stability under strain is found to be a critical challenge since the change of sensitivity in stretchable flexible temperature sensor occured during stretching. For fabrication of stretchable flexible temperature sensor, stretchable electrical interconnections are challenges. Successful serpentine interconnections of a polymer-encapsulated thin metal film are investigated. To relieve strain which is externally applied onto the whole electronic device, the interconnections are effective tools. Lately, it is reported that the liquid metal interconnections embedded in a deformable polymer substrate can be widely utilized as highly conductive and stretchable electrical interconnections by facile fabrication.
Hong group (Hong et al., 2016) reported the fabrication of a stretchable flexible temperature sensor array with liquid metal interconnections embedded in a deformable polymer substrate. In this study, fabricating a stretchable flexible temperature sensor with a stable performance at a strain up to 30% was available since the stretchable flexible temperature sensorās sensitivity shows high stability during stretching. As shown in Figure 4A, the stretchable flexible temperature sensor consists of SWCNT TFT on PET film (layer 1), gate line (layer 2), source line (layer 3), temperature sensor on PET film and Ag NW sticker (layer4). As shown in Figures 4B,C,D,E, the corresponding mapping of the temperature distribution under stretched palm condition is consistent with the one of the temperature distribution under flat palm condition.
FIGURE 4
Active-Matrix Flexible Temperature Sensor
According to storage devices including transistors or diodes, FRTCs can be classified as passive-matrix FRTCs and active-matrix FRTCs. Passive-matrix FRTCs have simple structure, usually electrode-substrate-sensing material sandwiched structure consisting of a sensing layer, an electrode and a substrate. Active-matrix FRTCs have complex structure which includes organic transistor, gate, thermistor, encapsulation, line and substrate. Active-matrix FRTCs are equipped with transistors or diodes for each unit (Kaltenbrunner et al., 2013). When the switch is turned on, the driving voltage of the specification can be transmitted to the unit. When the switch is turned off, the irrelevant signal can be cut off, so the crosstalk phenomenon can be greatly reduced. Among them, passive-matrix FRTCs are the most used devices in the construction of flexible temperature sensors based on conductive and also the most popular devices for practical applications, because of its simple structure, convenience to implement, and relatively low cost. As opposed to passive-matrix FRTCs, the active-matrix FRTCs allow individual and random access to each unit with high addressing speed and simultaneously maintaining a high density of device (; Sekitani, 2008; Zhang et al., 2015a; Ren et al., 2016).
Ren group (Ren et al., 2016) demonstrated an active-matrix FRTC array with organic field-effect transistor structure (Figures 5A,B). By utilizing a PEN substrate pentacene/silver NPs thermistor, and alumina dielectric, the sensor can be conformally attached to various objects and operated at blow 4Ā V, and a leakage current of about tens of pA is maintained. When changing the operating temperature from 20 to 100°C, this flexible temperature sensor array maintains more than 20 times the output-current change. As shown in Figures 5CāE, when the flexible temperature sensor is attached to a volunteerās forehead, distribution of the measured temperature of the forehead could be obtained.
FIGURE 5
Self-Powered Flexible Temperature Sensor
Self-powered materials enable the equipment to extend the service period through harvesting energy from bodyās temperature and movement (; ; Jayaweera et al., 2018; Liu et al., 2018). It is difficult to provide portable and durable power supply for flexible temperature sensors. At present, many advanced technologies, such as supercapacitors, solar cells, wireless antennas and mechanical energy harvesters, are found to be able to generate electricity and to transmit or store energy in elastic systems (Yang et al., 2013; Song et al., 2014; ; ). How to apply these technologies to flexible temperature sensors and realize energy self-supply is a huge challenge. Transparency of electronic skin tactile sensors can be achieved by using high transparency PDMS and other materials, which can ensure the absorption of energy by mechanical equipment driven by solar energy. Therefore, transparency design is also important. Flexible temperature sensors will also face new challenges, such as biocompatibility, biodegradability, neural interface control, high integration, miniaturization etc., which will become the research hotspots in future (Yang et al., 2009; Hochbaum and Yang, 2010; ; Pugliese et al., 2013; Hernandez et al., 2014; Nour et al., 2014; Yingkui et al., 2015; ; Maity et al., 2017; Nour et al., 2017; Yu et al., 2017; ; Karmakar et al., 2019). Flexible temperature sensor manufactured in large quantities is expected to enter all fields of humanās production and life, and truly serve human beings, which is the future direction of development.
Karmakar group (Karmakar et al., 2019) presented a new type of self-powered flexible temperature sensor consisting of self-charging and triboelectric driven flexible power cell. Commercially available materials are employed in the fabrication of this self-charging triboelectric power cell, such as non-conductive glue, bulk MoS2, normal sheet of paper and graphite powder (Figure 6A). The self-charging triboelectric power cell showed excellent output performance with open circuit voltage of ā¼3.82Ā V at a periodic pressure of 1Ā kPa. The open circuit voltage (Voc) of the self-powered flexible temperature sensor is highly sensitive and has a liner response to temperature. As demonstrated in Figure 6B, the value of average open circuit voltage (Voc) increases with the increase of temperature during heating and cooling. It is observed from Figure 6C that the dV/dT of the self-powered flexible temperature sensor is 0.093Ā VĀ Kā1 in temperature range of 293ā323Ā K.
FIGURE 6
Self-Healing Flexible Temperature Sensor
Self-healing performances of the materials used in the wearable devices enable the extended usage periods if scratch or cut generates. It has high practical value in bionic robots, medical care and other fields. Through self-repairing, the service life of self-healing flexible temperature sensor can be prolonged. This function mainly introduces self-healing characteristics into elastic materials. Self-healing must occur at ambient conditions without any trigger or external stimulus. Herein, we discuss both intrinsic and extrinsic self-healing polymers. The intrinsic self-healing is based on molecular interactions (e.g., Ļ-Ļ stacking, metal-ligand coordination and hydrogen bonding), whereas the extrinsic self-healing polymers are dependent on the release of monomers and catalysts packed in vessels or capsules dispersed in an otherwise nonhealing polymer (Hart et al., 2014; ). Although extrinsic self-healing materials are more efficient in recovering larger-scale damage compared with intrinsic materials, they are, however, less suitable for flexible thin devices because they are not easily fabricated, and their integration into fully functional applications-especially in health monitoring applications-is complicated. The intrinsic self-healing polymers are more advantageous due to their ability to reversibly heal themselves multiple times and functionalization of polymer with different self-healing groups (Woola, 2008; Yang and Urban, 2013; ; Kristen Means1 et al., 2019). Although researchers have achieved self-repairing of flexible temperature sensors, their stability and sensitivity need to be improved.
Self-Cleaning Flexible Temperature Sensor
The self-cleaning function of electronic skin tactile sensor is also of great significance. It has broad application prospects in robots, medical equipment and other fields. However, few results of the self-cleaning function of electronic skin tactile sensor have been reported. Abraham group () showed a self-cleaning sensor composed of thermoresponsive double network nanocomposite (DNNC) membrane including poly (N-isopropylacrylamide) (PNIPAAm) and embedded polysiloxane NPs. When thermoresponsive PNIPAAm hydrogels is thermally cycled above and below its volume phase transition temperature (VPTT) of ā¼33ā35°C, this process will lead to the associated deswelling and reswelling respectively and self-cleaning of materialās surface. A. Kristen Means group (Kristen Means et al., 2019) demonstrated a self-cleaning biosensor consisting of 2-acrylamido-2-methylpropane sulfonic acid (AMPS) and N-isopropylacrylamide (NIPAAm) (ratios of AMPS: NIPAAm are 25: 75 and 0: 100) in the 1st and 2nd networks. Cellular attachment is inhibited by this reported membrane utilizing āself-cleaningā or āactively antifoulingā mechanism through cyclic, continuous deswelling/reswelling in response to subcutaneous tissueās normal temperature fluctuation (Kristen Means et al., 2019).
Applications
Recent progresses in materials and fabrication allow the development of flexible temperature sensors with induction performances highly compatible with other functions, and allow the expansion of applications of flexible temperature sensors. Flexible temperature sensors are indispensable devices with stereotypical applications involving robots, medical health, military, intelligent manufacturing, aircraft safety and daily life (Zheng et al., 2019; Zhang et al., 2015b; Peter et al., 2015), as shown in Figure 7. The applications of flexible temperature sensors will lead to a reduction in cost and an increase in accuracy. Associated with bionic skin, surface acoustic wave, spacecraft and battery, a more comprehensive discussion of applications and importance is elaborated.
FIGURE 7
Power System
In the power system, many major accidents are caused by overheating of electrical equipment (Jintae et al., 2014). Real-time monitoring of the temperature of electrical equipment can discover the hidden danger of overheating of electrical equipment, ensure timely maintenance, eliminate the hidden danger of failure as soon as possible, and greatly reduce the operation accidents of power supply system. Therefore, the safety of power supply area is improved.
Battery Temperature Monitoring
Battery is an emergency standby power supply for operation, control and communication of electrical equipments such as power plants and substations (Huda et al., 2013). High-temperature operation will accelerate the aging of batteries, and even have the risk of explosion. At the same time, there will be bulging, plate deformation and other faults. These battery failures will cause system failures such as operation, control, communication, and erroneous instructions, so it is very important to monitor the real-time temperature of the battery. At present, the temperature monitoring method of storage battery is mainly manual detection by infrared temperature detector, which is low in mechanization and high in cost, and can not realize on-line monitoring. Flexible temperature sensor can be attached to a surface of storage battery to realize the measurement of distributed temperature (Shin et al., 2013). This method is easy to conduct, and can realize fault monitoring and early warning, reducing the security risk of power system.
When the battery operates at high temperature for a long time, it is easy to accelerate the aging of the battery, and aggravate the corrosion of the plate and water loss (). The flexible temperature sensor is used to paste on the surface of the battery, having the advantages of easy install, simple implement and easy integration with equipment. It can monitor the temperature of the battery in real time, warn the failure and reduce hidden dangers (Shih et al., 2010).
Applications of Capacitor Temperature Monitoring
Capacitor is an important component of reactive power compensation in power system. It plays an important role in improving power and reducing line loss (). However, due to the influence of various factors such as external working environment, current overload loss and over rated voltage operation, oil leakage will occur in long-term used capacitors (Pontus et al., 2011). Almost all capacitor faults such as belly bulging, fuse breaking and shell flashing, are accompanied by temperature rise (Lee et al., 2011a). Therefore, capacitor temperature monitoring can detect capacitor faults as early as possible and effectively avoid the power loss caused by capacitor faults. Traditional monitoring methods have some shortcomings, such as high cost, difficult installation and poor insulation (). Flexible temperature sensor can cover the surface of capacitor as a thin film topography, and measure the temperature accurately. It is easy to install and operate, and can realize real-time monitoring and early warning of faults effectively (Shin et al., 2013).
Cable Temperature Monitoring
In the power system, the cable is the main electrical equipment of power plants and substations, and its failure often causes large-scale power outages. Cableās heat mostly occurs at the joint, because the current transmitted in the cable is larger, if the contact resistance is slightly increased, and the temperature will be high (Oprea et al., 2009). Therefore, it is necessary to ensure that all busbar joints are in good contact. Therefore, it is very important to monitor the joint temperature in real time to find out the fault of power equipment and to maintain power equipment in time. Flexible temperature sensors can be used as patches attached to the cable for accurate real-time monitoring of temperature, thereby reducing human consumption, improving the mechanization and efficiency of the power system, so as to more effectively prevent, monitor and repair cable faults ().
Industrial Production
In industrial production, accurate measurement and control of temperature parameters are essential for output quality, production efficiency and safe operation. At present, the commonly used heat treatment and thermal processing are begun to use the flexible temperature sensor to replace the traditional temperature sensor, which has never realized the measurement and control of temperature in the production process or important production equipment.
Surface Acoustic Wave
One of the most concerning performances of surface acoustic wave is the fact that it can propagate along the dielectricās surface. Based on transmitting or intercepting signals from the dielectricās surface, signal processing functions such as filter and sensor can be realized. There is a positive correlation between temperature and frequency. We can obtain accurate signals from the dielectricās surface attached flexible temperature sensors (Kun et al., 2014).
Spacecraft
With the development of aerospace technology, the shape and structure of aircraft become more and more complex. When measuring the surfaceās heat flux, the distance between measured points cannot be smaller because of the size of sensor. Since the base material of thin film resistance temperature sensor is solid material such as glass and ceramics, the measuring end surface of sensor does not coincide well with the model surface, resulting in inaccurate measuring structure. If the sensor has a flexible base, it can solve the problem of measurement of heat flux on the surface of complex surface model to a certain extent. It can not only make the installation of the sensor more convenient, but also make the measurement of end surface coincide with the model surface better (Wang et al., 2015).
Medical Device
The application of temperature sensor in medical electronics is also common. For example, a non-contact thermometer can measure the heat emitted from a remote infrared radiation heat source, a thermistor element temperature sensor for a blood analyzer can be employed for monitoring the temperature of chambers, diffuser lamps and oil-cooled motors in order to avoid overheating. With the development of technology, temperature sensor manufacturers can help designers to reduce the size of medical devices in four ways, including providing flexible packaging options, reducing the size of sensor integrated circuits, integrating multiple sensor functions and intelligent devices.
Bionic Skin
Bionic skin based on various sensory functions of human body is an important development direction in the field of bionics at present. Various bionic sensors can replace organismās response to temperature, humidity and pressure through structure and function design. This has prompted the generation of various bionic sensors. One major bionic sensor is flexible temperature sensor. Application of flexible temperature sensors in bionic skin will provide a much-needed objective tool for temperature induction and help in increasing induction accuracy. A recent analysis of these studies highlighted the importance due to use of various flexible temperature sensors. The authors reported that the flexible temperature sensor array can realize tactile perception, and it provides a design scheme for bionic skin (Wu, 2015; Kumar et al., 2019).
Prosthetics
Prosthetics are essential tools for people with disabilities to gain normal abilities. The current prosthesis only has the function of moving, but it does not have the function of sensing. Flexible temperature sensors are small, highly integrated, and can adhere to surfaces of any shape. If a flexible temperature sensor is applied to an existing prosthesis, the disabled can not only move normally, but also sense the temperature of the object. The application of flexible temperature sensors greatly enhances the sensory experience of people with disabilities and reduces the risk of secondary injuries (Mallory et al., 2013b).
Conclusion and Prospects
Flexible temperature sensors can be applied to robots, medical health, military, intelligent manufacturing, aircraft safety and daily life, and have broad application prospects. Flexible temperature sensors have many characteristics, such as high flexibility, high elasticity, high sensitivity, high resolution, and lightweight. Various sensing principles have been applied to the study of flexible temperature sensors, and have benefited from the emergence of new sensitive materials, new sensor structures and microstructures, as well as advanced technologies such as nano-fabrication and printing technology. Flexible temperature sensors have made breakthroughs in flexibility, sensitivity and multi-function. Most flexible temperature sensors utilizing an individual material only focused on the unitary state of mechanical stimuli or applied composites for multifunctional flexible temperature sensors. Increased manufacturing cost and complicated fabrication process will be obtained by this approach. Therefore, most flexible temperature sensors are still in the laboratory stage, and they are individual and isolate device, therefore, they are not really put into use to serve the human society. The existing flexible temperature array sensors still have difficulties in obtaining both high elasticity and high flexibility. Large-area flexible temperature sensors have poor scalability, are not easy to cut and splice, and have high sensitivity of electronic skin contact. The most important research directions of flexible temperature sensors are high sensitivity and multi-function, self-healing and self-cleaning, self-power supply and transparency (White et al., 2001; Rodriguez-Donate et al., 2011; Jie, 2012).
Statements
Author contributions
RL and LH summarized and wrote the related research progress. YL revised the article. All the authors participated in the discussion, writing and revision of this review.
Funding
This work was supported by the National Natural Science Foundation of China (61971049), the Key Scientific Research Project of Beijing Municipal Commission of Education (KZ202010015024), the Research and Development Program of Beijing Institute of Graphic Communication (Ec202006).
Conflict of interest
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Publisherās note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
References
1
AbdelmoughniT.BillelB.Mohamed OuldZ.AbderrezakG. (2020). FPGA Implementation of a Wireless Sensor Node with Built-In Security Coprocessors for Secured Key Exchange and Data Transfer. Measurement153, 107429.
2
AbrahamA. A.FeiR.CoteG. L.GrunlanM. A. (2013). Self-cleaning Membrane to Extend the Lifetime of an Implanted Glucose Biosensor. ACS Appl. Mater. Inter.5 (24), 12832ā12838. 10.1021/am4040653
3
AtsushiD.NorihikoS.Nobu-HisaK. (2019). Validation for Capacitance National Standard Based on Long-Termmonitoring Results of Standard Capacitors. IEEJ Trans. Electr. Electron. Eng.8 (2), 111ā115.
4
BangJ.LeeW. S.ParkB.JohH.WooH. K.JeonS.et al (2019). Highly Sensitive Temperature Sensor: Ligand-Treated Ag Nanocrystal Thin Films on PDMS with Thermal Expansion Strategy. Adv. Funct. Mater.29 (32), 1903047. 10.1002/adfm.201903047
5
BellL. E. (2008). Cooling, Heating, Generating Power, and Recovering Waste Heat with Thermoelectric Systems. Science321 (5895), 1457ā1461. 10.1126/science.1158899
6
BorghettiM.SerpelloniM.SardiniE.PandiniS. (2016). Behavior of Strain Sensors Based on PEDOT: PSS and Silver Nanoparticles Inks Deposited on Polymer Substrate by Ink Jet Printing. Sensor. Actuat. A-phys.243, 71ā80. 10.1016/j.sna.2016.03.021
7
BurattiniS.GreenlandB. W.ChappellD.ColquhounH. M.HayesW. (2010). Healable Polymeric Materials: a Tutorial Review. Chem. Soc. Rev.39, 1973ā1985. 10.1039/b904502n
8
BustoR.DietrichW. D.GlobusM. Y.ValdĆ©sI.ScheinbergP.GinsbergM. D. (1987). Small Differences in Intraischemic Brain Temperature Critically Determine the Extent of Ischemic Neuronal Injury. J. Cereb. Blood Flow Metab.7 (6), 729ā738. 10.1038/jcbfm.1987.127
9
ChenB.YangY.WangZ. L. (2017). Scavenging Wind Energy by Triboelectric Nanogenerators. Adv. Energ. Mater.8, 1702649ā1702661.
10
ChenD.BingZ.NingQ. (2017). Electronic Textiles Based on Silver Nanowire Conductive Network. Prog. Chem.29 (8), 892ā901.
11
ChenS.JiangK.LouZ.ChenD. (2018). Recent Developments in Graphene-Based Tactile Sensor and E-Skin. Adv. Mater. Tech.3 (2), 1700248.
12
ChenZ.WangZ.LiX.LinY.LuoN.LongM.et al (2017). Flexible Piezoelectric-Induced Pressure Sensors for Static Measurements Based on Nanowires/graphene Heterostructures. ACS Nano11, 4507ā4513. 10.1021/acsnano.6b08027
13
ChengL.XuQ.ZhengY.JiaX.QinY. (2018). A Self-Improving Triboelectric Nanogenerator with Improved Charge Density and Increased Charge Accumulation Speed. Nat. Commun.9, 3773ā3780. 10.1038/s41467-018-06045-z
14
ChengZ.XiaoshuangZ.NingT.YeF.HainanZ.XuexinD. (2020). Rapid Response Flexible Humidity Sensor for Respiration Monitoring Using Nano-Confined Strategy. Nanotechnology31 (12), 125302.
15
ChildsC. (2008). Human Brain Temperature: Regulation, Measurement and Relationship with Cerebral Trauma: Part 1. Br. J. Neurosurg.22 (4), 486ā496. 10.1080/02688690802245541
16
ChortosL.LiuJ.BaoZ. (2016). Pursuing Prosthetic Electronic Skin. Nat. Mater.15, 937ā950. 10.1038/nmat4671
17
ChuS.MajumdarA. (2012). Opportunities and Challenges for a Sustainable Energy Future. Nature488, 294ā303. 10.1038/nature11475
18
ChuY. Z.GuoH. J.YinP. H.LiuJ. S. (2018). Ultra-high Sensitivity Flexible Temperature Sensor Based on Nanoscale Cracks. Mech. Electr. Eng. Tech.47 (11), 33ā59.
19
CuiZ.PobleteF.ZhuY. (2019). Tailoring Temperature Coefficient of Resistance of Silver Nanowire Nanocomposite and Application as Stretchable Temperature Sensor. ACS Appl. Mater. Inter.11 (19), 17836ā17842. 10.1021/acsami.9b04045
20
DasT. K.PrustyS. (2012). Review on Conducting Polymers and Their Applications. Polym. Plast. Technol. Eng.51, 1487ā1500. 10.1080/03602559.2012.710697
21
GaoW.EmaminejadS.NyeinH. Y. Y.ChallaS.ChenK.PeckA.et al (2016). Fully Integrated Wearable Sensor Arrays for Multiplexed In Situ Perspiration Analysis. Nature529, 509ā514. 10.1038/nature16521ā
22
GengX.LiW.WangY. (2018). Reversible Thermochromic Microencapsulated Phase Change Materials for thermal Energy Storage Application in thermal Protective Clothing. Appl. Energ.217, 281ā294. 10.1016/j.apenergy.2018.02.150
23
GhoshS. K.AdhikaryP.JanaS.BiswasA.SencadasV.GuptaS. D.et al (2017). Electrospun Gelatin Nanofiber Based Self-Powered Bio-E-Skin for Health Care Monitoring. Nano Energy36, 166ā175. 10.1016/j.nanoen.2017.04.028
24
GongS.ChengW. (2017). Toward Soft Skin-like Wearable and Implantable Energy Devices. Adv. Energ. Mater.7, 1700648ā1700680. 10.1002/aenm.201700648
25
GuiP.DengF.LiangZ.CaiY.ChenJ. (2018). Micro Linear Generator for Harvesting Mechanical Energy from the Human Gait. Energy154, 365ā373. 10.1016/j.energy.2018.04.123
26
GuoX.HuangY.YuanH.QiuS.LiuP.LiuC. (2014). Design on Signal Acquisition and Temperature Compensation System of Flexible Composite Sensor Array. J. Electron. Meas. Instrumentation28 (11), 1254ā1261.
27
GuoX.HuangY.TengK.LiuP.LiuC.TianH. (2015). Modular Design and Implementation of Flexible Artificial Skin with Temperature and Pressure Sensors. Robot37 (4), 493ā498.
28
GuptaS.LohK. J. (2017). Noncontact Electrical Permittivity Mapping and pH-Sensitive Films for osseo Integrated Prosthesis and Infection Monitoring. IEEE Trans. Med. Imag.36, 2193ā2202. 10.1109/tmi.2017.2707390
29
HartL. R.HunteJ. H.NguyenN. A.HarriesJ. L.GreenlandB. W.MackayM. E.et al (2014). Multivalency in Healable Supramolecular Polymers: the Effect of Supramolecular Cross-Link Density on the Mechanical Properties and Healing of Non-covalent Polymer Networks. Polym. Chem.5, 3680ā3688. 10.1039/c4py00292j
30
HeL. F.DouW. K.LiuJ. S. (2018). Fabrication and Performance Test of Polyimide Flexible Temperature Sensors. Mech. Electr. Eng. Tech.47 (11), 5ā8.
31
HeY.LiW.HanN.WangJ.ZhangX. (2019). Facile Flexible Reversible Thermochromic Membranes Based on Micro/nanoencapsulated Phase Change Materials for Wearable Temperature Sensor. Appl. Energ.247, 615ā629. 10.1016/j.apenergy.2019.04.077
32
HernandezS.CaudaV.ChiodoniA.DallortoS.SaccoA.HidalgoD.et al (2014). Optimization of 1d ZnO@TiO2 Core-Shell Nanostructures for Enhanced Photoelectrochemical Water Splitting under Solar Light Illumination. ACS Appl. Mater. Inter.6, 12153ā12167. 10.1021/am501379m
33
HochbaumA. I.YangP. (2010). Semiconductor Nanowires for Energy Conversion. Chem. Rev.110, 527ā546. 10.1021/cr900075v
34
HondaW.HaradaS.ArieT. (2014). Wearable, Human-Interactive, Health-Monitoring, Wireless Device Fabricated by Macroscale Printing Techniques. Adv. Funct. Mater.24 (22), 3298. 10.1002/adfm.201470144
35
HongS. Y.LeeY. H.ParkH. (2016). Stretchable Active Matrix Temperature Sensor Array of Polyaniline Nanofibers for Electronic Skin. Adv. Mater.28, 930ā935. 10.1002/adma.201504659
36
HuangY.ZengX.WangW.GuoX.HaoC.PanW.et al (2018). High-resolution Flexible Temperature Sensor Based Graphite-Filled Polyethylene Oxide and Polyvinylidene Fluoride Composites for Body Temperature Monitoring. Sensors Actuators A: Phys.278, 1ā10. 10.1016/j.sna.2018.05.024
37
HuangY.ZhaoX.YangQ.WuS.LiuC.et al (2012). Flexible tactile sensor system for robot skin based on LabVIEW. 2012 IEEE International Conference on Information and Automation. 563ā567. 10.1109/ICInfA.2012.6246867
38
HudaA. S. N.TaibS. (2013). Suitable Features Selection for Monitoring thermal Condition Of electrical Equipment Using Infrared Thermography. Infrared Phys. Tech.61, 184ā191. 10.1016/j.infrared.2013.04.012
39
HuynhT.-P.HaickH. (2018). Autonomous Flexible Sensors for Health Monitoring. Adv. Mater.30, 1802337. 10.1002/adma.201802337
40
J MittemeijerE. (2011). Fundamentals of Materials Science. Springer-Verlag Berlin Heidelberg.
41
JayaweeraE. N.WijewardhanaK. R.EkanayakaT. K.ShahzadA.SongJ. K. (2018). Triboelectric Nanogenerator Based on Human Hair. ACS Sustain. Chem. Eng.6, 6321ā6327. 10.1021/acssuschemeng.8b00136
42
Jea SangH.Hossein HamidiS.RahimS.JiwonK.InsooK. (2020). Textile-Based Stretchable and Flexible Glove Sensor for Monitoring Upper Extremity Prosthesis Functions. IEEE Sensor J.20 (4), 1754ā1760.
43
JeongJ. W.LeeY. D.KimY. M. (2010). The Response Characteristics of a Gas Sensor Based on Poly-3-Hexylithiophene Thin-Film Transistors. Sens. Actuat. B: Chem.146 (1), 40ā45. 10.1016/j.snb.2010.02.019
44
JianW.HengyiL.JunjingM.ZhiqinP.BingW.JunminW. (2020). Stretchable Energy Storage E-Skin Supercapacitors and Body Movement Sensors. Sensor and Actuators B-Chemical305, 127529. 10.1016/s0925-4005(19)31802-7
45
JiangB. (2017). Study on Application of Intelligent Flexible Temperature Pressure Sensor in Power System. Comp. Meas. Control.25 (11), 307ā315.
46
JieZ. (2012). Development and challenge of Chinese Industrial Robot. Aeronaut. Manufacturing Tech.12, 26ā29.
47
JintaeC.Jae-HanK.Hak-JuL.Ju-YongK.Il-KeunS.Joon-HoC. (2014). Development and Improvement of an Intelligent Cable Monitoring System for Underground Distribution Networks Using Distributed Temperature Sensing. Energies7 (2), 1076ā1094.
48
KaiL.YihuiL.JinchuanS.DongshengZ.QiangZ. (2020). Multi-sensor Fusion for Body Sensor Network in Medical Human-Robot Interaction Scenario. Inf. Fusion57, 15ā26.
49
KaltenbrunnerM.SekitaniT.ReederJ.YokotaT.KuribaraK.TokuharaT.et al (2013). Nature499, 458. 10.1038/nature12314
50
KanaoK.HaradaS.YamamotoY.HondaW.ArieT.AkitaS.et al (2015). Highly Selective Flexible Tactile Strain and Temperature Sensors against Substrate Bending for an Artificial Skin. RSC Adv.5 (38), 30170ā30174. 10.1039/c5ra03110a
51
KarmakarS.KumbhakarP.MaityK.MandalD.KumbhakarP. (2019). Development of Flexible Self-Charging Triboelectric Power Cell on Paper for Temperature and Weight Sensing. Nano Energy63, 103831. 10.1016/j.nanoen.2019.06.027
52
KimH.LeeJ. A.SimH. J.BaughmanM. D. Lima. R. H.KimS. J. (2016). Temperature-Responsive Tensile Actuator Based on Multi-Walled Carbon Nanotube Yarn. Nano-micro Lett.8 (3), 254ā259. 10.1007/s40820-016-0084-6
53
KimJ. H. (1979). Clinical and Biological Studies of Localized Hyperthermia. Cancer Res.39, 2258ā2261.1979
54
KimS. W.RehmanM. M.SajidM. (2019). Encapsulation of Polyvinylalcohol Based Flexible Temperature Sensor through Spatial Atmospheric Atomic Layer Deposition System to Enhance its Lifetime. Thin Solid Films673, 44ā51. 10.1016/j.tsf.2019.01.034
55
Kristen MeansA.DongP.ClubbF. J.Jr.FriedemannM. C.ColvinL. E.ShrodeC. A.et al (2019). A Self-Cleaning, Mechanically Robust Membrane for Minimizing the Foreign Body Reaction: towards Extending the Lifetime of Sub-Q Glucose Biosensors. J. Mater. Sci. Mater. Med.30, 79. 10.1007/s10856-019-6282-2
56
KumarA.SinglaM. L.KumarA.RajputJ. K. (2019). Fabrication and Linearization of Conformable POMANI-Mn3O4 Nanocomposite Based Thermistor for Temperature Monitoring Applications in Prosthetic Gloves. Sens. Actuat. A-phys.285, 588ā598. 10.1016/j.sna.2018.11.036
57
KunQ.HongboW.XiaoluY.XuejiaoT.MengyingL.YumanZ.et al (2020). Core-sheath Nanofiber Yarn for Textile Pressure Sensor with High Pressure Sensitivity and Spatial Tactile Acuity. J. Colloid Interf. Sci.561, 93ā103.
58
KunZ.WangW. D.QiuZ. M. (2014). Research on the Surface Acoustic Wave Temperature Sensor. Appl. Mech. Mater.543-547, 1266ā1269.
59
LeM. Q.GanetF.AudigierD.CapsalJ.-F.CottinetP.-J. (2017). Printing of Microstructure Strain Sensor for Structural Health Monitoring. Appl. Phys. A.123 (5), 354. 10.1007/s00339-017-0970-x
60
LeeS.InoueY.KimD.ReuvenyA.KuribaraK.YokotaT.et al (2014). A Strain-Absorbing Design for TissueāMachine Interfaces Using a Tunable Adhesive Gel. Nat. Commun.5, 5898. 10.1038/ncomms6898
61
LeeC.LeeS.ShenC.YheC.ChangC.LoY. (2011a). Application of Flexible Micro Temperature Sensor in Oxidative SteamReforming by a Methanol Micro Reformer. Sensor11 (2), 2246ā2256.
62
LeeC.LeeS.TangM.ChenP. (2011b). In Situ Monitoring of Temperature inside Lithium-Ion Batteries by Flexible Micro Temperature Sensors. Sensor11 (10), 9942ā9950.
63
LiS.LiuD.TianN.LiangY.GaoC.WangS.et al (2019). High-performance Temperature Sensor Based on Sliver Nanowires. Mater. Today Commun.20, 100546. 10.1016/j.mtcomm.2019.100546
64
LiW.ZhangX.WangY. (2012). Fabrication and Morphological Characterization of Microencapsulated Phase Change Materials (MicroPCMs) and Macrocapsules Containing MicroPCMs for thermal Energy Storage. Energy38, 249ā254. 10.1016/j.energy.2011.12.005
65
LiangY.LiJ.ShihongL.JinW.LvG.LuoH. (2015). Research on Silver a Conductive Adhesive with High-Temperature-Resistant. Precious Met.36 (4), 22ā31.
66
LiuJ.GoswamiA.JiangK.KhanF.KimS.McGeeR.et al (2018). Direct-current Triboelectricity Generation by a Sliding Schottky Nanocontact on MoS2 Multilayers. Nat. Nanotechnol.13, 112ā116. 10.1038/s41565-017-0019-5
67
LiuP.HuangY.LianC. (2012). Equation of Resistance-Temperature of Flexible Tactile Sensor Based on Temperature-Sensitive Conductive Rubber. Polym. Mater. Sci. Eng.28 (6), 107ā109.
68
MackM. G. (2002). MRguided ablation of head and neck tumors. Magn. Reson. Imaging Clin. North. Am.10, 707ā713. 10.1016/s1064-9689(02)00016-8
69
MaityK.MahantyB.SinhaT. K.GarainS.BiswasA.GhoshS. K.et al (2017). Two-dimensional Piezoelectric MoS2-Modulated Nanogenerator and Nanosensor Made of Poly(vinlydinefluoride) Nanofiber Webs for Self-Powered Electronics and Robotics. Energy Technol.5, 234ā243. 10.1002/ente.201600419
70
MalloryL. H.ChortosA.TeeB. C-K.TokJ. B-H.ZhenanB. (2013). 25th Anniversary Article: the Evolution of Electronic Skin (E-Skin): A Brief History, Design Considerations, and Recent Progress. Adv. Mater.25 (42), 5997ā6038.
71
MalloryL.HammockA. C.BenjaminC. (2013). 25th Anniversary Article: the Evolution of Electronic Skin (E-Skin): A Brief History, Design Considerations, and Recent Progress. Adv. Mater.25 (42), 5997ā6038. 10.1002/adma.201302240
72
Man KayL.AmineB.LuongH. C. (2010). A Sub-mu W Embedded CMOS Temperature Sensor for RFID Food MonitoringApplication. IEEE J. Solid-State Circuits45 (6), 1246ā1255.
73
MarshallI. (2006). Measurement of Regional Brain Temperature Using Proton Spectroscopic Imaging: Validation and Application to Acute Ischemic Stroke. Magn. Reson. Imaging24, 438ā446. 10.1016/j.mri.2006.02.002
74
MartinJ.TrittT.UherC. (2010). High Temperature Seebeck Coefficient Metrology. J. Appl. Phys.108, 121101. 10.1063/1.3503505
75
MichenfelderJ. D. (1991). The Relationship Among Canine Brain Temperature, Metabolism, and Function during Hypothermia. Anesthesiology75, 130ā136. 10.1097/00000542-199107000-00021
76
MrozekS. (2012). Brain Temperature: Physiology and Pathophysiology after Brain Injury. Anesthesiol. Res. Pract., 989487. 10.1155/2012/989487
77
MurphyE. B.WudF. (2009). The World of Smart Healable Materials. Prog. Polym. Sci.35 (1-2), 223ā251.
78
NakataS.ArieT. (2017). Wearable, Flexible, and Multifunctional Healthcare Device with an ISFET Chemical Sensor for Simultaneous Sweat pH and Skin Temperature Monitoring. ACS Sensors2, 443ā448. 10.1021/acssensors.7b00047
79
NosbiN.AkilH. M.Mohd IshakZ. A.Abu BakarA. (2010). Degradation of Compressive Properties of Pultruded Kenaf Fiber Reinforced Composites after Immersion in Various Solutions. Mater. Des.31, 4960ā4964. 10.1016/j.matdes.2010.04.037
80
NourE. S.NurO.WillanderM. (2017). Zinc Oxide Piezoelectric Nano-Generators for Low Frequency Applications. Semicond. Sci. Technol.32ā064015. 10.1088/1361-6641/aa6bde
81
NourE. S.SandbergM. O.WillanderM.NurO. (2014). Handwriting Enabled Harvested Piezoelectric Power Using ZnO Nanowires/polymer Composite on Paper Substrate. Nano Energy9, 221ā228. 10.1016/j.nanoen.2014.07.014
82
OhJ. H.HongS. Y.ParkH. (2018). Fabrication of High-Sensitivity Skin-Attachable Temperature Sensors with Bioinspired Microstructure Adhesive. ACS Appl. Mater. Inter.10, 7263ā7270. 10.1021/acsami.7b17727
83
OpreaA.CourbatJ.BarsanN.BriandD.de RooijN.WeimarF. U. (2009). Temperature, Humidity and Gas Sensors Integrated on Plastic Foil for Low Power Applications. Sens. Actuat. B-chem.140 (1), 227ā232. 10.1016/j.snb.2009.04.019
84
PanX.YangY.WangQ.ZhouZ.LiG. (2018). Research on Flexible Thin-Film Sensor Applied for In-Situ Temperature Monitoring of Lithium Ion Battery. Transducer Microsystem Tech.37 (5), 27ā33.
85
ParkS. I.BrennerD. S.ShinG.MorganC. D.CopitsB. A.ChungH. U.et al (2015). Soft Stretchable, Fully Implantable Miniaturized Optoelectronic Systems for Wireless Optogenetics. Nat. Biotechnol.33, 1280ā1286. 10.1038/nbt.3415
86
PeterK.BernhardF.AndreasH. (2015). Voltage-Dependent Capacitance, Aging Effects, and Failure Indicators ofDouble-Layer Capacitors during Lifetime Testing. Chemelectrochem2 (1), 160ā170.
87
PontusS.JohanL.OlleG.MartenB.GoranL. (2011). Novel Field Test Equipment for Lithium-Ion Batteries in HybridElectrical Vehicle Applications. Energies4 (5), 741ā757.
88
PuglieseD.BellaF.CaudaV.LambertiA.SaccoA.TressoE.et al (2013). A Chemometric Approach for the Sensitization Procedure of ZnO Flowerlike Microstructures for Dye-Sensitized Solar Cells. ACS Appl. Mater. Inter.5, 11288ā11295. 10.1021/am403527m
89
RenX. C.PeiK.PengB. Y.ZhangZ. C.WangZ. R.WangX. Y.et al (2016). A Low-Operating-Power and Flexible Active-Matrix Organic-Transistor Temperature-Sensor Array. Adv. Mater.28, 4832ā4838. 10.1002/adma.201600040
90
Rodriguez-DonateC.Osornio-RiosA.Rooney Rivera-GuillenJ.Romero-TroncosoR. D. (2011). Fused Smart Sensor Network for Multi-Axis Forward Kinematics Estimation in Industrial Robots. Sensors11 (4), 4335ā4357. 10.3390/s110404335
91
RogersJ. A.SomeyaT.HuangY. (2010). Materials and Mechanics for Stretchable Electronics. Science327 (26), 1603ā1607. 10.1126/science.1182383
92
SchwabS. (1997). Brain Temperature Monitoring and Modulation in Patients with Severe MCA Infarction. Neurology48, 762ā727. 10.1212/wnl.48.3.762
93
SekitaniT. (2008). A Rubberlike Stretchable Active Matrix Using Elastic Conductors. Science321, 1468ā1472. 10.1126/science.1160309
94
ShaoW.GeZ.SongZ. (2020). Bayesian Just-In-Time Learning and its Application to Industrial Soft Sensing. IEEE Transaction Ind. Inform.16 (4), 2787ā2798.
95
ShenY.HeP.ZhuangX. Y. (2018). Fracture Model for the Electrical Percolation Threshold in CNTs/Polymer Composites. Front. Struct. Civ. Eng.12 (1), 125ā136. 10.1007/s11709-017-0396-8
96
ShengX.ZhangY.ChoJ. (2013). Stretchable Batteries with Self Similar Serpentine Interconnects and Integrated Wireless Recharging Systems. Nat. Commun.4, 1543.
97
ShihW. P.TsaoL. C.LeeC. W.ChengM. Y.ChangC.YangY. J.et al (2010). Flexible Temperature Sensor Array Based on a Graphite-Polydimethylsiloxane Composite. Sensors (Basel)10 (4), 3597ā3610. 10.3390/s100403597
98
ShinH.ChoJS.KimJ.KinJ. (2013). Study of Optimal Location and Compensation Rate of Thyristor-ControlledSeries Capacitor Considering Multi-Objective Function. J. Electr. Eng. Tech.8 (3), 428ā435.
99
SibinskiM.JakubowskaM.SlomaM. (2010). Flexible Temperature Sensors on Fibers. Sensors10 (9), 7934ā7946. 10.3390/s100907934
100
SoekadarS. R.WitkowskiM.GómezC.OpissoE.MedinaJ.CorteseM.et al (2016). Hybrid EEG/EOG-based Brain/neural Hand Exoskeleton Restores Fully Independent Daily Living Activities after Quadriplegia. Sci. Robot.1 (1), 3296. 10.1126/scirobotics.aag3296
101
SongZ.MaT.TangR.ChengQ.WangX.KrishnarajuD.et al (2014). Origami Lithium-Ion Batteries. Nat. Commun.5, 3140ā3145. 10.1038/ncomms4140
102
SuHyeon.ShenHaishan. (2019). Seungwoo Han, āFlexible Thermoelectric Module Using Bi-te and Sb-Te Thin Films for Temperature Sensors. Electron. Mater.48 (9), 5464ā5470.Lee
103
SuL.HuangX.GuoW.WuH. (2020). A Flexible Microwave Sensor Based on Complementary Spiral Resonator for Material Dielectric Characterization. IEEE Sensor J.20 (4), 1893ā1903.
104
TeeB. C.-K. (2015). A Skin-Inspired Organic Digital Mechanoreceptor. Science350, 313ā316. 10.1126/science.aaa9306
105
TianH.LiuP.GuoX.LiuC.HuangY. (2015). Flexible Pressure Temperature Composite Perceptual System Based on Conductive Rubber. Transducer Microsystem Tech.34 (10), 100ā104.
106
TingY. (2015). Fabrication of Silver Interdigitated Electrodes on Polyimide Films via Surface Modification and Ion-Exchange Technique and its Flexible Humidity Sensor Application. Sensor Actuator B: Chem.208, 327ā333.
107
TrungT. Q.LeH. S.DangT. M. L. (2018). Freestanding, Fiber-Based, Wearable Temperature Sensor with Tunable thermal index for Healthcare Monitoring. Adv. Healthc. Mater.7, 1800074. 10.1002/adhm.201800074
108
TsuyoshiS.et al (2009). Organic Nonvolatile Memory Transistors for Flexible Sensor Arrays. Science326, 1516ā1519. 10.1126/science.1179963
109
WangC.XiaK.ZhangM.JianM.ZhangY. (2017). An All-Silk-Derived Dual-Mode E-Skin for Simultaneous Temperature-Pressure Detection. ACS Appl. Mater. Inter.9, 39484ā39492. 10.1021/acsami.7b13356
110
WangG.ChenD.ChenK.ZhangZ. (2015). The Current Research Status and Development Strategy on Biomimetic Robot. J. Mech. Eng.51 (13), 27ā44.
111
WehnerM.TrubyR. L.FitzgeraldD. J.MosadeghB.WhitesidesG. M.LewisJ. A.et al (2016). An Integrated Design and Fabrication Strategy for Entirely Soft, Autonomous Robots. Nature536, 451ā455. 10.1038/nature19100
112
WuW. (2015). Research Progress of Humanoid Robots for mobile Operation and Artificial Intelligence. J. Harbin Inst. Tech.47 (7), 1ā19.
113
WhiteS. R.SottosN. R.GeubelleP. H.MooreJ. S.KesslerM. R.SriramS. R.et al (2001). Autonomic Healing of Polymer Composites. Nature409, 794ā797. 10.1038/35057232
114
WoolaR. P. (2008). Self-healing Materials: a Review. Soft Matter4, 400ā418. 10.1039/b711716g
115
WuA. S. N.TaibS. (2013). Suitable Features Selection for Monitoring thermal Condition Of electrical Equipment Using Infrared Thermography. Infrared Phys. Tech.61, 184ā191. 10.1016/j.infrared.2013.04.012
116
WuL.QianW. J.PengJ. (2019). Screen-printed Flexible Temperature Sensor Based on FG/CNT/PDMS Composite with Constant TCR. Mater. Elect.30 (10), 9593ā9601.
117
WuZ.LiC.HartingsJ. (2017). Polysilion-based Flexible Temperature Sensor for Brain Monitoring with High Spatial Resolution. J. Micromechanics Microengineering27, 025001. 10.1088/1361-6439/aa4e99
118
XiaoS.CheL.LiX.WangY. (2015). Key Technology of Micromachined Temperature Sensor Arrays on Polyimide Flexible Substrate. China Machinery Industry15, 184ā188.
119
YamamotoY.TakadaN.ArieA. (2017). Efficient Skin Temperature Sensor and Stable Gel Less Sticky ECG Sensor for a Wearable Flexible Healthcare Patch. Adv. Healthc. Mater.6, 1700495. 10.1002/adhm.201700495
120
YangX.WolcottA.WangG.SoboA.FitzmorrisR. C.QianF.et al (2009). Nitrogen-doped ZnO Nanowire Arrays for Photoelectrochemical Water Splitting. Nano Lett.9, 2331ā2336. 10.1021/nl900772q
121
YangY.UrbanM. W. (2013). Self-healing Polymeric Materials. Chem. Soc. Rev.42, 7446ā7467. 10.1039/c3cs60109a
122
YangY.ZhangH.ZhuG.LeeS.LinZ. H.WangZ. L. (2013). Flexible Hybrid Energy Cell for Simultaneously Harvesting thermal, Mechanical, and Solar Energies. ACS Nano7, 785ā790. 10.1021/nn305247x
123
YeT.WangQ.TianC.SinghR.ZhangY.LiuZ.et al (2020). Dongqing, āMultifunctional Electronic Skin Based on Perovskite Intermediate Gels. Adv. Electron. Mater.6 (3), 1901291.
124
YingH.WeiL.XiaowenZ.ChaoL.YunjianG. (2011). Design and experiment of Flexible Multi-Function Tactile Sensors for Robot Skin. Robot.33 (3), 347ā353.
125
YingkuiY.StubbeS. H.WolfgangH. (2015). Wind, Hydro or Mixed Renewable Energy Source: Preference for Electricity Products when the Share of Renewable Energy Increases. Energy Policy97, 521ā531.
126
YokotaT.InoueY.TerakawaY.ReederaJ.KaltenbrunnerM.WaredT.et al (2015). Ultraflexible, Large-Area, Physiological Temperature Sensors for Multipoint Measurements. PNAS112 (47), 14533ā14538. 10.1073/pnas.1515650112
127
YokotaT.InoueY.TerakawaY. (2015). Ultraflexible, Large-Area, Physiological Temperature Sensors for Multipoint Measurements. PNAS112 (47), 14533ā14538. 10.1073/pnas.1515650112
128
YuH.HeX.DingW.HuY.YangD.LuS.et al (2017). A Self-Powered Dynamic Displacement Monitoring System Based on Triboelectric Accelerometer. Adv. Energ. Mater.7, 1700565ā1700672. 10.1002/aenm.201700565
129
ZamriM. H.Md AkilH.Mohd IshakZ. A.Abu BakarA. (2015). Effect of Different Fiber Loadings and Sizes on Pultruded Kenaf Fiber Reinforced Unsaturated Polyester Composites. Polym. Compos.36 (7), 1224ā1229. 10.1002/pc.23025
130
ZhangC.ZhaoT. S.XuQ.AnL.ZhaoG. (2015). Effects of Operating Temperature on the Performance of Vanadium Redoxflow Batteries. Appl. Energ.155, 349ā353. 10.1016/j.apenergy.2015.06.002
131
ZhangF.ZangY.HuangD.DiC.ZhuD. (2015). Flexible and Self-Powered Temperature-Pressure Dual-Parameter Sensors Using Microstructure-Frame-Supported Organic Thermoelectric Materials. Nat. Commun.6, 8356. 10.1038/ncomms9356
132
ZhangW.JiX.ZengC.ChenK.YinY.WangC. (2017). A New Approach for the Preparation of Durable and Reversible Color Changing Polyester Fabrics Using Thermochromic Leuco Dye-Loaded Silica Nanocapsules. J. Mater. Chem. C5 (32), 8169ā8178. 10.1039/c7tc02077e
133
ZhangW.JiX.ZhengC. (2017). A New Approach for the Preparation of Durable and Reversible Color Changing Polyester Fabrics Using Thermochromic Leuco Dye-Loaded Silica Nanocapsules. J. Mater. Chem. C5, 8169ā8178. 10.1039/c7tc02077e
134
ZhaoJ.ZhangY.HuangY. (2018). 3D Printing Fiber Electrodes for an All-Fiber Integrated Electronic Device via Hybridization of an Asymmetric Supercapacitor and a Temperature Sensor. Adv. Sci.5, 1801114. 10.1002/advs.201801114
135
ZhaoX.-H.MaS.-N.LongH.YuanH.TangC. Y.ChengP. K.et al (2018). Multifunctional Sensor Based on Porous Carbon Derived from Metal-Organic Frameworks for Real Time Health Monitoring. ACS Appl. Mater. Inter.10, 3986ā3993. 10.1021/acsami.7b16859
136
ZhengC.Felipe RoblesP.YongZ. (2019). Tailoring the Temperature Coefficient of Resistance of Silver NanowireNanocomposites and Their Application as Stretchable Temperature Sensors. ACS Appl. Mater. Inter.11 (19), 17836ā17842.
137
ZhuC.ChortosA.WangY.PfattnerR.LeiT.HinckleyA. C.et al (2018). Stretchable Temperature-Sensing Circuits with Strain Suppression Based on Carbon Nanotube Transistors. Nat. Elect.1 (3), 183ā190. 10.1038/s41928-018-0041-0
Summary
Keywords
sensor, nanomaterials, fabrication, energy storage, temperature
Citation
Liu R, He L, Cao M, Sun Z, Zhu R and Li Y (2021) Flexible Temperature Sensors. Front. Chem. 9:539678. doi: 10.3389/fchem.2021.539678
Received
02 March 2020
Accepted
07 September 2021
Published
22 September 2021
Volume
9 - 2021
Edited by
Hongbo Li, Beijing Institute of Technology, China
Reviewed by
Daqin Chen, Hangzhou Dianzi University, China
Yufei Zhao, Beijing University of Chemical Technology, China
Updates
Copyright
Ā© 2021 Liu, He, Cao, Sun, Zhu and Li.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Ye Li, liye@bigc.edu.cn
ā These authors have contributed equally to this work
This article was submitted to Nanoscience, a section of the journal Frontiers in Chemistry
Disclaimer
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.